LP 16
LP 16
Precaution
Please ensure the scale has been placed on a is level, strong and stable platform,
otherwise may cause the equipment to fall, cause equipment damage, or even
cause a fire or electric shock hazard.
Don’t put the scale in the bad environment, otherwise it will affect the normal use
and shorten the scale service life:
1. Moisture, dust, heat, cold, vibration environment;
2. Direct sunshine, strong magnetic field, strong electric field, and high pressure
or close to the motor or other will produce high temperature and high pressure
environment.
Don't bent power cord sharply, power cord should not be placed in easy be
trampled place, don't put heavy object on the power cord, otherwise it may cause
power cord damage or even cause a fire or electric shock hazard.
Please grasp the insulated head of power cord to pull out plug from socket. Forced
to pull the power cord may damage the power cord and scale, even may cause a
fire or electric shock hazard.
Don't use the damaged power socket or power cord, don’t attempt to repair them.
Continue to use the damaged power socket or power cord, may lead to the danger
of short circuit, electric shock, or even a fire.
Power supply voltage input please strictly follows the product power requirements!
Beyond its range will cause equipment damage, or even cause a fire or electric
shock hazard.
Don’t touch the power cord with wet hands, don’t wipe scale and power cord with
wet cloth, otherwise it may lead to the risk of electric shock.
Don’t put conductive objects or liquid nearby the scale, to prevent the conductive
objects or liquid into scale body to avoid cause equipment damage, or even cause
a fire or electric shock hazard.
Special Requirement:
In order to make the scale work more stable, please make
sure that the input power with a reliable ground!
1 / 22
CONTENT
1. Summarize ..................................................................................................................... 4
1.1 Structure and appearance ................................................................................... 4
1.2 Display .................................................................................................................. 4
1.2.1 Display Interface................................................................................................ 4
1.2.2 Status Indicators................................................................................................ 5
1.3 Standard keyboard layout .................................................................................... 5
1.4 Keys and function of keyboard ............................................................................ 5
1.5 Function & Features............................................................................................. 6
1.6 Key Parameters.................................................................................................... 6
1.7 How to load label paper roll ................................................................................. 7
2. Sales Operation............................................................................................................. 8
2.1 Preparation and Inspection before usage........................................................... 8
2.2 Power on............................................................................................................... 8
2.3 Selling by weight .................................................................................................. 8
2.4 Selling by package ............................................................................................... 8
2.5 Selling by fixed weight ......................................................................................... 8
2.6 Change price in sale process .............................................................................. 9
2.7 Discount selling .................................................................................................... 9
2.8 View date and time of system.............................................................................. 9
3. Menu and setting operation ...................................................................................... 10
3.1 How to open and exit menu interface................................................................ 10
3.2 Menu and setting operation ............................................................................... 10
3.2.1 Open sub-menu and setting interface methods............................................. 10
3.2.2 Parameters setting .......................................................................................... 10
3.2.3 Change input method ...................................................................................... 10
3.2.4 Special characters input .................................................................................. 10
3.2.5 Exit menu and setting status........................................................................... 11
3.2.6 Menu list and function description .................................................................. 11
4. System Setting ............................................................................................................ 11
4.1 Date & time ......................................................................................................... 11
4.2 Network............................................................................................................... 11
4.2.1 IP Address ....................................................................................................... 11
4.2.2 MAC Address................................................................................................... 11
4.3 Hotkey................................................................................................................. 11
4.4 String ................................................................................................................... 11
4.5 Message ............................................................................................................. 11
4.6 Edit the label format ........................................................................................... 12
4.7 Idel Message ...................................................................................................... 13
5. Parametes Setting....................................................................................................... 13
5.1 System and label parameters setting................................................................ 13
6. PLU Setting .................................................................................................................. 15
6.1 Set PLU............................................................................................................... 15
2 / 22
6.3 Delete PLU ......................................................................................................... 16
6.4 Delete All PLU .................................................................................................... 16
7. Reports Management ................................................................................................. 16
8. Factory Setting ............................................................................................................ 17
8.1 Reset system setting .......................................................................................... 17
8.2 Restore factory setting ....................................................................................... 17
9. System Test ................................................................................................................. 17
9.1 Printer test .......................................................................................................... 17
10. View software version information ........................................................................ 17
11. Error and common troubleshooting ...................................................................... 17
Appendix A. Default label printing format .................................................................. 19
Appendix B. Default system parameters..................................................................... 20
Appendix C. Menu Lists and function description .................................................... 20
3 / 22
1. Summarize
1.1 Structure and appearance
Display
Pan
Level
Keyboard
Foot
Printer cover
Label export
1.2 Display
1.2.1 Display Interface
5 / 22
Enable or disable print pricing labels automatically when weighing in
AUTO PRINT
stable status.
Enter the quantity of selling by package or quantity (goods must have
PACKAGE/×
been set to sell by package or quantity first.)
TARE Remove tare
RE-ZERO Return to zero status
BACKSPACE Delete a character before cursor
OK Operation confirm
Precautions:
1. Label paper should be properly guided by the axis and adjust the width of the guide
limiter.
2. Printed Each five-volume labels or found printing is not clear enough, you should
gently wipe clean the thermal print head heating line (black line) with a cotton swab
dipped a little alcohol (Attention please! Hard material clean the thermal head is
forbidden to avoid damage the thermal print head).
7 / 22
2. Sales Operation
2.1 Preparation and Inspection before usage
1. Ensure the scale placed on a platform which is level, strong enough and stable.
2. Check the power supply voltage conforms to the requirements of the equipment
input power; the power cord plug connection is reliable.
3. Ensure the four feet of scale are contact with platform, scale body no shake.
4. Check the level bubble whether in a central location (as shown in the figure below),
if it not in a central position, you need to adjust the height of feet to make it in the
central position.
5. Ensure there is nothing on the scale body which is not the part of scale.
6. Ensure the label paper was loaded correctly and sufficient quantity.
Correct Wrong
2.2 Power on
1. Ensure there is nothing on scale pan.
2. Open the power switch.
3. Waiting the scale to finish initialization work.
4. Check the "ZERO" indicator at the right side of screen is display or not, and weight
value display is zero or not, otherwise press [RE-ZERO] key to reset scale to zero.
5. Check the "STABLE" indicator at the right side of screen is display or not, if it
displayed, then the scale is in the ready state for sales work.
8 / 22
Note: 1) Only those commodities which sales type was set to “Package” can be sold by
package. 2) Unit displayed at the right side of screen is “pcs”.
9 / 22
3. Menu and Setting operation
3.1 How to open and exit menu
When the scale be in ready status, press [Menu] key to open level 1 menu
interface.
In menu or setting status, press [Menu] key to exit to ready status.
10 / 22
3.2.5 Exit menu and setting status
Press [Menu] key to end menu and setting operation, and exit to ready status.
Press [CLR] key return previous menu.
4. System Setting
4.1 Date & time
1. When the scale be in ready status, press [Menu] key to open the menu interface.
2. Press the [1] numeric key to open sub-menu of “System setting”.
3. Press the [1] numeric key to open “Date & time” setting interface.
4. Enter a new date (format: YYYYMMDD)Press [OK] key.
5. Enter a new time (format: HHMMSS)Press [OK] key to display new date and
time.
6. Press [OK] key to exit.
4.2 Network
4.2.1 IP Address
1. When the scale be in ready status, press [Menu] key to open the menu interface.
2. Press the [2] numeric key to open sub-menu of “Network”.
3. Press the [1] numeric key to open “IP” setting interface.
4. Enter a new IP AddressPress [OK] key.
4.3 Hotkey
1. When the scale be in ready status, press [Menu] key to open the menu interface.
2. Press the [1] numeric key to open sub-menu of “System setting”.
3. Press the [3] numeric key to open “Hot key” setting interface.
4. Enter a PLU No.Press [OK] key.
5. Press a hotkey on keyboard for above Entered PLU No..
6. Repeat step 4 and step 5 operations to others hotkey.
7. Press [CLR] key to exit.
4.4 String
1. When the scale be in ready status, press [Menu] key to open the menu interface.
2. Press the [1] numeric key to open sub-menu of “System setting”.
3. Press the [4] numeric key to open “String” setting interface.
4. Enter an index of string (1-8) Press [OK] key.
5. Enter the content of string (Up to 24 characters) Press [OK] key to finish setting.
4.5 Message
1. When the scale be in ready status, press [Menu] key to open the menu interface.
2. Press the [1] numeric key to open sub-menu of “System setting”.
11 / 22
3. Press the [5] numeric key to open “Message” setting interface.
4. Enter a index of string (1-255)Press [OK] key.
5. Enter the content of message (Up to 96 characters) Press [OK] key to finish
setting.
5. Parameters Setting
5.1 System and label parameters setting
When the scale be in ready status, press [Menu] key to open the menu interface Press
the [2] numeric keys to open “Para setting” interface.
ITEM OPERATION ILLUSTRATION
-Enter the scale No.
Scale No. Integer between 0 and 99999999
-Press [OK] key to save
Paper W Unit of length is 0.1mm, Value: integer
-Enter the printing width
(0.1mm, between 300 and 560, e.g.: 56mm
-Press [OK] key to save
300~560) should be set to 560.
Paper H Unit of length is 0.1mm, Value: integer
-Enter the printing height
(0.1mm, between 250 and 480, e.g.: 37mm
-Press [OK] key to save
250~480) should be set to 370.
-Enter the interval space of Unit of length is 0.1mm, Value: integer
Paper span
labels between 10 and 50, e.g.: 2mm should
(0.1mm,10~50)
-Press [OK] key to save be set to 20.
Printer gray -Enter the printing gray 1~10 class, more great more dark.
(1~10) -Press [OK] key to save Default is 7.
-Set the peel inspection is
Paper Sensor enable or not 1:ON; 2:OFF
-Press [OK] key to save
13 / 22
-Set whether print
PLU name
commodity’s name in middle 1:ON; 2:OFF
center
-Press [OK] key to save
Type of label code as following:
1: POS code + Sales amount(not round
Kopeck)
2: POS code + Weight
3: POS code + Price
4: POS Code
5: POS Code + Weight (5 Digits) +
Sales amount (round Kopeck) (18
digits)
6: POS code + Sales amount(round
Kopeck)
7: POS code + Weight (5 digits) + Sales
-Select the composition of amount (not round Kopeck) (18 digits)
Barcode barcode data types 8: POS code + Sales amount (round
-Press [OK] key to save Kopeck+ Weight(5 digits) (18 digits)
9: POS code + Sales amount(not round
Kopeck) + Weight (5 digits)(18 digits)
10: 1 + Weight + POS Code
11: POS code + Price+ Weight (5
Digits) (18 digits)
12: POS Code + Weight (5 digits) +
Price (18 digits)
Note:
Not round Kopeck = last digit is
Kopeck. e.g.: 2.22 USD
Round Kopeck = last digits is 10
Kopeck. e.g.: 2.2 USD (rounding)
-Enter the length of PLU
PLU code LEN code 1-8 figures
-Press [OK] key to save
-Set the PLU code style
PLU code style 1:Prefix+code; 2:Only code
--Press [OK] key to save
-Set the prefix of PLU code
Prefix Integer between 0 to 99
-Press [OK] key to save
- Set the number it represent Represents the number of package or
QTY in barcode quantity in barcode fixed weight for goods
--Press [OK] key to save 1: 1PCS=1000(×1000); 2: 1PCS=1(×1)
1: Decimal 3 round;
-Set decimal places rounding 2: Decimal 3 remove;
Round
-Press [OK] key to save 3: Decimal 2 round;
4: Decimal 2 remove;
-Set the unit of weight 1: Kg;
Weight unit
-Press [OK] key to save 2: g
-Set the weight of unit price
Price unit 1: Per Kg; 2: Per 100g; 3: Per 500g
-Press [OK] key to save
Price -Set whether can change
1: Yes; 2: No
changeable? price in sale process
14 / 22
-Press [OK] key to save
-Set whether can discount in
Discount
sale process 1: Yes; 2: No
enable?
-Press [OK] key to save
1: Don’t Print date;
-Set whether print date on
2: Print packing date;
Date type label
3: Print EXP date;
-Press [OK] key to save
4: Print both date (packing and EXP)
-Enter the default shelf life
DEF. EXP
(day) Integer between 0 and 99999
date(day)
-Press [OK] key to save
-Set whether enable
STAT. report statistics report function 1:ON; 2:OFF
-Press [OK] key to save
-Enter the index of label Can store up to five formats (0-4)
Label format format Note: After setting this item, the section
index -Press [OK] key to save and "4.6" edit the label format is set for this
exit setting index.
6. PLU Setting
6.1 Set PLU
When the scale be in ready status, press [Menu] key to open the menu interface Press
the [3] numeric key to open sub-menu of “PLU setting” Press the [1] numeric key open
“Set PLU” interface, then set the parameters as following one by one:
ITEM OPERATION ILLUSTRATION
If the PLU No. is existed then into
-Enter PLU No.
PLU No. modify status, otherwise, into add
-Press [OK] key
status.
-Enter PLU Code.
Barcode Commodity code (Part of barcode)
-Press [OK] key
-Enter the name of commodity.
Name
-Press [OK] key
-Enter the price of commodity.
Price
-Press [OK] key
-Set sales type
Type 1: Weight; 2: Package; 3: Fixed weight
-Press [OK] key
Fixed weight -Enter the fixed weight Only valid and appear for goods which
(g) -Press [OK] key selling by fixed weight
Tare weight -Enter the tare weight Only valid and appear for goods which
(g) -Press [OK] key selling by weight
1:Don’t print date; 2:Print packing date;
-Set whether print date on label
Date type 3:Print EXP date; 4:Print both
-Press [OK] key
date(packing and EXP)
Def. exp -Enter the shelf life (day)
1 to 5 figures
date (day) -Press [OK] key
Price -Set whether can change price
1: System default; 2: Yes; 3: No
changeable? -Press [OK] key
Discount -Set discount mode 1:No discount; 2:Special price;
mode -Press [OK] key 3:Percent(%); 4:Coupon
15 / 22
-Enter special price Only valid and appear for discount
Special price
-Press [OK] key mode set to special price
-Enter discount percent Only valid and appear for discount
Percent (%)
-Press [OK] key mode set to Percent
-Enter the amount of coupons Only valid and appear for discount
Coupon
-Press [OK] key mode set to coupon.
This message is set in the menu item
Message -Enter message of commodity
"1.5. Message (1 to 255)", can be set
(1~255) -Press [OK] key to finish setting
up 255PCS.
Note:
1. PLU Code: It is a commodity code, is a part of label barcode data representing a
commodity, this code requirements consistent with the cash register system
commodity codes for this commodity.
2. PLU No.: It is a short code of commodity. Usually use it to set hotkey of commodity.
Salesperson usually press hotkey or enters this No. then press [PLU] key to bring
up to sell commodity.
7. Reports Management
In ready status, press [Menu] key to open the menu interface Press the [4] numeric key
to open “Reports” interface.
ITEM OPERATION ILLUSTRATION
Press [OK] key to view the View the first label printing time after
Date & Time
next item the last time delete report data.
Daily Total Press [OK] key to view the View the first label printing time after
Amount next item the last time delete report data.
Daily Label Press [OK] key to view the View the first label printing time after
Count next item the last time delete report data.
Clear-out - Select “Yes” or “No” Delete all report data and can’t regain,
Report - Press [OK] key to execute please do it be careful!
Note: You need to enable the “Static report” function in “PARA setting” in menu, then the
scale will automatically records and add up related data.
16 / 22
8. Factory Setting
8.1 Reset system setting
1. In ready status, press [Menu] key to open the menu interface.
2. Press the [5] numeric key to open sub-menu of “Factory setting”.
3. Press the [1] numeric keyEnter password (“12345678”) Press [OK] key to
execute “Reset system setting“ function.
4. The scale will re-boot.
Note: This operation will restore the scale settings for all parameters to the initial state of
the factory, but it does not delete the PLU information, reports and other user data.
9. System Test
9.1 Printer test
1. In ready status, press [Menu] key to open the menu interface.
2. Press the [6] numeric key to open sub-menu of “System test”.
3. Press the [1] numeric key or [OK] key to execute “Printer test” function.
18 / 22
Appendix A. Default label printing format
Space
Print Letter Printing
Label editing item Width Height Title at X-axis Y-axis
or not font direction
edge
1 Internal code 0
2 Product Name 1 3 0 10 74
3 PLU Code 0 10 106
4 Price 1 1 0 52 106
5 Weight 1 1 0 105 138
6 Amount after
1 1 0 355 106
discount
7 Label code 1 0 3 50 10 0
8 Date 1 0 0 345 138
9 Effective days 0
10 Rectangle 0
11 Time 0
12 Amount before
0
discount
13 Expiry date 1 0 0 265 154
14 Discount rate 0
15 Title 1 1 1 0 17 10 106
16 Title 2 1 1 0 21 110 106
17 Title 3 1 1 0 8 10 138
18 Title 4 1 3 0 22 170 138
19 Title 5 1 1 0 13 224 106
20 Title 6 1 0 0 5 224 138
21 Title 7 1 0 0 23 224 154
22 Title 8 0
23 Title 9 0
24 Letter string 1 1 3 0 60 190
25 Letter string 2 0
26 Letter string 3 0
27 Letter string 4 0
28 Letter string 5 0
29 Letter string 6 0
30 Letter string 7 0
31 Letter string 8 0
32 Explanation text 0
Note: No.10 Rectangle Function only in Software Version 1.08 or above.
19 / 22
Appendix B. Default system parameters
Setting parameters Value Discription
Sacle No. 1
Label width 448 448 x 0.125mm = 56mm
Label height 296 296 x 0.125mm = 37mm
Label internval space 20
Printing greyness 7 More larger more deep
Label paper peeling check 1 Enable
PLUS printed in the centre 1 Yes
Code + Sales amount
Label code type 0
(Not rounding Kopeck)
POS code length 7
POS code type 0 Prefix+Internal code
POS code prefix 29
Sales amount roudning type 0 Rounding at the 3rd. digits
Weight unit 0 kg
Price unit 0 /kg
Allow temporary price change 0 No
Allow Discounts 0 No
Lock the PLU function 0 Disable
Automatic printing function 0 Disable
Default printing date-time 3 Packaging date and effective date
Report Statistics 0 Disable
2.PARA Setting
2.1.Scale No. Scale No. (Integer between 0 and 99999999)
20 / 22
2.2.Paper W
Width of label paper
(0.1mm,300~560)
2.3.Paper H
Height of label paper
(0.1mm,250~480)
2.4.Paper span
Interval space between labels
(0.1mm,10~50)
2.5.Printing gray (1~10) Printing
2.6.Paper sensor Set the peel inspection is enable or not
2.7.PLU name
Set whether print commodity’s name in middle
center(1~2)
2.8.Barcode Select the composition of barcode data types
2.9.PLU code LEN(1~8) Length of PLU code
2.10.PLU code
PLU code style (1:Prefix+code; 2:Only code)
style(1~2)
Prefix of PLU code (Used to distinguish different types
2.11.Prefix
commodity)
Represents the number of package or fixed weight for
2.12.QTY in barcode
commodity in barcode.
(1~2)
1: 1PCS=1000(×1000); 2: 1PCS=1(×1)
2.13.Round Decimal places rounding of amount
2.14.Weight unit Such as “Kg”, “g” and so on
2.15.Price unit Weight of unit price (1: Per Kg; 2: Per 100g; 3: Per 500g)
2.16.Price changeable?
Whether can change price in sales process
(1~2)
2.17.Discount Enable? Whether can discount in sales process
Whether print date information on label and the type of date
2.18.Date type
for printing
2.19.DEF.EXP
Default shelf life of commodity (day)
Date(day)
2.20.Static report Whether enable statistics report function
2.21.Label format index Set the index of label format for choice
3.PLU Setting
3.1.Set PLU Set commodity information
3.1.1.PLU No. PLU number of commodity
3.1.2.Barcode Commodity code (Part of barcode)
3.1.3.Name Name of commodity
3.1.4.Price Price of commodity
3.1.5.Sales type 1: Weight; 2: Package; 3: Fixed weight
3.1.6.Fixed weight(g) Weight of commodity selling by fixed weight
3.1.7.Tare weight (g) Tare weight of commodity, e.g.: weight of package
Whether print date information on label and the type of date
3.1.8.Date type
for printing
3.1.9.DEF.EXP
Shelf life of commodity (days)
date(day)
3.1.10.Price
Whether can change price in sales process
changeable?
3.1.11.Discount mode Discount mode of commodity
3.1.12.Special price Special price of commodity
21 / 22
3.1.13.Percent (%) Discount percent of commodity
3.1.14.Coupon Coupon of commodity
3.1.15.Message(1~255) Index of Message for commodity
3.2.DEL PLU Delete a PLU according to PLU code (Barcode)
3.3.DEL ALL PLU Delete all PLUs
4.Reports
View the first label printing time after the last time delete
4.1.Date & time
report data.
View the first label printing time after the last time delete
4.2.Daily total amount
report data.
View the first label printing time after the last time delete
4.3.Daily label count
report data.
Delete all report data and can’t regain, please do it be
4.4.Clear-out report?
careful!
5.Factory Setting
Restore the scale settings for all parameters to the initial
5.1.Reset system state of the factory, but it does not delete the PLU
setting information, reports and other user data.
Confirm password: 12345678
Restore the scale settings for all parameters to the initial
state of the factory, and it will delete the PLU information,
5.2.Restore factory
reports and all others user data and can’t regain, please
setting
do it be careful!
Confirm password: 12345678
6.System Test
6.1.Printer test Execute printing function and print a test label
22 / 22