CEEDUCER PRO User Manual v3.18.02
CEEDUCER PRO User Manual v3.18.02
User Manual
Version 3.18.02
www.ceehydrosystems.com
CEEDUCER PRO™ User Manual V3.18.02
Copyright
This manual is copyright(C) 1992-2011 Bruttour International Pty. Ltd. All rights reserved.
This manual, or parts thereof, may not be reproduced or transmitted in any form or by any means,
electronic, mechanical, photocopying, recording or otherwise, without prior written permission of Bruttour
International Pty Ltd except on "an in-house" basis by Users of the CEE range of Hydrographic surveying
equipment and software, for the express purpose of their own use.
The following known Trade Marks or Trade Names may appear in this manual and are used in an
editorial context in the text with implied benefit to the Owners of those Trade Marks or Trade Names with
no intention of any infringement of those Trade Marks or Trade Names: HYPACK, LEMO, Microsoft,
HyperTerminal, Windows, and any variants, severally thereof.
Notice of Liability
The information in this book is distributed on an "as is basis" without Warranty. Every effort has been
made to ensure accuracy in the accuracy of the information contained in this book but neither Bruttour
International Pty Ltd, nor its Employees and Associates shall have any liability to any person or entity with
respect to liability, loss, consequential loss, or damage caused directly, or indirectly, by the use of the
information in this book.
CEEDUCER PRO™, CEETIDE™, CEESTAR™ and CEEBASE™ are registered TRADE MARKs of
Bruttour International Pty Ltd.
The equipment has been tested and found to comply with the limits of a Class A computing device
pursuant to part 15 of the FCC rules. The equipment is also believed to comply with the requirements of
a Class B computing device but has not been tested thereto.
This equipment was tested for compliance under conditions that included the use of shielded cables and
connectors between it and peripherals. It is important to use shielded cables to reduce the possibility of
causing, or suffering from, the effects of radio interference.
For Users in the USA, the booklet published by the FCC and entitled "How to identify and resolve Radio-
TV interference Problems" may be of help. Copies can be obtained from:
2
Contents
Quick Start ................................................................................................................................................... 5
How to use the manual ................................................................................................................................ 7
Equipment Care ........................................................................................................................................... 7
Introduction .................................................................................................................................................. 8
System Description .................................................................................................................................. 8
System options ........................................................................................................................................ 8
The CEEDUCER PRO™ unit ................................................................................................................ 10
System Functions .................................................................................................................................. 12
Getting Started........................................................................................................................................... 18
System Installation................................................................................................................................. 18
Configuration Instructions ...................................................................................................................... 21
Survey Operation ................................................................................................................................... 23
Averaging a reference position .............................................................................................................. 23
Post survey Data processing ................................................................................................................. 24
Reference .................................................................................................................................................. 25
Using the real time survey screen ......................................................................................................... 25
Using the Menu System ........................................................................................................................ 27
Using Parameter Edit pages.................................................................................................................. 28
System Configuration settings ............................................................................................................... 28
Echosounder input, and sound velocity correction ................................................................................ 37
Display ................................................................................................................................................... 50
Operational Considerations ................................................................................................................... 61
Using real time data ............................................................................................................................... 63
CEEDUCER PRO™ Real time Input data ............................................................................................. 64
CEEDUCER PRO™ Real time Output Data combinations ................................................................... 67
CEEDUCER PRO™ Log Download Data ............................................................................................. 72
Appendix A – Hardware details ................................................................................................................. 73
Physical ................................................................................................................................................. 73
Electrical ................................................................................................................................................ 73
Connections ........................................................................................................................................... 74
Model options ........................................................................................................................................ 75
GPS receiver details .............................................................................................................................. 75
Marine Beacon receiver details ............................................................................................................. 76
Appendix B – Cable Details ....................................................................................................................... 77
Data/Fix Cable DCE .............................................................................................................................. 77
3
CEEDUCER PRO™ User Manual V3.18.02
4
Quick Start
The following information relates to running the CEEDUCER PRO™ Hydrographic Survey System using
the internal GPS receiver and standard transducer (single frequency or dual frequency). Please refer to
the relevant section/s of this manual for interfacing the CEEDUCER PRO™ with an external GPS
source, external echosounder source or correcting data for heave and/or tide in real time.
(The CLEAR button is an escape key and will take you back to the previous menu option without saving
the settings made)
− Connect the GPS antenna to the control unit using the TNC-TNC antenna cable (see figure 1 below
for location of this connector on the CEEDUCER PRO™). The antenna should be mounted high
enough to be clear of obstructions such as the cabin of the boat. Obstructions can cause
interference of the GPS signal or block the incoming GPS signal completely. Where possible mount
the GPS antenna directly above the transducer to eliminate offsets between logged position and
depth data.
− Mount the transducer in the water in a position that will allow the water to pass cleanly across the
face of the transducer when under way. Mounting the transducer in a way that will expose it to
aeration will cause zero readings some or all of the time during the survey. The best temporary
mounting position is over one side of the vessel approximately halfway along the boat with the
transducer face at least 50cm below the water surface. Connect the LEMO plug/s from the
transducer into the CEEDUCER PRO™ (see figure 1 below for location of this connector on the
CEEDUCER PRO™ – NOTE: The CEEDUCER PRO™ does not have a HF or LF specific
connection port. Both 2B LEMO sockets will accept either high frequency and low frequency data,
which socket you use does not alter the operation of the system)
− With the GPS antenna and transducer connected turn the CEEDUCER PRO™ on by pressing the
ON/OFF button for 1 second. The LED s on the left side will light up initially then flash as data
passes through the relevant connectors. The screen will display the CEEDUCER PRO™ logo during
start up then show the main survey screen layout. When main survey screen is shown the
information will be updated with GPS position and depth as measured by the echosounder.
− Ensure both the date and time is correct for your log records. Data is time stamped using this
information. From main front screen press MENU – F2 (Setup) – F1 (System) – F1 (Time & Date) –
F2 (Set UTC Offset). Select the local time offset and press ENTER to save.
− The logged GPS data is based on WGS84 with Default UTM (UTM specification is selected by the
CEEDUCER PRO™ automatically). The position display format on the screen can be selected
through screen setting menu – MENU – F2 (Setup) – F4 (Screen) – F1 (Position Format). Select the
preferred option and press ENTER to save.
− The internal GPS should be configured to use the RTCM correction source required – Marine
Beacon, SBAS, OmniSTAR, RTCM 2.0 (external source), RTCM 3.0 (external source) or no
differential correction. Go to MENU- F4 (Advanced) – F2 (Diff) – F1 (Diff source).
− NOTE: The RTCM (Diff) options depend on the GPS receiver installed. See the relevant chapter in
the manual outlining the options available and how to configure each option. Select the preferred
option and press ENTER to save.
− Select the transducer option to be used – HF, LF or both HF & LF. Keystrokes from the main front
screen press MENU – F2 (Setup) – F3 (Echo Sounder) – F1 (Connected E/S’s) – F2 (Internal
Select’n). Select the preferred option and press ENTER to save.
5
CEEDUCER PRO™ User Manual V3.18.02
− Select velocity of sound in water mode. Sea, Fresh and Brackish are automatic functions designed
for correcting sound velocity for each option based on water temperature as measured by the
transducer at the face. Keystrokes from the main front screen press MENU – F2 (Setup) – F3 (Echo
Sounder) – F2 (Velocity Select’n) – F1 (Velocity Mode). Select the preferred option and press
ENTER to save.
− Enter the required draft (distance from water surface to face of transducer) for each frequency being
used (HF and/or LF). Keystrokes from the main front screen press MENU – F2 (Setup) – F3 (Echo
Sounder) – F3 (E/S Draft) – F1 (HF E/S Draft) and/or F2 (LF E/S Draft). Select the preferred option
and press ENTER to save.
− Conduct a bar check (lower a plate under the transducer face at known depths) to ensure the setup
of the transducer is correct. If the depth displayed does not match the known depth re-check the
draft and sound velocity options entered.
− Once the system is checked and depths shown agree with the bar, check Create a Log File to store
the data to. Keystrokes from the main front screen press MENU – F1 (Logging) – F1 (Files) – F1
(Create New File), use the default file name or create your own name of up to six alphanumeric
characters. Select the preferred option and press ENTER to save.
− Navigate back to the main survey window by pressing the CLEAR button. You should now see the
depth profile (depth vs. time not depth vs. distance) moving from right to left, the current date and
time, GPS position in your preferred format, the correction quality of your GPS position (No Diff, 2 or
4), the depth in real time measure by the HF and/or LF transducers, the current log file name, logging
status, memory capacity used and mode of operation (should be set to Normal – see Mode of
Operation section in the manual for further details).
With all the relevant information stored in the CEEDUCER PRO™ you are ready to survey. Press F1 to
start logging, ensure the screen has updated to show the system is logging and begin collecting data.
If there is a problem with a connection to the GPS or transducer/s the Error LED will light up (red) and a
message will appear on screen informing you of the problem. The CEEDUCER PRO™ will not start to
log data with an error message displayed or no log file name entered. The CEEDUCER PRO™ will
pause logging if the GPS and/or transducer data is lost due to poor reception or loss of cable connection.
Logging will automatically resume once GPS or transducer error has been corrected.
Once a log file has been started (data has been recorded to it) the critical CEEDUCER PRO™ settings
that contribute to the accuracy of the data cannot be changed (e.g. draft of transducer). The file must be
closed to allow these critical settings to be changed. Non critical settings such depth profile range or real
time data output settings can be altered during data collection with no affect on the logged data.
6
How to use the manual
This manual is broken up into four main sections:
− Introduction – gives a basic explanation of the CEEDUCER PRO™ system, what it is capable of, and
what it should be used for.
− Getting Started – gives an overview of the many aspects of setting up and using a CEEDUCER
PRO™ system.
− Reference – shows the fine details of the system structure, all the configuration options, output
formats, and input formats.
− Appendices – these contain other reference information related to the CEEDUCER PRO™ system.
Physical objects such as buttons, LEDs, or connectors are listed in bold. i.e., “F1”, “DATA OUT”
Points of note are indicated by a prefix in bold. i.e. NOTE: you should consider this
Warnings are indicated by being coloured red. i.e. WARNING: DO NOT DO THIS!!! A warning
message will inform you of actions that may damage or destroy logged data or hardware.
Equipment Care
To ensure maximum service life of the equipment please read the manual thoroughly prior to use to
ensure correct operation.
WARNING: Do not connect a power source that exceeds the recommended power input for the
CEEDUCER PRO™. This is 13.7V DC for a lead acid battery system and 24V DC for a Nickel Metal
Hydride battery system. See the About section of this manual to determine what battery type you have.
WARNING: Do not run transducer/s in air for extended periods. Transducers are designed to be
operated through solid or liquid materials only (wet wells, urethane housings etc.). Long periods of
operating in air can damage the transducer reducing accuracy and/or service life. Operating the
transducer through air for short periods for the purpose of confirming the transducer is operating is
acceptable and should be limited to 30 seconds.
WARNING: Ensure all plug caps are secure and in place when in the field. IP rating is based on all
plugs being sealed with the supplied cap.
NOTE: Do not store or transport the CEEDUCER PRO™ control unit and associated cables with wet
transducer/s.
7
CEEDUCER PRO™ User Manual V3.18.02
Introduction
System Description
The CEEDUCER PRO™ is an integrated and highly portable hydrographic survey system based on
single beam technology for the purposes of bathymetric surveying.
The CEEDUCER PRO™ brings together a GPS receiver, echo sounder(s) with water temperature
velocity correction, and optional real time correction data such as Tide, Heave, and GPS Differential
inputs. It takes this live data, along with static survey setup data, such as echo sounder drafts, GPS
antenna height, water salinity, and transforms it into meaningful information relating to water depths at a
continuous series of locations, and allows this concentration of data to be logged internally and/or
transmitted to a PC running real time Hydrographic surveying software such as HYPACK™.
The system is designed to run on internal power with basic peripherals connected. If required an external
power supply of 12 volts DC (lead acid system) or 12-24 volts DC (for NiMH system) can be connected
to run the system for an extended period. It is a very compact system, allowing the smallest vessels to be
used for hydrographic surveying work.
System options
GPS options
The CEEDUCER PRO™ comes with an internal GPS receiver. This can optionally be a Hemisphere
Eclipse receiver or a Hemisphere Crescent receiver. Previously the CEEDUCER PRO™ was also
supplied with A12, G12, and DG14 receivers from Thales navigation, however these options are no
longer offered as of 2009.
The Hemisphere Crescent is a single band (L1 only) receiver that may be run with differential data
received from an internal Marine Beacon receiver, with external input of RTCM V2.0 format local
differential correction data, or set to receive SBAS data (WAAS/EGNOS/MSAT).
The Hemisphere Eclipse is a dual band (L1, L2) GPS receiver that can optionally be configured to run
with RTK correction data (see RTCM Data formats for examples of suitable RTCM messages) for
exceptionally high precision position calculations. It can also run with corrections from a valid OmniSTAR
TM
HP/XP subscription, RTCM V2.0 format local DIFF corrections or may optionally be configured to
receive SBAS-WAAS/EGNOS/MSAT corrections.
If required the differential function can be disabled on both GPS receiver options to run as a standalone
receiver. Additionally, the CEEDUCER PRO™ has provision to ignore its internal GPS and run with any
external GPS connected, provided the external GPS can provide NMEA 0183 compliant GGA, VTG and
ZDA messages. In this case, the differential correction applied to the GPS position calculations is
dependent on the configuration of the particular external GPS unit connected.
8
Transducers
The CEEDUCER PRO™ system includes proprietary CEE HydroSystems™ smart transducer units
where the actual echo sounder device is built into the transducer housing and communicates serial data
back to the main CEEDUCER PRO™ control unit.
Keeping the entire echo sounder unit in one piece makes transducer mismatch issues impossible and
also minimises the amount of noise that can get coupled into the delicate echo sounder receiver circuitry.
CEE HydroSystems™ can provide 200kHz transducer options with an 8° or 2.75° beam angle. CEE
HydroSystems™ also offers a 30kHz/19 degree beam angle transducer that can be run alone or
simultaneously with a 200kHz transducer.
A default CEEDUCER PRO™ system would include a single 200 kHz echo sounder with a beam angle
of 8°. The addition of a 30 kHz sounder to the system can be used for providing solid bottom sensing to
give an indication of soft mud or weed depth.
CEE HydroSystems™ offers a urethane fairing kit to house both the 30 kHz/19° and 200kHz/8° units in
the same streamlined housing. The individual transducers can be removed for independent use if
required
Battery technology
The CEEDUCER PRO™ uses a Nickel Metal Hydride (NiMH) battery for internal power. The NiMH
battery capability allows for much longer run time for the stand alone system (typically 8-10 hours
dependant on GPS and transducer configuration) and a much more reliable/robust system from the point
of view of battery maintenance and input power requirements.
Prior to NiMH batteries the CEEDUCER PRO™ was supplied with a Sealed Lead Acid (SLA) internal
battery. This manual outlines proper use of both battery technologies on Power Input. Many lead-acid
battery CEEDUCER PRO™ units exist in the field, however only NiMH units are being manufactured as
of July 2009. CEEDUCER PRO™ units with NiMH technology are identified by viewing the About screen
as described in About System
WARNING: Do not charge the battery in direct sunlight. Must not be charged when temperature is
lower than 0°C or above 45°C.
Bluetooth
Bluetooth serial communication may be installed on a CEEDUCER PRO™ – this option allows various
options for wireless communication between a CEEDUCER PRO™ unit and a survey or download PC.
Survey data can be sent via Bluetooth in real time or for data download. RTCM data can also be
received by the CEEDUCER PRO™ via Bluetooth. It is possible to send survey data out while receiving
RTCM in via the same Bluetooth connection simultaneously.
“Bluetooth Available” will be displayed at the bottom of the About screen informing the user if the
Bluetooth option has been installed. If the is no message then Bluetooth connection is not available.
9
CEEDUCER PRO™ User Manual V3.18.02
Charged Indicates internal battery voltage is high, or that the unit is running successfully off
external power. If flashing when the unit is off, it indicates the NiMH battery is being
charged from an external power supply.
Low Batt Indicates internal battery voltage is low.
A E/S Indicates Echo sounder A data received.
B E/S Indicates Echo sounder B data received.
GPS Indicates GPS data received.
Diff Data Indicates GPS Correction data received.
Data Out Indicates transmission of data from CEEDUCER PRO™ unit.
Error Indicates an ERROR state when solid red. If flashing, indicates NiMH battery is
discharging in storage mode.
10
CEEDUCER PRO™ Display
The CEEDUCER PRO™ is equipped with a 320 x 240 graphic LCD module, and this display can be
used to see more of what is happening during a survey than the LEDs can show as well as to examine or
edit parameter settings in the menu system. The display includes a real time profile of depth data versus
time, position and logging status. In the event of an error occurring the screen will display what
component/components has caused the problem to occur to help fix the problem. The screen is also
used to examine or edit parameter settings in the menu system.
The Left hand side of the CEEDUCER PRO™ holds a series of connectors, from left to right: GPS
antenna, Data Output Port, Ext GPS/RTCM input port, Heave/tide input port, External power port,
Transducer port 1, Transducer port 2.
11
CEEDUCER PRO™ User Manual V3.18.02
The right hand side of the CEEDUCER PRO™ holds the Ethernet connector, and optionally the External
Bluetooth antenna connector (standard Bluetooth antenna in internal).
System Functions
The CEEDUCER PRO™ brings together a set of devices and functionalities. The relation of these different
devices and functionalities is shown in
Figure 4. These devices, functionalities and their capabilities are explained in more detail below.
Echosounder A
PC
Echosounder B Log data
External
Echosounder
Real Time data
Tide correction RS232
Ethernet
Heave correction
12
Operational Mode
The CEEDUCER PRO™ has three modes of operation; these are selected as appropriate for different
purposes. The correct mode must be set in order for the unit to log the data required.
Normal mode – This is the standard Bathymetric Surveying mode. Apart from a few isolated functions
(described below) the default setting of the CEEDUCER PRO™ is in normal mode. There are multiple
sub choices available within the normal mode.
Averaging mode – This is used to create a known reference point if there is no reference point
available. When the CEEDUCER PRO™ GPS antenna is in a static location the system will use
incoming GPS data and store the resultant average position to memory in a log file.
Storage Mode – This is a mode especially for running down the internal NiMH battery to around 30%,
and then automatically turning off the unit. 30% is the ideal charge capacity to leave NiMH batteries at
when they will not be used for a long time. If the NiMH battery is below 30% when storage mode is
enabled the CEEDUCER PRO™ will immediately turn off.
System
CEEDUCER PRO™ system settings generally relate to the internal functioning of and information about
the CEEDUCER PRO™ unit. One important aspect of the CEEDUCER PRO™ system is the real time
system clock which is used to timestamp received data in Log files.
Depending on the accuracy of the survey required different types of GPS may be needed. The accuracy
of a GPS is usually given in terms of the type of corrections used. Internal GPS options in the
CEEDUCER PRO™ allow the range of GPS correction types described below to be used.
External RTCM 3.0 – RTK: A system involving a local base station with a known location sending
real time data in RTCM 3.0 format to a roving receiver doing the survey. This correction message
allows the rover to record very accurate position information in real time. A CEEBASE™ system can
be used to generate the RTCM 3.0 correction messages required for RTK positioning. Contact
Bruttour International Pty Ltd if you require further information regarding base station solutions.
NOTE: Only available on Eclipse GPS model with RTK Rover activation
External RTCM v2 – DGPS: A system involving a local base station with a known location sending
real time data in RTCM v2 format to a roving receiver doing the survey. This correction message
allows the rover to record sub metre position information in real time. A CEEBASE™ system can be
used to generate the RTCM 2.3 correction messages required for DGPS positioning. Contact CEE
HydroSystems™ if you require further information regarding base station solutions.
OmniSTAR HP/XP: (also referred to as L-band) A satellite based correction service that requires a
paid subscription. OmniSTAR sends high accuracy GPS satellite correction data collected from
base stations around the world, to the roving receiver doing the survey. OmniSTAR uses
telecommunication satellites to broadcast the correction signals. Decimetre (10cm) accurate.
Contact CEE HydroSystems™ if you would like further information on purchases, a new or renewed
subscription.
13
CEEDUCER PRO™ User Manual V3.18.02
Marine Beacon: This is a local Diff service usually setup by a Governmental organisation for public
use. Marine beacon services exist in many parts of the world, around coastlines, where a local base
station provides differential corrections for the GPS satellites it receives. These services are
supplied within a standard frequency range, and can be tuned into with a Marine Beacon Receiver.
Marine Beacon can provide corrections to around 1m horizontal accuracy.
WARNING: as a locally configured and run service from an external party, there are no
guarantees on the accuracy, or service availability, or even the reference datum a given Marine
beacon service is providing corrections to (many do not correct to WGS-84) It is suggested that any
Marine Beacon system be researched before use, and its usefulness determined prior to performing
a survey.
Autonomous: In this case, the GPS runs only with received GPS satellite signals. Accuracy is
usually within 5 metres, but may be as poor as 10m.
The CEEDUCER PRO™ does not apply any of these corrections to GPS data itself. It just supplies
corrections (from external or internal source) to the internal GPS receiver if required, or configures the
GPS receiver to use one of the satellite based services if required, and then logs/displays and/or outputs
the position data supplied from the internal or an external GPS receiver.
It is possible to use CEEDUCER PRO™ to receive data from an external echosounder device. When
connected to an external device it is assumed that the external device does all velocity scaling and draft
calculations. Corrections for velocity scaling and draft are not done by the CEEDUCER PRO™ for
external echosounder input. See Velocity Mode for information on how to set the sound velocity option in
the CEEDUCER PRO™. See Echosounder Data for external echosounder formats accepted by the
CEEDUCER Pro™.
A heave sensor is a motion sensing device that can be used to track movement in real time. The real
time data output from a heave sensor (or Motion Reference Unit - MRU) can be added or subtracted
from the transducer depths to null out the action of the waves.
14
When Heave is being received by the CEEDUCER PRO™ control unit, all depth values received are
automatically adjusted by the most recent heave amount at the time of their reception. These adjusted
values are displayed on the CEEDUCER PRO™ screen and logged so they may be investigated in post
survey processing. See Heave Input for more information on interfacing a MRU with the CEEDUCER
PRO™.
Real time tide data supplied to the CEEDUCER PRO™ can be used for this function. The alternative is
for Tide data to be logged separately and integrated with the survey data in post processing. This data
can be supplied by a tide gauge, such as the CEETIDE™ Acoustic Tide Gauge. The format accepted by
the CEEDUCER PRO™ for real time tide correction is CEETIDE™ Output Format 2 (see Appendix G for
details on data format).
When tide data is being received by the CEEDUCER PRO™ control unit, all depth values received are
automatically adjusted by the most recent Tide amount at the time of their reception. These adjusted
values are displayed, output in real time and logged. In the case of logging, the tide value associated
with an epoch of logged depths is also logged so they may be investigated in post survey processing.
Display
Survey status and real time data is provided through the CEEDUCER PRO™ control unit’s front panel
display for the purpose of checking correct operation during a survey. Some aspects of this data can be
configured to user preferences. None of these configuration options affect what is output in real time or
what is logged.
It is possible to shift geodetic data with a spheroidal shift function and to perform custom Transverse
Mercator projections for the sake of getting position data shown on the CEEDUCER PRO™ displayed to
match a local grid. This shift process does not alter the logged position data. Further information on
performing a geodetic shift for display purposes is in Geodetic Setup. For performing a geodetic shift on
logged data please refer to the CEEDATA™ manual.
15
CEEDUCER PRO™ User Manual V3.18.02
Once a file has been closed that the file will no longer be logged into and a new file will have to be
opened in order to log more epoch records. Once a file has been started the critical settings cannot be
changed (e.g. draft setting, GPS settings etc.). The file must be closed to allow changes to be made to
the critical settings
There are no file operations implemented. Once a file is created it exists in memory with the name it was
created with until CLEAR LOG is performed. This removes the temptation to manage log files inside the
CEEDUCER PRO™ unit in the field where the wrong data could be erased. Downloading the file does
not remove it from the memory of the CEEDUCER PRO™.
The next event number to be used is displayed in the rolling data display during normal operation while
the CEEDUCER PRO™ is logging. See Using the real time survey screen.
It is also possible to place NEWLINE messages inside an epoch record. These are the special log file
messages for the purpose of breaking up a long stream of epoch records into lines and are only used on
conversion of downloaded log file data to HYPACK™ format. These NEWLINE messages have no
identifiers, and require no system configuration. A NEWLINE message is recorded into the current epoch
record when the “FIX” button is released after being held down for greater than 5 seconds.
This NiMH battery system is designed to work with a DC input of 12V to 24V.
16
This system will work with a DC input between 12 to 14.2V, or a 12V Lead acid battery charger.
NOTE: CEE HydroSystems™ can perform a battery system upgrade from Lead Acid to NiMH for longer
run time and durability. Please contact CEE HydroSystems™ for further information.
WARNING: Running greater than 14.2V into a lead-acid battery equipped CEEDUCER PRO™ will
overcharge and destroy the battery.
WARNING: Lead Acid batteries should not be stored for long periods without a charge applied. To
maintain the internal lead acid battery leave the Lawtronics battery charger supplied with the original kit
connected when the unit is stored between jobs. The Lawtronics battery charger supplied with the kit at
time of purchase will not overcharge the battery and will ensure maximum lifespan.
17
CEEDUCER PRO™ User Manual V3.18.02
Getting Started
System Installation
Control Unit Location
Position the CEEDUCER PRO™ unit in a comfortably accessible position for operation by the user
during the process of the survey.
There should be room on the left and right hand side for all necessary connections to be made. The
CEEDUCER PRO™ should be secure enough in its placement that it cannot be vibrated or jolted from its
location due to motion of the survey vessel.
In addition to all this the unit should be placed in a location where it is not exposed to extreme heat.
Transducer Location
The transducer is best installed as close as possible to the centre of the survey vessel to minimise the
amount of movement due to vessel speed, personnel moving around the vessel and wave action. The
transducer face should have minimal water turbulence or aeration from either the propeller or other
sources such as cooling outlet pipes.
It is recommended to locate the transducer so that the draft of the face is a minimum of 50cm below the
surface. If it is possible to achieve clean water around the transducer at a shallower draft under survey
speed, then the echo sounder can operate at a shallower draft. Do ensure the transducer surface is not
exposed to aeration or too much turbulence.
After installation and adjustment it is necessary to record the draft/s of the transducer unit/s.
NOTE: Any other transducer operating in the same frequency range as a CEEDUCER PRO™
transducer will cause the transducer to lose bottom lock. Please check that any fish finder or navigational
echo sounders are not causing interference with the CEEDUCER PRO™.
NOTE: Over the Side Mounting – Installing a bow line on the transducer will counter the force of the
water pushing the transducer back and will aid the mount pole to remain vertical – see figure 5.
NOTE: Zero depth readings are not recognised as an ERROR condition by the CEEDUCER PRO™.
Regularly observe the depth data being displayed/recorded in the main Survey window to ensure that the
transducer is not reading constant zeros due aeration or other interference.
WARNING: The smart transducer should not be run out of the water for any longer than a few
minutes. Running the transducer in air for extended periods can damage the acoustic accuracy of the
system and result in a less accurate transducer or one that does not work at all.
18
Figure 5: Transducer installation with GPS antenna directly above transducer. Bow line attached to
Transducer Mount
CEE HydroSystems™ suggests placement of the GPS antenna directly above the transducer mounting
so that there is zero horizontal antenna offset to account for (see figure 5). If the antenna is not mounted
directly above the transducer it is necessary to record the horizontal offsets of the GPS antenna from the
transducer, so that this shift can be corrected for in the processing stage.
If there is a survey requirement for RTK GPS usage for the purposes of recording the water level during
the survey, it will also be necessary to record the height of the GPS Antennas zero phase point above
water. This value is recorded in the .CEE file header for use in post processing.
Telemetry Location
If the system is to run with RTK corrections or real time tide corrections it is necessary to send these
corrections from an external source to the CEEDUCER PRO™ on the roving survey vessel. In this case
a telemetry system is needed.
When installing a radio telemetry antenna it is important to keep in oriented correctly according to the
antenna type and, where possible, as far away from the GPS antenna as is reasonably practical.
19
CEEDUCER PRO™ User Manual V3.18.02
Making Connections
The GPS antenna connects to the CEEDUCER PRO™ control unit with a 50-ohm coaxial cable,
terminated at both ends with TNC connectors. The TNC plug screws onto the TNC connector on the
CEEDUCER PRO™ control unit and onto the TNC connector on the GPS antenna. These plugs may be
detached by unscrewing them.
The Transducer connectors are heavy duty 6 pin LEMO plugs, which push and lock directly into the 6 pin
heavy duty LEMO sockets on the left hand side of the unit (see figure 2 in Connections - Left Hand Side).
There is no preference for which transducer plug goes into which transducer socket, as the plugs are
wired differently, and the sockets are wired so each socket can take either plug. Line up the red dot on
the plug with the red dot on the socket, and push the plug in as far as it will go. The plug will lock into
place with a physical click. The LEMO plugs may be detached again by pulling firmly on the knurled
barrel of the plug, which will slide back, and disengage the locking mechanism.
Other devices may also need to be connected, depending on system configuration. Refer to the index of
this manual to locate the relevant information for other device interfacing.
NOTE: Ensure that any unused sockets on the CEEDUCER PRO™ are sealed with their supplied caps,
as open unplugged sockets are not IP-65 rated against water ingress.
NOTE: Do not pull on the cable of anything attached to the CEEDUCER PRO™ unit in order to detach it.
All cables are either screwed or locked into place, and must be detached at the plug. Pulling on the cable
will only risk damage to the cable.
NOTE: Ensure the caps are not squashed when they are disconnected from the socket.
20
Configuration Instructions
Turning the CEEDUCER PRO™ on and off
With all devices connected up correctly, it is time to turn on the system.
The CEEDUCER PRO™ is turned on by pressing the On/Off button for 1 second. Once the button is
pressed, the GPS and Diff LEDs will flash and then a few seconds later the CEEDUCER PRO™ splash
screen will show while the system boots up and configures itself.
The CEEDUCER PRO™ can be turned off again by holding down the On/Off button for 3 seconds and
then releasing it.
After the system has booted up and configured itself, the CEEDUCER PRO™ real time survey screen is
displayed. This screen is designed to display real time data and status information to the Surveyor.
Before a survey can be performed, the CEEDUCER PRO™ system must be configured to survey
specifications. The CEEDUCER PRO™ will start up with the settings used during the last survey.
Critical Settings
It is of critical importance to setup the CEEDUCER PRO™ peripherals to whatever standard is required
by the survey. Incorrect configuration (usually configuration to a lesser performance level than a survey’s
requirements) of the CEEDUCER PRO™ system may not always cause errors to be displayed if the
system is still able to run with whatever configuration is has been set to.
If a survey requires RTK correction, then the Diff Options for the Eclipse RTK receiver must be
configured so that the internal Eclipse receiver is running with RTK correction. See Diff Source
Selection for information on setting your CEEDUCER PRO™ to operate in RTK mode. (If an
external GPS source is being used all settings must be correct on the receiver connected to the
CEEDUCER PRO™.
If a survey requires dual frequency be used, then it is important that the echosounder setup options
are configured for the use of dual transducers. See Internal Echosounder Selection for information
on selecting the frequency/frequencies you require.
Similarly, if a survey requires real time Heave or Tide data to be used then it is important to ensure
that Heave or Tide is enabled in the menu system as required, not just sent into the unit. See
enabling Heave/Tide real time heave and/or tide corrections.
Ensure that the CEEDUCER PRO™ mode is setup for the kind of operation required. Logging a line
with Position Averaging on will not provide any survey depth data.
There are also a couple of other configuration settings that can cause problems with measuring or
logging data if configured incorrectly.
If using temperature based Auto Velocity adjustment, it is important to select the water salinity
correctly for the application. Conversely, if Manual Velocity adjustment is used, then the velocity
entered must be correct for the survey area.
The draft value entered should be correct for the mount position and checked by measuring a
known depth. If the draft is entered incorrectly the data logged/output/displayed will not be a correct
depth below water surface measurement.
21
CEEDUCER PRO™ User Manual V3.18.02
The Time and date setting is very important – if the logged data is to be merged with data logged
elsewhere, then the logged data times are the means by which logged data records are tied to other
time stamped data. On commencement of a survey always check the CEEDUCER PRO™ internal
system clock, and confirm it is correct. The clock is updated from UTC using the UTC offset value
entered in the time setup menu
When operating with RTK GPS, the antenna height should to be recorded in the CEEDUCER
PRO™ (when running in RTK mode only) or in the RTK Rover (when using external RTK GPS) to
avoid confusion at later processing stages.
PC communication settings
If a CEEDUCER PRO™ system is required to interface to a computer during a survey (usually for the
purposes of track guidance, or for logging all data in a survey program such as HYPACK™) then the
communication protocols must be configured.
There are two standard ways to connect a CEEDUCER PRO™ control unit to a PC: either via a serial
port, or via an Ethernet port. The CEEDUCER PRO™ can also be fitted with Bluetooth. This is an option
that must be selected at time of purchase. The communication ports run simultaneously so can supply
real time information to multiple locations if required.
Display settings
These settings are purely for the use of the user, and they do not alter information being sent in real time
or data being logged. All the information needed to make the survey and cover the survey area
adequately can be configured on the display screen to suit the user. See Display Settings for information
on screen configuration.
22
Survey Operation
Log files can be defined, opened and closed. Logging into these can be stopped and started.
It is necessary to go into the Menu System to open and close files, however starting and pausing logging
to an already opened file is accomplished by hitting the F1 button in the real time survey window.
It is also possible to place mark events into the log file. These are used to mark points of interest as they
are noted during the survey, for close examination or particular treatment later.
A mark event can be placed into a log file by momentarily pressing the FIX button on the front panel.
On generation of a mark event flag, a dotted line the entire height of the depth profile section will be
added to the scrolling profile, to confirm where the flag is sitting in relation to the survey depth data.
Additionally, it is also possible to place NEWLINE flags into the log file. These events are useful if a
survey is to be converted to HYPACK™ format after being downloaded. One particular feature of
HYPACK™ logged surveys is their reliance of breaking down logged data into separate files for each
survey line, this process breaks down large amounts of data to smaller, easier to manage files for
TM
processing. A NEWLINE flag in a log file will cause the CEEDATA download and conversion program
to generate multiple .RAW files from a single CEEDUCER PRO™ .CEE file.
A NEWLINE flag can be generated by holding down the FIX button for 5 seconds before releasing it.
On generation of a NEWLINE flag, a solid line the entire height of the depth profile section, will be added
to the scrolling profile, to confirm where the flag is sitting in relation to the survey data.
To perform this function, the CEEDUCER PRO™ must be set to averaging mode (see Mode Selection).
The GPS antenna should be placed in a fixed, unmoving position. Where possible it should be mounted
on a tripod on land (with height of antenna above ground noted for later reference).
When logging is started in averaging position mode, positions received from the GPS are averaged over
the logging time. The position displayed on the main screen is not the averaged position but a continued
read out of position in real time.
To get an averaged position relatively free of the effects of a single bad satellite value, log as many
positions as possible. It is recommended at least 40 minutes for averaging a position where possible.
The raw positions used when calculating an average are recorded in the .CEE file. This allows the raw
data to be analysed to review the positions used to calculate the average result.
Depth values are not used in the averaging process and it is recommended that you disable the
echosounder function prior to averaging a position.
23
CEEDUCER PRO™ User Manual V3.18.02
A CEEDUCER PRO™ log file is downloaded to the computer in ASCII format. Each file contains the
CEEDUCER PRO™ settings used and the position/depth data required for later processing. The files
have an extension “.CEE”. See CEEDUCER PRO™ Log Download Data for information regarding the
.CEE file format.
For serial connections, the download can be done either with CEE HydroSystems™ companion program
TM TM
CEEDATA or any terminal program. See the CEEDATA manual for further information. For FTP
downloads, any FTP client is able to be used.
CEEDATA™ processes the CEEDUCER PRO™ format download files into either processed
CEEDUCER PRO™ format “.CPR” or into a format that can be loaded by HYPACK™ (which is a
collection of “.log” “.RAW” and “.CPR” files)
TM
See the CEEDATA user manual for further information.
Please contact [email protected] for information on the capabilities and the purchasing of
HYPACK™.
24
Reference
Using the real time survey screen
15:22:09 01/07/2009
Grid East: 325298 m Start
Grid North: 6269771 m Logging
1
0
2
0
The largest amount of space on and the most distinguishing feature of this screen is the depth profile
window. This shows a record of the previous echosounder depths versus time in a similar way to a paper
trace chart. The range of depths shown is displayed to the left of the graph If the depth being measured
has moved out of this range it can be scrolled up and down using the (UP) and (DOWN) buttons,
half the range span at a time. For example if the measured depth was to increase to 25m the screen
example above would display a flat line at the 20m profile level. Press the (DOWN) button to change
the profile range to 10-30m and the depth profile will represented correctly.
The CEEDUCER PRO™ system Time and Date are displayed at the top of the window. Time is in 24
hour format, date is in DD/MM/YYYY format.
Below this, the current position as received from the GPS is shown. The GPS provides latitude and
longitude values in relation to the WGS-84 datum. This can be displayed as Degrees Minutes, Seconds,
or in Degrees, Minutes.Decimal format. It may also be shown in Easting and Northing values of a
standard UTM projection (as shown here)
NOTE: That for internal RTK operation, there are no real time transformations or projections done to the
received position data. Position is only displayed as latitude and longitude in degrees decimal minutes.
Below this is a line dedicated to showing the status of whatever kind of GPS correction may be present.
“OK (2)” means that the GPS quality indicator received from the GPS is showing some form of differential
correction. If running an OmniSTAR HP capable system the message OK (2) means you have are
receiving OmniSTAR correction messages. Once the solution has refined to a low SDE value the Diff
message will display FLT (5) indicating the greater accuracy of HP versus a VBS status
25
CEEDUCER PRO™ User Manual V3.18.02
NOTE: If the area you are working in restricts the GPS from being to lower the SDE value (i.e. steep
terrain or structural interference) the Diff status may remain as OK (2) on a HP signal. If possible
relocate the GPS antenna to improve GPS reception therefore increasing the accuracy of the position.
NOTE: Earlier Eclipse receivers may not be running the firmware required for displaying the float solution
for HP signals. Contact CEE HydroSystems™ for further information about your receiver.
If running a RTK capable system in RTK mode (internal Eclipse GPS source) then “RTK (4)” here means
that the GPS quality indicator received from the GPS is showing RTK FIX position solutions. When an
external GPS source is used the display will show Ext (x) where ‘x’ is the quality of the GPS message
being received (1, 2, 4, 5 etc). The SDE field is a measure of the noise in the internal GPS position
calculation. Smaller numbers are better.
Below Diff is a multi-purpose line that shows the status of a lot of parameters and real time information,
depending on system configuration (e.g. Tide will only be displayed if the feature is enabled). These are
displayed one after the other:
At the top right of the screen is the Log Start/Pause indicator. If a file has been opened for logging, then
this indicator shows what the result of pressing the F1 button (located next to the on-screen indicator) will
be. Beneath the button indicator are a series of 3 lines providing more detail on the current logging setup.
The first line indicates the name of the current open logging file (if any). The second line indicates if
logging is active (ON) or not (OFF) and the currently used memory capacity as a percentage. The third
line shows the logging mode. Normally for hydrographic surveying, this will display “Normal”. It will
display “Average” if the CEEDUCER PRO™ is set up for position averaging.
26
Using the Menu System
15:27:30 01/07/2009
Grid East: 325267 m
Grid North: 6269790 m Logging
Diff : OK (2) SDE: 0.40
Sep : 20.40 m
Setup
HF Depth: 23.45 m
LF Depth: 23.56 m
Mode
Select’n
Advanced
The Menu system is be entered by pressing the MENU button while in the real time survey screen. This
will bring up the base menu as shown in Figure 7, above.
Any given menu screen contains the basic real time data display from the Real time Survey Screen at
the top left of the screen. But there is no depth profile display or active log file details.
There can be up to four options displayed down the right hand side of the screen, relating to the function
of the F1, F2, F3, F4 buttons in any particular menu page.
Note that each of these options in a given menu page can either lead to a new menu page (square
corners) or to a parameter setting page (round corners).
A menu can be exited, and the system sent back to the previous menu at any time, by pressing the
CLEAR button.
The Menu system can be set back to the base menu at any time, by pressing the MENU button.
27
CEEDUCER PRO™ User Manual V3.18.02
Normal Mode
Averaging Select’n
Advanced
Entering a parameter edit page from the menu system, the blank area of the menu screen is taken over
by the parameter editing page.
Depending on the type of parameter to be edited, there may be multiple edit positions to be worked with,
even flowing to a series of edit pages (spheroidal transform setup screen, for example) or there may be a
single edit position, (for example, the Operation Mode setup screen in Figure 8, above) If necessary, the
edit position is adjusted with the (RIGHT) and (LEFT) buttons.
The value at the given edit position is incremented or decremented with the (UP) and (DOWN)
buttons.
An edited value will be accepted, and the system will exit the current parameter edit page by pressing the
ENTER button.
Edited values will be discarded and the system will exit the current parameter edit page by pressing the
CLEAR button.
NOTE: Settings are grouped into functional areas, rather than strictly by menu location.
28
GPS positioning input and GPS correction settings
GPS Source
The CEEDUCER PRO™ can be configured to run with its internal GPS receiver, or an external GPS
receiver that outputs NMEA 0183 format GGA VTG and ZDA messages. The talker ID on the external
messages should be ‘$GP’. This setting allows the selection of the Internal GPS or an external GPS.
Menu F4 F1 F1
Internal/External GPS
Internal
External
An example of the correct GPS data configuration is shown in Appendix G – GGA VTG format
NOTE: The baud rate of the CEEDUCER PRO™ external GPS connection must match the baud rate of
the external GPS receiver supplying the data.
Ext GPS
Menu Advanced GPS
Baud
Menu F4 F1 F2
4800
9600
19200
38400
57600
29
CEEDUCER PRO™ User Manual V3.18.02
The internal GPS reset function is used to reset the GPS Almanac data.
Reset
Menu Advanced GPS
GPS
Menu F4 F1 F3
yes
no
RTK Ant
Menu Advanced GPS
Height
Menu F4 F1 F4
1.235 m
NOTE: The antenna height entered here does not alter the displayed height or logged data.
30
Diff source selection
If the Internal GPS is to be used, this selection sets the diff source it is required to run with. The settings
made here will configure the internal GPS to match this and connect the required diff source (if any) to
the internal GPS. Options are selected by the (UP) and (DOWN) buttons and press the ENTER
button to confirm selection.
Diff
Menu Advanced Diff
Source
Menu F4 F2 F1
OmniSTAR HP
Ext RTCMv2 - DGPS
SBAS
Disabled
NOTE: The default setting for External Diff data is to be sent via the External RTCM Input cable. If the
Bluetooth option has been fitted and the RTCM is to be received via Bluetooth you must make this
selection in the PC Comms Menu option (See PC Comms)
Select the desired source of the CEEDUCER PRO™ RTCM correction. Depending on the model of
internal GPS installed in the CEEDUCER PRO™ the options will vary. (The example screen is taken
from a CEEDUCER PRO™ with an internal Hemisphere Crescent GPS). The type of GPS receiver
installed in your CEEDUCER PRO™ is shown in the about screen (see About). Options are selected by
the (UP) and (DOWN) buttons and press the ENTER button to confirm selection
“SBAS”, is a Satellite Based Augmentation System (includes WAAS, EGNOS and MSAS).
“External”, an external RTCM v2.0 source is used. This requires connection to a modem receiving
corrections from a local differential station, or an external marine beacon receiver.
31
CEEDUCER PRO™ User Manual V3.18.02
A12 options:
All of the options listed for the Crescent and DG14, PLUS
“Beacon + SBAS”, marine beacon receiver correction is used preferentially. If it is not available, then
SBAS is used.
“Ext + SBAS”, external RTCM v2.0 correction source is used preferentially. If it is not available, then
SBAS is used.
Eclipse options:
“OmniSTAR HP”, the internal OmniSTAR HP (L-band) receiver is selected to generate corrections.
“Ext RTCM V2.0-DGPS”, an external RTCM v2.0 source is used. This requires connection to a
modem receiving corrections from a local differential station, or an external marine beacon receiver.
“SBAS” ”, is a Satellite Based Augmentation System (includes WAAS, EGNOS and MSAS).
“Ext RTCMv3 – RTK” - An RTCMv3 source is used. Such as a modem receiving corrections from a
local RTK base or network RTK data streamed via a device with an internet connection.
“Ext RTCM v2.0 – DGPS” - An external RTCM v2.0 source is used. This requires connection to a
modem receiving corrections from a local differential station, or an external marine beacon receiver.
“OmniSTAR HP” The internal OmniSTAR HP (L-band) receiver is selected to generate corrections.
NOTE: A valid subscription is required to receive an OmniSTAR correction. Contact CEE HydroSystems
for OmniSTAR subscription information.
NOTE: The CEEDUCER PRO™ must be switched on in an area of clear sky, set to OmniSTAR
differential mode and have a position displayed on screen before a signal subscription can be activated.
32
External RTCM baud rate
If external Diff is configured to be used then this setting will configure the internal GPS to receive RTCM
data at the baud rate to match the external RTCM source. Options are selected by the (UP) and
(DOWN) buttons and press the ENTER button to confirm selection.
Ext RTCM
Menu Advanced Diff
Baud
Menu F4 F2 F2
4800
9600
19200
38400
57600
Beacon
Menu Advanced Diff
Mode
Menu F4 F2 F3
Automatic
Manual
NOTE: The internal Marine Radio Beacon can bet set to scan the entire frequency range for the
available receive frequency of the RTCM corrections. If operating in area with a poor marine Beacon
reception it advisable to manually set the known frequency of the desired reference station. If the
reception drops out the receiver will stay on the set frequency until RTCM corrections are available
again, and will not scan up and down the frequency range.
NOTE: If operating in an area where reception from more than one Marine Beacon is available, use the
manual frequency option to prevent the beacon receiver hopping between frequencies.
WARNING: Marine Beacon transmitters do not all send corrections to WGS-84. Receiving and
using their corrections in a GPS receiver can reference GPS position to the datum used by the Marine
Beacon. It is recommended that Marine Beacon data is not used without first researching the beacon
configuration and understanding what this beacon’s corrections will do to received GPS positions.
33
CEEDUCER PRO™ User Manual V3.18.02
Beacon
Menu Advanced Diff
Freq.
Menu F4 F2 F4
WARNING: Marine Beacon transmitters do not all send corrections to WGS-84. Receiving and
using their corrections in a GPS receiver can reference GPS position to the datum used by the Marine
Beacon. It is recommended that Marine Beacon data is not used without first researching the beacon
configuration and understanding what this beacon’s corrections will do to received GPS positions.
34
OmniSTAR HP Mode (Eclipse and Eclipse RTK only)
If an Eclipse receiver is to be configured to run on OmniSTAR HP corrections then this setting is used to
select automatic satellite reception or manual satellite reception. Options are selected by the (UP) and
(DOWN) buttons and press the ENTER button to confirm selection.
OmniStar OmniStar
Menu Advanced Diff
Setup Mode
Menu F4 F2 F3 F1
Auto
manual
OmniStar OmniStar
Menu Advanced Diff
Setup Freq.
Menu F4 F2 F3 F2
Satellite Frequency
1520.0000 MHz
35
CEEDUCER PRO™ User Manual V3.18.02
OmniStar OmniStar
Menu Advanced Diff
Setup baud
Menu F4 F2 F3 F3
It allows the Eclipse receiver serial number to be read which is needed for enabling an OmniSTAR HP
subscription for the Eclipse. It also shows the current OmniSTAR HP subscription expiration date
(expiration date is related to UTC day boundary)
OmniStar OmniStar
Menu Advanced Diff
Setup Details
Menu F4 F2 F3 F4
OmniStar Information
Subscription valid to
30 Apr 2009
NOTE: Subscription end time is not available if the “Diff Source” selection is set to something other than
OmniSTAR HP.
NOTE: The serial number on the front panel of a CEEDUCER PRO™ is not the serial number of the
GPS and will not be recognised by OmniSTAR. You must use the GPS serial number as described
above.
36
Echosounder input, and sound velocity correction
Echosounder Source
This setting page allows the selection of internal echosounders (CEEDUCER PRO™ smart transducers),
External echosounder, or no echosounders. Options are selected by the (UP) and (DOWN) buttons
and press the ENTER button to confirm selection.
Connectd
Menu Setup Echosounder E/S Source
E/S
Menu F2 F3 F1 F1
NOTE: Select the echo sounder source from Internal or External. If it is necessary to survey water
deeper than 99.99 meters, an external echo sounder capable of measuring these depths may be
connected via an External echo sounder cable.
37
CEEDUCER PRO™ User Manual V3.18.02
Internal Selection
If CEEDUCER PRO™ smart transducers are being used this setting page allows selection of either HF
(200 kHz) or LF (30 kHz) or both frequency unit inputs. Options are selected by the (UP) and
(DOWN) buttons and press the ENTER button to confirm selection.
Connectd Internal
Menu Setup Echosounder
E/S Select'n
Menu F2 F3 F1 F2
HF Only
LF Only
HF & LF
WARNING: Ensure the Echosounder Selection is set to match the requirements of the survey. If
dual echosounders are connected but only the HF sounder or the LF sounder is selected in this setting
page then only the HF or LF data is logged displayed on the main survey screen.
External Selection
If an external echosounder device is being used, this setting page allows the selection of the serial data
format used to transmit the depth values. Examples of the data formats accepted by the CEEDUCER
PRO™ are shown in Appendix G. Options are selected by the (UP) and (DOWN) buttons and press
the ENTER button to confirm selection.
NOTE: The CEEDUCER PRO™ will not adjust external echosounder data for draft, index offset and/or
velocity.
Connectd External
Menu Setup Echosounder
E/S Select'n
Menu F2 F3 F1 F3
ODOM
NEMA DBS
38
External baud
If an external echosounder device is being used, this setting page allows the selection of the baud rate
used to transmit the depth values. Options are selected by the (UP) and (DOWN) buttons and press
the ENTER button to confirm selection.
Connectd External
Menu Setup Echosounder
E/S Baud
Menu F2 F3 F1 F4
4800
9600
19200
38400
57600
Configure the external echo sounder baud rate match the RS232 baud rate of the connected external
echosounder.
NOTE: RS232 serial data should be supplied as follows; Data bits=8, Parity=none, Stop bits=1, Flow
control=None.
Velocity Mode
If CEEDUCER PRO™ smart transducers are being used the sound velocity value can be set to
automatic mode using one of three best fit options for water salinity or the choice to use a manually set
velocity value. Automatic modes (Sea, Fresh or Brackish) will correct velocity for temperature change in
the survey area (for example estuary areas). Options are selected by the (UP) and (DOWN) buttons
and press the ENTER button to confirm selection.
Menu F2 F3 F2 F1
Select A Mode
Manual
Sea
Fresh
Brackish
NOTE: Auto velocity is effective up to 10m water depth. Deeper Survey areas should use a calibrated
velocity metre or full bar check procedure to attain an accurate velocity for the survey area.
NOTE: Depth data from an external echosounder is not adjusted for velocity by the CEEDUCER PRO™.
39
CEEDUCER PRO™ User Manual V3.18.02
Manual Velocity
If CEEDUCER PRO™ smart transducers are being used with a manual velocity value this setting page
allows the manual velocity to be set to a fixed value as measured by a calibrated device or calculated
using known values. Velocity range is 1400m/s to 1700m/s. Options are selected by the (UP) and
(DOWN) buttons and press the ENTER button to confirm selection.
Velocity Manual
Menu Setup Echosounder
Select'n Velocity
Menu F2 F3 F2 F2
1528 m/s
HF E/S Draft
If CEEDUCER PRO™ smart transducers are being used this setting page allows the recording of the
depth of the HF transducer face below the surface of the water so that echosounder distance
measurements can be turned into water depth measurements. Options are selected by the (UP) and
(DOWN) buttons and press the ENTER button to confirm selection.
HF E/S
Menu Setup Echosounder E/S Draft
Draft
Menu F2 F3 F3 F1
HF EchoSounder Draft
0.300 m
NOTE: Depth data from an external echosounder is not corrected for draft by a CEEDUCER PRO™
40
LF E/S Draft
If CEEDUCER PRO™ smart transducers are being used this setting page allows the recording of the
depth of the LF transducer face below the surface of the water so that echosounder distance
measurements can be turned into water depth measurements. Options are selected by the (UP) and
(DOWN) buttons and press the ENTER button to confirm selection.
Menu F2 F3 F3 F2
LF EchoSounder Draft
0.300 m
NOTE: Depth data from an external echosounder is not corrected for draft by a CEEDUCER PRO™
Index Offset
The reference point of a transducer is the bottom face of the unit. Transducers may, however, vary with
the exact zero point from batch to batch. This is known as an index offset and is not a fault with the
transducer. When a CEEDUCER PRO™ system is configured with the correct draft and velocity as
measured the index offset value can be adjusted to correct for any difference that may occur between
transducers.
NOTE: Ensure Draft and Sound Velocity is correct prior to adjusting Index Offset. An incorrect draft
and/or sound velocity will give a different depth reading against a known target depth.
HF E/S Offset
Once the draft and velocity have been measured and entered place a target at a known depth below the
transducer. Use the Index Offset value to adjust the depth reading to match the known depth. Options
are selected by the (UP) and (DOWN) buttons and press the ENTER button to confirm selection.
The Index Offset can only be a positive number.
Menu F2 F3 F3 F3
Echo HF E/S
Menu Setup E/S Draft Offset
Sounder
HF EchoSounder Offset
0.020 m
NOTE: Ensure the Draft and Sound Velocity are both correct before adjusting the Index Offset
41
CEEDUCER PRO™ User Manual V3.18.02
LF E/S Offset
Once the draft and velocity have been measured and entered place a target at a known depth below the
transducer. Use the Index Offset value to adjust the depth reading to match the known depth. Options
are selected by the (UP) and (DOWN) buttons and press the ENTER button to confirm selection.
The Index Offset can only be a positive number
Menu F2 F3 F3 F4
LF EchoSounder Offset
0.010 m
NOTE: Ensure the Draft and Sound Velocity are both correct before adjusting the Index Offset
Menu F2 F3 F4 F1
Off
On
NOTE: this setting does not affect logged data records or real time serial output data.
42
Max Depth Value
If the MAX DEPTH setting is activated, this setting page allows the setting of the value over which depths
will be not displayed on the screen in real time. Value limit that can be set is 100.0 metres. Options are
selected by the (UP) and (DOWN) buttons and press the ENTER button to confirm selection.
Menu F2 F3 F4 F2
10.0 m
NOTE: this setting does not affect logged data records, or real time serial output data.
Heave Enable
This setup page allows the enabling of heave input data for real-time echosounder depth adjustment and
for logging. Examples of the data formats accepted by the CEEDUCER PRO™ are shown in Appendix
G. Options are selected by the (UP) and (DOWN) buttons and press the ENTER button to confirm
selection.
Menu F4 F4 F1 F1
NOTE: Depth data from an external echosounder is not corrected for heave by the CEEDUCER PRO™.
43
CEEDUCER PRO™ User Manual V3.18.02
Heave baud
This setup page allows configuration of the baud rate that tide input data is to be received at. Options are
selected by the (UP) and (DOWN) buttons and press the ENTER button to confirm selection.
Heave /
Menu Adanced Heave Input Heave Baud
Tide I/P
Menu F4 F4 F1 F2
4800
9600
19200
38400
57600
Tide Enable
This setup page allows the enabling of tide input data for echosounder depth re-referencing and for
logging. Examples of the data formats accepted by the CEEDUCER PRO™ are shown in Appendix G.
Options are selected by the (UP) and (DOWN) buttons and press the ENTER button to confirm
selection.
Heave /
Menu Adanced Tide Input Enable Tide
Tide I/P
Menu F4 F4 F2 F1
Off
On
NOTE: Depth data from an external echosounder is not corrected for tide by the CEEDUCER PRO™
44
Tide Baud
This setup page allows configuration of the baud rate that tide input data is to be received at. Options are
selected by the (UP) and (DOWN) buttons and press the ENTER button to confirm selection.
Heave / Tide
Menu Adanced Tide Input Tide Baud
I/P
Menu F4 F4 F2 F2
System
Mode Selection
The Mode of the CEEDUCER PRO™ unit can be selected for it to operate in different ways. This sets
the fundamental operation mode of the CEEDUCER PRO™ and therefore what is logged and how it is
logged. Options are selected by the (UP) and (DOWN) buttons and press the ENTER button to
confirm selection.
Mode
Menu
Select'n
Menu F3
Normal
Averaging
Storage Mode
45
CEEDUCER PRO™ User Manual V3.18.02
The CEEDUCER PRO™ will display the available modes applicable to its configuration. (i.e., storage
mode is not available on Lead Acid battery systems)
Normal – This mode will be used to collect GPS & Bathymetric data (Normal operation).
Averaging – This mode is used to log an averaged GPS position for a static point. It is
recommended to use two separate observation periods, one in the day and one at night to allow for
different atmospheric conditions be used to create the reference position. A minimum of 40 minutes
of GPS data should be used for each observation. The logged .CEE file in the CEEDUCER PRO™
will include the individual GPS points used to calculate the average position recorded. The two
results can then be reviewed to gain a reference point.
NOTE: The position displayed on the screen is updated with each GPS input. This position is not
the average position calculated by the CEEDUCER PRO™
Storage Mode – This mode will enable the CEEDUCER PRO™ to drain the battery to 30% before
powering itself off. To cancel the mode power cycle the unit using the ON/OFF button or ENTER the
Menu System again, go to the Mode Selection Setup Page and select a different System Mode
(normal or averaging).
NOTE: If the CEEDUCER PRO™ has 30% battery capacity or less the unit will immediately switch
off when storage mode is selected.
NOTE: Storage mode is only available on NiMH systems running firmware 3.16 or earlier.
This Setting page allows the manual setting of the system time. The system time as displayed is used for
time stamping data records in log files. Select the field with the (RIGHT) and (LEFT) buttons, and
the value at the given edit position is incremented or decremented with the (UP) and (DOWN)
buttons. ENTER will accept the current setting.
Menu F2 F1 F1 F1
NOTE: System date and time is automatically corrected to GPS time once a position has been acquired
after start up. (UTC +/- offset as entered in UTC offset menu).
46
GPS Time Correction
UTC Offset
A UTC offset can be applied to update date and time of the CEEDUCER PRO™ system to match your
local time zone. The offset can be a positive or negative number entered as hh:mm (in 15 minute
increments). Select the field with the (RIGHT) and (LEFT) buttons, and the value at the given edit
position is incremented or decremented with the (UP) and (DOWN) buttons. ENTER will accept the
current setting. The UTC offset value is stored by the CEEDUCER PRO™ to be used on each start up.
Menu F2 F1 F1 F2
-08:15 UTC
NOTE: You must enter the appropriate UTC offset for your location. The system will not automatically
change the UTC offset if you have changed time zones.
NOTE: A GPS signal must be obtained before date and time are updated.
NOTE: After a System Reset the UTC offset will go to the default setting of 00:00 hrs
47
CEEDUCER PRO™ User Manual V3.18.02
System reset
This setting page allows the selection of the System Reset function. It will return all settings of a
CEEDUCER PRO™ system to their default values and then turn the unit off. This function should never
need to be used but is provided as an option to bring back a CEEDUCER PRO™ to a known
configuration with one-step. Options are selected the (UP) and (DOWN) buttons and press the
ENTER button to confirm selection.
Menu F2 F1 F2
WARNING: After execution, all settings are reset to defaults, and deleted log data cannot be
recovered. Ensure any survey data on the unit has been downloaded and backed up to multiple
locations, and that all important settings have been recorded before performing this operation.
NOTE: Re-enter all system parameters prior to performing your survey. All draft, velocity, GPS,
Differential mode and system date/time functions will be set to default values after a system reset is
performed.
NOTE: The default settings of a CEEDUCER PRO™ are internal GPS, diff function listed at top of diff
source list, auto sound velocity for salt water, zero draft and index offset of transducers, heave and tide
inputs disabled, default WGS84 and UTM position display parameters, UTM grid position display on the
screen, UTC clock offset to zero hours, no real time output data.
48
About
This is not a setting, but an informational display page. It shows the firmware revision, GPS receiver type
and battery option installed in the CEEDUCER PRO™ unit. It will also show if Bluetooth is available in
the unit.
Menu F2 F1 F3
www.bruttour.com.au
NOTE: the presence of (NiMH) at the top right of the page indicates it is a Nickel metal Hydride system.
Lead Acid battery systems do not have this tag. The firmware revision and GPS receiver installed are
indicated at the bottom of the page.
NOTE: The presence of “Bluetooth Available” at the bottom of the page indicates that the optional
Bluetooth module has been fitted and is capable of sending survey data and/or receiving RTCM data. If it
is not displayed then the Bluetooth connections options are not available.
49
CEEDUCER PRO™ User Manual V3.18.02
Display
Position Format
The real time position display can be given in spherical co-ordinates (Latitude, Longitude) as received
directly from the GPS, or in the case of non-RTK quality GPS positions this can be projected to a
standard UTM grid. Options are selected by the (UP) and (DOWN) buttons and press the ENTER
button to confirm selection.
The setting control provides display in Grid, degrees minutes seconds (Deg Min Sec) or degrees decimal
minutes (Deg Min Dec).
Menu F2 F4 F1
Position
Menu Setup Screen
Format
Grid or Long/lat
Grid
Deg Min Sec
Deg Min Dec
Profile Range
The range of depths shown on the real time profile display can be set to any of 5m, 10m, 15m, 20m,
25m, 50m, or 100m. Depths falling outside of the profile range are shown in the real time depth profile as
a flat line at the top or bottom of the screen, depending on the measured depth being deeper or
shallower then the profile range. The profile range in the main survey screen can be adjusted using the
(UP) and (DOWN) buttons during the survey. This will adjust the depth range in view by half the set
profile range. The depth profile range options are selected by the (UP) and (DOWN) buttons and
press the ENTER button to confirm selection.
Menu F2 F4 F2
50
Screen Saver
It’s possible to setup the CEEDUCER PRO™ so that it automatically turns off the display when not being
used. This is useful when the CEEDUCER PRO™ is not being watched directly, and turning off the
screen will conserve system power. When value is set to zero (0) the screen saver is disabled and
screen will remain on at all times. Options are selected by the (UP) and (DOWN) buttons and press
the ENTER button to confirm selection. The screen saver function does not alter the LED operation on
the front panel and the system will continue to log and send data in real time as normal. After the screen
has timed out and gone blank press the DISPLAY button to reactivate the screen.
Menu F2 F4 F3
0 mins
Speed Units
This setting screen selects the display of real time survey speed in either knots (nautical miles/hr) or
km/h on the main survey screen. The real time survey speed is taken from the real time data provided in
the VTG string of the GPS module. This setting does not affect the data speed sent via real time data out
or logged data. The default unit for speed is knots. Options are selected by the (UP) and (DOWN)
buttons and press the ENTER button to confirm selection.
Menu F2 F4 F4
51
CEEDUCER PRO™ User Manual V3.18.02
NOTE: Spheroid shift will only change the position displayed on the screen. Data is logged and output in
default format.
NOTE: When operating as an RTK receiver the position is only displayed as WGS84.
Geodetic
Menu Advanced Spheroid
Setup
Menu F4 F3 F1
WGS84
User
If WGS84 is selected the parameters are set to not perform any shift.
If User is selected, then a series of 9 setting pages follows. Each page has a multi position value where
the position is set with the (RIGHT), and (LEFT) buttons, and the value at the given edit position is
incremented or decremented with the (UP) and (DOWN) buttons. ENTER will accept the current
setting, and move to the next one, while CLEAR will cancel the current setting, and move to the previous
one.
WGS84 WGS84
User User
Dx Shift Dy Shift
0.000 0.000
Parameter 3/9 Parameter 4/9
52
Set spheroid params Set spheroid params
WGS84 WGS84
User User
Dz Shift Rx Rotation
0.000 0.000
Parameter 5/9 Parameter 6/9
XYZ Scale
0.000
Parameter 9/9
Geodetic
Menu Advanced UTM
Setup
Menu F4 F3 F2
Default
User
If Default is selected, then the parameters are set to perform a projection to UTM, based on the location
of the unit.
If User is selected, then a series of 5 setting pages follows. Each page has a multi position value where
the position is set with the (RIGHT), and (LEFT) buttons, and the value at the given edit position is
incremented or decremented with the (UP) and (DOWN) buttons.
53
CEEDUCER PRO™ User Manual V3.18.02
Default Default
User User
Default Default
User User
Default
User
False North
10000000
Parameter 5/5
PC Comms Port
This setting page sets the data serial port to either be the physical connector on the CEEDUCER PRO™
or the Bluetooth module (if installed). A CEEDUCER PRO™ with Bluetooth installed is identified in the
About screen. Options are selected by the (UP) and (DOWN) buttons and press the ENTER button
to confirm selection.
Menu F2 F2 F1
PC Comms
Menu Setup Comms
Port
PC Interface selection
NOTE: While Bluetooth communication is enabled, the data output from the CEEDUCER PRO™ is still
available on the physical RS232 data output connector, but the baud rate is fixed at 57600.
54
RT O/P Baud
This setting page configures the baud rate to be used, if the physical RS232 data out port of the
CEEDUCER PRO™ is selected. Options are selected by the (UP) and (DOWN) buttons and press
the ENTER button to confirm selection.
Menu F2 F2 F2
4800
9600
19200
38400
57600
NOTE: That while the serial port speed is selectable, the rest of the port common port configuration
parameters are always set to 8,N,1 (8 Data bits, No Parity, and 1 Stop Bit) and cannot be changed.
NOTE: This does not alter the Bluetooth data baud rate (if fitted).
Output Format
This setting page allows a combination of output data types to be selected for real time output.
GGA Each valid NMEA 0183 format GGA string as received from the GPS is echoed to the
system output.
GST Each valid NMEA 0183 format GST string as received from the GPS is echoed to the
system output (only for some versions of the CEEDUCER PRO™)
VTG Each valid NMEA 0183 format VTG string as received from the GPS is echoed to the
system output.
ZDA Each valid NMEA 0183 format ZDA string as received from the GPS is echoed to the
system output (only for some versions of the CEEDUCER PRO™)
DBS NMEA format DBS (Depth Below Surface) string is generated from each real time depth
measurement or received external echosounder message.
DBT NMEA format DBT (Depth Below Transducer) string is generated from each real time
depth measurement or received external echosounder message. Draft is not included in
this message when using internal echosounder.
ODOM Either an ODOM Echotrac DBT (Dual Bottom Tracking) (in the case of a dual depth
system) OR an ODOM Echotrac SBT (Single Bottom Tracking) (in the case of a system
running with single depths) format string is generated from each real time depth
measurement or received external echosounder depth message.
ATLAS DESO Atlas DESO25 format depth strings are generated from real time depth measurements or
received external echosounder depth messages.
55
CEEDUCER PRO™ User Manual V3.18.02
The output combination selections available are as shown in the page diagram. Options are selected by
the (UP) and (DOWN) buttons and press the ENTER button to confirm selection.
Menu F2 F2 F3
Output
Menu Setup Comms
Format
NOTE: This list outlines the expanded list of output formats available with Firmware version 3.16. Earlier
revisions of firmware may not offer the complete list shown above.
NOTE: Options with ZDA work with a PPS signal for synchronising computers. This PPS signal is only
available via a Data Output Cable with PPS identified on the cable label.
NOTE: All GGA, VTG, ZDA GPS messages and DBS/DBT sent from the CEEDUCER PRO™ are
standard NMEA 0183 format.
NOTE: Details on the specific structure of messages, and examples of different output format
combinations are contained in the section CEEDUCER PRO™ Real time Output Data
56
IP Address
This setting page allows the setting of the IP address of the CEEDUCER PRO™ Ethernet port. The field
to be edited is set with the (RIGHT) and (LEFT) buttons, and the value at the given edit position is
incremented or decremented with the (UP) and (DOWN) buttons
Menu F2 F2 F4
192.168. 0. 1
This Ethernet IP address is used for log file downloading via FTP and for real time data transmission via
UDP.
57
CEEDUCER PRO™ User Manual V3.18.02
Create New
Menu Logging Files
Files
Menu F1 F1 F1
River5. CEE
Close File
This setting page allows an option to be selected to close the currently open file. If no file is open, this
setting page reports that there is nothing open for it to close. Once a file is closed a new file must be
created before the CEEDUCER PRO™ will log data. Options are selected by the (UP) and (DOWN)
buttons and press the ENTER button to confirm selection.
Menu F1 F1 F2
NOTE: A log file must be closed before critical settings can be changed (draft, GPS source etc)
58
Download Files
This setting page allows the selection of any single file or all files for download via serial port.
On pressing ENTER the CEEDUCER PRO™ will commence transmission of the selected file(s)
immediately. Files are transmitted at the baud rate configured for the external RS232 data port, as
described in the RT O/P Baud section. Options are selected by the (UP) and (DOWN) buttons and
press the ENTER button to confirm selection. When data is downloading there is an option to abort the
download by pressing the ENTER button.
Download
Menu Logging Files
Files
Menu F1 F1 F3
Download File/s
1 – 000001.CEE
2 – 000002.CEE
All - Files
NOTE: Downloading logged data via Ethernet is controlled by the FTP program being used.
Clear Log
This setting page allows the clearing of all log data currently stored in the unit. Selecting Yes and
pressing the ENTER button will perform the erase process. Options are selected by the (UP) and
(DOWN) buttons and press the ENTER button to confirm selection.
Menu F1 F1 F4
WARNING: After execution logged data cannot be recovered. Ensure any survey data on the unit
has been downloaded and backed up before performing this operation
NOTE: The settings entered in the CEEDUCER PRO™ (e.g. draft) are not deleted when clearing logged
data.
59
CEEDUCER PRO™ User Manual V3.18.02
NOTE: The Event number sequence does not restart with each new log file. For example 000001.CEE
contains events 1-25, 000002.CEE contains events 26-30 and so on.
Next Event
Menu Logging Events
No.
Menu F1 F2 F1
Event No.
Menu Logging Events
Increment
Menu F1 F2 F2
60
Operational Considerations
Echosounder Bar Check
A bar-check is called a bar-check, simply because on bigger boats with an inboard transducer, it was
necessary to suspend a metal 'bar' from two wires either side of the hull to ensure that the bar could be
positioned under the transducer. For an outboard transducer a single metal plate with a single support
line is more convenient.
The plate needs to be big enough to give a good echo return, normally a 50cm diameter circular or
square plate is the minimum size required.
Use thin wire or nylon rope to suspend the plate, and thin (stainless) steel wire for the measured wire.
Mark the suspending line every two metres, try strips of insulating tape, one for 2 metres, 2 strips for 4
metres and so on.
BAR-check procedure:
Measure and note the depth of the transducer face to the water line (draft setting), and mark the
pipe at the water line (for future reference).
Lower the plate underneath the transducer at a shallow setting (i.e. say 2 metres below the water
surface), the echo sounder should then indicate the correct depth, confirming that the draft setting is
correct, adjust the draft setting if necessary. The velocity can be approximate at this stage because
the velocity is less critical at shallow depth readings.
Lower the plate as deep as you can whilst retaining the plate echo (say to 10 or 15 metres), and
then adjust the velocity in the CEEDUCER to obtain the correct water depth reading. Increasing the
velocity value entered will give a greater depth reading.
Bring the plate up in steps of say 2 metres checking against markings to verify that the CEEDUCER
PRO™ is indicating the same depths and therefore that the velocity entered is correct.
Do the bar-check in deep water if possible; the plate needs to be lowered directly underneath the
transducer. Be aware that if there is some water current, or wind moving the boat the plate may swing
outside the echo sounder acoustic 'cone' and echo will be lost. Also be aware that by design the
Echosounder searches for the strongest echo. This is usually the echo from the seabed or river bottom in
preference to the echo from the plate.
For the purpose of acoustic calibration the CEEDUCER PRO™ allows the USER to blank out the bottom
echo altogether. To use this facility Press MENU, F2 to go to the SET-UP Menu, then F3 for E/S, then F4
for E/S Max depth. Set the max depth to a couple of metres above the seabed. Then do you bar check
starting just above the maximum depth value entered.
Setting the max depth value only affects the display. If the echo sounder does not lock onto the plate
then the display shows <???? > . The echo sounder must lock onto the plate (albeit briefly) to return a
valid depth from the bar-check.
61
CEEDUCER PRO™ User Manual V3.18.02
Remember to return to normal operation on completion of the bar-check, i.e. remember to remove the
maximum depth entry.
10m or deeper, 10
set velocity.
62
Equipment care
On completion of survey using the outboard transducer assembly rinse off the transducer assembly with
fresh water and allow to dry thoroughly before storage, this will reduce corrosion. Wipe down
CEEDUCER PRO™ control unit with a damp cloth to remove any salt or dust/dirt that may have
accumulated during the survey. At regular intervals inspect LEMO connectors to ensure they remain
clean. Use a small amount of silicone gel on the o-rings of the LEMO caps to prolong the service life. If
the o-ring is left to dry out it can crack and disintegrate meaning the socket is no longer protected from
the surrounding environment.
Depending on the external equipment to be connected, and the purposes for which the CEEDUCER
PRO™ is being used, a selection of combinations of different output formats can be chosen from.
For instance, if the CEEDUCER PRO™ is to be used with HYPACK™ survey software, where the
CEEDUCER PRO™ is logging the survey and HYPACK™ is providing track guidance, then selecting the
combination of NMEA GGA, GST and VTG data will result in this information being sent from the
CEEDUCER PRO™ via the serial port in RS232, and via Ethernet, in UDP packets.
Alternatively, if the CEEDUCER PRO™ is to be used with HYPACK™ survey software, where the
computer is logging position and depth data the output format GGA, VTG+ODOM would be selected to
use the CEEDUCER PRO™ driver available in HYPACK™. Data should be logged in the CEEDUCER
PRO™ in conjunction with the computer software to give a back up set of data.
63
CEEDUCER PRO™ User Manual V3.18.02
$GPGGA,020704.00,3341.85894619,S,15106.89836423,E,2,09,1.2,159.173,M,20.417,M,5.8
,0003*58
$GPVTG,48.70,T,,M,0.07,N,0.14,K,D*01
$GPZDA,020704.00,09,09,2010,00,00*64
$GPGGA,020705.00,3341.85894701,S,15106.89836436,E,2,09,1.2,159.184,M,20.417,M,6.2
,0003*54
$GPVTG,119.32,T,,M,0.03,N,0.06,K,D*35
$GPZDA,020705.00,09,09,2010,00,00*65
This data comes in on the GPS/RTCM socket, via an external RTCM data cable.
See Appendix G Data formats for an explanation of the information contained in the data string.
64
Echosounder Data
The CEEDUCER PRO™ is able to accept real time depth information in a number of formats via an Ext
ECHOSOUNDER cable connected one of the echosounder ports.
et B 202 210
et B 202 212
et B 200 209
et B 200 209
et B 201 208
et B 201 209
et 201
et 200
et 202
et 203
et 201
et 201
NOTE: this message is ended with a single carriage return character, and no linefeed. On viewing this
real time data in a terminal window that is not automatically adding a linefeed, this will have the effect of
rewriting new messages on the same line over and over, instead of having them scroll up the screen as
shown in the example data given here.
NOTE: The CEEDUCER PRO™ will automatically recognise single frequency or dual frequency data
from the external source
NOTE: The draft, velocity, heave and/or tide correction settings are not applied to external echosounder
data. The CEEDUCER PRO™ assumes that these corrections have been applied by the external device.
65
CEEDUCER PRO™ User Manual V3.18.02
NMEA DBS
If the CEEDUCER PRO™ is set to receive external echosounder in NMEA Depth Below Surface format,
then NMEA DBS format data carrying single depth information will be decoded as real time HF depth
values. See Appendix B Data formats for an explanation of the information contained in the data string.
$SDDBS,,f,7.62,M,,F*32
$SDDBS,,f,7.59,M,,F*3A
$SDDBS,,f,7.56,M,,F*35
$SDDBS,,f,7.53,M,,F*30
$SDDBS,,f,7.50,M,,F*33
$SDDBS,,f,7.47,M,,F*35
NOTE: The draft, velocity, heave and/or tide correction settings are not applied to external echosounder
data. The CEEDUCER PRO™ assumes that these corrections have been applied by the external device.
Tide data
The CEEDUCER PRO™ is designed to take tide data in SHORT ASCII (output type 2) format from a
TM
CEETIDE unit. This comes in on the HEAVE/TIDE socket. See Appendix B Data formats for an
explanation of the information contained in the data string.
15:02:35 -0.82
15:02:40 -0.82
15:02:45 -0.82
15:02:50 -0.82
Heave data
The CEEDUCER PRO™ accepts heave data in TSS1 format. This data may contain acceleration, pitch,
and roll information too. But the CEEDUCER PRO™ does not use this other data. See Appendix B Data
formats for an explanation of the information contained in the data string.
NOTE: The heave device must be supplying a settled heave value denoted by a capital “U” or “G” in the
second field. An error message will be displayed on the CEEDUCER PRO™ if the device is not settled
(indicated by a lower case “u” or “g”. Refer to the MRU manual for further details.
66
CEEDUCER PRO™ Real time Output Data combinations
The CEEDUCER PRO™ allows for a selection of combinations of data types and formats to output.
NMEA GGA
$GPGGA,055947.00,3341.85918,S,15106.89772,E,2,07,1.3,157.38,M,20.4,M,4,0003*7C
$GPGGA,055948.00,3341.85916,S,15106.89773,E,2,07,1.3,157.35,M,20.4,M,3,0003*76
$GPGGA,055949.00,3341.85915,S,15106.89774,E,2,07,1.3,157.32,M,20.4,M,3,0003*74
$GPGGA,055950.00,3341.85914,S,15106.89776,E,2,07,1.3,157.32,M,20.4,M,3,0003*7F
$GPGGA,055947.00,3341.85918,S,15106.89772,E,2,07,1.3,157.38,M,20.4,M,4,0003*7C
$GPVTG,013,T,000,M,000.0,N,000.0,K,D*24
$GPGGA,055948.00,3341.85916,S,15106.89773,E,2,07,1.3,157.35,M,20.4,M,3,0003*76
$GPVTG,013,T,000,M,000.0,N,000.0,K,D*24
$GPGGA,055949.00,3341.85915,S,15106.89774,E,2,07,1.3,157.32,M,20.4,M,3,0003*74
$GPVTG,013,T,000,M,000.0,N,000.0,K,D*24
$GPGGA,055950.00,3341.85914,S,15106.89776,E,2,07,1.3,157.32,M,20.4,M,3,0003*7F
$GPVTG,013,T,000,M,000.0,N,000.0,K,D*24
67
CEEDUCER PRO™ User Manual V3.18.02
$GPGGA,060158.00,3341.85907,S,15106.89817,E,2,07,1.3,157.31,M,20.4,M,3,0003*70
$GPVTG,013,T,000,M,000.0,N,000.0,K,D*24
et B 1285 1285
et B 1279 1279
et B 1276 1276
et B 1273 1273
et B 1264 1268
$GPGGA,060159.00,3341.85907,S,15106.89817,E,2,07,1.3,157.29,M,20.4,M,3,0003*78
$GPVTG,013,T,000,M,000.0,N,000.0,K,D*24
et B 1261 1261
et B 1260 1260
et B 1257 1257
et B 1252 1252
et B 1249 1249
et B 1243 1243
$GPGGA,060200.00,3341.85909,S,15106.89817,E,2,07,1.3,157.31,M,20.4,M,3,0003*70
$GPVTG,013,T,000,M,000.0,N,000.0,K,D*24
$GPGGA,060158.00,3341.85907,S,15106.89817,E,2,07,1.3,157.31,M,20.4,M,3,0003*70
$GPVTG,013,T,000,M,000.0,N,000.0,K,D*24
et 201
et 200
et 202
et 203
et 201
et 201
$GPGGA,060159.00,3341.85907,S,15106.89817,E,2,07,1.3,157.29,M,20.4,M,3,0003*78
$GPVTG,013,T,000,M,000.0,N,000.0,K,D*24
et 201
et 203
et 204
et 202
et 205
et 206
68
GGA + VTG + DBT
$GPGGA,060308.00,3341.85922,S,15106.89809,E,2,07,1.3,156.69,M,20.4,M,2,0003*72
$GPVTG,013,T,000,M,000.0,N,000.0,K,D*24
$SDDBT,,f,016.56,M,,F*32
$SDDBT,,f,016.51,M,,F*35
$SDDBT,,f,016.48,M,,F*3D
$SDDBT,,f,016.45,M,,F*30
$SDDBT,,f,016.40,M,,F*35
$SDDBT,,f,016.35,M,,F*37
$GPGGA,060309.00,3341.85924,S,15106.89810,E,2,07,1.3,156.71,M,20.4,M,3,0003*75
$GPVTG,013,T,000,M,000.0,N,000.0,K,D*24
$SDDBT,,f,016.32,M,,F*30
$SDDBT,,f,016.28,M,,F*3B
$SDDBT,,f,016.25,M,,F*36
$SDDBT,,f,016.22,M,,F*31
$SDDBT,,f,016.17,M,,F*37
$SDDBT,,f,016.17,M,,F*37
$GPGGA,060310.00,3341.85926,S,15106.89810,E,2,07,1.3,156.72,M,20.4,M,3,0003*7C
$GPVTG,013,T,000,M,000.0,N,000.0,K,D*24
DBS
$SDDBS,,f,7.62,M,,F*32
$SDDBS,,f,7.59,M,,F*3A
$SDDBS,,f,7.56,M,,F*35
$SDDBS,,f,7.53,M,,F*30
$SDDBS,,f,7.50,M,,F*33
$SDDBS,,f,7.47,M,,F*35
DBT
$SDDBT,,f,017.61,M,,F*37
$SDDBT,,f,017.68,M,,F*3E
$SDDBT,,f,017.73,M,,F*34
$SDDBT,,f,017.78,M,,F*3F
$SDDBT,,f,017.85,M,,F*3D
$SDDBT,,f,017.92,M,,F*3B
$SDDBT,,f,017.97,M,,F*3E
$SDDBT,,f,018.04,M,,F*3B
ATLAS DESO 25
DA00014.36 m
DB00014.36 m
*
DA00014.43 m
DB00014.43 m
*
DA00014.50 m
DB00014.50 m
*
69
CEEDUCER PRO™ User Manual V3.18.02
$GPGGA,020704.00,3341.85894619,S,15106.89836423,E,2,09,1.2,159.173,M,20.417,M,5.8
,0003*58
$GPVTG,48.70,T,,M,0.07,N,0.14,K,D*01
$GPGST,020704.00,0.33,0.35,0.19,16.30,0.34,0.20,0.65*5A
$GPZDA,020704.00,09,09,2010,00,00*64
$GPGGA,020705.00,3341.85894701,S,15106.89836436,E,2,09,1.2,159.184,M,20.417,M,6.2
,0003*54
$GPVTG,119.32,T,,M,0.03,N,0.06,K,D*35
$GPGST,020705.00,0.33,0.35,0.19,16.30,0.34,0.20,0.65*5B
$GPZDA,020705.00,09,09,2010,00,00*65
$GPGGA,020706.00,3341.85894892,S,15106.89836348,E,2,09,1.2,159.191,M,20.417,M,6.0
,0003*5A
$GPVTG,172.47,T,,M,0.11,N,0.21,K,D*3C
$GPGST,020706.00,0.33,0.35,0.19,16.30,0.34,0.20,0.65*58
$GPZDA,020706.00,09,09,2010,00,00*66
70
GGA + GST+ VTG + ZDA + DESO 25
Used for supplying position and dual frequency depth to HYPACK™. Use the GPS driver in HYPACK™
Hydrographic Software to make use of the real time tide function and Pulse Per Second (PPS) timing to
synchronise multiple computers. Use the DESO 25 driver on the same comport to receive dual frequency
depth simultaneously.
$GPGGA,020701.00,3341.85894426,S,15106.89836597,E,2,09,1.2,159.169,M,20.417,M,5.8
,0003*56
$GPVTG,35.70,T,,M,0.04,N,0.08,K,D*05
$GPGST,020701.00,0.33,0.35,0.19,16.29,0.34,0.20,0.65*57
$GPZDA,020701.00,09,09,2010,00,00*61
*
DA00016.06 m
DB00017.06 m
*
DA00016.07 m
DB00017.07 m
*
DA00016.08 m
DB00017.08 m
*
DA00016.09 m
DB00017.09 m
*
DA00016.10 m
DB00017.10 m
*
DA00016.11 m
DB00017.11 m
*
$GPGGA,020702.00,3341.85894473,S,15106.89836704,E,2,09,1.2,159.168,M,20.417,M,6.2
,0003*55
$GPVTG,72.34,T,,M,0.03,N,0.05,K,D*0C
$GPGST,020702.00,0.33,0.35,0.19,16.29,0.34,0.20,0.65*54
$GPZDA,020702.00,09,09,2010,00,00*62
*
DA00016.12 m
DB00017.12 m
*
DA00016.13 m
DB00017.13 m
*
DA00016.14 m
DB00017.14 m
*
DA00016.15 m
DB00017.15 m
*
DA00016.16 m
DB00017.16 m
*
DA00016.17 m
DB00017.17 m
*
$GPGGA,020703.00,3341.85894602,S,15106.89836571,E,2,09,1.2,159.169,M,20.417,M,6.0
,0003*53
$GPVTG,20.14,T,,M,0.15,N,0.28,K,D*01
$GPGST,020703.00,0.33,0.35,0.19,16.29,0.34,0.20,0.65*55
$GPZDA,020703.00,09,09,2010,00,00*63
71
CEEDUCER PRO™ User Manual V3.18.02
72
Appendix A – Hardware details
Physical
Dimensions (lid closed): 270mm(w) x 240mm(d) x 130mm(h)
Weight: 3.56kg (Crescent option), 3.60kg (Eclipse option)
Temperature range: 0-50°C.
Electrical
Running power requirements (NiMH System)
Input Voltage: 12–24V
Input Current @ 12V: 1A
73
CEEDUCER PRO™ User Manual V3.18.02
Connections
Serial Data/FIX
The Serial Data connector port on the CEEDUCER PRO™ is designed to mate with a 5-way LEMO 1B
series male plug (LEMO P/N: FGG1B305CLAD52). This connector contains RS232 output signals, a
short triggered fix signal, and accepts an RS232 input.
GPS/RTCM
The GPS/RTCM connector port on the CEEDUCER PRO™ is designed to mate with a 5-way LEMO 1B
series male plug (LEMO P/N: FGG1B305CLAD52). This connector accepts RS232 input signals, and
supplies RS232 output signals.
Heave/Tide
The Heave/Tide connector port on the CEEDUCER PRO™ is designed to mate with a 5-way LEMO 1B
series male plug (LEMO P/N: FGG1B305CLAD52). This connector accepts RS232 input signals.
Power
The Power connector port on a CEEDUCER PRO™ is designed to mate with a 3-way LEMO 1B series
male plug (LEMO P/N: FGG1B303CLAD)
74
Echosounder 1 + 2
The two Echosounder connector ports on the CEEDUCER PRO™ are each designed to mate with a 6-
way LEMO 2B series male plug (LEMO P/N: FGG2B306CLAD82) This connector accepts RS232 input
signals, and provides 12V power supply for driving echosounders.
GPS antenna
This is a standard TNC female bulkhead adapter with 5V DC power on the signal line, for an active GPS
antenna.
Ethernet
This is a standard RJ45 Ethernet socket, capable of Ethernet connections at 10baseT and 100baseT,
presented inside a waterproof screw shut housing.
Model options
CEEDUCER PRO™ – Lead Acid battery, A12 GPS.
Correction data capability: RTCM SC104 v2.2 differential remote message types 1,3,9
Ashtech DG14
Channels: 12
Correction data capability: RTCM SC104 v2.2 differential remote message types 1,3,9
75
CEEDUCER PRO™ User Manual V3.18.02
Hemisphere Crescent
Channels: 12
Hemisphere Eclipse
Channels: 24 (12 L1 channels, and 12 L2 channels)
SBAS capability: yes (not possible to use with RTK or OmniSTAR capability options)
Correction data capability RTK: RTCM SC104 V3.0 RTK, CMR+, ROX.
Channels: 2
76
Appendix B – Cable Details
Data/Fix Cable DCE
The cable to go from a CEEDUCER PRO™ to a computer should be terminated in a with a D9 female,
with pins configured in a DCE arrangement. Use 2.5m of 2 core CANARE L-2T2S cable with LEMO P/N:
FGG1B305CLAD52 on one end, and a D9 female on the other.
Power Cable
Use 2.5m of 4 core CANARE L-2T2S cable, with LEMO P/N: FGG1B303CLAD on one end, and the
other end terminated with tinned Red and Black 1.5A rated leads.
Echosounder Cable, HF
Single echosounder units come with a cable attached permanently. Cables are terminated with LEMO
P/N:FGG2B306CLAD82.
Echosounder Cable, LF
Single echosounder units come with a cable attached permanently. Cables are terminated with LEMO
P/N:FGG2B306CLAD82.
77
CEEDUCER PRO™ User Manual V3.18.02
WARNING: Dual Echosounder units manufactured prior to May 2008 do not conform to this wiring
colour scheme. Signal names and pin numbers on the C6LS are the same, but wiring colours are not.
Please Contact Bruttour for correct wiring diagram.
78
External RTCM cable, DTE
Use 2.5m of CANARE L-2T2S cable, with a D9 Male connector on one end, and a LEMO P/N:
FGG1B305CLAD52 on the other end.
Signal Name LEMO pin # Heave D9 Pin # Tide D9 Pin Cable wire
#
Tide in 3 2 BLUE
Heave in 2 2 WHITE
GND 5 5 5 Shield
GPS RF cable
Use 5m of RG58 cable, terminated at each end with TNC male connectors.
79
CEEDUCER PRO™ User Manual V3.18.02
Physical:
Transducer is supplied with 9m (29.5’) cable with LEMO 2B plug. Transducer mounts are available from
Bruttour International to allow for easy installation to most vessels. Cable from transducer should be
protected to avoid damage from debris in the water or rough surfaces along the path from transducer to
CEEDUCER PRO™.
80
200 kHz echosounder, Beam Angle 2.75°
Physical:
Transducer is supplied with 9m (29.5’) cable with LEMO 2B plug. Transducer mounts are available from
Bruttour International to allow for easy installation to most vessels. Cable from transducer should be
protected to avoid damage from debris in the water or rough surfaces along the path from transducer to
CEEDUCER PRO™.
See table on page 84 for footprint information for 2.75° beam angle
81
CEEDUCER PRO™ User Manual V3.18.02
Physical:
Transducer is supplied with 9m (29.5’) cable with LEMO 2B plug. Cable from transducer should be
protected to avoid damage from debris in the water or rough surfaces along the path from transducer to
CEEDUCER PRO™.
See table on page 84 for footprint information for 19° beam angle
82
Dual echosounder 200/30 kHz (8°/19°)
The CEEDUCER PRO™ can run with a 200kHz and 30kHz transducer operating simultaneously. A
urethane fairing kit is available to house a 200kHz 8° and 30kHz 19° transducer in a streamlined shoe.
Please contact Bruttour International for further information regarding this transducer option. The
stainless steel mount will fit onto pipe with 50mm (or 2”) outside diameter to allow for easy installation to
most vessels. Cables from the transducers should be protected to avoid damage from debris in the water
or rough surfaces along the path from transducer to CEEDUCER PRO™.
83
CEEDUCER PRO™ User Manual V3.18.02
84
Appendix D – Connection to a PC
RS232 serial
Connection to a PC via serial port is done via the CEEDUCER PRO™ Data/fix DCE cable, and
optionally, a standard RS232 extension cable.
Connection setups for a serial port connection on the PC are done at the application level for the
application you wish to use. The exact configuration steps are dependent on the application in use. The
port setting for the serial port in use must be 8 data bits, no parity, and one stop bit (often notated 8,N,1).
The baud rate setting on the computer must match the baud rate setting on the CEEDUCER PRO™.
This setting is found by pressing the MENU button, then selecting “Setup”, then “Comms”, then “RT O/P
Baud” in the menu system.
Bluetooth option
Connection via Bluetooth from a CEEDUCER PRO™ to a PC can be made via Bluetooth receivers,
provided the CEEDUCER PRO™ has the Bluetooth option installed (quick check – look for an SMA RF
connector on the right hand Side of the CEEDUCER PRO™, next to the Ethernet connector (see image
on page 13) Also, the PC must also have a Bluetooth adapter installed or connected.
When setup, the Bluetooth connection behaves similarly to a wired serial port connection.
From the CEEDUCER PRO™ MENU select “Setup” then “Comms”, and then “PC Comms Port”. Change
the RS232 interface selection to the Bluetooth option required.
For a PC to connect to the CEEDUCER PRO™, via Bluetooth, you must first ensure that your PC has a
Bluetooth adapter that is properly installed and running. (The details of this will need to be covered in
either your computers or your Bluetooth adapter’s instruction manual, as depending on the Bluetooth
adapter in use the setup process will vary. Please see your IT support staff, if you need help with this)
When you have a computer with Bluetooth installed and running, you need to go to “Control Panel/
Bluetooth Devices” and select the “Devices” Tab.
If the CEEDUCER PRO™ has not been connected to this computer before, there will be no entry for it
yet. If this is the case, select the “Add” button (having first ensured that your CEEDUCER PRO™ is
powered on, and the Bluetooth antenna is installed) and your computer will search for it. When the
CEEDUCER PRO™ shows up in the list of found devices, you need to select it, and click the “Next”
button. The computer will then attempt to link to the CEEDUCER PRO™ Bluetooth connection for the
first time, and will ask for a passkey. The default CEEDUCER PRO™ Bluetooth passkey is “1234”
From here, the CEEDUCER PRO™ Bluetooth module will be connected to the computer, and a virtual
serial port (for the radio link that’s replacing your serial cable) will be assigned. You can now connect to
and open this serial port using software, and receive real time data or downloads as you would over a
real cable.
NOTE: It is not advisable to allow your computer to go to sleep mode while connected to your
CEEDUCER PRO™ via Bluetooth. Depending on the brand and driver of your Bluetooth adapter, you
may have to remove the CEEDUCER PRO™ from your Bluetooth Devices list, reboot your computer and
re-make your Bluetooth connection to the CEEDUCER PRO™.
85
CEEDUCER PRO™ User Manual V3.18.02
Ethernet
Connection to a PC via Ethernet is done via a standard Ethernet crossover cable.
Setting up an Ethernet connection for either FTP download or real time UDP data requires the same
basic first steps of setting up the Ethernet connection.
NOTE: There may be several Local Area Connections. It is important to choose the LAN to which the
CEEDUCER PRO™ is to be connected.
Right-click on this icon and select “Properties” to edit the network port properties.
86
Select “Internet Protocol (TCP/IP)” and click the “Properties” button
87
CEEDUCER PRO™ User Manual V3.18.02
All other settings, e.g. default gateway and DNS settings can be left blank.
Click OK, on this dialog window, and then OK on the Local area connection properties window, to
confirm and enable the changes to the network connection.
NOTE: The IP address of the PC should NOT match the IP address of the CEEDUCER PRO™
88
Setup CEEDUCER PRO™ IP address
Turn on the CEEDUCER PRO™.
Select desired IP Address (we suggest using the default 192.168.0.1) – whatever number selected, it
should NOT match the IP address of the PC
NOTE: If the IP address of the CEEDUCER PRO™ is set to the same address as another device on the
network a connection will not be made. You may see an error message on your PC notifying you of a
conflicting IP address. If this message appears select a different IP address in the CEEDUCER PRO™.
89
CEEDUCER PRO™ User Manual V3.18.02
If you do not have an FTP client on your computer, Cute FTP can be downloaded from
www.globalscape.com and is available in both home and professional versions. (The FTP setup process
is identical for either version)
Firstly, ensure the CEEDUCER PRO™ and the PC are connected via Ethernet and configured to
communicate with each other, as described in Appendix D – Connection to a PC.
Start Cute FTP, then select the menu “File” “Connect” ”Connect”
90
Fill in the fields of the dialog box as shown
NOTE: the Host address must be set to the same number as defined in the CEEDUCER PRO™ IP
address setup.
NOTE: NO USER name or password is required & the login method is Anonymous
Click “Connect”
91
CEEDUCER PRO™ User Manual V3.18.02
If the connection is successful, the log window will show the following,
The directory listing will show what log files in the CEEDUCER PRO™ are available for download. They
may be selected and downloaded to any directory in the PC, as required.
92
Appendix F – Real time UDP into HYPACK™
CEEDUCER PRO™ and PC setup
The CEEDUCER PRO™ and PC should be configured as described in Appendix D – Connection to a PC
via Ethernet. Set the output format from the CEEDUCER PRO™ to GGA, VTG + ODOM (or GGA, VTG
for position only). The real time output baud rate setting of the CEEDUCER PRO™ is not used.
NOTE: A PPS message will not operate with the CEEDUCER PRO™ driver. The GPS driver must be
selected
NOTE: The PPS function will not operate via an UDP connection. If you wish to use PPS function from
the CEEDUCER PRO™ for computer timing (if this feature has been enabled) you must connect via a
“Data Output with PPS” LEMO cable to a serial port on the PC.
93
CEEDUCER PRO™ User Manual V3.18.02
$[--]GGA,[hhmmss.ss],[llll.ll],[a],[yyyyy.yy],[a],[q],[ns],[hdp],[alt],M,[sep],M,[age],[id]*[hh]<cr><lf>
Where
[hhmmss.ss] is the time in seconds past midnight, (UTC time), that the position fix was made.
[ns] is the number of satellites in use for the position fix (not just in view).
[hdp] is the Horizontal Dilution of Precision – which is a figure relating to the precision of the computer
position – a smaller number is better than a larger one.
[sep] is the separation between the geoid and the WGS84 reference ellipsoid.
[age] is the number of seconds since the last correction data came through, or a null field if correction is
not being used.
[id] is the ID number of the differential reference station generating differential data.
[hh] is an 8 bit exclusive OR checksum of the characters in the string between but excluding the $ and
the * character. The 8 bit value is broken down into two 4 bit nibbles that are expressed in Hexidecimal
notation (0-9,A-F).
$GPGGA,055919.00,3341.85947,S,15106.89778,E,2,07,1.3,158.14,M,20.4,M,3,0003*71
$GPGGA,055920.00,3341.85946,S,15106.89778,E,2,07,1.3,158.11,M,20.4,M,3,0003*7F
$GPGGA,055921.00,3341.85946,S,15106.89777,E,2,07,1.3,158.11,M,20.4,M,3,0003*71
$GPGGA,055922.00,3341.85944,S,15106.89776,E,2,07,1.3,158.09,M,20.4,M,3,0003*78
$GPGGA,055923.00,3341.85941,S,15106.89775,E,2,07,1.3,158.02,M,20.4,M,4,0003*73
$GPGGA,055924.00,3341.85938,S,15106.89775,E,2,07,1.3,157.99,M,20.4,M,4,0003*77
94
VTG heading data
The VTG message contains information relating to the course over ground, and the speed the GPS
receiver is travelling.
$[--]VTG,[cog,t],T,[cog,m],M,[sp-n],N,[sp-k],K,[a]*[hh]<cr><lf>
Where
[cog,t] is the course over ground (current direction) relative to true north.
[cog,m] is the course over ground (current direction) relative to magnetic north.
[a] is the positioning system mode indicator. A = autonomous, D = differential, E = estimated (dead
reckoning), M = manual input mode, S = Simulator mode, N = data not valid.
[hh] is an 8 bit exclusive OR checksum of the characters in the string between but excluding the $ and
the * character. The 8 bit value is broken down into two 4 bit nibbles that are expressed in Hexadecimal
notation (0-9,A-F).
$GPVTG,013,T,000,M,000.0,N,000.0,K,D*24
$GPVTG,013,T,000,M,000.0,N,000.0,K,D*24
$GPVTG,013,T,000,M,000.0,N,000.0,K,D*24
$GPVTG,013,T,000,M,000.0,N,000.0,K,D*24
$[--]ZDA,[hhmmss.ss],[dd],[mm],[yyyy],[lh],[lm]*[hh]<cr><lf>
Where
[hhmmss.ss] is the hours, minutes, and seconds(decimal) of the current fix in UTC time.
[lh] is the hour’s value of the offset between UTC and local time.
[hh] is an 8 bit exclusive OR checksum of the characters in the string between but excluding the $ and
the * character. The 8 bit value is broken down into two 4 bit nibbles that are expressed in Hexadecimal
notation (0-9,A-F).
$GPZDA,025504.00,23,07,2009,00,00*6D
$GPZDA,025505.00,23,07,2009,00,00*6C
$GPZDA,025506.00,23,07,2009,00,00*6F
95
CEEDUCER PRO™ User Manual V3.18.02
Depth data
NMEA DBT
This format with comma delimited variable length fields represents the distance from the echosounder
transducer face to the bottom of the water, in three separate formats. Although the CEEDUCER PRO™
only reads or writes the metres field, and ignores the other two formats.
“$SDDBT,”[DEPTH-FEET]”,f,”[DEPTH-METRES]”,m,”[DEPTH-FATHOMS]”,F*”[CHKSM]<CR><LF>
[CHKSM] – 8 bit checksum value for the entire string between “$” and “*”. Ignored.
$SDDBT,,f,7.62,M,,F*32
$SDDBT,,f,7.59,M,,F*3A
$SDDBT,,f,7.56,M,,F*35
$SDDBT,,f,7.53,M,,F*30
$SDDBT,,f,7.50,M,,F*33
$SDDBT,,f,7.47,M,,F*35
NMEA DBS
This format with comma delimited variable length fields represents the distance from the surface of the
water to the bottom of the water, in three separate formats.
“$SDDBS,”[DEPTH-FEET]”,f,”[DEPTH-METRES]”,m,”[DEPTH-FATHOMS]”,F*”[CHKSM]<CR><LF>
[CHKSM] – 8 bit checksum value for the entire string between “$” and “*”. Ignored.
$SDDBS,,f,7.62,M,,F*32
$SDDBS,,f,7.59,M,,F*3A
$SDDBS,,f,7.56,M,,F*35
$SDDBS,,f,7.53,M,,F*30
$SDDBS,,f,7.50,M,,F*33
$SDDBS,,f,7.47,M,,F*35
96
Odom Echotrac Dual Bottom Tracking
This format with fixed length fields represents the measured distance from the surface of the water to the
bottom of the water.
[f][units][error]”B”<sp>[DEPTH1]<sp>[DEPTH2]<CR>
[error] shows a depth error. 1 character. E = HF, O = LF, D = both, <sp> = no error. Ignored
[DEPTH1] and [DEPTH2] are 5 character space padded integers, representing HF and LF depths in cm
or feet.
et B 202 210
et B 202 212
et B 200 209
et B 200 209
et B 201 208
et B 201 209
NOTE: this message is ended with a single carriage return character, and no linefeed. On viewing this
real time data in a terminal window that is not automatically adding a linefeed, this will have the effect of
rewriting new messages on the same line over and over, instead of having them scroll up the screen as
shown in the example data given here.
et 201
et 200
et 202
et 203
et 201
et 201
NOTE: this message is ended with a single carriage return character, and no linefeed. On viewing this
real time data in a terminal window that is not automatically adding a linefeed, this will have the effect of
rewriting new messages on the same line over and over, instead of having them scroll up the screen as
shown in the example data given here.
97
CEEDUCER PRO™ User Manual V3.18.02
ATLAS DESO25
This is an Atlas proprietary format capable of transmitting dual depth values in a pair of data strings.
“DA”[Depth1]” m”<CR><LF>
“DB”[Depth2]” m”<CR><LF>
“*”<CR><LF>
Where:
[Depth1] is an 8 character fixed width zero padded field displaying depth of the first echosounder in the
system, in metres, to 2 decimal places.
[Depth2] is an 8 character fixed width zero padded field displaying depth of the second echosounder in
the system, in metres, to 2 decimal places.
DA00064.36 m
DB00064.86 m
*
DA00064.37 m
DB00064.87 m
*
DA00064.38 m
DB00064.88 m
*
Tide data
TM
CEE HydroSystems CEETIDE format 2 – SHORT ASCII
The CEEDUCER PRO™ will accept tide data to correct depths in real time. This data is supplied to the
CEETIDE™ via the TIDE INPUT cable.
[HH]”:”[MM]”:”[SS]<SP>[TIDE]<CR><LF>
[TIDE] is a 6 digit decimal number that can be positive or negative, representing the tide height above the
reference datum in metres. It has a resolution of cm.
15:02:35 -0.82
15:02:40 -0.82
15:02:45 -0.82
15:02:50 -0.82
98
Heave data
The CEEDUCER PRO™ accepts heave data in TSS1 format. This data may contain acceleration, pitch,
and roll information too however the CEEDUCER PRO™ does not use this other data. This data is
supplied the CEEDUCER PRO™ via the HEAVE INPUT cable. The CEEDUCER PRO™ will only
recognise a “settled” heave status message.
“:”[xx][aaaa]<sp>[shhhh][Q]<sp>[srrrr]<sp>[spppp]<CR><LF>
[Q] – Heave status indicator. 1 character. “u” = not settled, “U” =settled.
Diff data
Differential (Diff) correction data is a common name for real time satellite position correction information.
In a L1 band only GPS this data can correct the system to around 1m absolute accuracy. The usual
format for this data is defined in the RTCM SC104 V2 standard. This data is supplied the CEEDUCER
PRO™ via the Ext RTCM INPUT cable or Bluetooth (if fitted).
This is a binary data format, and makes no sense to display in ASCII character form.
RTK data
nd
RTK correction data is a common name for real time 2 receiver satellite measurements at a known
point, that can be used by the roving receiver to correct the system to around 1cm absolute accuracy.
This kind of correction data can only be used by advanced receivers such as the Hemisphere Eclipse,
with the RTK option enabled. Data formats for RTK correction messages can be to the RTCM SC104 V3
specification, the CMR+ format, and the Hemisphere proprietary ROX format. This data is supplied the
CEEDUCER PRO™ via the Ext RTCM INPUT cable or Bluetooth (if fitted).
These are binary data formats, and make no sense to display in ASCII character form.
99
CEEDUCER PRO™ User Manual V3.18.02
NOTE: The CEEDUCER PRO™ will not start logging if the ERROR LED is lit notifying the operator of an
error. All components must be communicating correctly to start logging. If an ERROR occurs with GPS
and/or echosounder information during logging the CEEDUCER PRO™ will pause logging automatically.
Once the ERROR condition is resolved the CEEDUCER PRO™ will resume logging to the same file. If
an ERROR condition occurs regarding any other component while the CEEDUCER PRO™ is logging
(e.g. “NO DIFF”, “HEAVE COMMS ERROR” etc.) the unit will continue to log data until the logging is
manually paused/stopped.
GPS
Message What to do
“NO GPS Ensure GPS antenna is in clear view to the sky, obstructions such as the
POSITION” cabin of a boat can block the GPS signal resulting in no position.
(internal GPS Check TNC connection on both antenna and CEEDUCER PRO™, check
option) antenna cable for damage (for internal GPS option).
Check CEEDUCER PRO™ GPS mode of operation is set correctly to internal
GPS (page 29) – GPS LED should be flashing
If the CEEDUCER PRO™ has moved a long way since the last use it will take
longer to establish a position. Resetting the internal GPS may allow for a
quicker start up (page 29).
100
RTCM
“NO DIFF” Is there marine beacon coverage in your area
Internal – Marine Ensure diff mode is set to marine beacon (page 30)
Beacon (if fitted)
If signal is weak “AUTO” frequency mode may not locate signal. Change to
(available in manual mode and set frequency to required value. (page 33)
Crescent, A12,
Ensure antenna is suitable for marine beacon (e.g. HEMISPHERE A30)
DG14)
“NO DIFF” SBAS is not available in all areas. Check availability in your area
Internal – SBAS Ensure internal Diff option is set to SBAS option (page 30)
“NO DIFF” Set the internal Diff option to OmniSTAR (page 30)
Internal – Check subscription expiry date (page 36)
OmniSTAR
If GPS has been reset a subscription will have to be reactivated. Contact
(Eclipse only) Bruttour International for more information
Signal from OmniSTAR may be obstructed by terrain in your area. Check
details of signal source for suitability (e.g. narrow gorge)
No RTK , only Check number satellites in range (SVS number) displayed, RTK is difficult to
DGPS when set to achieve with low number of satellites.
Eclipse RTK option
101
CEEDUCER PRO™ User Manual V3.18.02
Echosounders
“NO E/S” Check connection on CEEDUCER PRO™. Ensure plugs are aligned correctly
and pushed all the way into the socket
Internal
Echosounder Check for damage to transducer or transducer cable
Selection
“NO E/S” Check format of incoming data is accepted by the CEEDUCER PRO™
(link)
External
Echosounder Check baud rate is set to match source (link)
Selection
If A E/S LED is not flashing check cable connection or try null modem
Check correct port on CEEDUCER PRO™ is being used
Check correct cable is being used
Constant zero Check the face of the transducer is not obstructed by debris or weed
depths when boat
Check that there are no air bubbles around the transducer. A Draft at least
is not moving
50cm is recommended.
Other transducers can reduce data quality. Check for other transducers
operating on the same boat or on boats nearby. Fish finder and chart plotter
systems can cause errors in depths to occur
NOTE: Zero depths are not identified with an ERROR message. Regularly
view the depth data to ensure quality of information being recorded.
Constant zero Transducer is possibly getting air passing the face. Relocate transducer to
depths when boat another position or increase the draft.
is moving
Vessel speed may be too fast for mount position. Reducer vessel speed
Check for other transducers operating on the same boat or on boats nearby.
Fish finder and chart plotter systems can cause errors in depths to occur
NOTE: Zero depths are not identified with an ERROR message. Regularly
view the depth data to ensure quality of information being recorded.
102
Interface
“HEAVE COMMS Heave data is not being received by CEEDUCER PRO™.
ERROR”
Check cable connections and baud rates
Ensure correct format is being used (link)
Check data contains a settle heave status (capital letter next to heave value)
Check correct port on CEEDUCER PRO™ is being used
Check correct cable is being used
No Real Time Data Select required output format. Check DATA OUT LED is flashing
Check cable connection and baud rate
Check correct port on CEEDUCER PRO™ is being used
Check correct cable is being used
103
CEEDUCER PRO™ User Manual V3.18.02
OmniSTAR HP Frequencies
The CEEDUCER PRO™ can be set from automatic search mode to fixed frequency and baud rate to
acquire an OmniSTAR HP correction signal. Below is a list of regions with frequency and baud rate
settings covering this area.
NOTE: A valid OmniSTAR subscription is required to receive the correction messages. Contact CEE
HydroSystems™ for details on OmniSTAR subscription options
104
Australian AMSA Beacon Frequencies
105
CEEDUCER PRO™ User Manual V3.18.02
106
Station: Gladstone, Queensland
Status: On-air
Ref Stn 1 antenna 24° 02' 12.544" S 151° 21'
location: 31.570" E
Ref Stn 2 antenna 24° 02' 12.543" S 151° 21'
location: 31.460" E
IALA Ref Stn ID #: 6
IALA Tx Stn ID #: 706
Frequency: 313 kHz
Baud Rate: 200 bps
RTCM Messages Used: Types 3, 5, 7, 9, 16
Radiated Power: 320 watts
107
CEEDUCER PRO™ User Manual V3.18.02
108
Station: Weipa, Queensland
Status: On-air
Ref Stn 1 antenna 12° 39' 12.658" S 141° 51'
location: 36.631" E
Ref Stn 2 antenna 12° 39' 12.669" S 141° 51'
location: 36.725" E
IALA Ref Stn ID #: 9
IALA Tx Stn ID #: 709
Frequency: 316 kHz
Baud Rate: 200 bps
RTCM Messages Used: Types 3, 5, 7, 9, 16
Radiated Power: 120 watts
109
CEEDUCER PRO™ User Manual V3.18.02
110
Index
A Echosounder Source ...................................... 37
Equipment care ............................................... 63
About ............................................................... 49
Ethernet .......................................................... 75
Absolute maximum ratings ..............................73
Event Number Increment ................................ 60
Ashtech A12 ....................................................75
External baud .................................................. 39
Ashtech DG14 .................................................75
External GPS Baud rate.................................. 29
ATLAS DESO 25 .............................................69
External Power input ....................................... 16
ATLAS DESO25 ..............................................98
External RTCM baud rate ............................... 33
B External Selection ........................................... 38
Battery technology ............................................. 9 G
Beacon Frequency (Crescent, A12, DG14 only)
Geodetic Setup – Spheroid shift ..................... 52
..................................................................... 34
Geodetic Setup – Transverse Mercator
Beacon Mode (Crescent, A12, DG14 only) .....33
projections ................................................... 53
Bluetooth ............................................................ 9
GGA + GST+ VTG + ZDA ............................... 70
Buttons ............................................................. 11
GGA + GST+ VTG + ZDA + DESO 25 ........... 71
C GGA + VTG + DBS ......................................... 67
Clear Log .........................................................59 GGA + VTG + DBT ......................................... 69
Close File .........................................................58 GGA + VTG + ODOM (Dual Echosounder) .... 68
Connecting the devices ...................................89 GGA + VTG + ODOM (Single Echosounder) . 68
Connections – Left Hand Side .........................11 GGA position data........................................... 94
Connections – Right hand Side .......................12 GPS – correction data..................................... 64
Control Unit Location .......................................18 GPS – NMEA 0183 format strings .................. 64
Create New File ...............................................58 GPS antenna .................................................. 75
Critical Settings ................................................21 GPS Antenna Location ................................... 19
GPS correction data formats .......................... 99
D GPS options ...................................................... 8
Data Integration and processing......................15 GPS positioning input and GPS correction
Data logging and downloading ..................15, 58 settings .................................................. 13, 29
DBS ................................................................. 69 GPS Source .................................................... 29
DBT .................................................................. 69 GPS Time Correction ...................................... 47
Depth data .......................................................96 GPS/RTCM ..................................................... 74
Diff data ...........................................................99 H
Diff source selection ........................................31
Display .......................................................11, 15 Heave baud ..................................................... 44
Display settings................................................22 Heave data ................................................ 66, 99
Download Files ................................................59 Heave Enable ................................................. 43
Download raw log files .....................................24 Heave/Tide ...................................................... 74
Hemisphere Crescent ..................................... 76
E Hemisphere Eclipse ........................................ 76
Echosounder 1 + 2 ..........................................75 HF E/S Draft .................................................... 40
Echosounder Bar Check ..................................61 HF E/S Offset .................................................. 41
Echosounder Data ...........................................65 I
Echosounder Depth Adjustment - Heave Input
(MRU) ...........................................................43 Index Offset..................................................... 41
Echosounder Depth Adjustment – Heave Input Internal GPS Reset ......................................... 30
(MRU) ...........................................................14 Internal Selection ............................................ 38
Echosounder Height Reference - Tide Input ...44 IP Address ...................................................... 57
Echosounder input and sound velocity
correction .....................................................14
111
CEEDUCER PRO™ User Manual V3.18.02
L P
Lead Acid Battery charging requirements .......73 PC Comms Port .............................................. 54
Lead Acid battery System ................................16 PC communication settings ............................ 22
LEDs ................................................................ 10 Position Format ............................................... 50
LF E/S Draft .....................................................41 Power .............................................................. 74
LF E/S Offset ...................................................42 Processing with CEEDATA ............................. 24
Log File marker messages (Manual Processing with HYPACK™ ........................... 24
Events/Fixes) ...............................................16 Profile Range .................................................. 50
Log File operations ..........................................16
R
M
Real time Data output ............................... 15, 54
Making Connections ........................................19 RT O/P Baud ................................................... 55
Manual Velocity ...............................................40 RTK Antenna Height (Eclipse RTK only) ........ 30
Max Depth Enable ...........................................42 RTK data ......................................................... 99
Max Depth Value .............................................43 Running power requirements (Lead-Acid
Mode Selection ................................................45 System) ....................................................... 73
Running power requirements (NiMH System) 73
N
S
Next Event Number .........................................60
NiMH Battery charging requirements ..............73 Screen Saver .................................................. 51
NiMH battery system .......................................16 Serial Data/FIX ................................................ 74
NMEA 0183 format GPS data .........................94 Setup CEEDUCER PRO™ IP address........... 89
NMEA DBS ................................................66, 96 Setup PC Network card and configure TCP/IP86
NMEA DBT ......................................................96 Speed Units .................................................... 51
NMEA GGA .....................................................67 System ...................................................... 13, 45
NMEA GGA +VTG ...........................................67 System reset ................................................... 48
O T
ODOM (DUAL echosounders) .........................68 Telemetry Location ......................................... 19
ODOM (SINGLE echosounder) .......................68 Tide Baud ........................................................ 45
Odom Echotrac Dual Bottom Tracking ............97 Tide data ................................................... 66, 98
Odom Echotrac Single Bottom Tracking .........97 Tide Enable ..................................................... 44
Odom Echotrac Single or Dual Bottom Tracking Transducer Height Reference – Tide Input..... 15
..................................................................... 65 Transducer Location ....................................... 18
OmniSTAR Baud (Eclipse and Eclipse RTK Transducers ...................................................... 9
only) ............................................................. 36 Turning the CEEDUCER PRO™ on and off ... 21
OmniSTAR Details (Eclipse and Eclipse RTK
U
only) ............................................................. 36
OmniSTAR Freq (Eclipse and Eclipse RTK only) UTC Offset ...................................................... 47
..................................................................... 35 V
OmniSTAR HP Mode (Eclipse and Eclipse RTK
only) ............................................................. 35 Velocity Mode ................................................. 39
Operational Mode ............................................13 VTG heading data ........................................... 95
Output Format..................................................55 Z
ZDA Timing data ............................................. 95
112
CEE HydroSystems
Unit 1, 12 Cecil Rd,
Hornsby (Sydney)
NSW 2077
Australia
t: +61 (0) 2 9987 1581
f: +61 (0) 2 9987 1584
e: [email protected]
www.ceehydrosystems.com
www.ceehydrosystems.com