RLN F01U304009 11 B426 enUS BDL
RLN F01U304009 11 B426 enUS BDL
B426
en Release Notes
Conettix Ethernet Communication Module Table of contents | en 3
Table of contents
1 Introduction 4
1.1 Requirements 4
1.2 About documentation 5
2 Firmware version 3.11 6
2.1 What's new 6
2.1.1 Support for updated B426 certificates 6
3 Firmware version 3.10 7
4 Firmware version 3.09 8
4.1 What's new 8
4.1.1 California Security of Connected Devices Act 8
5 Firmware version 3.08 9
5.1 What's fixed 9
5.1.1 Updates to the bootloader 9
5.1.2 Updates to TCP keep alive 9
5.1.3 Updates to the web server 9
6 Firmware version 3.06 10
6.1 What's new 10
6.1.1 Incoming RPS connections 10
6.1.2 Secure connections using TLS v1.1 and v1.2 now supported 10
7 Firmware version 3.05 11
7.1 What's new 11
7.1.1 Remote Connect Service support 11
7.2 Known issues 11
7.2.1 Network Module Trouble with 2 modules 11
7.2.2 IP address error on keypads 11
8 Firmware version 3.04.001 12
8.1 What's new 12
8.1.1 Configuration using option bus control panels 12
8.1.2 SIA DC09 event reporting support for AMAX control panels 12
8.2 Corrections 12
8.2.1 Configuration pages 12
8.3 Known issues 12
8.3.1 Network Module Trouble with 2 modules 12
8.3.2 IP address error on keypads 12
9 Revision history 13
9.1 Version 3.03.009 firmware 13
9.1.1 Security protocol support 13
9.1.2 TCP connection timeouts 13
9.2 Version 3.03.007 firmware 13
9.2.1 High traffic network enhancements 13
9.3 Version 3.03 firmware 13
9.3.1 Solution 2000/3000 control panel support 13
9.3.2 Email notifications 13
9.3.3 Increased IPv6 compatibility 13
9.3.4 Event reporting using CSV-IP protocol 14
9.4 Version 3.02 firmware 14
9.5 Version 3.01 firmware 14
1 Introduction
These Release Notes are for the B426 with firmware version B426_3.11.
Notice!
i Firmware version B426_3.11 is exclusively for the B426, B426-CN and B429-CN only. Do not
install this firmware version on the B426-M.
1.1 Requirements
Hardware identification for B426 modules
Notice!
Firmware v3.02 and higher require the new module hardware to operate. Modules with v3.01
firmware cannot update to this firmware version.
To determine a B426 hardware version, do one of the following:
– Compare the hardware to the diagram below. On the v3.01 hardware, the pins on the
tamper switch connector align with the pins on one interconnect wiring connector. On
the new hardware, the pins do not align.
TMPR
TMPR
R
R
PWR
PWR
v3.01 v3.02+
– Connect to the module using the web-based configuration and view the firmware version
on the Device Information (home) page.
Compatibility
Solution 2000/3000*
*The B426-M is recommended for AMAX and Solution Series
control panels.
Notice!
i Only applicable when connected to a Bosch B Series, or G Series control panel with firmware
version 3.07 or higher.
6.1.2 Secure connections using TLS v1.1 and v1.2 now supported
The firmware now supports secure connections, including personal notification email servers,
using TLS v1.0 (strong ciphers only), v1.1, and v1.2. In previous versions of the firmware,
control panel TLS connections required TLS v1.0 support.
Notice!
8.1.2 SIA DC09 event reporting support for AMAX control panels
AMAX control panels now support SIA DC09 event reporting.
8.2 Corrections
This section examines the corrections made in this firmware version.
9 Revision history
This section examines the notable features of previous revisions of this firmware.
Notice!
i Firmware v3.02 and higher require the new module hardware to operate. Modules with v3.01
firmware cannot update to newer (higher) firmware version. Refer to Requirements, page 4.
202111011315