4 Manual
4 Manual
*WBV.PU.002.EN*
WBV.PU.002.EN V3.1
2010-02-15 1/52
Copyright © *WBV.PU.002.EN* WBV.PU.002.EN V3.1
Operating and Maintenance Manual (Original)
Rotary Lobe Pump
VX100Q, VX136Q/186Q, VX136QD/VX186QD, VX136QDR, VX136QD/VX186QD Marathon www.vogelsang.info
Pos: 3 /Inhaltsverzeichnis @ 0\mod_1108563026452_48.doc @ 947 @
Contents
Dear customer,
By buying this Vogelsang rotary lobe pump, you have
acquired a high quality product. If you want your pump to
function reliably over a long period of time, it has to be
serviced at regular intervals, as stipulated in the instructions.
Therefore, this manual should be at the disposal of the
operators and maintenance personnel at all times and they
should adhere to the manual carefully.
Our operating and maintenance manuals are updated at regular intervals. With your improvement proposals,
you would help us make this manual more user-friendly.
Please fax your proposals to our design department +49 5434 83 10, or e-mail krampe@vogelsang-
gmbh.com.
Notes
Legend of symbols
1 Intended Use
Pos: 9 /WBV/Pumpen/Verwendungszweck/Verwendungszweck Pumpen @ 0\mod_1117525944414_48.doc @ 3073 @
2 Safety Notes
Pos: 11 /WBV/Pumpen/Sicherheitshinweise/Sicherheitshinweise vor Inbetriebnahme @ 28\mod_1212737720135_48.doc @ 92773 @
Before start-up
• Read and follow the operating and safety notes carefully.
• Familiarise yourself with all facilities and operating options.
• Note all the items in the "Checklist before start-up" in the "Start-up" chapter.
• Ensure that access to rotating parts is not possible.
Safety devices
Drive
Attention! Before carrying out maintenance and repair work, switch off the drive.
Ensure that the drive cannot be switched on by mistake.
Pos: 18 /WBV/Pumpen/Sicherheitshinweise/Warnhinweis - Ringschrauben @ 32\mod_1228470611925_48.doc @ 110074 @
Use the lifting eye bolts* on the pumps only for lifting the pump without mounting
parts (for example, the motor)! See chapter on "Transport".
VX136QD / VX186QD
Fig. 1: Position of warning and safety labels
(The figures are examples, only. The exact position of labels may deviate.)
3 Assembly
Pos: 24 /Überschriften für Inhaltsverzeichnis /Überschrift 2 /Transport @ 11\mod_1172823145915_48.doc @ 38086 @ 2
3.1 Transport
Pos: 25 /Grafiken/Pumpen/WBV/Montage/Transporthilfen VX Pumpen @ 35\mod_1240839474783_48.doc @ 120223 @
If the pumps are transported in suspension, use the fitted suspension points for hoisting gear, see fig.
"Transport aids".
Use the lifting eye bolts on the pumps only for lifting the pump without mounting
parts (for example, the motor)!
* Max. permissible weight with one lifting eye bolt M8: 140 kg
Max. permissible weight with one lifting eye bolt M12: 340 kg
Max. permissible weight with two lifting eye bolts M12: 480 kg
(At an angle of attack up to 45°)
Pos: 29 /---Seitenumbruch--- @ 21\mod_1201696136229_0.doc @ 80575 @
Retighten all motor and pump mounting screws on the base after 20 operating hours.
Pos: 33 /WBV/Pumpen/Montage/Wartungshinweis Riemenantrieb @ 20\mod_1198072387981_48.doc @ 78479 @
For pumps with belt drive check the belt tension acc. to 'accompanying sheet':
• at start-up
• before and after longer out-of-service periods
• after the first 10 operating hours
• every 2000 operating hours, once per year minimum
Pos: 34 /WBV/Pumpen/Sicherheitshinweise/Warnhinweis - Ringschrauben @ 32\mod_1228470611925_48.doc @ 110074 @
Use the lifting eye bolts* on the pumps only for lifting the pump without mounting
parts (for example, the motor)! See chapter on "Transport".
Ensure that the pump is free of constraints while installation and while operating, too.
Pos: 39 /Überschriften für Inhaltsverzeichnis /Überschrift 2 /Einbau in Pumpanlagen und Fahrzeugen @ 2\mod_1133871789554_48.doc @ 6210 @ 2
3.4 Installing the rotary lobe pump in pump systems and vehicles
Pos: 40 /WBV/Pumpen/Montage/Einbau in Pumpanlagen und Fahrzeugen @ 0\mod_1111398029202_48.doc @ 1628 @
• When installing the pump, ensure that there is easy access for maintenance work. If the hex head
screw plugs for draining the gearbox oil and buffer/quenching fluid are not easy to reach, drain hoses
may be used (part-no. PBT.013 and/or PBT.014).
• The connectors must be mounted free from stresses. In other words, the connectors have to be
exactly one in front of the other even without screws.
• May be installed either upright or horizontally.
• Position the pressure and suction connections pointing upwards. This will ensure that the fluid remains
in the pump after it is switched off.
• If the pump is installed horizontally, position the suction side facing downwards.
• If the pump is to be suspended, please contact us.
Important! Connector with sight glass may only be installed on suction side.
Do not exceed the maximum suction height of 8 m (26.2 ft). This is the maximum
distance between the lowest and highest points of the suction pipe.
If the diameter of the suction pipe is too small, the maximum suction height will be
reduced by the friction loss.
Please contact us for a calculation.
Pos: 41 /WBV/Pumpen/Info/Drehkolbenpumpen in senkrechter Anordnung @ 40\mod_1266232052100_48.doc @ 157774 @
For rotary lobe pumps in vertical arrangement please note our technical information
TINF.PU.019.xx.
Pos: 42 /Überschriften für Inhaltsverzeichnis /Überschrift 2 /Rohrleitungen und Nenndrücke @ 0\mod_1109926883420_48.doc @ 1203 @ 2
Only use the pipeline diameters, wall thicknesses and materials recommended by us or by our
representatives. This is essential for ensuring that the system functions properly!
Warning! Suction lines whose diameter is too small may restrict the suction
capability of the pump (risk of cavitation).
Long suction lines must be laid with a slope of at least 2 x pipe diameter in the direction of flow, ensuring that
the pipeline can never run dry.
Pos: 47 /Grafiken/Pumpen/WBV/Montage/neu- Lange Saugleitungen @ 16\mod_1186662657115_48.doc @ 59423 @
Pos: 48 /Überschriften für Inhaltsverzeichnis /Überschrift 2 /Temperatur- und Drucküberwachung @ 0\mod_1109926995708_48.doc @ 1213 @ 2
For running pumps with automatic mechanism, a temperature and pressure monitoring unit (optionally
available from Vogelsang) is required. See also point on "Safety devices" in the chapter on "Safety
instructions".
Pos: 50 /---Seitenumbruch--- @ 21\mod_1201696136229_0.doc @ 80575 @
4 Start-up
Pos: 52 /Überschriften für Inhaltsverzeichnis /Überschrift 2 /Checkliste vor Inbetriebnahme @ 26\mod_1212393300130_48.doc @ 91833 @ 2
Pos: 54 /Überschriften für Inhaltsverzeichnis /Überschrift 2 /Vor Inbetriebnahme bei längerer Lagerdauer/Außerbetriebnahme @ 0\mod_1109927062645_48.doc @ 1218 @ 2
The rotary lobe pump is essentially suitable for use in either direction of motion.
If you are using motor-driven pump (such as an electrically powered motor, hydraulic motor) with one drive
shaft, select the direction of rotation by determining the direction of the drive motor.
Pos: 62 /Grafiken/Pumpen/WBV/Förderrichtung/Motorantrieb @ 0\mod_1112779983937_48.doc @ 2226 @
In general, rotary lobe pumps can be designed for variable frequency drive operation.
Advantages:
Adaptation to operating conditions (viscosity, delivery rate, NPSHA)
Wear compensation
Speed proportional delivery rate (see characteristic line)
If you are using tractor driven pumps with two drive shafts, connect either the upper or lower the cardan
shafts thus determining the direction of flow.
To avoid shearing of drive shaft, for example by foreign matter in the pumps:
• The operating torque must be limited to 1600 Nm for cardan shafts with 1 3/8" profile, 6-parts
• The operating torque must be limited to 3200 Nm for cardan shafts with 1 3/4" profile, 6-parts and with
1 3/4" profile, 20-parts.
The pressure and suction sides are rigidly defined by the rotation of the pumps.
If you are having suction difficulties, you can temporarily fill the suction line by reversing pump direction.
However, this cannot be done with pipelines that are secured by means of check valves / non-return valves.
Keep the pipes as free as possible from foreign objects such as stones, wood
residues, etc.
Foreign objects These foreign objects lead to increased wear of the rotary lobes and the pump
housing segments.
When using the pump for viscous sludges or slurries, depending on the liquid /
Highly viscous liquids sludge being pumped, the pump speed must be reduced according to the fluid's
viscosity. This prevents cavitation from occurring.
If there is a risk of frost, the pump must be drained by dry running the pump in
either direction, until all liquid is drained out of the pump. Therefore you may
Wintertime operation use the drain valves in the connectors. For a complete draining you must
remove the cover.
Warning! Before start-up, fill up with liquid again.
During hot weather, gas may form in closed pipe systems. Because of higher
Periods of hot weather pressures, this gas may damage the pump or pumping systems.
Prevent the medium from becoming trapped in the pump.
Drain the pump by opening the cover and flush if necessary, for example in
Removing from service case of critical medium.
Pos: 80 /---Seitenumbruch--- @ 21\mod_1201696136229_0.doc @ 80575 @
7 Maintenance
Pos: 82 /Überschriften für Inhaltsverzeichnis /Überschrift 2 /Sperr-/Quenchflüssigkeit @ 1\mod_1130399040600_48.doc @ 5490 @ 2
For rotary lobe pumps in vertical arrangement please note our technical information
TINF.PU.019.xx.
Please check your order confirmation to see if your pump is filled with a buffer/quenching fluid not on the
following table. If that is the case, use this buffer/quenching fluid only.
Do not use oils for pumps with EPDM O-rings, silicone oil excepted.
In case of dry buffer chamber do not fill the pump with any fluid.
For standard pumps the following oils are recommended to ensure optimum function of the mechanical
seals:
Pos: 86 /WBV/Pumpen/Wartung/Sperrkammer/VX/Sperr-/Quenchflüssigkeit - Tabelle Öle @ 24\mod_1207561715268_48.doc @ 87873 @
Hydraulic oil Renolin B15 VG46 Alternatively: Hydraulic oil Plantohyd 40N
Part no. BSS.014 biodegradable
Part no. BSS.016
Setting up
First remove the plug from the buffer chamber. Then completely fill the buffer chamber.
After that, screw the tank directly into the casting of the buffer chamber. Fill the tank until about 1/4. Then set
the expected tank pressure with a manual pump or a compressed air supply.
Tank pressure
The tank pressure should be about 0.5 bar higher than the middle pressure in the pump.
Tank pressure = 0.5 bar + (pressure on the suction side + pressure on the pressure side) / 2.
Example:
One pump primes with 0.4 bar under pressure and presses with 2.0 bar overpressure.
Pressure on the suction side: – 0.4 bar, pressure on the pressure side: 2.0 bar.
( 0.4bar 2bar )
Tank pressure = 0.5 bar + = 1.3 bar
2
Tank pressure is 1.3 bar.
However the tank pressure should be max. 5 bar.
Trouble indication
After a possible running period, trouble with the sealing system would be directly noticed in form of:
strong pollution of the buffer fluid in the tank
escape of buffer fluid (tank is empty)
increasing of buffer fluid (tank is full)
Refilling
First depressurize the buffer chamber through the air valve. Then unscrew the upper housing (hold the union
nut tight while avoid loosening the lower screw connection – see picture below). After that fill the buffer fluid
in the tank. Finally reset the pressure. (see fig. "Fill buffer chamber").
Change of lobes
Before changing the lobes, depressurize the buffer chamber and prime it again after changing.
Fig. 11: Pump with quenching fluid tank, without pressure valve
Pos: 96 /---Seitenumbruch--- @ 21\mod_1201696136229_0.doc @ 80575 @
Fig. 12: Pump with pressure valve, without buffer fluid tank
7.1.2.4 Pump with plug (for special designs, only, for example submersible pumps)
Remove the upper plug (instead of pressure valve) for filling shortages in quantities into the buffer chamber.
(Buffer fluid level: see fig. "Pump with pressure valve, without buffer fluid tank").
Food grade oil (white oil) can be used in the gear box – part. No. BSS.010 as gear oil.
Warning!
Pumps with dry buffer chamber sealing system must not run dry!
Before start-up remove plug from vent screw (5). Before putting into operation the
pump must completely be filled up with liquid.
Assembly:
The buffer chamber tank (3) with connecting pipe (4) is connected under the buffer chamber housing. The
tank must be installed below the buffer chamber to collect possible leakage. The level of liquid in the buffer
chamber tank is allowed to reach maximum up to the bottom of the buffer chamber, see fig. "Installation
example - dry buffer chamber".
1 Wing nut
2 Wrap nut
3 Buffer chamber tank
4 Connection pipe
5 Vent screw
Pos: 102 /WBV/Pumpen/Wartung/Sperrkammer/Sperrkammeraufbau - Pumpe mit Zirkulationssystem an der Sperrkammer @ 26\mod_1212144414144_48.doc @ 91799 @ 4
Procedure:
In case of buffer chamber assemblies with a pressurised buffer fluid tank or pressure valve, always
depressurize the buffer chamber before draining or cleaning.
Unscrew buffer chamber assemblies (see chapter "Buffer chamber assemblies").
Undo the lower hex head screw plug (pos. 6 in fig. "Pump with quenching fluid tank, without pressure
valve) and drain the buffer/quenching fluid out of the buffer chamber.
Clean the buffer chamber in the event of severe contamination.
Screw the lower hex head screw plug back in (tightening torque = 60 Nm) and install the various buffer
chamber assemblies in reverse order.
If the bottom hex head screw plug is not accessible from the installation position, an extended
connection can be installed at the side on request.
Pos: 106 /WBV/Pumpen/Info/Drehkolbenpumpen in senkrechter Anordnung @ 40\mod_1266232052100_48.doc @ 157774 @
For rotary lobe pumps in vertical arrangement please note our technical
information TINF.PU.019.xx.
Changing the quenching oil has to be carried out after changing the gearbox oil.
The oil should be checked and filled up (when the gearbox is not running):
• every 500 operating hours, however not more than 3 months between fill ups.
fill the oil until it reaches the control opening [C].
Lubricant:
VOGELSANG standard oil
Mineral oil Titan Gear MP90
SAE 90
Combustion point: 215°C
Art-No. BSS.006
If you need other lubricants, please ask us for a table (TINF lubricants) of alternative oils.
Pos: 110 /WBV/Pumpen/Wartung/Getriebe/VX/Getriebeölwechsel (Ölmenge und Getriebeaufbau) VX-Pumpen @ 35\mod_1240839964939_48.doc @ 120240 @
**For rotary lobe pumps in vertical arrangement please note our technical
information TINF.PU.019.xx.
Hex head screw plug (Pos.1) always mounted on the top of the pump, magnetic hex head screw plug
(Pos.2) on the bottom of the pump.
Pos: 111 /Grafiken/Pumpen/WBV/Wartung/Getriebe/VX Getriebeölwechsel @ 35\mod_1240913331890_48.doc @ 120293 @
VX100:
horizontal installation stationary installation
VX136/VX186:
horizontal installation stationary installation
Grease nipples are primarily used for long-fibred media, for example in agriculture or biogas plants. They
can be retrofitted upon request.
The sealing prechamber can be greased through the grease nipples (if applicable) (see fig. "Changing the
gearbox oil")
Lubrication prevents the fibrous matter from hardening and adversely affecting the function of the axial seal.
• At start up
• Before and after a longer period of removing from service (2-3 weeks)
Lubricant
High-quality lubricant for rotary lobe pumps
Renolit GP2
NLGI class 2, water resistant
Art no. BSS.008
Qty
Grease nipple (gearbox side): 5 shots per nipple with a lube gun
Grease nipple (at the VX186 QD cover):
Pos: 116 /---Seitenumbruch--- @ 21\mod_1201696136229_0.doc @ 80575 @
6 shots per nipple with a lube gun
8 Repair
Pos: 118 /Überschriften für Inhaltsverzeichnis /Überschrift 2 /Umbau und Ersatzteile @ 10\mod_1169557096682_48.doc @ 29989 @ 2
Modifications or changes to the unit are only permissible after consultation with the manufacturer. Only spare
parts approved by the manufacturer or original spare parts can be used. The use of other parts invalidates
the guarantee for any resulting damage.
Pos: 120 /WBV/Pumpen/Sicherheitshinweise/Warnhinweis - Pumpen von gefährlichen Stoffen @ 16\mod_1180509156970_48.doc @ 51853 @
For installation/disassembly tools (tool sets) for the change of lobe or cartridge
mechanical seal, please refer to the corresponding spare parts lists.
8.2 Opening the cover plate for Q pumps (such as QDR-cover plate)
Pos: 125 /WBV/Pumpen/Instandsetzung/VX/Öffnen des Deckels bei Q VX100/136/186 und QDR @ 0\mod_1118400895499_48.doc @ 3250 @
Pos: 126 /Überschriften für Inhaltsverzeichnis /Überschrift 2 /Öffnen des Deckels bei QD Pumpen und QD Marathon Pumpen @ 0\mod_1109928355048_48.doc @ 1268 @ 2
1 Screw/threaded rod
2 Hex head screw plug
3 Strain screw
4 Thread
VX136QD VX186QD
Fig. 15: Open/Close the QD-cover plate
Pos: 129 /---Seitenumbruch--- @ 21\mod_1201696136229_0.doc @ 80575 @
See fig. "Disassembling of separation plates (for Marathon) and rotary lobe change"
VX136Q
VX100Q/VX186Q
Fig. 19: Position of pressure disk and spring washer in the lobe of VX136Q or VX100Q/VX186Q pumps
Pos: 145 /Überschriften für Inhaltsverzeichnis /Überschrift 3 /Zusatzteile bei VX100QVVA und VX136QVVA-Pumpen @ 24\mod_1207211912283_48.doc @ 87641 @ 3
VVA = All parts of the pump which are in contact with the medium are
stainless steel components.
Pos: 147 /WBV/Pumpen/Instandsetzung/VX/Zusatzteile VX136Q VVA-Pumpen @ 1\mod_1130410814586_48.doc @ 5588 @
An additional ring seal, including pressure disk and spring washers, protects the lobe core.
Pos: 148 /Überschriften für Inhaltsverzeichnis /Überschrift 3 /Zusatzteile bei VX 186 Q VVA-Pumpen @ 0\mod_1109929586985_48.doc @ 1328 @ 3
There are two wear plates between the cover plate and O-ring:
one wear plate at the cover plate side
one wear plate at the lobe side with two holes in the shaft area
An additional sealing ring, including pressure disk and spring washers, protects the lobe core.
Pos: 150 /---Seitenumbruch--- @ 21\mod_1201696136229_0.doc @ 80575 @
Attention! The wear plates have a defined curve. During installation, the
installation position of the wear plate must be observed. (see fig. "Installation
position of the curved wear plates")
VX100:
Pos: 154 /WBV/Pumpen/Instandsetzung/VX/Anziehdrehmoment Schutzplattenschrauben VX100: 20 Nm @ 24\mod_1207647011419_48.doc @ 88237 @
VX136/VX186:
Pos: 156 /WBV/Pumpen/Instandsetzung/VX/Anziehdrehmoment Schutzplattenschrauben VX136/VX186: 40 Nm @ 15\mod_1183451421372_48.doc @ 56455 @
(1) Wear plate on the gearbox (2) Wear plate on the cover
(3) Hex head screw with microencapsulation
Fig. 20: Installation position of the curved wear plates
Pos: 158 /---Seitenumbruch--- @ 21\mod_1201696136229_0.doc @ 80575 @
a) b)
c) d)
Fig. 21: Cartridge mechanical seal disassembly on the gearbox
Pos: 164 /---Seitenumbruch--- @ 21\mod_1201696136229_0.doc @ 80575 @
1. Carry out the work steps as detailed in chapter "Opening the cover plate for QD/QD Marathon-pumps".
(see figure "Cartridge mechanical seal disassembly on the gearbox" - a) and b)
2. Put on cartridge installation tool (D) and screw the hexagonal socket screws (b) into the borings of the
cartridge.
3. Pull off cartridge evenly by the means of the three hex head screws (c) for the cartridge installation
tool.
4. Remove retaining ring, O-ring carrier and O-rings
5. Loosen the hex head screws and washers on the bearing cover and remove the bearing cover.
(see fig. "Cartridge mechanical seal assembly on the QD cover")
6. Place washer (2) on the hex head screw (3) and push this through the cover.
7. Change O-ring in the bearing seal housing.
8. Clean the cartridge seat in the housing.
9. Insert the new cartridge.
10. Put on tool G with the large boring facing the cartridge.
11. Insert tool F in tool G.
12. Slowly tighten the cartridge by tightening hex head screw (3).
13. Remove tools F and G.
14. Fit O-ring carrier, O-rings and retaining ring.
15. Remove the hex head screw (3).
16. Close the QD cover as detailed in chapter "Closing the cover plate for QD/QD Marathon-pumps".
Pos: 166 /Grafiken/QuickMix/WBV/Instandsetzung/Cartridge-Gleitringdichtungswechsel/Cartridge-Gleitringdichtungswechsel am QD-Deckel Pumpe/QuickMix @ 39\mod_1260453249825_48.doc @ 149071 @
1 Hex nut
2 Washer
3 Hex head screw
F Tool WKZ0119
G Tool WKZ0098
In addition to the parts for changing the lobe and wear plate, the following parts have to be removed
(see fig. "Component mechanical seal change").
The remaining parts have to be installed in reverse sequence. Before installing the lobes, clean the spot
faces of sealing components and lobes carefully.
Pos: 170 /WBV/Pumpen/Instandsetzung/VX/Info-Hinweis Sonderdichtung @ 0\mod_1116414394498_48.doc @ 2750 @
Should the pump housing shells wear out, they can be readjusted.
• loosen the connector parts and screws at the pump housing segments.
• unscrew the cover plate.
• adjust the dowel pins in the housing segments as shown in fig. "Adjustment of housing segments"
• screw on all screws at the pump and the connector parts such as the cover plate.
Please note: Before installation apply the sealing material 'Curil' on every housing segment and seal them
with asbestos-free gaskets.
Pos: 176 /Grafiken/Pumpen/WBV/Instandsetzung/Nachstellen der Gehäusehalbschalen @ 0\mod_1117619241226_48.doc @ 3139 @
Increasing the gap between the lobes and wear plate at the cover:
Place the shims on the four distance nuts of the cover.
If more than two shims are placed on each distance nut, you have to lay a thicker O-ring under the pump
cover to attain continued reliable sealing.
In case of wear on lobes and plates, the gaps can be reduced accordingly again.
VX186Q
Gearbox side: Wear plate PFL.A017.T1 (5 mm) replaces wear plate PFL.A017 (6 mm)
Cover side: Wear plate PFL.A002.T1 (4 mm) replaces wear plate PFL.A002 (5 mm)
VX186Q
Gearbox side: Wear plate PFL.A017.T2 (5.7 mm) replaces wear plate PFL.A017 (6 mm)
Cover side: Wear plate PFL.A002.T2 (4.7 mm) replaces wear plate PFL.A002 (5 mm)
Pos: 181 /---Seitenumbruch--- @ 21\mod_1201696136229_0.doc @ 80575 @
minimum
Start-up*
10 Service Plan
Pos: 186 /WBV/Pumpen/Serviceplan/VX/Serviceplan VX136/186 @ 1\mod_1130925598550_48.doc @ 5719 @
Warranty is valid only when service intervals acc. to chapter "Service instructions in tabular form" have been
followed and performed.
Pump number:
Operating hours
Total capacity
Other Date Name Signature
11 Trouble-shooting
Pos: 189 /WBV/Pumpen/TroubleShooting/Hilfestellung bei Einsatzproblemen @ 25\mod_1210238379638_48.doc @ 90959 @
Dry buffer chamber: Buffer chamber tank is filled more than a half
Extreme pressure and level changes in the buffer chamber
Pressure and level variations in the buffer chamber
Suction flow breaks away after start
Dry buffer chamber: Buffer chamber tank is filled more than a half
Extreme pressure and level changes in the buffer chamber
Pressure and level variations in the buffer chamber
Suction flow breaks away after start
12 Specifications
Pos: 192 /Überschriften für Inhaltsverzeichnis /Überschrift 2 /Werkstoffbeschreibung für elastomerbeschichtete Drehkolben @ 31\mod_1223632681942_48.doc @ 105333 @ 2
Please consult us
when operating pure material lobes with media containing foreign material,
if you should discover discrepancies or if precise media data has not been
provided,
* if you require combinations with high pressure and high temperatures
Pos: 194 /WBV/Pumpen/Technische Daten/Elastomere und Werkstoffe @ 13\mod_1179217836237_48.doc @ 50317 @
Pump size of series Theoretical capacity* Max. operating Theoretical operating torque with
V100QHD/VX100Q nmax = 1000 [rpm] pressure** max. operating pressure and
water
(valid for NBR elastomers)
ALU***
[l/rev] [l/min] [m3/h] [bar] [Nm]
[bar]
45 0.29 290 20 10 7 65
64 0.42 420 25 9 5 80
90 0.59 590 35 7 3 90
* All data are as to theoretical capacity. The actual capacity depends on the various operating
conditions.
** Valid only for short operation times. For continuous operation, please contact our technicians. The
service life of the rotary lobes is reduced by high temperatures, especially in combination with high
pressure.
*** Please note the reduced max. operating pressure for pumps with gearbox housing made of
aluminium.
Pos: 199 /---Seitenumbruch--- @ 21\mod_1201696136229_0.doc @ 80575 @
pump motor
AEM0269 AEM0270
nominal power [kW] nominal power [kW]
2.2 4
speed [min-1] speed [min-1]
1420 1440
ratio [i] ratio [i]
1.913 2.19 2.526 1.913 2.19 2.526
-1
VX100.. speed [min ] 742 648 562 753 658 570
displacement [l/r]
0.29
45Q max. operating
[bar] 2.0 3.0 4.0 6.7 8.5 9.7
pressure**
theoretical capacity* [m³/h] 12.9 11.3 9.8 13.1 11.4 9.9
displacement [l/r]
0.42
64Q max. operating
[bar] 1.1 1.8 2.4 4.3 5.6 6.8
pressure**
theoretical capacity* [m³/h] 18.7 16.3 14.2 19.0 16.6 14.4
displacement [l/r]
0.59
90Q max. operating
[bar] -- -- -- 2.8 3.6 4.5
pressure**
theoretical capacity* [m³/h] -- -- -- 26.7 23.3 20.2
displacement [l/r]
0.84
128Q max. operating
[bar] -- -- -- 1.7 2.3 2.9
pressure**
theoretical capacity* [m³/h] -- -- -- 38.0 33.2 28.7
Pos: 202 /WBV/Pumpen/Technische Daten/VX/Technische Daten - Unterpunkt - VX136/186/R @ 13\mod_1179218395643_48.doc @ 50361 @
* All data are as to theoretical capacity. The actual capacity depends on the various operating
conditions.
** Valid only for short operation times. For continuous operation, please contact our technicians.
The service life of the rotary lobes is reduced by high temperatures, especially in combination with
high pressure.
Ball diameter:
Maximum ball diameter: Ø 20 mm.
Pump size of series: Theoretical Max. operating pressure** Theoretical operating torque with
capacity* max. operating pressure and
water
VX..QD VX..Q VX..QD VX..QD VX..Q VX...QD
nmax = 800 rpm 1)
VX136
VX136QD VX..QDR Marathon VX..QDR1) Marathon
Marathon 3
[l/rev] [m /h] [bar] [bar] [bar] [Nm] [Nm] [Nm]
140 12 280
70 1.27 60 10 16 240 400
(70/ 70) 5 1) 135 1)
210 12 415
105 1.90 90 10 16 355 580
(105/105) 5 1) 200 1)
280 12 550
140 2.53 120 8 14 390 675
(140/140) 5 1) 260 1)
420 10 695
210 3.80 180 5 12 395 860
(210/210) 5 1) 3801)
8 755
280 - 5.06 240 - - - -
5 1) 500 1)
6 865
420 - 7.59 360 - - - -
- -
1)
techn. data for QDR pumps
Pos: 207 /WBV/Pumpen/Technische Daten/VX/Technische Daten - Unterpunkt - VX136/186/R @ 13\mod_1179218395643_48.doc @ 50361 @
* All data are as to theoretical capacity. The actual capacity depends on the various operating
conditions.
** Valid only for short operation times. For continuous operation, please contact our technicians.
The service life of the rotary lobes is reduced by high temperatures, especially in combination with
high pressure.
Pump size of series: Theoretical Max. operating pressure** Theoretical operating torque with
capacity* max. operating pressure and water
nmax = 600 rpm VX..QD VX..Q VX...QD VX..QD VX..Q VX..QD
VX186QD Marathon Marathon
VX186
Marathon 3
[l/rev] [m /h] [bar] [bar] [bar] [Nm] [Nm] [Nm]
184
92 3.56 125 - 10 16 - 675 1100
( 92/ 92)
260
130 5.03 180 12 10 16 1100 940 1510
(130/130)
368
184 7.12 250 12 8 14 1540 1090 1850
(184/184)
520
260 10.06 360 10 5 12 1835 1035 2205
(260/260)
368 - 14.24 510 8 3 - 2100 970 -
* All data are as to theoretical capacity. The actual capacity depends on the various operating
conditions.
** Valid only for short operation times. For continuous operation, please contact our technicians.
The service life of the rotary lobes is reduced by high temperatures, especially in combination with
high pressure.
13 Declaration of Installation
Pos: 216 /Einbauerklärung/Einbauerklärung - Drehkolbenpumpen @ 39\mod_1261044232985_48.doc @ 149643 @
Hugo Vogelsang,
Maschinenbau GmbH
Holthöge 10-14
49632 Essen (Oldb.), Germany
We declare that this delivery concerns the following machine which is not complete. The machine must not
be put into service until the machinery into which this incomplete machine is incorporated is in conformity
with the Machinery Directive 2006/42/EC.
The special technical documents according to annex VII B have been prepared and can if necessary be
obtained from:
Ms Ilona Ballmann at Hugo Vogelsang Maschinenbau GmbH, D-49632 Essen (Oldb.), Germany
The basic health and safety requirements according to Annex I of the above-mentioned directive are applied
and observed.