V.1 Uttar Pradesh Iti Master Layout For Prefab Infrastructure - Option 1
V.1 Uttar Pradesh Iti Master Layout For Prefab Infrastructure - Option 1
Rajnikant Upadhyay
Mobile # 977 141 7020
1 © Copyright 2022 Tata Technologies. All rights reserved. All other trademarks are trademarks of their respective owners.
Classification: Public
Workshop
Buildup Area : Size 161.5 X 63.5 (Ft.)
2 © Copyright 2022 Tata Technologies. All rights reserved. All other trademarks are trademarks of their respective owners.
Classification: Public
Note: The layout for the Technology lab is prepared considering the VSAT studio as part of layout, It is applicable at location where the VSAT studio is provided, Other wise the
space can
© Copyright 2022be used asAll an
Tata Technologies. rights extra classroom
reserved. All to
other trademarks are which
trademarks the
of their furniture
respective owners. and other equipment required for classroom to be provided by the ITI.
Classification: Public
RCC Floor Requirements - Whole Floor (161.5 X 63.5 sq. Ft) RCC 6 inches except the Car Lift area as marked
requires 12 Inches of RCC.
RCC Floor Requirements - Note : 12” RCC for Car Lift in Machine 8 Area only (Increase the depth)
Top surface area will be plain.
7’
2’ A
TYP
18.5’
© Copyright 2022 Tata Technologies. All rights reserved. All other trademarks are trademarks of their respective owners.
Classification: Public
12’
12’
1 3ɸ - 32A MCB
MACHINE 3 CNC 1 Single Ph,6+16A Combined (2No’s for each location)
3ɸ 32A MCB (Dia 10sq mm multi core 1 1ɸ - 10A MCB
wiring) 1 3ɸ - 63A MCB
MACHINE 4 VMC
1 Single Ph,6+16A Combined (2No’s for each location)
3ɸ 63A MCB (Dia 10sq mm multi core
wiring) MACHINE 5 PAINT BOOTH 2 3ɸ - 32A MCB
Electric vehicle charging socket – 16A MACHINE 8 AUTO MRO 12 Single Ph,6+16A Combined (2No’s for each location)
Industrial Socket
MACHINE 9 AVEVA 2 3ɸ - 32A MCB
1ɸ 10A MCB (Dia 10sq mm multi core
wiring) MACHINE 10 VFD 1 3ɸ - 63A MCB
© Copyright 2022 Tata Technologies. All rights reserved. All other trademarks are trademarks of their respective owners.
Classification: Public
2.8KVA 3KVA 12.5 KVA 12.5KVA 3KVA 34KVA 2KVA 2.8KVA 2KVA
Technology LAB
10KVA
© Copyright 2022 Tata Technologies. All rights reserved. All other trademarks are trademarks of their respective owners. 25KVA
Classification: Public
8’ 5’ 5’ 5’ 5’ 5’
Following Items to be provided by ITI in Technology Lab area
• False Ceiling
4’
• Vitrified Tiling
• Power Supply 230 V AC, 50 HZ with electrical wiring through
14’ trenching connected up to the points on tables as shown in layout
• Ethernet Wiring connected to Lan Port as shown in layout
• 230V AC, 6/16A combined Plug Socket - 4 Nos at each table.
• Split AC 2 Ton with wiring & Switching - 2 nos. in Each Room
6’
• Indoor Wall Painting in the room as per standard of the Institution
• UPS and Network Switch in UPS & Server Room
• Instructor Table & Chairs, White Board and Curtains in all
LEGENDS Classrooms.
• Lighting and its switches, wiring.
1 Ph ,230V AC 50HZ, 6/16A • CCTV Cameras
combined (2 Nos for each
location)
OPTIONAL :
• Projectors and Screen with sound output for classrooms.
Lan port
Note : Floor Trenching or conduit can be used for routing wires and networking cables. Separate conduits to be used for electrical and networking cables.
© Copyright 2022 Tata Technologies. All rights reserved. All other trademarks are trademarks of their respective owners.
Classification: Public
Note : Floor Trenching or conduit can be used for routing wires and networking cables. Separate conduits to be used for electrical and networking cables.
© Copyright 2022 Tata Technologies. All rights reserved. All other trademarks are trademarks of their respective owners.
Classification: Public
LT Panel
© Copyright 2022 Tata Technologies. All rights reserved. All other trademarks are trademarks of their respective owners.
Classification: Public
1st stage of tech lab readiness required. 2nd stage of tech lab readiness required.
• All electrical cables and networking as per layout. Before need • 2 days furniture the working progress first day they will all
to be finished the all-civil work should completed. furniture fixed it. Next day the site electrical and networking
• All electrical and networking cables are in ground or in wall persons required.
concealed. • All electrical 6/16 switches fixed it in table simultaneously. As
• Before furniture installation start all electrical networking and well networking 6J45 Lan Port same prosses
civil work completed. (Kind of Fans, Led’s, AC and networking &
electrical cables routing)
6/16 Switches
In-progress
© Copyright 2022 Tata Technologies. All rights reserved. All other trademarks are trademarks of their respective owners.
and Lan port
Classification: Public
Studio Details:
Dimensions : Height – 4ft , Length – 24.20 ft, Width – 12.15 ft.
Requirements:
• We recommend RCC / Concrete roof for sound proofing.
• 10 ft brick wall is needed for studio and Moderator room
• Need brick wall partition in-between control room and live room.
• Need DGU sandwich glass window (Size – width 6ft and height 4ft)
middle of the partition.
• Need sandwich glass door (Size – width 3ft and Height 7ft) left side
of the partition.
• The live room should be soundproof and with good acoustic.
• Green screen for live room.
• Need movable light track in the live room (Size – 12ft*12ft)
• Need electrical points as per the diagram.
• We recommend carpet flooring.
• Need live room table, control room table and server rack.
• Need Furniture (live room table, control room table, server rack and
Chairs)
© Copyright 2022 Tata Technologies. All rights reserved. All other trademarks are trademarks of their respective owners.
Classification: Public
© Copyright 2022 Tata Technologies. All rights reserved. All other trademarks are trademarks of their respective owners.
Classification: Public
At VSAT classroom, a platform of size 6’ x 5’ to be provided to fix the VSAT antenna, (base size is 3”x3”) with
approaching staircase on wall outside the VSAT classroom window.
© Copyright 2022 Tata Technologies. All rights reserved. All other trademarks are trademarks of their respective owners.
Classification: Public
Electrical Routing
Tray
Electrical tray routing for workshop surrounding wall should be like this.
The surrounding area is required for placing the posters as shown.
© Copyright 2022 Tata Technologies. All rights reserved. All other trademarks are trademarks of their respective owners.
Classification: Public
• At the time of construction there should be 4” dia. Pipe insert in the wall to put PVC T-pipe so that exhaust pipes insert wall area
between 3 and 4 pillars center and from ground 8’’
• The straight pipe approx. 2’ long should be brought outside the wall so that the smoke after laser operation can go outside workshop.
• Material required
• 4’’ T-Pipe and 4’’ PVC pipe
© Copyright 2022 Tata Technologies. All rights reserved. All other trademarks are trademarks of their respective owners.
Classification: Public
To prevent personnel injury due to any abnormal current surges which may
result from electrical malfunction, proper earthing has to be done.
Earthing Requirements
• It is recommended to use copper wire/strip for earthing connection as it has
high conductance and is also anti-corrosive.
• Earthing wire should be insulated copper wire (10 sq.mm).
• Earthing should be isolated from the earthing of electric discharging machine,
electrical welders and punch presses etc… Earth pits
• Ground resistance shall be below 100 ohms and earth neutral voltage should Machine #
Required
always be less than 2Vac.
• Personal injury malfunctioning of machine. Proper earthing also safeguards the Robotics Cell 2
operator. VMC 1
• Machine should be earthed independently to prevent the machine from
malfunctioning due to leakage current/electrical noise CNC 1
Laser Cutter 1
© Copyright 2022 Tata Technologies. All rights reserved. All other trademarks are trademarks of their respective owners.
Classification: Public
© Copyright 2022 Tata Technologies. All rights reserved. All other trademarks are trademarks of their respective owners.
Classification: Public
Specification/
Machine Electrical Load Location Qty Remarks
Rating
General Purpose Four 6/16Amp combined plug socket (2 Nos for
Machines. 230 V AC , 1Ph, On the Back Wall at each location) Tentative location shown in earlier
1 6
Typical 5/15A 3Ft from Ground slide With one 16A industrial socket for EV
Inductive load charging &one 63A MCB
Machine 230V AC, 1 Ph, On the Back Wall at 6/16 Amp combined plug socket(2 Nos for each location)
2 1
Inductive Load 5/15A 3Ft from Ground . Tentative location shown in earlier slide.
Machine 440V AC, 3 Ph, On the Back Wall at
3 1 32A MCB For machine
inductive load 32A 3Ft from Ground
Machine inductive 440V AC, 3 Ph, On the Back Wall at 3Ft One 32A MCB for machine and one 32A MCB for
4 2
load 32A from Ground compressor
Machine 440V AC, 3 Ph, On the Back Wall at One 32A MCB for machine and one 32A MCB
5 2
inductive load 32A 3Ft from Ground for compressor
Between section 5
Machine 440V AC, 3 Ph, & section6 (3Ft
6 2 Two 32A MCB for machines
inductive load 32A/63A from Ground on
wall)
Provide 16+6 Amp combined plug socket(2 Nos for
Equipment 230V AC, 1 Ph, On the Back Wall at
7 3 each location) . Tentative location shown in earlier
inductive load 5/15A 3Ft from Ground
slide
© Copyright 2022 Tata Technologies. All rights reserved. All other trademarks are trademarks of their respective owners.
Classification: Public
Specification/
Machine Electrical Load Location Qty Remarks
Rating
© Copyright 2022 Tata Technologies. All rights reserved. All other trademarks are trademarks of their respective owners.
Classification: Public
Specification/
Machine Electrical Load Location Qty Remarks
Rating
Refer the color coding for 3Ph.
4C X 10 Sq. mm
Common Cable for heavy machines Concealed in the Length: Running length up to machine
power cable -
Requirement 440V AC, 3 Ph, 32A/63A wall from
(copper)
DB.
Earthing cable for heavy 1C X 10 Sq. mm Refer the color coding
Common Earth pit to
machines 440V AC, 3 Ph, earthing cable - for 3Ph Length: Approx.
Requirement machine
32A/63A (copper) 15 ft.
High Speed 3 On the Back Wall Provide 16+6 Amp combined plug
Common Blade Speed: at 10Ft from - socket. Tentative location shown in
Requirement Exhaust fan Inductive Load
1350 rpm Ground earlier slide
Common Equipped with fine IR LEDs for clearer
IR Range of 125 ft At the entrance -
Requirement Surveillance camera night vision
Refer the color coding for 3Ph.
4C X 10 Sq. mm
Cable for heavy machines Concealed in the Length: Running length up to machine
Common power cable -
440V AC, 3 Ph, 32A/63A wall from
Requirement (copper)
DB.
Earthing cable for heavy 1C X 10 Sq. mm Refer the color coding
Common Earth pit to
machines 440V AC, 3 Ph, earthing cable - for 3Ph Length: Approx.
Requirement machine
32A/63A (copper) 15 ft.
© Copyright 2022 Tata Technologies. All rights reserved. All other trademarks are trademarks of their respective owners.
Classification: Public
CENTER OF EXCELLENCE
Classification: Public
/TataTechnologies
@tatatechnologies
/TataTech_News
/TataTechnologies
/TataTechnologies
tatatechnologies.com
© Copyright 2022 Tata Technologies. All rights reserved. All other trademarks are trademarks of their respective owners.