Rough machining is the first setup which involves rough turning of the material's outer diameter on one side. This is followed by finish outer diameter turning, gear side boring, and deburring to prepare the item for storage or further processing.

Uploaded by

dashingdude77
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
23 views25 pages

FMEA Ok

Rough machining is the first setup which involves rough turning of the material's outer diameter on one side. This is followed by finish outer diameter turning, gear side boring, and deburring to prepare the item for storage or further processing.

Uploaded by

dashingdude77
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 25

OP- 10

Incoming
OPRough Finish
100
150
200

50
0

- 20material
Incoming
Process Intent
Function

OD
Item
Rough Machining first setup
material storage (Bell Side)
& Inspection

Machining
Rough Machining first setup (Bell Side)

51010
storage
first
Finish OD Turning & Gear DEBURRING
side boring

10a
&
Op
Turning
Finish OD Turning & Gear side boring

2020
Finish OD Turning & Gear side boring

setup
30
Finish OD Turning & Gear side boring

-&2020
Gear
Finish OD Turning & Gear side boring

(Bell
Inspection
Finish
Finish OD Turning & Gear side boring

side
2020
Finish OD Turning & Gear side boring

Side)
Op
OD
boring
DEBURRING

2020a
Finish OD Turning & bellside boring

-Turning
Finish OD Turning & bellside boring

40Cross
Finish OD Turning & bellside boring
30 &hole
bellside
Finish OD Turning & bellside boring
Cross hole boring, spherical & Back face.
30boring,
boring
- 40
OPspherical

DEBURRING
45

2D Barcode Matrix Laser marking


Drilling &&Scanning
Tapping
40a
Drilling
50Revision
&50

Multi Gauging
Revision&
60
70

WASHING OILING &Inspection


PACKING
80
Back
90

FINAl
VisualINSPECTION
STORAGE/ DISPATCH
100%
100
Change
0Tapping
Number:
face. Note
: 16.12.2018

Date :16.12.2018
Siddhesh Phalke
MACHINING ALL PROCESS

SUPPLIER : KRANTI INDUSTRIES LTD.


Prashant Shetty, R.Gunjal,Sudhir Patil,
MACHINED DIFFERENTIAL, 3DU 1081746-00-B3

Doc. No. :FMEA/1081746-00-B Rev. No. : 00 Rev.


PREPARED BY FMEA DATE (ORIG) : 05/12/2018
FAILURE MODE AND EFFECTS ANALYSIS HOUSING

Siddhesh,Thakur,Karna,Aman,Ranjeet PROCESS FMEA

PROCESS RESPONSIBILITY : PRODUCTION HEAD KEY DATE


Doc. No. :FMEA/1081746-00-B
FAILURE MODE AND EFFECTS ANALYSIS Rev. No. : 00
Rev. Date :16.12.2018
ITEM HOUSING MACHINED DIFFERENTIAL, 3DU PROCESS RESPONSIBILITY : PRODUCTION HEAD
PART NO& Rev. No. 1081746-00-B3 KEY DATE : 16.12.2018
CORE TEAM Prashant Shetty, R.Gunjal,Sudhir Patil, Siddhesh,Thakur,Karna,Aman,Ranjeet
PREPARED BY Siddhesh Phalke
Concept: PROCESS FMEA
Process: MACHINING FMEA DATE (ORIG) : 05/12/2018
Operation: ALL PROCESS SUPPLIER : KRANTI INDUSTRIES LTD.
Recommended
Process Intent Process Assessment Current Process Controls Action Results
Actions
S O C Respons-
Item Critical v c Current Process control D R L ibility Actio S O D
C
R
Potential Failure Current Process Controls Recommen & Target R
Function Requirement(s) Charac Mode Potential Effect(s) or Failure r Potential Causes of Failure r Prevention
Detection E P A
ded Actions Completion ns E C E
I
P
t. t n T N S Taken V C T N
S T
y c Date

Incoming material storage & Inspection

Quantity Quantity verification during


verification Material shortage Shortage to inhouse production 3 counting error 3 Tagging System unloading 7 63

Material checmical Next operation - Affected Supplier report T.C.& Material - Properties
Properties properties Subsquent Process - Nil 8 Inadequate control at 2 Third party quarterly ( Mechanical & Chemical ) 4
( Mechanical & Out of Customer end - Field Failure supplier Material T.C/ 64
inspection
Chemical ) Specification User End - Nil third party inspection report

Next operation - Affected Incoming Inspection


As cast Out Of Subsquent Pocess - Nil 3 Inadequate control at 2 Inward inspection report/ Supplier PDIR 6
dimensions Specification Customer End - Dissatisfaction supplier foundry PDIR 36
User End - Nil

Next operation - Machining


operation Affected
Inadequate control at Supplier audit & process Incoming Inspection
Excess Hardness Subsquent Process - Nil 8
supplier
2
control at supplier as per IIR
5 80
Incoming Customer End - Field failure
material User End - Nil
5 storage & Hardness
Inspection
Next operation - Nil
Subsquent Process - Nil 8 Inadequate control at 2 Supplier audit & process Incoming Inspection 4
Less Hardness Customer End - Field Failure supplier control at supplier as per IIR 64
User End - Nil

Next operation - Fall out at initial


station Process control at
Die code Mark Subsquent Process - Nil 4 Inadequate control at 3 supplier & visual 7
Tracebability Missing Customer End - Identification supplier 100% visual inspection, 84
inspection
problem
User End - Nil

Poor casting
surface, Improper Next operation - Machining
fettling, Core operation Affected Inadequate control at Process control at Incoming Inspection
Apperance Mismatch, lack of Subsquent Process - Nil 4 supplier 2 supplier & visual as per IIR 6 48
material, crack, Customer End -Dissatisfaction inspection
blow holes User End - Nil
Doc. No. :FMEA/1081746-00-B
FAILURE MODE AND EFFECTS ANALYSIS Rev. No. : 00
Rev. Date :16.12.2018
ITEM HOUSING MACHINED DIFFERENTIAL, 3DU PROCESS RESPONSIBILITY : PRODUCTION HEAD
PART NO& Rev. No. 1081746-00-B3 KEY DATE : 16.12.2018
CORE TEAM Prashant Shetty, R.Gunjal,Sudhir Patil, Siddhesh,Thakur,Karna,Aman,Ranjeet
PREPARED BY Siddhesh Phalke
Concept: PROCESS FMEA
Process: MACHINING FMEA DATE (ORIG) : 05/12/2018
Operation: ALL PROCESS SUPPLIER : KRANTI INDUSTRIES LTD.
Recommended
Process Intent Process Assessment Current Process Controls Action Results
Actions
S O C Respons-
Item Critical v c Current Process control D R L ibility Actio S O D
C
R
Potential Failure Current Process Controls Recommen & Target R
Function Requirement(s) Charac Mode Potential Effect(s) or Failure r Potential Causes of Failure r Prevention
Detection E P A
ded Actions Completion ns E C E
I
P
t. t n T N S Taken V C T N
S T
y c Date

OP- 10 Rough Machining first setup (Bell Side)

Standard Operating 4
Improper setting 2 Procedure 40
Next operation - Will affect
Subsquent Process - Nil
Thickness oversize Customer End - Fitment problem 5 Set Up Approval , FPIR
User End - Nil Insert worn out 4 Tool Change Frequency 4 80

ROUGH FLANGE
THICKNESS 12.00 Standard Operating
± 0.2 Improper setting 2 Procedure 4 40

Next operation - Will affect


Thickness under Subsquent Process - Nil Standard Operating
size Customer End -Fitment problem 5 Part loading error 4 Procedure Set Up Approval , FPIR 4 80
User End - Nil

Insert worn out 5 Tool Change Frequency 3 75


Rough
Machining
10 first setup
Next operation - Component Standard Operating
(Bell Side) Improper setting 2 Procedure 5 50
clamping issue
Subsquent process - Nil 5 Set Up Approval , FPIR
Customer End - Fitment problem
Outer dia User End - Nil Insert worn out 2 Tool Change Frequency 5 40
Outer Dia.156.0 ±
0.3 oversize / under
size Next operation - Component Standard Operating
clamping issue Improper setting 2 Procedure 5 50
Subsquent Process - Nil
Customer End -Fitment Problem 5 Set Up Approval , FPIR
Insert worn out 2 Tool Change Frequency 5 50
User End
Next - Nil - Machining
operation
operation Affected Tool wear out Standard Operating
Improper setting 2 Procedure 5 50
Over size Subsquent Process - Nil 5 Set Up Approval , FPIR
Rough Dia.46.04 Customer End - Fitment problem Insert worn out 2 Tool Change Frequency 5 40
±0.1
(For Dia. Next operation
User End - Nil - Machining
45.015) operation Affected less margine Standard Operating
Subsquent Process - Nil Improper setting 2 Procedure 5 50
Undersize Customer End -Fitment 5 Set Up Approval , FPIR
problem User Insert worn out 2 Tool Change Frequency 5 50
End - Nil
Doc. No. :FMEA/1081746-00-B
FAILURE MODE AND EFFECTS ANALYSIS Rev. No. : 00
Rev. Date :16.12.2018
ITEM HOUSING MACHINED DIFFERENTIAL, 3DU PROCESS RESPONSIBILITY : PRODUCTION HEAD
PART NO& Rev. No. 1081746-00-B3 KEY DATE : 16.12.2018
CORE TEAM Prashant Shetty, R.Gunjal,Sudhir Patil, Siddhesh,Thakur,Karna,Aman,Ranjeet
PREPARED BY Siddhesh Phalke
Concept: PROCESS FMEA
Process: MACHINING FMEA DATE (ORIG) : 05/12/2018
Operation: ALL PROCESS SUPPLIER : KRANTI INDUSTRIES LTD.
Recommended
Process Intent Process Assessment Current Process Controls Action Results
Actions
S O C Respons-
Item Critical v c Current Process control D R L ibility Actio S O D
C
R
Potential Failure Current Process Controls Recommen & Target R
Function Requirement(s) Charac Mode Potential Effect(s) or Failure r Potential Causes of Failure r Prevention
Detection E P A
ded Actions Completion ns E C E
I
P
t. t n T N S Taken V C T N
S T
y c Date

Process control at
Next operation - Machining supplier & visual Incoming Inspection
Excess Material 2 as per IIR 5 40
operation Affected Tool wear out inspection
Subsquent Process -
Radius oversize Nil Customer End - Fitment 4
Insert worn out 2 Tool Change Frequency 5 40
problem User Set Up Approval , FPIR
RADIUS OF DIA End - Nil Standard Operating
118,RADIUS Improper setting 2 Procedure 5 40
2.5,RADIUS Process control at
10,RADIUS 80.00 Next operation - Machining Incoming Inspection
Excess Material 2 supplier & visual as per IIR 5 40
operation Affected less allowance inspection
Subsquent Process - Nil
Radius undersize Customer End -Fitment 4 Insert worn out 2 Tool Change Frequency 5 50
problem User Set Up Approval , FPIR
End - Nil Standard Operating
Improper setting 2 Procedure 5 50

Next operation - Machining Process control at Incoming Inspection


operation Affected Tool wear out Excess Material 2 supplier & visual as per IIR 5 40
inspection
Distance oversize Subsquent Process - Nil 4 Insert worn out 2 Tool Change Frequency 5 40
Customer End - Fitment problem
Set Up Approval , FPIR
Standard Operating
Rough Rough User End - Nil Improper setting 2 Procedure 5 40
Machining Dist .65.40±0.3,7
10 first setup Process control at
5.6.+/-0.2, Next operation - Machining Incoming Inspection
(Bell Side) Excess Material 2 supplier & visual as per IIR 5 50
operation Affected less stock inspection
Subsquent Process - Nil
Distance undersize Customer End -Fitment problem 5 Insert worn out 2 Tool Change Frequency 5 50
Set Up Approval , FPIR
User End - Nil Standard Operating
Improper setting 2 Procedure 5 50

Process control at Incoming Inspection


Next operation - Less clamping area Excess Material 2 supplier & visual as per IIR 5 40
Subsquent inspection
Chamfer oversize Process - Nil Customer End 4
- Dissatisfaction Insert worn out 2 Tool Change Frequency 5 40
User End - Nil Set Up Approval , FPIR
CHAMFER OF Standard Operating
FLANGE 1.0 ±0.3 Improper setting 2 Procedure 5 40
X45°±5°
Next operation - Clamping problem
in next process
Chamfer undersize Subsquent Process - Nil 5 Improper setting 2 Program Control Set Up Approval , FPIR 5 50
Customer End -Dissatisfaction
User End - Nil
Doc. No. :FMEA/1081746-00-B
FAILURE MODE AND EFFECTS ANALYSIS Rev. No. : 00
Rev. Date :16.12.2018
ITEM HOUSING MACHINED DIFFERENTIAL, 3DU PROCESS RESPONSIBILITY : PRODUCTION HEAD
PART NO& Rev. No. 1081746-00-B3 KEY DATE : 16.12.2018
CORE TEAM Prashant Shetty, R.Gunjal,Sudhir Patil, Siddhesh,Thakur,Karna,Aman,Ranjeet
PREPARED BY Siddhesh Phalke
Concept: PROCESS FMEA
Process: MACHINING FMEA DATE (ORIG) : 05/12/2018
Operation: ALL PROCESS SUPPLIER : KRANTI INDUSTRIES LTD.
Recommended
Process Intent Process Assessment Current Process Controls Action Results
Actions
S O C Respons-
Item Critical v c Current Process control D R L ibility Actio S O D
C
R
Potential Failure Current Process Controls Recommen & Target R
Function Requirement(s) Charac Mode Potential Effect(s) or Failure r Potential Causes of Failure r Prevention
Detection E P A
ded Actions Completion ns E C E
I
P
t. t n T N S Taken V C T N
S T
y c Date

Process control at Incoming Inspection


Excess Material 2 supplier & visual as per IIR 5 40
Next operation - Nil inspection
Surface angle Subsquent Process - Nil
oversize Customer End - Dissatisfaction 4
Insert worn out 2 Tool Change Frequency SETUP , FPIR 5 40
User End - Nil
ANGLE 2°, Standard Operating
ANGLE 19° Improper setting 2 Procedure 5 40

Next operation - Nil


Surface angle Subsquent Process - Nil Standard Operating
undersize Customer End -Dissatisfaction Improper setting 2 Procedure SETUP , FPIR 5 50
User End - Nil

Process control at Incoming Inspection


Excess Material 2 supplier & visual as per IIR 5 40
Next operation - Machining inspection
operation Affected
Casting Ref Subsquent Process - Nil
Oversize 4 Insert worn out 2 Tool Change Frequency SETUP , FPIR 5 40
Customer End - Fitment problem
User End - Nil
Standard Operating
Improper setting 2 Procedure SETUP , FPIR 5 40
CAST REF
Process control at
Next operation - Machining supplier & visual Incoming Inspection
Less material allowance 2 as per IIR 5 50
operation Affected less margine inspection
Casting Ref Subsquent Process - Nil
undersize Customer End -Fitment 5
Insert worn out 2 Tool Change Frequency 5 50
problem User SETUP , FPIR
End - Nil Standard Operating
Improper setting 2 Procedure 5 50

Next operation - Nil Standard Operating


Improper setting 2 Procedure 5 40
Subsquent Process - Nil Set Up Approval , FPIR, 100%
Diameter oversize Customer End - Dissatisfaction inspection
User End - Nil Insert worn out 2 Tool Change Frequency 5 40
Dia 64+/-0.3 Next operation - Machining
operation Affected less margine Insert worn out 2 Set up Approval 5 50
Diameter Subsquent Process - Nil Set Up Approval , FPIR, 100%
undersize Customer End -Fitment 5 inspection
problem User Standard Operating
Improper setting 2 Procedure 5 50
End - Nil
5 Less awareness 3 As per WI/PD/27 Visual inspection 4 60
Next Operation - Nil
PART FREE FROM Loose chips, sharp Subsquent Process - Nil
10a DEBURRING BURR, SHARP edge present on Customer End - Dissatisfaction Tool life
EDGES, CHIPS component NPD
End User - Nil 8 Deburring tool wear out 5 Tool Change Frequency Visual inspection 4 160 frequency 15.2.19
to be set
Doc. No. :FMEA/1081746-00-B
FAILURE MODE AND EFFECTS ANALYSIS Rev. No. : 00
Rev. Date :16.12.2018
ITEM HOUSING MACHINED DIFFERENTIAL, 3DU PROCESS RESPONSIBILITY : PRODUCTION HEAD
PART NO& Rev. No. 1081746-00-B3 KEY DATE : 16.12.2018
CORE TEAM Prashant Shetty, R.Gunjal,Sudhir Patil, Siddhesh,Thakur,Karna,Aman,Ranjeet
PREPARED BY Siddhesh Phalke
Concept: PROCESS FMEA
Process: MACHINING FMEA DATE (ORIG) : 05/12/2018
Operation: ALL PROCESS SUPPLIER : KRANTI INDUSTRIES LTD.
Recommended
Process Intent Process Assessment Current Process Controls Action Results
Actions
S O C Respons-
Item Critical v c Current Process control D R L ibility Actio S O D
C
R
Potential Failure Current Process Controls Recommen & Target R
Function Requirement(s) Charac Mode Potential Effect(s) or Failure r Potential Causes of Failure r Prevention
Detection E P A
ded Actions Completion ns E C E
I
P
t. t n T N S Taken V C T N
S T
y c Date

OP - 20 Finish OD Turning & Gear side boring

Next operation - Will be affected Insert worn out 3 Tool Change Frequency 5 40
Subsquent Process - Will
Flange thickness be affected
oversize 5 SETUP , FPIR
Customer End - Fitment problem
User End - Nil Standard Operating 5 40
FLANGE Improper setting 3 Procedure
THICKNESS
10.0±0.3
Less stock from previous Previous operation stock
Next operation - Will be affected operation 2 maintaining 5 50
Subsquent Process - will
Flange thickness be affected
undersize 5 Insert worn out 2 Set up Approval SETUP , FPIR 5 50
Customer End -Fitment problem
User End - Nil Standard Operating
Improper setting 2 Procedure 5 50

Change in Programing 2 Edit Key Lock 4 40


Machining Next operation - Will be affected
Dimensions Flage Parallalism Subsquent Process - Will Improper setting, Jaw
should OK - be affected 5 Boring 2 Setup approval SETUP , FPIR, IPIR 4 60
out of Spec.
Flange Variation Customer End - Dissatisfication
0.05 mm User End - Nil Standard Operating
Clamping Pressure 2 Procedure 4 60

Excess stock from Previous operation stock


previous operation 4 maintaining 3 96
Next operation - Nil
Subsquent Process - Nil
Bearing diameter Customer End - Dissatisfaction SETUP , FPIR, IPIR, 100%
oversize 8 checked on machine
User End - Fitment
problem Insert worn out 4 Tool Change Frequency 3 96
Finish OD BEARING DIA Standard Operating
Turning & Ø55.015+/-0.010 Improper setting 4 Procedure 3 96
20
Gear side
boring Less stock from previous Previous operation stock
operation 2 maintaining 5 80
Next operation -Nil
Subsquent Process - Nil
Bearing diameter Customer End -Dissatisfaction SETUP , FPIR, IPIR, 100%
undersize 8 Insert worn out 2 Set up Approval checked on machine 5 50
User End - Fitment
problem Standard Operating
Improper setting 3 Procedure 5 50

Standard Operating
Loading Problem 3 Procedure 4 60
Next operation - Nil
AXIAL RUNOUT Runout Out Of Subsquent Process - Nil Standard Operating
OF BEARING DIA 5 Improper setting 3 Procedure SETUP , FPIR 4 60
spec. Customer End - Fitment problem
55 User End - Nil
Standard Operating
Clamping Pressure 3 Procedure 4 60
Doc. No. :FMEA/1081746-00-B
FAILURE MODE AND EFFECTS ANALYSIS Rev. No. : 00
Rev. Date :16.12.2018
Finish OD
ITEM HOUSING MACHINED DIFFERENTIAL, 3DU PROCESS RESPONSIBILITY : PRODUCTION HEAD
Turning &
20 NO& Rev. No.
PART Gear side 1081746-00-B3 KEY DATE : 16.12.2018
COREboring
TEAM Prashant Shetty, R.Gunjal,Sudhir Patil, Siddhesh,Thakur,Karna,Aman,Ranjeet
PREPARED BY Siddhesh Phalke
Concept: PROCESS FMEA
Process: MACHINING FMEA DATE (ORIG) : 05/12/2018
Operation: ALL PROCESS SUPPLIER : KRANTI INDUSTRIES LTD.
Recommended
Process Intent Process Assessment Current Process Controls Action Results
Actions
S O C Respons-
Item Critical v c Current Process control D R L ibility Actio S O D
C
R
Potential Failure Current Process Controls Recommen & Target R
Function Requirement(s) Charac Mode Potential Effect(s) or Failure r Potential Causes of Failure r Prevention
Detection E P A
ded Actions Completion ns E C E
I
P
t. t n T N S Taken V C T N
S T
y c Date

Less stock from previous Previous operation stock


operation 2 maintaining 5 60
Next operation - Nil
ID diameter Subsquent Process - Nil
oversize Customer End - Nil 6 Insert worn out 2 Set up Approval SETUP , FPIR 5 60
User End - Nil
Standard Operating
Improper setting 3 Procedure 5 90
INSIDE DIAMETER
47
Excess stock from Previous operation stock
previous operation 2 maintaining 5 60
Next operation - Nil
Subsquent Process - Nil
ID diameter under Customer End - Loose Fitment Standard Operating
size 6 Improper setting 2 SETUP , FPIR, IPIR 5 60
problem Procedure
User End - Nil
Insert worn out 2 Set up Approval 5 60

Excess stock from Previous operation stock


previous operation 2 maintaining 5 40
Next operation - Nil
Subsquent Process -Will affect
Depth oversize Customer End - Fitment problem 4 Insert worn out 2 Set up Approval SETUP , FPIR 5 40
User End - Nil
Standard Operating
DEPTH Improper setting 3 Procedure 5 40
7.5+/-0.1
Next operation - Machining Incoming Inspection
More Access Material 2 Report 5 40
operation Affected less
margine/unclean of surface
Depth undersize Subsquent Process - Nil 4 Insert worn out 2 Set up Approval SETUP , FPIR 5 40
Customer End -Nil
User End - Nil Wrong Offset 2 Edit Key Lock 5 40

Improper setting 2 Setting Approval 5 50


Finish OD Next operation - Nil
Turning & CHAMFER OF DIA Subsquent Process - Nil
20 55, 2±0.3 Out of Spec Customer End - Dissatisfaction 5 Insert worn out 2 Tool Change Frequency SETUP , FPIR 5 50
Gear side
boring User End - Nil
Change in Programing 3 Edit Key Lock 5 50

Next operation - Nil Improper setting 2 Setting Approval 5 50


CHAMFER ANGLE Subsquent Process - Nil
OF DIA 55, Out of Spec Customer End - Dissatisfaction 5 Insert worn out 2 Tool Change Frequency SETUP , FPIR 5 50
30°±30' User End - Fitment
issue
Change in Programing 2 Edit Key Lock 5 50

Change in Programing 2 Edit Key Lock 5 40


Next operation - Nil
SURFACE FINISH Subsquent Process - Nil Insert worn out 2 Tool Change Frequency SETUP , FPIR, Coolant 5 50
OF DIA 55 Ra 1.6 Out of Spec Customer End - Dissatisfaction 4 concentration checksheet
User End - Nil
One per day
Coolant Concentration 2 concentration checking 5 50
Doc. No. :FMEA/1081746-00-B
FAILURE MODE AND EFFECTS ANALYSIS Rev. No. : 00
Rev. Date :16.12.2018
ITEM HOUSING MACHINED DIFFERENTIAL, 3DU PROCESS RESPONSIBILITY : PRODUCTION HEAD
PART NO& Rev. No. 1081746-00-B3 KEY DATE : 16.12.2018
CORE TEAM Prashant Shetty, R.Gunjal,Sudhir Patil, Siddhesh,Thakur,Karna,Aman,Ranjeet
PREPARED BY Siddhesh Phalke
Concept: PROCESS FMEA
Process: MACHINING FMEA DATE (ORIG) : 05/12/2018
Operation: ALL PROCESS SUPPLIER : KRANTI INDUSTRIES LTD.
Recommended
Process Intent Process Assessment Current Process Controls Action Results
Actions
S O C Respons-
Item Critical v c Current Process control D R L ibility Actio S O D
C
R
Potential Failure Current Process Controls Recommen & Target R
Function Requirement(s) Charac Mode Potential Effect(s) or Failure r Potential Causes of Failure r Prevention
Detection E P A
ded Actions Completion ns E C E
I
P
t. t n T N S Taken V C T N
S T
y c Date

Change in Programing 2 Edit Key Lock 5 40


Next operation - Nil
Subsquent Process - Nil
Radius oversize Customer End -Nil 4 Insert worn out 2 Tool Change Frequency SETUP , FPIR 5 40
User End - Fitment problem
Improper setting 2 Setting Approval 5 40
GROOVE OF DIA
55 RADIUS
Change in Programing 2 Edit Key Lock 5 40
Next operation - Nil
Subsquent Process - Nil
Radius undersize Customer End -Nil 4 Insert worn out 2 Tool Change Frequency SETUP , FPIR 5 40
Finish OD User End - Fitment problem
Turning & Improper setting 2 Setting Approval 5 40
20 Gear side
boring Less stock from previous Previous operation stock
operation 3 maintaining 3 72
Next operation - Nil
Subsquent Process - Nil
Diameter oversize Customer End - Fitment problem 8 Insert worn out 3 Tool Change Frequency FPIR, Inprocess Inspection, 3 72
User End - Nil
Dia. Should OK Change in Programing 3 Edit Key Lock 3 72
Ø35.04+/-0.01
Gear SIDE Next operation - Part loading Issue Improper setting 3 Setting Approval 3 72
Diameter Subsquent Process - Nil
undersize Customer End - Loose 8 FPIR, Inprocess Inspection
Fitment problem
User End - Nil Insert worn out 3 Tool Change Frequency 3 72

Next operation - Nil Change in Programm 3 Edit Key Lock 3 72


TOTAL RUN OUT Subsquent Process - Nil
0.08 WRT A-B OF Runout Out Of Customer End - Noise in Fittment Improper setting 3 Setting Approval 3 72
spec. 8 SETUP , FPIR
DIA35 Gear SIDE User End -
Nil Process Parameter Work
Clamping Pressure 3 Instruction 3 72
Doc. No. :FMEA/1081746-00-B
FAILURE MODE AND EFFECTS ANALYSIS Rev. No. : 00
Rev. Date :16.12.2018
ITEM HOUSING MACHINED DIFFERENTIAL, 3DU PROCESS RESPONSIBILITY : PRODUCTION HEAD
PART NO& Rev. No. 1081746-00-B3 KEY DATE : 16.12.2018
CORE TEAM Prashant Shetty, R.Gunjal,Sudhir Patil, Siddhesh,Thakur,Karna,Aman,Ranjeet
PREPARED BY Siddhesh Phalke
Concept: PROCESS FMEA
Process: MACHINING FMEA DATE (ORIG) : 05/12/2018
Operation: ALL PROCESS SUPPLIER : KRANTI INDUSTRIES LTD.
Recommended
Process Intent Process Assessment Current Process Controls Action Results
Actions
S O C Respons-
Item Critical v c Current Process control D R L ibility Actio S O D
C
R
Potential Failure Current Process Controls Recommen & Target R
Function Requirement(s) Charac Mode Potential Effect(s) or Failure r Potential Causes of Failure r Prevention
Detection E P A
ded Actions Completion ns E C E
I
P
t. t n T N S Taken V C T N
S T
y c Date

Incoming Inspection
Next operation - Nil More Access Material 2 Report 5 50
Groove dist Subsquent Process - Nil
oversize Customer End - Dissatisfaction 5 SETUP , FPIR
User End - Fitment Insert worn out 2 Tool Change Frequency 5 50
problem
GROOVE OF DIA
55 DIST 0.6 Less stock from previous Previous operation stock
operation 2 maintaining 5 50
Next operation - Nil
Groove dist Subsquent Process - Nil
undersize Customer End - Nil 5 Insert worn out 2 Set up Approval SETUP , FPIR 5 50
User End - Fitment problem
Wrong Offset 2 Edit Key Lock 5 50

Improper setting 2 Setting Approval 5 50


Next operation - Nil
GROOVE OF DIA Subsquent Process - Nil
55 ANGLE, 40° Out of Spec Customer End - nil 5 Insert worn out 2 Tool Change Frequency SETUP , FPIR 5 50
+/-3° User End - Fitment problem
Change in Programm 2 Edit Key Lock 5 50

Next operation - Nil Change in Programm 2 Edit Key Lock 5 50


GROOVE OF DIA Subsquent Process - Nil
55 SURFACE Out of Spec Customer End - Dissatisfaction 5 Insert worn out 2 Tool Change Frequency SETUP , FPIR 5 50
FINISH User End - Metting
part issue One per day
Coolant Concentration 2 concentration checking 5 50

Less stock from previous Previous operation stock


operation 3 maintaining 4 84
Next operation - Nil
Subsquent Process - Nil FPIR, Inprocess Inspection,
Diameter oversize Customer End - Dissatisfied 7 Insert worn out 3 Tool Change Frequency 100% checked on machine 4 84
Finish OD
Turning & User End - Loose Fittment
20 Gear side Change in Programing 3 Edit Key Lock 4 84
boring DiaØ112.034+/-
0.015.
Improper setting 3 Setting Approval 4 84
Next operation - Nil
Diameter Subsquent Process - Nil FPIR, Inprocess Inspection,
undersize Customer End - Dissatisfied 7 100% checked on machine
User End - Loose Fittment Insert worn out 3 Tool Change Frequency 4 84

Change in Programing 2 Edit Key Lock 5 50


Next operation - Nil
Surface FINISH Subsquent Process - Nil Insert worn out 2 Tool Change Frequency 5 50
OF DIA 112.034 Out of Spec Customer End - Dissatisfaction 5 SETUP , FPIR
Roughness Ra 1.6 User End - Nil
One per day
Coolant Concentration 2 concentration checking 5 50

Change in Programm 2 Edit Key Lock 4 40


AXIAL RUN OUT Next operation - Nil
0.03 WRT A-B OF Runout Out Of Subsquent Process - Nil Improper setting 2 Setting Approval 4 60
FLANFE FACE spec. Customer End - Noise in Fittment 5 SETUP , FPIR
GEAR SIDE User End -
Nil Process Parameter Work
Clamping Pressure 2 Instruction 4 60

Change in Programm 3 Edit Key Lock 4 84


CIRCULAR Next operation - Nil
RUNOUT OF Runout Out Of Subsquent Process - Nil
Customer End - Noise in Fittment 7 Improper setting 3 Setting Approval SETUP , FPIR 4 84
BEARING DIA spec.
112.034 User End -
Nil Process Parameter Work
Clamping Pressure 3 Instruction 4 84
Doc. No. :FMEA/1081746-00-B
FAILURE MODE AND EFFECTS ANALYSIS Rev. No. : 00
Rev. Date :16.12.2018
ITEM HOUSING MACHINED DIFFERENTIAL, 3DU PROCESS RESPONSIBILITY : PRODUCTION HEAD
PART NO& Rev. No. 1081746-00-B3 KEY DATE : 16.12.2018
CORE TEAM Prashant Shetty, R.Gunjal,Sudhir Patil, Siddhesh,Thakur,Karna,Aman,Ranjeet
PREPARED BY Siddhesh Phalke
Concept: PROCESS FMEA
Process: MACHINING FMEA DATE (ORIG) : 05/12/2018
Operation: ALL PROCESS SUPPLIER : KRANTI INDUSTRIES LTD.
Recommended
Process Intent Process Assessment Current Process Controls Action Results
Actions
S O C Respons-
Item Critical v c Current Process control D R L ibility Actio S O D
C
R
Potential Failure Current Process Controls Recommen & Target R
Function Requirement(s) Charac Mode Potential Effect(s) or Failure r Potential Causes of Failure r Prevention
Detection E P A
ded Actions Completion ns E C E
I
P
t. t n T N S Taken V C T N
S T
y c Date

Next operation - Nil Improper setting 2 Setting Approval 5 50


SURFACE ANGLE Subsquent Process - Chamfer
10°+0/-4° Out of Spec Dimension will be affected 5 Insert worn out 2 Tool Change Frequency SETUP , FPIR 5 50
Customer End - Dissatisfaction
User End - Nil Change in Programm 2 Edit Key Lock 5 50

Change in Programing 2 Edit Key Lock 5 40


Next operation - Nil
Subsquent Process - Nil
Radius oversize Customer End -Dissatisfaction 4 Insert worn out 2 Tool Change Frequency SETUP , FPIR 5 40
User End - Nil
Improper setting 2 Setting Approval 5 40
RADIUS R5+2
Next operation - Nil Change in Programing 2 Edit Key Lock 5 40
Subsquent Process - Nil
Radius undersize Customer End -Dissatisfaction 4 Insert worn out 2 Tool Change Frequency SETUP , FPIR 5 40
User End - Nil
Improper setting 2 Setting Approval 5 40

Improper setting 2 Setting Approval 5 60


Next operation - will affect next
operation
Dist oversize Subsquent Process - Nil 6 Insert worn out 2 Tool Change Frequency SETUP , FPIR 5 60
Customer End - Fitment problem
User End - Nil
Wrong Offset 2 Edit Key Lock 5 60
DISTANCE
32.1675+/-0.05
Finish OD Improper setting 2 Setting Approval 5 60
Turning & Next operation - will affect next
20 Gear side operation Subsquent
boring Dist undersize Process - Nil Customer End 6 Insert worn out 2 Tool Change Frequency SETUP , FPIR 5 50
-Fitment problem
User End - Nil Wrong Offset 2 Edit Key Lock 5 50

Change in Programing 2 Edit Key Lock 5 50


Next operation - Nil
SURFACE FINISH Subsquent Process - Nil
OF FLANGE FACE Out of Spec Customer End - Dissatisfaction 5 Insert worn out 2 Tool Change Frequency SETUP , FPIR 5 50
Ra1.6 User End - Nil
One per day
Coolant Concentration 2 concentration checking 5 50

Change in Programing 2 Edit Key Lock 5 50

Next operation - Nil


Surface FINISH Subsquent Process - Nil Insert worn out 2 Tool Change Frequency 5 50
OF DIA 112.034 Out of Spec Customer End - Dissatisfaction 5 SETUP , FPIR
Roughness Ra 1.6 User End - Nil
One per day
Coolant Concentration 2 concentration checking 5 50
Finish OD Doc. No. :FMEA/1081746-00-B
20
Turning &
Gear side FAILURE MODE AND EFFECTS ANALYSIS Rev. No. : 00
boring
Rev. Date :16.12.2018
ITEM HOUSING MACHINED DIFFERENTIAL, 3DU PROCESS RESPONSIBILITY : PRODUCTION HEAD
PART NO& Rev. No. 1081746-00-B3 KEY DATE : 16.12.2018
CORE TEAM Prashant Shetty, R.Gunjal,Sudhir Patil, Siddhesh,Thakur,Karna,Aman,Ranjeet
PREPARED BY Siddhesh Phalke
Concept: PROCESS FMEA
Process: MACHINING FMEA DATE (ORIG) : 05/12/2018
Operation: ALL PROCESS SUPPLIER : KRANTI INDUSTRIES LTD.
Recommended
Process Intent Process Assessment Current Process Controls Action Results
Actions
S O C Respons-
Item Critical v c Current Process control D R L ibility Actio S O D
C
R
Potential Failure Current Process Controls Recommen & Target R
Function Requirement(s) Charac Mode Potential Effect(s) or Failure r Potential Causes of Failure r Prevention
Detection E P A
ded Actions Completion ns E C E
I
P
t. t n T N S Taken V C T N
S T
y c Date
Process control at Incoming Inspection
Excess Material 2 supplier & visual as per IIR 5 40
Next operation - Nil inspection
Subsquent Process - Nil
Chamfer oversize Customer End - Dissatisfaction 4 Insert worn out 2 Tool Change Frequency 5 40
Set Up Approval , FPIR
User End - Nil Standard Operating
CHAMFER OF Improper setting 2 Procedure 5 40
FLANGE 1.0 ±0.3
X45°±5°
5 40
Next operation - Nil
Subsquent Process - Nil Standard Operating 5 40
Chamfer undersize Customer End -Dissatisfaction 4 Improper setting 2 Procedure SETUP , FPIR
User End - Nil
5 40
Process control at Incoming Inspection
Excess Material 2 supplier & visual as per IIR 5 40
Next operation - Nil inspection
Subsquent Process - Nil
Dist oversize Customer End - Fitment problem 4 Insert worn out 2 Tool Change Frequency 40
User End - Nil Set Up Approval , FPIR 5
Standard Operating
DISTANCE 7.3+/- Improper setting 2 Procedure 40
0.3
Next operation - Nil 5 50
Insert worn out 2 Set up Approval
Subsquent Process - Nil
Dist undersize Customer End -Fitment problem 5 SETUP , FPIR 5 50
User End - Nil Standard Operating
Improper setting 2 Procedure 5 50
Incoming Inspection
Finish OD More Access Material 2 Report 5 40
Turning & Next operation - Nil
20 Gear side Subsquent Process - Nil
Dist oversize Customer End - Fitment problem 4 Insert worn out 2 Tool Change Frequency SETUP , FPIR 5 40
boring
DISTANCE 18+/- User End - Nil Standard Operating
Improper setting 2 Procedure 5 40
1.5
Next operation - Nil Insert worn out 2 Set up Approval 5 50
Subsquent Process - Nil
Dist undersize Customer End - Fitment problem 5 SETUP , FPIR
Standard Operating
User End - Nil Improper setting 2 Procedure 5 50
Process control at Incoming Inspection
Excess Material 2 supplier & visual as per IIR 5 40
Next operation - Nil inspection
Subsquent Process - Nil
Dist oversize Customer End - Fitment problem 4 Insert worn out 2 Tool Change Frequency 5 40
User End - Nil Set Up Approval , FPIR
Standard Operating
Improper setting 2 Procedure 5 40
DISTANCE 51.5+/-
0.1 Less stock from previous Previous operation stock
operation 2 maintaining 5 40
Next operation - Nil
Subsquent Process - Nil
Dist undersize Customer End - Fitment problem 4 Insert worn out 2 Set up Approval SETUP , FPIR 5 40
User End - Nil
Wrong Offset 2 Edit Key Lock 5 40
Doc. No. :FMEA/1081746-00-B
FAILURE MODE AND EFFECTS ANALYSIS Rev. No. : 00
Rev. Date :16.12.2018
ITEM HOUSING MACHINED DIFFERENTIAL, 3DU PROCESS RESPONSIBILITY : PRODUCTION HEAD
PART NO& Rev. No. 1081746-00-B3 KEY DATE : 16.12.2018
CORE TEAM Prashant Shetty, R.Gunjal,Sudhir Patil, Siddhesh,Thakur,Karna,Aman,Ranjeet
PREPARED BY Siddhesh Phalke
Concept: PROCESS FMEA
Process: MACHINING FMEA DATE (ORIG) : 05/12/2018
Operation: ALL PROCESS SUPPLIER : KRANTI INDUSTRIES LTD.
Recommended
Process Intent Process Assessment Current Process Controls Action Results
Actions
S O C Respons-
Item Critical v c Current Process control D R L ibility Actio S O D
C
R
Potential Failure Current Process Controls Recommen & Target R
Function Requirement(s) Charac Mode Potential Effect(s) or Failure r Potential Causes of Failure r Prevention
Detection E P A
ded Actions Completion ns E C E
I
P
t. t n T N S Taken V C T N
S T
y c Date
Process control at Incoming Inspection
Next operation - Nil Excess Material 2 supplier & visual as per IIR 5 40
Subsquent Process - Nil inspection
Chamfer oversize Customer End - Dissatisfaction 4 Insert worn out 2 Tool Change Frequency 5 40
Set Up Approval , FPIR
User End - Nil Standard Operating
CHAMFER Improper setting 2 Procedure 5 40
DIAMETER
37±0.3 5 40
Next operation - Nil
Subsquent Process - Nil Standard Operating
Chamfer undersize Customer End -Dissatisfaction 4 Improper setting 2 Procedure SETUP , FPIR 5 50
User End - Nil
5 50

Next operation - Nil Improper setting 2 Setting Approval 5 40


Subsquent Process - Chamfer
CHAMFER ANGLE Dimension will be affected
60°+/-5° Out of Spec 4 Insert worn out 2 Tool Change Frequency SETUP , FPIR 5 50
Customer End - Dissatisfaction
User End - Nil Change in Programm 2 Edit Key Lock 5 50

Change in Programing 2 Edit Key Lock 5 40


Next operation - Nil
Subsquent Process - Nil
Radius oversize Customer End -Dissatisfaction 4 Insert worn out 2 Tool Change Frequency SETUP , FPIR 5 40
User End - Nil
Improper setting 2 Setting Approval 5 40
RADIUS R2+1
Change in Programing 2 Edit Key Lock 5 40
Next operation - Nil
Subsquent Process - Nil
Radius undersize Customer End -Dissatisfaction 4 Insert worn out 2 Tool Change Frequency SETUP , FPIR 5 40

User End - Nil Improper setting 2 Setting Approval 5 40

Next operation - will affect Change in Programm 3 Edit Key Lock 4 60


Subsquent Process - Nil
Runout Out Of Customer End - Noise in Fittment
PROFILE WRT A-B spec. 5 Improper setting 3 Setting Approval SETUP , FPIR 4 60
User End -
Nil Process Parameter Work
Clamping Pressure 3 Instruction 4 60

Finish OD
Turning &
20 Gear side
boring
Doc. No. :FMEA/1081746-00-B
FAILURE MODE AND EFFECTS ANALYSIS Rev. No. : 00
Rev. Date :16.12.2018
ITEM HOUSING MACHINED DIFFERENTIAL, 3DU PROCESS RESPONSIBILITY : PRODUCTION HEAD
PART NO& Rev. No. 1081746-00-B3 KEY DATE : 16.12.2018
CORE TEAM Prashant Shetty, R.Gunjal,Sudhir Patil, Siddhesh,Thakur,Karna,Aman,Ranjeet
PREPARED BY Siddhesh Phalke
Concept: PROCESS FMEA
Process: MACHINING FMEA DATE (ORIG) : 05/12/2018
Operation: ALL PROCESS SUPPLIER : KRANTI INDUSTRIES LTD.
Recommended
Process Intent Process Assessment Current Process Controls Action Results
Actions
S O C Respons-
Item Critical v c Current Process control D R L ibility Actio S O D
C
R
Potential Failure Current Process Controls Recommen & Target R
Function Requirement(s) Charac Mode Potential Effect(s) or Failure r Potential Causes of Failure r Prevention
Detection E P A
ded Actions Completion ns E C E
I
P
t. t n T N S Taken V C T N
S T
y c Date

Less stock from previous Previous operation stock


operation 2 maintaining 5 40
Next operation - Nil
ID diameter Subsquent Process - Nil
oversize Customer End - Dissatisfaction 4 Insert worn out 2 Set up Approval SETUP , FPIR 5 60
User End - Nil Standard Operating
BACK BORE Improper setting 2 Procedure 5 60
DIAMETER
Ø47+/-0.3 Excess stock from Previous operation stock
previous operation 2 maintaining 5 40
Next operation - Nil
ID diameter under Subsquent Process - Nil Standard Operating
Finish OD size Customer End - fitment problem 4 Improper setting 2 Procedure SETUP , FPIR, IPIR 5 40
Turning & User End - Nil
20 Gear side Insert worn out 2 Set up Approval 5 40
boring
Next operation - Nil Incoming Inspection
More Access Material 2 Report 5 40
Subsquent Process - will affect
chamfer dimension
Diameter oversize Customer End - Fitment problem 4 Insert worn out 2 Tool Change Frequency SETUP , FPIR 5 40
CHAMFER Wrong Offset 2 Edit Key Lock 5 40
DIAMETER User End - Nil
Ø36.2+/-0.3
Next operation - Nil 5 50
Insert worn out 2 Set up Approval
Diameter Subsquent Process - Nil
undersize Customer End -Fitment problem 5 SETUP , FPIR
User End - Nil 5 50
Wrong Offset 2 Edit Key Lock

Improper setting 2 Setting Approval 5 50


DIA 35 BACK Next operation - Nil
CHAMFER ANGLE Subsquent Process - Nil
Out of Spec Customer End - Dissatisfaction 5 SETUP , FPIR
60°+/-5° Insert worn out 2 Tool Change Frequency 5 50
User End - Nil

Next operation -Nil Incoming Inspection


More Access Material 2 Report 5 40
Subsquent Process -Will affect the
chamfer dimension
Diameter oversize Customer End - Fitment problem 4 Insert worn out 2 Tool Change Frequency SETUP , FPIR 5 40
CHAMFER
DIAMETER User End - Nil Wrong Offset 2 Edit Key Lock 5 40
Ø48.76+/-0.3
Next operation - Nil Insert worn out 2 Set up Approval 5 40
Diameter Subsquent Process - Nil
undersize Customer End -Fitment problem 4 SETUP , FPIR
User End - Nil Wrong Offset 2 Edit Key Lock 5 50

Improper setting 2 Setting Approval 5 40


DIA 47 Next operation - Nil
CHAMFER ANGLE Subsquent Process - Nil
Out of Spec Customer End - Dissatisfaction 4 SETUP , FPIR 5 40
60°+/-5° Insert worn out 2 Tool Change Frequency
User End - Nil
5 40

Change in Programing 2 Edit Key Lock 5 40


Next operation - Nil
Subsquent Process - Nil
Radius oversize Customer End -Dissatisfaction 4 Insert worn out 2 Tool Change Frequency SETUP , FPIR 5 40
User End - Nil
Improper setting 2 Setting Approval 5 40
RADIUS R2-0.3
Next operation - Nil Change in Programing 2 Edit Key Lock 5 40
Subsquent Process - Nil
Radius undersize Customer End -Dissatisfaction 4 Insert worn out 2 Tool Change Frequency SETUP , FPIR 5 40
User End - Nil Improper setting 2 Setting Approval 5 40

PART FREE FROM Loose chips, sharp Next Operation - Nil 5 Less awareness 3 As per WI/PD/27 Visual inspection 4 60
20a DEBURRING BURR, SHARP edge present on Subsquent Process - Nil Tool life
EDGES, CHIPS component Customer End - Dissatisfaction NPD
End User - Nil 8 Deburring tool wear out 5 Tool Change Frequency Visual inspection 4 160 frequency 15.2.19
to be set
Doc. No. :FMEA/1081746-00-B
FAILURE MODE AND EFFECTS ANALYSIS Rev. No. : 00
Rev. Date :16.12.2018
ITEM HOUSING MACHINED DIFFERENTIAL, 3DU PROCESS RESPONSIBILITY : PRODUCTION HEAD
PART NO& Rev. No. 1081746-00-B3 KEY DATE : 16.12.2018
CORE TEAM Prashant Shetty, R.Gunjal,Sudhir Patil, Siddhesh,Thakur,Karna,Aman,Ranjeet
PREPARED BY Siddhesh Phalke
Concept: PROCESS FMEA
Process: MACHINING FMEA DATE (ORIG) : 05/12/2018
Operation: ALL PROCESS SUPPLIER : KRANTI INDUSTRIES LTD.
Recommended
Process Intent Process Assessment Current Process Controls Action Results
Actions
S O C Respons-
Item Critical v c Current Process control D R L ibility Actio S O D
C
R
Potential Failure Current Process Controls Recommen & Target R
Function Requirement(s) Charac Mode Potential Effect(s) or Failure r Potential Causes of Failure r Prevention
Detection E P A
ded Actions Completion ns E C E
I
P
t. t n T N S Taken V C T N
S T
y c Date

Op - 30 Finish OD Turning & bellside boring


Improper setting 4 Set up Approval 3 84
Next operation - Nil
Subsquent Process - Nil FPIR, Inprocess Inspection,
Diameter oversize Customer End - Fitment problem 7 Insert worn out 3 Tool Change Frequency 100% checked on machine 3 63
Bearing Dia. User End - Nil
Should OK Programm error 3 Edit Key Lock 5 105
Dia.Ø45.015+/-
0.01
Next operation - Nil
Subsquent Process - Nil Improper setting 4 Set up Approval 3 84
Diameter Customer End - Loose Fitment FPIR, Inprocess Inspection,
undersize 7 100% checked on machine
problem
User End - Nil Specification Of Tool 4 Toolin List 3 84

Next operation - Nil Change in Programm 3 Edit Key Lock 4 84


CIRCULAR Subsquent Process - Nil
RUNOUT 0.020 Runout Out Of Customer End - Loose Noise in Standard Operating
spec. 7 Improper setting 3 Procedure CMM REPORT, FPIR 4 84
WRT A-B Fittment/ Backlash problem
User End - Nil Standard Operating
Clamping Pressure 3 Procedure 4 84

Next operation -Nil Excess stock from Maintaing previous


previous operation 2 operation stock 5 40
Subsquent Process -Will affect the
chamfer dimension
Diameter oversize Customer End - Fitment problem 4 Insert worn out 2 Tool Change Frequency SETUP , FPIR 5 40

CHAMFER User End - Nil Improper setting 2 Setting Approval 5 40


DIAMETER
42.7±0.3 5 50
Next operation - Nil Insert worn out 2 Set up Approval
Diameter Subsquent Process - Nil
undersize Customer End -Fitment problem 5 SETUP , FPIR 5 50
User End - Nil
Wrong Offset 2 Edit Key Lock 5 50

Improper setting 2 Setting Approval 5 50


CHAMFER ANGLE Next operation - Nil
30°±5° (OF DIA Subsquent Process - Nil
Out of Spec Customer End - Dissatisfaction 5 SETUP , FPIR 5 50
45.015) Insert worn out 2 Tool Change Frequency
User End - Nil
5 50

Change in Programing 2 Edit Key Lock 5 40


Next operation - Nil
Subsquent Process - Nil
Radius oversize Customer End -Dissatisfaction 4 Insert worn out 2 Tool Change Frequency SETUP , FPIR 5 40
User End - Nil
Finish OD Improper setting 2 Setting Approval 5 40
Turning & RADIUS 1.0 - 1.5
30 bellside (OF DIA 45.01)
boring Next operation - Nil Change in Programing 2 Edit Key Lock 5 40
Subsquent Process - Nil
Radius undersize Customer End -Dissatisfaction 4 Insert worn out 2 Tool Change Frequency SETUP , FPIR 5 40
User End - Nil Improper setting 2 Setting Approval 5 40

Next operation - Nil Improper setting 2 Setting Approval 5 40


CHAMFER Subsquent Process - will leave
FLANGE 1.0±0.2 Out of Spec sharpe edge 4 SETUP , FPIR 5 40
45°±5° Customer End - Dissatisfaction Insert worn out 2 Tool Change Frequency
User End - Nil 5 40
Excess stock from Previous operation stock
previous operation 2 maintaining 5 50
Next operation - Nil
Subsquent Process - Nil
Dist oversize Customer End - Fitment problem 5 Insert worn out 2 Tool Change Frequency SETUP , FPIR, IPIR 5 50
User End - Nil
Change in Programm 2 Edit Key Lock 5 50
DISTANCE
84.6675±0.050 Previous operation stock
More Access Material 2 maintaining 5 50
Next operation - Nil
Subsquent Process - Nil
Dist undersize Customer End -Fitment Problem 5 Insert worn out 2 Set up Approval SETUP , FPIR, IPIR 5 50
User End - Nil
Change in Programm 3 Edit Key Lock 5 50
Doc. No. :FMEA/1081746-00-B
FAILURE MODE AND EFFECTS ANALYSIS Rev. No. : 00
Rev. Date :16.12.2018
ITEM HOUSING MACHINED DIFFERENTIAL, 3DU PROCESS RESPONSIBILITY : PRODUCTION HEAD
PART NO& Rev. No. 1081746-00-B3 KEY DATE : 16.12.2018
CORE TEAM Prashant Shetty, R.Gunjal,Sudhir Patil, Siddhesh,Thakur,Karna,Aman,Ranjeet
PREPARED BY Siddhesh Phalke
Concept: PROCESS FMEA
Process: MACHINING FMEA DATE (ORIG) : 05/12/2018
Operation: ALL PROCESS SUPPLIER : KRANTI INDUSTRIES LTD.
Recommended
Process Intent Process Assessment Current Process Controls Action Results
Actions
S O C Respons-
Item Critical v c Current Process control D R L ibility Actio S O D
C
R
Potential Failure Current Process Controls Recommen & Target R
Function Requirement(s) Charac Mode Potential Effect(s) or Failure r Potential Causes of Failure r Prevention
Detection E P A
ded Actions Completion ns E C E
I
P
t. t n T N S Taken V C T N
S T
y c Date

Change in Programm 3 Edit Key Lock 4 60


Next operation - Will affect
AXIAL RUNOUT Subsquent Process - Nil Standard Operating
0.030 WRT Runout Out Of Customer End - fitment problem Improper setting 3 4 60
spec. 5 Procedure CMM REPORT, FPIR
A-B
User End - Nil Process Parameter Work
Clamping Pressure 3 Instruction 4 60

Excess stock from Previous operation stock


previous operation 2 maintaining 5 40
Next operation - Nil
Subsquent Process - Nil
Dist oversize Customer End - Fitment problem 4 Insert worn out 2 Tool Change Frequency SETUP , FPIR 5 40
User End - Nil Standard Operating
Improper setting 3 Procedure 5 40
DISTANCE
75.4±0.3 Previous operation stock
More Access Material 2 maintaining 5 40
Next operation - Nil
Subsquent Process - Nil
Dist undersize Customer End -Fitment problem 4 Insert worn out 2 Set up Approval SETUP , FPIR 5 40
User End - Nil
Wrong Offset 2 Edit Key Lock 5 40

Change in Programm 2 Edit Key Lock 5 40


SURFACE FINISH Next operation - Nil
Ra1.6 Subsquent Process - Nil
(OF DIA Out of Spec Customer End - Dissatisfaction 4 Insert worn out 2 Tool Change Frequency SETUP , FPIR 5 40
45.015) User End - Nil One per day
Finish OD Coolant Concentration 2 concentration checking 5 40
Turning &
30 bellside Excess stock from Previous operation stock
previous operation 2 maintaining 5 40
boring Next operation -Nil
Subsquent Process - Nil
Radius oversize Customer End - Fitment problem 4 Insert worn out 2 Tool Change Frequency SETUP , FPIR 5 40
User End - Nil Standard Operating
Improper setting 2 Procedure 5 40
RADIUS R 2.0+1
(OF DIA. 64) Previous operation stock
More Access Material 2 maintaining 5 40
Next operation - Nil
Subsquent Process - Nil
Radius undersize Customer End -Fitment problem 4 Insert worn out 2 Tool Change Frequency SETUP , FPIR 5 40
User End - Nil Standard Operating
Improper setting 2 Procedure 5 40
Excess stock from Previous operation stock
previous operation 3 maintaining 5 60
Next operation - Will affect
Subsquent Process - Nil
Length oversize Customer End - Fitment problem 4 Insert worn out 3 Tool Change Frequency SETUP , FPIR 5 60
User End - Nil Standard Operating
Improper setting 3 Procedure 5 60
LENGTH
109.5±0.1 Previous operation stock
Less material allowance 3 maintaining 5 60
Next operation - Will affect
Subsquent Process - Nil Insert worn out 3 Set up Approval 5 60
Length undersize Customer End -Fitment problem 4 SETUP , FPIR
User End - Nil Standard Operating
Improper setting 3 Procedure 5 60
Doc. No. :FMEA/1081746-00-B
FAILURE MODE AND EFFECTS ANALYSIS Rev. No. : 00
Rev. Date :16.12.2018
ITEM HOUSING MACHINED DIFFERENTIAL, 3DU PROCESS RESPONSIBILITY : PRODUCTION HEAD
PART NO& Rev. No. 1081746-00-B3 KEY DATE : 16.12.2018
CORE TEAM Prashant Shetty, R.Gunjal,Sudhir Patil, Siddhesh,Thakur,Karna,Aman,Ranjeet
PREPARED BY Siddhesh Phalke
Concept: PROCESS FMEA
Process: MACHINING FMEA DATE (ORIG) : 05/12/2018
Operation: ALL PROCESS SUPPLIER : KRANTI INDUSTRIES LTD.
Recommended
Process Intent Process Assessment Current Process Controls Action Results
Actions
S O C Respons-
Item Critical v c Current Process control D R L ibility Actio S O D
C
R
Potential Failure Current Process Controls Recommen & Target R
Function Requirement(s) Charac Mode Potential Effect(s) or Failure r Potential Causes of Failure r Prevention
Detection E P A
ded Actions Completion ns E C E
I
P
t. t n T N S Taken V C T N
S T
y c Date

Excess stock from Previous operation stock


previous operation 2 maintaining 5 40
Next operation - Will affect
Subsquent Process - Nil
Length oversize Customer End - Fitment problem 4 Insert worn out 2 Tool Change Frequency SETUP , FPIR 5 40
User End - Nil Standard Operating
Improper setting 3 Procedure 5 40
TOTAL LENGTH
161.0±0.1 Previous operation stock
Less material allowance 2 maintaining 5 50
Next operation - Nil
Subsquent Process - Nil
Length undersize Customer End -Fitment problem 5 Insert worn out 3 Set up Approval SETUP , FPIR 5 60
User End - Nil Standard Operating
Improper setting 2 Procedure 5 50

Change in Programm 3 Edit Key Lock 5 75


SURFACE FINISH Next operation - Nil
OF FLANGE FACE Subsquent Process - Nil
Out of Spec Customer End - Dissatisfaction 5 Insert worn out 2 Tool Change Frequency SETUP , FPIR 5 50
BELL SIDE Ra3.2
User End - Nil One per day
Coolant Concentration 2 concentration checking 5 50

Next operation -Nil Excess stock from Maintaing previous


previous operation 2 operation stock 5 40
Subsquent Process -Will affect the
chamfer dimension
Diameter oversize Customer End - Fitment problem 4 Insert worn out 2 Tool Change Frequency SETUP , FPIR 5 40
Standard Operating
CHAMFER User End - Nil Improper setting 3 Procedure 5 60
DIAMETER
37±0.3 5 40
Next operation - Nil Insert worn out 2 Set up Approval
Diameter Subsquent Process - Nil
undersize Customer End -Fitment problem 4 SETUP , FPIR 5 50
User End - Nil
Wrong Offset 2 Edit Key Lock 5 50
Less stock from previous Previous operation stock
operation 2 maintaining 5 80
Next operation - Nil FPIR, Inprocess
Subsquent Process - Nil Inspection,100% checked on
Diameter oversize Customer End - Fitment problem 8 Insert worn out 2 Tool Change Frequency 5 80
machine
User End - Nil
Change in Programing 2 Edit Key Lock 5 80
Dia. Ø35.046+/-
0.01 Bell side Standard Operating
Improper setting 2 Procedure 5 80
Next operation - Part loading Issue
Diameter Subsquent Process - Nil FPIR, Inprocess
Customer End - Loose 8 Inspection,100% checked on 5 80
undersize
Fitment problem Insert worn out 2 Tool Change Frequency machine
User End - Nil
5 80

Change in Programm 3 Edit Key Lock 4 60


TOTAL RUNOUT Next operation - Nil
0.080 W.R.T. A - Runout Out Of Subsquent Process - Nil Standard Operating
spec. Customer End - Noise in Fittment 5 Improper setting 3 Procedure CMM REPORT, FPIR 4 60
B (OF DIA 35.04)
User End - Nil Process Parameter Work
Clamping Pressure 3 Instruction 4 60
Doc. No. :FMEA/1081746-00-B
FAILURE MODE AND EFFECTS ANALYSIS Rev. No. : 00
Rev. Date :16.12.2018
ITEM HOUSING MACHINED DIFFERENTIAL, 3DU PROCESS RESPONSIBILITY : PRODUCTION HEAD
PART NO& Rev. No. 1081746-00-B3 KEY DATE : 16.12.2018
CORE TEAM Prashant Shetty, R.Gunjal,Sudhir Patil, Siddhesh,Thakur,Karna,Aman,Ranjeet
PREPARED BY Siddhesh Phalke
Concept: PROCESS FMEA
Process: MACHINING FMEA DATE (ORIG) : 05/12/2018
Operation: ALL PROCESS SUPPLIER : KRANTI INDUSTRIES LTD.
Recommended
Process Intent Process Assessment Current Process Controls Action Results
Actions
S O C Respons-
Item Critical v c Current Process control D R L ibility Actio S O D
C
R
Potential Failure Current Process Controls Recommen & Target R
Function Requirement(s) Charac Mode Potential Effect(s) or Failure r Potential Causes of Failure r Prevention
Detection E P A
ded Actions Completion ns E C E
I
P
t. t n T N S Taken V C T N
S T
y c Date

Change in Programm 3 Edit Key Lock 4 60


Next operation - Nil
RUNOUT OF DIA Runout Out Of Subsquent Process - Nil
156 spec. Customer End - Noise in Fittment 5 Improper setting 3 Setting Approval CMM REPORT, FPIR 4 60
User End - Nil Process Parameter Work
Clamping Pressure 3 Instruction 4 60
Less stock from previous Previous operation stock
operation 2 maintaining 6 60
Next operation - Nil
ID diameter Subsquent Process - Nil SETUP , FPIR, 100% checked by
oversize Customer End - Nil 5 Insert worn out 2 Set up Approval PPG 6 60
User End - Nil Standard Operating
Improper setting 3 Procedure 6 90
BACK BORE
DIAMETER 47 Excess stock from Previous operation stock
Next operation - Nil previous operation 2 maintaining 6 60
Subsquent Process - Nil
ID diameter under Customer End - Loose Fitment Standard Operating SETUP , FPIR, 100% checked by
size 5 Improper setting 3 Procedure PPG 6 90
Finish OD problem
Turning & User End - Nil Insert worn out 2 Set up Approval 6 60
bellside
boring Excess stock from Previous operation stock
previous operation 2 maintaining 5 40
Next operation - Nil
Subsquent Process -Will affect
Depth oversize Customer End - Fitment problem 4 Insert worn out 2 Set up Approval SETUP , FPIR 5 40
User End - Nil Standard Operating
Improper setting 3 Procedure 5 60
DEPTH
7.5+/-0.1 Incoming Inspection
Next operation - Machining More Access Material 2 5 40
operation Affected less Report
margine/unclean of surface
Depth undersize Subsquent Process - Nil 4 Insert worn out 2 Set up Approval SETUP , FPIR 5 40
Customer End -Nil
User End - Nil Wrong Offset 2 Edit Key Lock 5 40

Next operation - Nil Excess stock from Maintaing previous


previous operation 2 operation stock 5 40
Subsquent Process - will affect
chamfer dimension
Diameter oversize Customer End - Fitment problem 4 Insert worn out 2 Tool Change Frequency SETUP , FPIR 5 40

CHAMFER User End - Nil Wrong Offset 2 Edit Key Lock 5 40


DIAMETER
Ø36.2+/-0.3 5 40
Next operation - Nil Insert worn out 2 Set up Approval
Diameter Subsquent Process - Nil
undersize Customer End -Fitment problem 4 SETUP , FPIR 5 40
User End - Nil
Wrong Offset 2 Edit Key Lock 5 40

Improper setting 2 Setting Approval 5 50


DIA 35 BACK Next operation - Nil
CHAMFER ANGLE Subsquent Process - Nil
Out of Spec Customer End - Dissatisfaction 5 SETUP , FPIR 5 50
60°+/-5° Insert worn out 2 Tool Change Frequency
User End - Nil
5 50
Doc. No. :FMEA/1081746-00-B
FAILURE MODE AND EFFECTS ANALYSIS Rev. No. : 00
Rev. Date :16.12.2018
ITEM HOUSING MACHINED DIFFERENTIAL, 3DU PROCESS RESPONSIBILITY : PRODUCTION HEAD
PART NO& Rev. No. 1081746-00-B3 KEY DATE : 16.12.2018
CORE TEAM Prashant Shetty, R.Gunjal,Sudhir Patil, Siddhesh,Thakur,Karna,Aman,Ranjeet
PREPARED BY Siddhesh Phalke
Concept: PROCESS FMEA
Process: MACHINING FMEA DATE (ORIG) : 05/12/2018
Operation: ALL PROCESS SUPPLIER : KRANTI INDUSTRIES LTD.
Recommended
Process Intent Process Assessment Current Process Controls Action Results
Actions
S O C Respons-
Item Critical v c Current Process control D R L ibility Actio S O D
C
R
Potential Failure Current Process Controls Recommen & Target R
Function Requirement(s) Charac Mode Potential Effect(s) or Failure r Potential Causes of Failure r Prevention
Detection E P A
ded Actions Completion ns E C E
I
P
t. t n T N S Taken V C T N
S T
y c Date
Process control at Incoming Inspection
Next operation - Nil Excess Material 2 supplier & visual as per IIR 6 48
Subsquent Process - Nil inspection
Chamfer oversize Customer End - Dissatisfaction 4 Insert worn out 2 Tool Change Frequency 5 40
Set Up Approval , FPIR
User End - Nil Standard Operating
CHAMFER Improper setting 2 Procedure 5 40
DIAMETER
Ø48.76+/-0.3 5 50
Next operation - Nil
Subsquent Process - Nil Standard Operating
Chamfer undersize Customer End -Dissatisfaction 5 Improper setting 2 Procedure SETUP , FPIR 5 50
User End - Nil
5 50

Improper setting 2 Setting Approval 5 50


DIA 47 Next operation - Nil
CHAMFER ANGLE Subsquent Process - Nil
Out of Spec Customer End - Dissatisfaction 5 SETUP , FPIR 5 50
60°+/-5° Insert worn out 2 Tool Change Frequency
User End - Nil
5 50
Excess stock from Previous operation stock
previous operation 2 maintaining 5 40
Next operation -Nil
Subsquent Process - Nil
Radius oversize Customer End - Fitment problem 4 Insert worn out 2 Tool Change Frequency SETUP , FPIR 5 40
User End - Nil Standard Operating
Improper setting 3 Procedure 5 60
RADIUS R 2.0+1
(OF DIA. 64) Previous operation stock
More Access Material 2 maintaining 5 50
Next operation - Nil
Subsquent Process - Nil
Radius undersize Customer End -Fitment problem 5 Insert worn out 2 Tool Change Frequency SETUP , FPIR 5 50
User End - Nil Standard Operating
Improper setting 2 Procedure 5 50

Next operation - Will affect Change in Programm 3 Edit Key Lock 4 72


AXIAL RUN OUT Subsquent Process - Nil
0.03 WRT A-B OF Runout Out Of Customer End - fitment problem Standard Operating
spec. 6 Improper setting 3 Procedure CMM REPORT, FPIR 4 72
FACE DIA 45.01
User End - Nil Process Parameter Work
Clamping Pressure 3 Instruction 4 72

Change in Programm 3 Edit Key Lock 4 60


TOTAL RUNOUT Next operation - Nil
0.080 W.R.T. A - Runout Out Of Subsquent Process - Nil
spec. Customer End - Fitment problem 5 Improper setting 3 Setting Approval CMM REPORT, FPIR 4 60
B (OF DIA 35.04)
User End - Nil Process Parameter Work
Clamping Pressure 3 Instruction 4 60

Change in Programm 3 Edit Key Lock 4 60


CIRCULAR Next operation - Nil
RUNOUT 0.080 Runout Out Of Subsquent Process - Nil
spec. Customer End - Fitment problem 5 Improper setting 3 Setting Approval CMM REPORT, FPIR 4 60
W.R.T. A-B
User End - Nil Process Parameter Work
Clamping Pressure 3 Instruction 4 60

Change in Programm 3 Edit Key Lock 4 60


CIRCULER Next operation - Nil
Finish OD RUNOUT 0.03 Subsquent Process - Nil
Turning & Runout Out Of Improper setting 3 Setting Approval 4 60
W.R.T. A-B (OF spec. Customer End - Fitment problem 5 CMM REPORT, FPIR
bellside BEARING DIA. User End -
boring 120.035) Nil Process Parameter Work
Clamping Pressure 3 Instruction 4 60

Improper setting 2 Setting Approval 5 50


CHAMFER ANGLE Next operation - Nil
60°±5° Subsquent Process - Nil
Out of Spec Customer End - Dissatisfaction 5 SETUP , FPIR 5 50
(OF DIA 35.04) Insert worn out 2 Tool Change Frequency
User End - Nil
5 50

Change in Programm 2 Edit Key Lock 5 50


Next operation - Nil
SURFACE FINISH Subsquent Process - Nil
Ra 1.6 Out of Spec 5 Insert worn out 2 Tool Change Frequency SETUP , FPIR 5 50
Customer End - Dissatisfaction
(OF DIA 35.04) User End - Nil
Improper setting 2 Setting Approval 5 50
Doc. No. :FMEA/1081746-00-B
FAILURE MODE AND EFFECTS ANALYSIS Rev. No. : 00
Rev. Date :16.12.2018
ITEM HOUSING MACHINED DIFFERENTIAL, 3DU PROCESS RESPONSIBILITY : PRODUCTION HEAD
PART NO& Rev. No. 1081746-00-B3 KEY DATE : 16.12.2018
CORE TEAM Prashant Shetty, R.Gunjal,Sudhir Patil, Siddhesh,Thakur,Karna,Aman,Ranjeet
PREPARED BY Siddhesh Phalke
Concept: PROCESS FMEA
Process: MACHINING FMEA DATE (ORIG) : 05/12/2018
Operation: ALL PROCESS SUPPLIER : KRANTI INDUSTRIES LTD.
Recommended
Process Intent Process Assessment Current Process Controls Action Results
Actions
S O C Respons-
Item Critical v c Current Process control D R L ibility Actio S O D
C
R
Potential Failure Current Process Controls Recommen & Target R
Function Requirement(s) Charac Mode Potential Effect(s) or Failure r Potential Causes of Failure r Prevention
Detection E P A
ded Actions Completion ns E C E
I
P
t. t n T N S Taken V C T N
S T
y c Date

Op - 40Cross hole boring, spherical & Back face.


Improper setting 2 Set up Approval 5 60
Next operation - Nil
Subsquent Process - Nil FPIR, Inprocess Inspection,
Diameter oversize Customer End - Fitment problem 6 Insert worn out 2 Tool Change Frequency 100% checked on machine 5 60
User End - Nil
Hole Dia. Should Programm error 2 Edit Key Lock 5 60
OK Dia. Ø5.43+/-
0.05 UPTO P Insert worn out 2 Tool Change Frequency 5 60
Next operation - Will affect
Diameter Subsquent Process - Nil FPIR, Inprocess Inspection,
undersize Customer End - Fitment problem 6 Improper setting 3 Set up Approval 100% checked on machine 5 90
User End - Nil
Change in Programm 3 Edit Key Lock 5 90

Next operation - Nil Change in Programm 3 Edit Key Lock 4 60


POSITION OF Subsquent Process - Nil
GUNDRILL 0.1 Position Out Of Customer End - Fitment problem
spec. 5 Improper setting 3 Setting Approval CMM REPORT, FPIR 4 60
WRT A-B, C, P User End -
Nil Process Parameter Work
Clamping Pressure 3 Instruction 4 60
Excess stock from Maintaing previous
previous operation 2 operation stock 5 40
DISTANCE Next operation - Nil
34.90(CROSS Oversize / Subsquent Process - Nil CMM REPORT, FPIR, 100%
undersize Customer End - Fitment problem 4 Insert worn out 2 Tool Change Frequency checked on multigauging 5 40
HOLE TO FACE E)
User End - Nil
Improper setting 3 Setting Approval 5 60

Next operation - Nil Change in Programm 3 Edit Key Lock 4 60


AXIAL RUNOUT Subsquent Process - Nil
FACE E 0.05 wrt Runout Out Of Customer End - Noise in Fittment
spec. 5 Improper setting 3 Setting Approval CMM REPORT, FPIR 4 60
A-B User End -
Nil Standard Operating
Clamping Pressure 3 Procedure 4 60
Incoming Inspection
More Access Material 2 Report 5 40
DISTANCE Next operation - Nilt
34.90(CROSS Oversize / Subsquent Process - Nil CMM REPORT, FPIR, 100%
undersize Customer End - Fitment problem 4 Insert worn out 2 Tool Change Frequency checked on multigauging 5 40
HOLE TO FACE C)
User End - Nil
Wrong Offset 2 Edit Key Lock 5 40

Next operation - Nil Change in Programm 3 Edit Key Lock 4 48


AXIAL RUNOUT Subsquent Process - Nil
FACE E 0.05 wrt Runout Out Of Customer End - Noise in Fittment
spec. 4 Improper setting 3 Setting Approval CMM REPORT, FPIR 4 48
A-B User End -
Nil Standard Operating
Clamping Pressure 3 Procedure 4 48
Doc. No. :FMEA/1081746-00-B
FAILURE MODE AND EFFECTS ANALYSIS Rev. No. : 00
Rev. Date :16.12.2018
ITEM HOUSING MACHINED DIFFERENTIAL, 3DU PROCESS RESPONSIBILITY : PRODUCTION HEAD
PART NO& Rev. No. 1081746-00-B3 KEY DATE : 16.12.2018
CORE TEAM Prashant Shetty, R.Gunjal,Sudhir Patil, Siddhesh,Thakur,Karna,Aman,Ranjeet
PREPARED BY Siddhesh Phalke
Concept: PROCESS FMEA
Process: MACHINING FMEA DATE (ORIG) : 05/12/2018
Operation: ALL PROCESS SUPPLIER : KRANTI INDUSTRIES LTD.
Recommended
Process Intent Process Assessment Current Process Controls Action Results
Actions
S O C Respons-
Item Critical v c Current Process control D R L ibility Actio S O D
C
R
Potential Failure Current Process Controls Recommen & Target R
Function Requirement(s) Charac Mode Potential Effect(s) or Failure r Potential Causes of Failure r Prevention
Detection E P A
ded Actions Completion ns E C E
I
P
t. t n T N S Taken V C T N
S T
y c Date

Next operation - Nil Change in Programm 2 Edit Key Lock 4 32


Subsquent Process - Nil
AXIAL RUNOUT Runout Out Of Customer End - Noise in Fittment
FACE C spec. 4 Improper setting 2 Setting Approval CMM REPORT, FPIR 4 32
User End -
Nil Standard Operating
Clamping Pressure 2 Procedure 4 32
Excess stock from Maintaing previous
previous operation 3 operation stock 5 60
Machining Next operation - Will affect
Dimensions Oversize / Subsquent Process - Nil
should OK - undersize Customer End - Fitment problem 4 Insert worn out 2 Tool Change Frequency CMM REPORT, FPIR 5 40
29.5+/-0.05, User End - Nil
Improper setting 2 Setting Approval 5 40

Next operation - Nil Change in Programm 3 Edit Key Lock 4 60


Subsquent Process - Nil
Sphere 94.080+/- Oversize / Customer End - Fitment problem
0.1 undersize 5 Improper setting 3 Setting Approval CMM REPORT, FPIR 4 60
User End -
Nil Insert worn out 2 Tool Change Frequency 4 40

Next operation - Nil Change in Programm 3 Edit Key Lock 4 60


SPHERE Subsquent Process - Nil
POSITION WRT Position Out Of Customer End - Fitment problem
spec. 5 Improper setting 3 Setting Approval CMM REPORT, FPIR 4 60
( A-B) ( P-R ) User End -
Nil Standard Operating
Clamping Pressure 3 Procedure 4 60

Program error 2 Edit Key Lock 5 50


SURFACE FINISH Next operation - Nil
OF SPHERICAL Subsquent Process - Nil
Out of Spec Customer End - Dissatisfaction 5 Insert worn out 2 Tool Change Frequency FPIR, Inprocess Inspection 5 50
RADIUS
User End - Nil
Improper setting 2 Setting Approval 5 50
Excess stock from Maintaing previous
previous operation 2 operation stock 5 40
Machining Next operation - Nilt
Dimensions Oversize / Subsquent Process - Nil
should OK - undersize Customer End - Fitment problem 4 Insert worn out 2 Tool Change Frequency FPIR, Inprocess Inspection 5 40
51.05+/-0.1, User End - Nil
Improper setting 2 Setting Approval 5 40

Next operation - Nil Change in Programm 3 Edit Key Lock 4 60


Subsquent Process - Nil
TOTAL RUNOUT Runout Out Of Customer End - Noise in Fittment
OF DIA 35.04 spec. 5 Improper setting 3 Setting Approval CMM REPORT, FPIR 4 60
User End -
Nil Process Parameter Work
Clamping Pressure 3 Instruction 4 60

Cross hole
Doc. No. :FMEA/1081746-00-B
FAILURE MODE AND EFFECTS ANALYSIS Rev. No. : 00
Rev. Date :16.12.2018
ITEM HOUSING MACHINED DIFFERENTIAL, 3DU PROCESS RESPONSIBILITY : PRODUCTION HEAD
PART NO& Rev. No. 1081746-00-B3 KEY DATE : 16.12.2018
CORE TEAM Prashant Shetty, R.Gunjal,Sudhir Patil, Siddhesh,Thakur,Karna,Aman,Ranjeet
PREPARED BY Siddhesh Phalke
Concept: PROCESS FMEA
Process: MACHINING FMEA DATE (ORIG) : 05/12/2018
Operation: ALL PROCESS SUPPLIER : KRANTI INDUSTRIES LTD.
Recommended
Process Intent Process Assessment Current Process Controls Action Results
Actions
S O C Respons-
Item Critical v c Current Process control D R L ibility Actio S O D
C
R
Potential Failure Current Process Controls Recommen & Target R
Function Requirement(s) Charac Mode Potential Effect(s) or Failure r Potential Causes of Failure r Prevention
Detection E P A
ded Actions Completion ns E C E
I
P
t. t n T N S Taken V C T N
S T
y c Date

Next operation - Nil Change in Program 2 Edit Key Lock 4 40


Subsquent Process - Nil
RUNOUT OF DIA Runout Out Of Customer End - Noise in Fittment
156 spec. 5 Improper setting 2 Setting Approval CMM REPORT, FPIR 4 40
User End -
Nil Process Parameter Work
Clamping Pressure 2 Instruction 4 40

Improper setting 3 Setting Approval 4 84


Next operation - Nil
Subsquent Process - Nil FPIR, Inprocess Inspection,
Diameter oversize Customer End - Fitment problem 7 Insert worn out 3 Tool Change Frequency 100% inspection on machine 4 84
User End - Nil
Hole Dia. Should Change in Program 3 Edit Key Lock 4 84
OK Dia.
Ø19.494+/-0.013 wrong offset Given 3 Edit Key Lock 4 84
Next operation - Nil
Cross hole Subsquent Process - Nil
Diameter Customer End - Loose Fitment FPIR, Inprocess Inspection,
boring, undersize 7 Improper setting 2 Set up Approval 100% inspection on machine 4 56
40 problem
spherical &
User End - Nil Insert worn out 3 Tool Change Frequency 4 84
Back face. POSITION
0.13WITHIN
SPECIFICATION
w.r.t. A-B-C, Improper setting 2 Setting Approval 5 70
Next operation - Nil
Subsquent Process - Nil FPIR, Inprocess Inspection,
Out of Spec Customer End - Fitment Problem 7 cmm report
User End - Nil
Insert worn out 2 Tool Change Frequency 5 70

Improper setting 2 Setting Approval 5 40


Next operation - Nil
POSITION 1.0 Subsquent Process - Nil FPIR, Inprocess Inspection,
WRT YZ Out of Spec Customer End - Fitment Problem 4 Insert worn out 2 Tool Change Frequency cmm report 6 48
PARELLALISM User End - Nil
WITHIN Wrong Offset 2 Edit Key Lock 5 40
SPECIFICATION
0.05 w.r.t. 'D', E, Next operation - Nil Change in Programm 3 Edit Key Lock 4 60
Subsquent Process - Nil
Parallalism Out Of Customer End - Fitment problem
spec. 5 Improper setting 2 Setting Approval FPIR, Inprocess Inspection 5 50
User End -
Nil Standard Operating
Clamping Pressure 2 Procedure 5 50
Excess stock from Maintaing previous
previous operation 2 operation stock 5 40
Machining Next operation - Nil
Dimensions Oversize / Subsquent Process - Nil
should OK - undersize Customer End - Fitment problem 4 Insert worn out 2 Tool Change Frequency FPIR, Inprocess Inspection 5 40
56.5±0.3 User End - Nil
Improper setting 2 Setting Approval 5 40
Cross hole
40
boring,
spherical &
Back face.

Doc. No. :FMEA/1081746-00-B


FAILURE MODE AND EFFECTS ANALYSIS Rev. No. : 00
Rev. Date :16.12.2018
ITEM HOUSING MACHINED DIFFERENTIAL, 3DU PROCESS RESPONSIBILITY : PRODUCTION HEAD
PART NO& Rev. No. 1081746-00-B3 KEY DATE : 16.12.2018
CORE TEAM Prashant Shetty, R.Gunjal,Sudhir Patil, Siddhesh,Thakur,Karna,Aman,Ranjeet
PREPARED BY Siddhesh Phalke
Concept: PROCESS FMEA
Process: MACHINING FMEA DATE (ORIG) : 05/12/2018
Operation: ALL PROCESS SUPPLIER : KRANTI INDUSTRIES LTD.
Recommended
Process Intent Process Assessment Current Process Controls Action Results
Actions
S O C Respons-
Item Critical v c Current Process control D R L ibility Actio S O D
C
R
Potential Failure Current Process Controls Recommen & Target R
Function Requirement(s) Charac Mode Potential Effect(s) or Failure r Potential Causes of Failure r Prevention
Detection E P A
ded Actions Completion ns E C E
I
P
t. t n T N S Taken V C T N
S T
y c Date

Change in Programm 3 Edit Key Lock 5 75


Next operation - Nil
SURFACE FINISH Subsquent Process - Nil
OF C/H Out of Spec Customer End - Dissatisfaction 5 Insert worn out 2 Tool Change Frequency FPIR, Inprocess Inspection 5 50
User End - Nil
Improper setting 2 Setting Approval 5 50
Excess stock from Maintaing previous
previous operation 2 operation stock 6 36
Machining Next operation - Nil
Dimensions Oversize / Subsquent Process - Nil
should OK - undersize Customer End - Fitment problem 3 Insert worn out 2 Tool Change Frequency FPIR, Inprocess Inspection 5 30
56.5±0.3 User End - Nil
Improper setting 2 Setting Approval 5 40
Excess stock from Maintaing previous
previous operation 2 operation stock 5 40
Next operation - Nil
Sharpe edge not Subsquent Process - Nil
0.8 MAX CORNER removed Customer End - Fitment problem 4 Insert worn out 2 Tool Change Frequency 100% VISUAL 5 40
User End - Nil
Wrong Offset 2 Edit Key Lock 5 40

Change in Programm 3 Edit Key Lock 5 75


Next operation - Nil
SURFACE FINISH Subsquent Process - Nil
OF C/H Out of Spec Customer End - Dissatisfaction 5 Insert worn out 2 Tool Change Frequency FPIR, Inprocess Inspection 5 50
User End - Nil
Improper setting 2 Setting Approval 5 50

Improper setting 3 Setting Approval 4 84


Next operation - Nil
Subsquent Process - Nil FPIR, Inprocess Inspection,
Diameter oversize Customer End - Fitment problem 7 Insert worn out 3 Tool Change Frequency 100% inspection on machine 4 84
User End - Nil
Hole Dia. Should Change in Program 3 Edit Key Lock 4 84
OK Dia.
Ø19.397±0.013 wrong offset Given 2 Edit Key Lock 5 70
Next operation - Nil
Subsquent Process - Nil
Diameter Customer End - Loose Fitment FPIR, Inprocess Inspection,
undersize 7 Improper setting 2 Set up Approval 100% inspection on machine 5 70
problem
User End - Nil Insert worn out 3 Tool Change Frequency 5 70

Change in Program 2 Edit Key Lock 5 70


Next operation - Nil CMM REPORT, FPIR, 100%
CONCENTRICITY Concentricity Out Subsquent Process - Nil checked by concentricity
Ø0.02 w.r.t.' P' Of spec. Customer End - Fitment problem 7 Improper setting 2 Setting Approval 5 70
mandrell
User End - Nil Standard Operating
Clamping Pressure 2 Procedure 5 70

Improper setting 2 Setting Approval 5 50


Next operation - Nil
CHAMFER ANGLE Subsquent Process - Nil
90° Out of Spec Customer End - Dissatisfaction 5 SETUP , FPIR 5 50
User End - Nil Insert worn out 2 Tool Change Frequency
5 50
Doc. No. :FMEA/1081746-00-B
FAILURE MODE AND EFFECTS ANALYSIS Rev. No. : 00
Rev. Date :16.12.2018
ITEM HOUSING MACHINED DIFFERENTIAL, 3DU PROCESS RESPONSIBILITY : PRODUCTION HEAD
PART NO& Rev. No. 1081746-00-B3 KEY DATE : 16.12.2018
CORE TEAM Prashant Shetty, R.Gunjal,Sudhir Patil, Siddhesh,Thakur,Karna,Aman,Ranjeet
PREPARED BY Siddhesh Phalke
Concept: PROCESS FMEA
Process: MACHINING FMEA DATE (ORIG) : 05/12/2018
Operation: ALL PROCESS SUPPLIER : KRANTI INDUSTRIES LTD.
Recommended
Process Intent Process Assessment Current Process Controls Action Results
Actions
S O C Respons-
Item Critical v c Current Process control D R L ibility Actio S O D
C
R
Potential Failure Current Process Controls Recommen & Target R
Function Requirement(s) Charac Mode Potential Effect(s) or Failure r Potential Causes of Failure r Prevention
Detection E P A
ded Actions Completion ns E C E
I
P
t. t n T N S Taken V C T N
S T
y c Date

Specification Of Tool 2 Tooling List 5 30


Next operation - Nil
Subsquent Process - Nil
Diameter oversize Customer End - Fitment problem 3 Insert worn out 2 Tool Change Frequency SETUP , FPIR 5 30
User End - Nil
Chamfer Dia. Programm error 2 Edit Key Lock 5 30
Should OK Dia.
Ø48.2+/-0.2 wrong offset Given 3 Edit Key Lock 5 45
Next operation - Nil
Subsquent Process - Nil
Diameter Customer End - Loose Fitment
undersize 3 Improper setting 3 Set up Approval SETUP , FPIR 5 90
problem
User End - Nil Specification Of Tool 3 Toolin List 5 90

Improper setting 2 Setting Approval 6 60


Next operation - Nil
CHAMFER ANGLE Subsquent Process - Nil
OF DIA 47 Out of Spec Customer End - Dissatisfaction 5 SETUP , FPIR
User End - Nil Insert worn out 2 Tool Change Frequency 6 60

Next operation - Machining Excess stock from Maintaing previous


previous operation 2 operation stock 5 40
Machining operation Affected Tool wear out
Dimensions Subsquent Process -
Out of Spec Nil Customer End - Fitment 4 Insert worn out 2 Tool Change Frequency SETUP , FPIR,CMM REPORT 5 40
should OK - 7+/-1
problem User
End - Nil Improper setting 2 Setting Approval 5 40

5 Less awareness 3 As per WI/PD/27 Visual inspection 4 60


PART FREE FROM Loose chips, sharp Next Operation - Nil
40a DEBURRING BURR, SHARP edge present on Subsquent Process - Nil Tool life
EDGES, CHIPS component Customer End - Dissatisfaction NPD
End User - Nil 5 Deburring tool wear out 8 Tool Change Frequency Visual inspection 4 160 frequency
to be set 15.2.19

2D Barcode marking &


Matrix Laser
Scanning as per Wrong Etching Part serail number not 2D marking verification 100% inspection with scan cam
45
marking & /missing Customer End - Dissatishfaction 5 traceable 4 with scanning at washing & final 3 60
Scanning SOP
Doc. No. :FMEA/1081746-00-B
FAILURE MODE AND EFFECTS ANALYSIS Rev. No. : 00
Rev. Date :16.12.2018
ITEM HOUSING MACHINED DIFFERENTIAL, 3DU PROCESS RESPONSIBILITY : PRODUCTION HEAD
PART NO& Rev. No. 1081746-00-B3 KEY DATE : 16.12.2018
CORE TEAM Prashant Shetty, R.Gunjal,Sudhir Patil, Siddhesh,Thakur,Karna,Aman,Ranjeet
PREPARED BY Siddhesh Phalke
Concept: PROCESS FMEA
Process: MACHINING FMEA DATE (ORIG) : 05/12/2018
Operation: ALL PROCESS SUPPLIER : KRANTI INDUSTRIES LTD.
Recommended
Process Intent Process Assessment Current Process Controls Action Results
Actions
S O C Respons-
Item Critical v c Current Process control D R L ibility Actio S O D
C
R
Potential Failure Current Process Controls Recommen & Target R
Function Requirement(s) Charac Mode Potential Effect(s) or Failure r Potential Causes of Failure r Prevention
Detection E P A
ded Actions Completion ns E C E
I
P
t. t n T N S Taken V C T N
S T
y c Date

OP - 50 Drilling & Tapping


Next operation - Nil Improper setting 2 Set up Approval 3 42
Subsquent Process - Nil FPIR, Inprocess Inspection,
Over size Customer End - Fitment problem 7 Insert worn out 2 Tool Change Frequency First & last tap in final 3 42
User End - Nil inspection
Programm error 2 Edit Key Lock 3 42
Insert worn out 2 Tool Change Frequency 3 42
Next operation - Nil
Subsquent Process - Nil Improper setting 3 Set up Approval FPIR, Inprocess Inspection, 3 63
M10x 1.5 @ ONE Under size Customer End - Fitment problem 7 First & last tap in final
PLACE ,TAP M10 User End - Disatisfication Standard Operating inspection
AT 15 PLACES Wrong tool use 2 Procedure 3 42

Power cut off 1 Power back up 3 24


Next operation - Nil
Subsquent Process - Nil FPIR, Inprocess Inspection,
Missing Customer End - Fitment problem 8 100% visual inspection
Programm error 1 Edit Key Lock 3 24
User End - Nil

Next operation - Nil Programm error 3 Edit Key Lock 3 36


Over size Subsquent Process - Nil FPIR, Inprocess Inspection,
M10 PCD Improper setting 3 Set up Approval 3 36
Customer End - Loose Fitment 4 100% checked on PCD at final
DIAMETER 136 problem station
Standard Operating
Under size User End - Disatisfication Wrong tool use 3 Procedure 3 36

Specification Of Tool 2 Tooling List 5 50


Next operation - Nil
Subsquent Process - Nil FPIR, Inprocess Inspection,
Diameter oversize Customer End - Fitment problem 5 Insert worn out 2 Tool Change Frequency 100% checked on final station 5 60
User End - Nil
Programm error 2 Edit Key Lock 5 60
DIA 5.1 + 0.1
wrong offset Given 3 Edit Key Lock 5 75
Next operation - Nil
Diameter Subsquent Process - Nil
undersize Customer End - Fitment problem 5 Improper setting 3 Set up Approval FPIR, Inprocess Inspection 5 75
Drilling &
50 Tapping User End - Nil
Specification Of Tool 3 Toolin List 5 75
Excess stock from Maintaing previous
Machining previous operation 2 operation stock 5 40
Dimensions Next operation - Nilt
should OK - Subsquent Process - Nil Insert worn out 2 Tool Change Frequency 5 40
51.05+/-0.1, Out of Spec Customer End - Fitment problem 4 FPIR, Inprocess Inspection
( FOR DIA 5+/- User End - Nil
0.1) Programm error 2 Edit Key Lock 5 40

Improper setting 2 Setting Approval 5 50


Angle should OK Next operation - Nil
22.5°+/- Subsquent Process - Nil
Out of Spec Customer End - Fitment Problem 5 Insert worn out 2 Tool Change Frequency CMM REPORT, FPIR 5 50
0°30
User End - Nil
Wrong Offset 2 Edit Key Lock 5 50

Improper setting 2 Setting Approval 5 50


Angle should OK Next operation - Nil
Subsquent Process - Nil
Out of Spec Customer End - Fitment Problem 5 Insert worn out 2 Tool Change Frequency CMM REPORT, FPIR 5 50
11.30°±0°30
User End - Nil
Wrong Offset 2 Edit Key Lock 5 50
Drilling & Doc. No. :FMEA/1081746-00-B
50 Tapping FAILURE MODE AND EFFECTS ANALYSIS Rev. No. : 00
Rev. Date :16.12.2018
ITEM HOUSING MACHINED DIFFERENTIAL, 3DU PROCESS RESPONSIBILITY : PRODUCTION HEAD
PART NO& Rev. No. 1081746-00-B3 KEY DATE : 16.12.2018
CORE TEAM Prashant Shetty, R.Gunjal,Sudhir Patil, Siddhesh,Thakur,Karna,Aman,Ranjeet
PREPARED BY Siddhesh Phalke
Concept: PROCESS FMEA
Process: MACHINING FMEA DATE (ORIG) : 05/12/2018
Operation: ALL PROCESS SUPPLIER : KRANTI INDUSTRIES LTD.
Recommended
Process Intent Process Assessment Current Process Controls Action Results
Actions
S O C Respons-
Item Critical v c Current Process control D R L ibility Actio S O D
C
R
Potential Failure Current Process Controls Recommen & Target R
Function Requirement(s) Charac Mode Potential Effect(s) or Failure r Potential Causes of Failure r Prevention
Detection E P A
ded Actions Completion ns E C E
I
P
t. t n T N S Taken V C T N
S T
y c Date

Improper setting 2 Setting Approval 5 50


Next operation - Nil
Angle should OK Subsquent Process - Nil
11X90° Out of Spec Customer End - Fitment Problem 5 Insert worn out 2 Tool Change Frequency CMM REPORT, FPIR 5 50
User End - Nil
Wrong Offset 2 Edit Key Lock 5 50

Next operation - Nil Change in Programm 3 Edit Key Lock 4 60


Subsquent Process - Nil
Position Ø0.15 Position Out Of Customer End - Fitment problem
w.r.t. A-B, C, P, spec. 5 Improper setting 3 Setting Approval CMM REPORT, FPIR 4 60
User End -
Nil Process Parameter Work
Clamping Pressure 3 Instruction 4 60

All dimension Parameter not Proper gauging/ Corelation activity per 15 Defective parts highlighted
Multi Gauging
60
100% should be with in ok / skipped Customer End - Dissatishfaction 5 co-rrelation study 3 days with red colour on screen 4 60
specification

Defect sheet displayed on


Free from visual Lack of awareness, Lack work station , daily defect 100% Visual inspection, Dock
Visual
70
Inspection defects Defect Missing Customer End - Dissatishfaction 5 of knowledge on visual 3 monitoring, daily shift audit after packing. 4 60
defects, meeting

WASHING AS PER
WASHING W.I Work Instruction, daily
Washing skipped,
80 OILING & OILING & Run incomplete cycle Customer End - Dissatishfaction 4 RUSTY / UNCLEAN/ 3 check sheet Process audit 4 48
PACKING PACKING AS PER
W.I

PDI (QF/QA/26) WRONG CALIBERATION


FINAl
90
INSPECTION AS PER INSPECTION Customer End - Dissatishfaction 5 Improper Calibration 3 FREQUENCY DECIDED & 5 per lot 4 60
SPECIFICATION MINITORED

PART STORAGE WRONG AREA IDENTIFICATION/ PART STORE AS PER PACKING


STORAGE/
100
DISPATCH DESPATCH AS LOCATION Customer End - Dissatishfaction 5 INVENTORY 3 WI/ Daily inventory STANDARD 4 60
PER STANDARD DELAY 100%

Revision Change Note

Revision Number: Date of Revision : Reason Of Change Change Detail

0 05.12.2018 New Drawing Released New part

PREPARED BY : Siddhesh Phalke APPROVED BY : Prashant shetty