0% found this document useful (0 votes)
25 views

Modbus en 1 20

This document contains a summary of register addresses and data types for a Modbus DP 1 VISU 20 device. It includes register addresses ranging from 8193 to 8352 that contain data such as part numbers, serial numbers, sensor values, status codes, error counts, run times and more. The data is primarily 16-bit unsigned integers but also includes 32-bit unsigned integers and 16-bit signed integers for values like temperatures.

Uploaded by

bnx5dkq786
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
25 views

Modbus en 1 20

This document contains a summary of register addresses and data types for a Modbus DP 1 VISU 20 device. It includes register addresses ranging from 8193 to 8352 that contain data such as part numbers, serial numbers, sensor values, status codes, error counts, run times and more. The data is primarily 16-bit unsigned integers but also includes 32-bit unsigned integers and 16-bit signed integers for values like temperatures.

Uploaded by

bnx5dkq786
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

Modbus DP 1 VISU 20

Start End type description

8193 8193 u 16bit High (12bit): part number; Low (4bit):reserviert


---
HHHH HHHH HHHH LLLL

8194 8195 u 32bit Serial number

8196 8196 u 16bit motor sensor ohmic value


1-65535Ω, 0 = not present

8198 8198 u 16bit error Messages


Bit 0: 0 = no error , 1 = at least one error is current appending

8199 8199 u 16bit status messages


Bit 0 - Engine status: 0 = Motor stands still; 1 = motor running

8202 8202 s 16bit motor temperature value


±327,00 °C (Wert/100)

8206 8206 u 16bit High (8bit): Major Software Revision Number


Low (8bit): Minor Software Revision Number
Arrangement: HHHH HHHH LLLL LLLL

8207 8207 u 16bit Data Matrix Function Description


0 = Engineering Sample
1.9 = variant ascending

8210 8210 u 16bit Variants to Articles Main Number


S = number of transferred value
0-9999
P-number = (transmitted value) - 10000
10000-19999

8211 8211 u 16bit voltage key


22=DualVoltage 115-230VAC
31=24VAC
13=24VDC

8212 8213 u 32bit Total error shutdowns


Arrangement: LLLL LLLL LLLL LLLL HHHH HHHH HHHH HHHH
0-327675

8214 8215 u 32bit Total operating shutdowns


Arrangement: LLLL LLLL LLLL LLLL HHHH HHHH HHHH HHHH
0-327675

8216 8216 u 16bit Current hour period in seconds (internal time)


0…3599 seconds

8223 8223 u 16bit average frequency (all 3 phases)


0 = not assigned
1 = frequency 0 Hz
2 = wrong phase sequence
3 ... 65535 motor frequency in Hz

8228 8228 u 8bit Number of hours of the current day (internal time)
0-23h

Modbus DP 1 VISU 20 25. Sep. 18 1 / 10


Modbus DP 1 VISU 20

Start End type description

8230 8230 u 8bit Total number of starts of the current day (internal time)
0-255

8232 8232 u 8bit Total number of starts of the last day (current day - 1 day, internal time)
0-255

8233 8233 u 8bit Total number of the starts of the penultimate day (current day - 2 days, internal time)
0-255

8234 8234 u 8bit Total number of starts of the third day (current day - 3 days, internal time)
0-255

8235 8235 u 8bit Total number of starts of the fourth day (current day - 4 days, internal time)
0-255

8236 8236 u 8bit Total number of starts of the fifth last day (current day - 5 days, internal time)
0-255

8237 8237 u 8bit Total number of starts of the sixth day (current day - 6 days, internal time)
0-255

8240 8240 u 8bit Switching cycles per hour - current hour


0-255

8241 8241 u 8bit Switching cycles per hour - current day


0-255

8242 8242 u 8bit Maximum of the switching cycles per hour of the last day (current day - 1 day, internal
time)
0-255

8243 8243 u 8bit max. Switching cycles per hour - 48 hours ago
0-255

8244 8244 u 8bit max. Switching cycles per hour - 72 hours ago
0-255

8245 8245 u 8bit max. Switching cycles per hour - 96 hours ago
0-255

8246 8246 u 8bit max. Switching cycles per hour - 120 hours ago
0-255

8247 8247 u 8bit Maximum of the switching cycles per hour of the sixth last day (current day - 6 days,
internal time)
0-255

Modbus DP 1 VISU 20 25. Sep. 18 2 / 10


Modbus DP 1 VISU 20

Start End type description

8248 8248 u 16bit Module state motor temperature monitoring


High Byte: actual status according error list
Low Byte: modul status Bit coded
Bit 0 = Active
Bit 1 = Warning
Bit 2 = Error
Bit 3 = time delay active
Bit 4 = locked out
---
HL

8251 8251 u 16bit Module status relay monitoring


High Byte: actual status according error list
Low Byte: modul status
Bit 0 = Active
Bit 1 = Warning
Bit 2 = Error
Bit 3 = time delay active
Bit 4 = locked out
---
HL

8252 8252 u 16bit Module state switching frequency monitoring


High Byte: actual status according error list
Low Byte: modul status Bit coded
Bit 0 = Active
Bit 1 = Warning
Bit 2 = Error
Bit 3 = time delay active
Bit 4 = locked out
---
HL

8260 8260 u 16bit Module state generaly


High Byte: actual status according error list
Low Byte: modul status
Bit 0 = Active
Bit 1 = Warning
Bit 2 = Error
Bit 3 = time delay active
Bit 4 = locked out
---
HL

Modbus DP 1 VISU 20 25. Sep. 18 3 / 10


Modbus DP 1 VISU 20

Start End type description

8262 8262 u 16bit Module state supply voltage monitoring


High Byte: actual status according error list
Low Byte: modul status
Bit 0 = Active
Bit 1 = Warning
Bit 2 = Error
Bit 3 = time delay active
Bit 4 = locked out
---
HL

8276 8276 u 16bit Current term of the compressor


0..65.535 min

8278 8278 u 8bit Number of times <5 min


Number of times to determine of quasi- percentage distribution

8279 8279 u 8bit Number of times 5-9 min


Number of times to determine of quasi- percentage distribution

8280 8280 u 8bit Number of times 10-19 min


Number of times to determine of quasi- percentage distribution

8281 8281 u 8bit Number of times 20-29 min


Number of times to determine of quasi- percentage distribution

8282 8282 u 8bit Number of times 30-59 min


Number of times to determine of quasi- percentage distribution

8283 8283 u 8bit Number of times 60-119 min


Number of times to determine of quasi- percentage distribution

8284 8284 u 8bit Number of times 120-300 min


Number of times to determine of quasi- percentage distribution

8285 8285 u 8bit Number of times> 300 min


Number of times to determine of quasi- percentage distribution

8302 8302 u 16bit Sum of shutdowns due to open circuit alarm

8303 8303 u 16bit Sum of shutdowns due to sensor short circuit alarm

8306 8306 u 16bit Sum of shutdowns due to motor temp static alarm

8307 8307 u 16bit Sum of shutdowns due to motor temp static lockout

8316 8316 u 16bit Sum of shutdowns due to phase loss alarm

8317 8317 u 16bit Sum of lockouts due to phase loss alarm

8318 8318 u 16bit Sum of shutdowns due to switching frequency limit alarm

8319 8319 u 16bit Sum of shutdowns due Relaisueberbrueckung message

8331 8331 u 16bit Sum of lockouts due to wrong phase sequence alarm

Modbus DP 1 VISU 20 25. Sep. 18 4 / 10


Modbus DP 1 VISU 20

Start End type description

8334 8334 u 16bit Residual delay time


0..65533 sec estimated time period until the compressor can be switched on again,
65.535 = locked switch off, 65.534 = indefinite time

8336 8336 u 8bit Time since last error in minutes / hours


in the range 0..120 = value in minutes
in the range 121..238 = 3..120h

8337 8337 u 8bit Time since last error in days


0 = 0 Tage
1…246 = 6…251 Tage

8338 8338 u 16bit Compressor run time was during the "Relay bridging" recognized
0..65.535 * 10min

8342 8342 u 16bit Sum of warnings due to phase asymmetry alarm

8344 8344 u 16bit Sum of shutdowns due to phase asymmetry alarm

8345 8345 u 16bit Sum of lockouts due to phase asymmetry alarm

8348 8348 u 16bit Sum of shutdowns due to an internal error

8349 8349 u 16bit Sum of shutdowns due to an internal error

8350 8350 u 16bit Sum of warnings due to module supply undervoltage alarm

8351 8351 u 16bit Sum of shutdowns due to module supply undervoltage

8352 8352 u 8bit Error memory: Error number of the last error

8353 8353 u 8bit Error memory: time difference of the last error to the previous
in the range 0.. .120 = value in minutes
in the 121…238 = value in hours 3..120 h

8356 8356 u 8bit Error-memory: error number index -1

8357 8357 u 8bit Error-memory time difference index - 1


in the range 0.. .120 = value in minutes
in the 121…238 = value in hours 3..120 h

8360 8360 u 8bit Error-memory: error number index -2

8361 8361 u 8bit Error-memory time difference index - 2


in the range 0.. .120 = value in minutes
in the 121…238 = value in hours 3..120 h

8364 8364 u 8bit Error-memory: error number index -3

8365 8365 u 8bit Error-memory time difference index - 3


in the range 0.. .120 = value in minutes
in the 121…238 = value in hours 3..120 h

8368 8368 u 8bit Error-memory: error number index -4

8369 8369 u 8bit Error-memory time difference index - 4


in the range 0.. .120 = value in minutes
in the 121…238 = value in hours 3..120 h

Modbus DP 1 VISU 20 25. Sep. 18 5 / 10


Modbus DP 1 VISU 20

Start End type description

8372 8372 u 8bit Error-memory: error number index -5

8373 8373 u 8bit Error-memory time difference index - 5


in the range 0.. .120 = value in minutes
in the 121…238 = value in hours 3..120 h

8376 8376 u 8bit Error-memory: error number index -6

8377 8377 u 8bit Error-memory time difference index - 6


in the range 0.. .120 = value in minutes
in the 121…238 = value in hours 3..120 h

8380 8380 u 8bit Error-memory: error number index -7

8381 8381 u 8bit Error-memory time difference index - 7


in the range 0.. .120 = value in minutes
in the 121…238 = value in hours 3..120 h

8384 8384 u 8bit Error-memory: error number index -8

8385 8385 u 8bit Error-memory time difference index - 8


in the range 0.. .120 = value in minutes
in the 121…238 = value in hours 3..120 h

8388 8388 u 8bit Error-memory: error number index -9

8389 8389 u 8bit Error-memory time difference index - 9


in the range 0.. .120 = value in minutes
in the 121…238 = value in hours 3..120 h

8392 8392 u 8bit Error-memory: error number index -10

8393 8393 u 8bit Error-memory time difference index - 10


in the range 0.. .120 = value in minutes
in the 121…238 = value in hours 3..120 h

8396 8396 u 8bit Error-memory: error number index -11

8397 8397 u 8bit Error-memory time difference index - 11


in the range 0.. .120 = value in minutes
in the 121…238 = value in hours 3..120 h

8400 8400 u 8bit Error-memory: error number index -12

8401 8401 u 8bit Error-memory time difference index - 12


in the range 0.. .120 = value in minutes
in the 121…238 = value in hours 3..120 h

8404 8404 u 8bit Error-memory: error number index -13

8405 8405 u 8bit Error-memory time difference index - 13


in the range 0.. .120 = value in minutes
in the 121…238 = value in hours 3..120 h

8408 8408 u 8bit Error-memory: error number index -14

Modbus DP 1 VISU 20 25. Sep. 18 6 / 10


Modbus DP 1 VISU 20

Start End type description

8409 8409 u 8bit Error-memory time difference index - 14


in the range 0.. .120 = value in minutes
in the 121…238 = value in hours 3..120 h

8412 8412 u 8bit Error-memory: error number index -15

8413 8413 u 8bit Error-memory time difference index - 15


in the range 0.. .120 = value in minutes
in the 121…238 = value in hours 3..120 h

8416 8416 u 8bit Error-memory: error number index -16

8417 8417 u 8bit Error-memory time difference index - 16


in the range 0.. .120 = value in minutes
in the 121…238 = value in hours 3..120 h

8420 8420 u 8bit Error-memory: error number index -17

8421 8421 u 8bit Error-memory time difference index - 17


in the range 0.. .120 = value in minutes
in the 121…238 = value in hours 3..120 h

8424 8424 u 8bit Error-memory: error number index -18

8425 8425 u 8bit Error-memory time difference index - 18


in the range 0.. .120 = value in minutes
in the 121…238 = value in hours 3..120 h

8428 8428 u 8bit Error-memory: error number index -19

8429 8429 u 8bit Error-memory time difference index - 19


in the range 0.. .120 = value in minutes
in the 121…238 = value in hours 3..120 h

8500 8500 u 16bit Sum of warnings due to line undervoltage alarm

8501 8501 u 16bit Sum of warnings due to line overvoltage alarm

8502 8502 u 16bit Sum of shutdowns due to line undervoltage alarm

8503 8503 u 16bit Sum of lockouts due to line undervoltage alarm

8504 8504 u 16bit Sum of shutdowns due to line overvoltage alarm

8505 8505 u 16bit Sum of lockouts due to line overvoltage alarm

8508 8508 s 16bit Motor temperature cut-off value


± 327.00 ° C (value / 100)

Modbus DP 1 VISU 20 25. Sep. 18 7 / 10


Modbus DP 1 VISU 20

Start End type description

8554 8554 u 16bit Module status leakage monitoring 1


High Byte: actual status according error list
Low Byte: modul status Bit coded
Bit 0 = Active
Bit 1 = Warning
Bit 2 = Error
Bit 3 = time delay active
Bit 4 = locked out
---
HHLL

8555 8555 u 16bit Module status leakage monitoring 2


High Byte: actual status according error list
Low Byte: modul status Bit coded
Bit 0 = Active
Bit 1 = Warning
Bit 2 = Error
Bit 3 = time delay active
Bit 4 = locked out
---
HHLL

8556 8556 u 16bit Module state phase sequence

8557 8557 u 16bit Module state phase loss

8558 8558 u 16bit Module state phase imbalance

8560 8560 u 16bit Filling cycle time - before 120-144 h internal time
0 … 65535 in 10s raster

8562 8562 u 16bit Sum of warnings due to temperature sensor 1

8563 8563 u 16bit Sum of warnings due to temperature sensor 2

8564 8564 u 16bit Sum of shutdowns due to temperature sensor 1 alarm

8565 8565 u 16bit Sum of shutdowns due to temperature sensor 1 lockout

8566 8566 u 16bit Sum of shutdowns due to temperature sensor 1 Short circuit

8567 8567 u 16bit Sum of shutdowns due to temperature sensor 1 open circuit

8568 8568 u 16bit Sum of shutdowns due to temperature sensor 2 alarm

8569 8569 u 16bit Sum of shutdowns due to temperature sensor 2 lockout

8570 8570 u 16bit Sum of shutdowns due to temperature sensor 2 Short circuit

8571 8571 u 16bit Sum of shutdowns due to temperature sensor 2 open circuit

8572 8572 u 16bit Sum of warnings for leak monitoring 1

8573 8573 u 16bit Sum of warnings for leak monitoring 2

8574 8574 u 16bit Sum of shutdowns due to leakage monitoring 1 alarm

8575 8575 u 16bit Sum of shutdowns due to leakage monitoring 1 lockout

Modbus DP 1 VISU 20 25. Sep. 18 8 / 10


Modbus DP 1 VISU 20

Start End type description

8576 8576 u 16bit Sum of shutdowns due to leakage monitoring 2 alarm

8577 8577 u 16bit Sum of shutdowns due to leakage monitoring 2 lockout

8578 8578 u 16bit Total of warnings due to standard signal 1

8579 8579 u 16bit Sum of shutdowns due to standard signal 1 sensor error

8580 8580 u 16bit Sum of shutdowns due to standard signal 1 alarm

8581 8581 u 16bit Sum of shutdowns due to standard signal 1 lockout

8582 8582 s 16bit Temperature sensor 1 temperature value

8583 8583 s 16bit Temperature sensor 1 switch-off value

8584 8584 s 16bit Temperature sensor 2 temperature value

8585 8585 s 16bit Temperature sensor 2 cut-off value

8586 8586 u 16bit Temperature sensor 1 ohm value

8587 8587 u 16bit Temperature sensor 2 ohm value

8588 8588 u 16bit Leakage monitoring 1 ohm value

8589 8589 u 16bit Leakage monitoring 1 switch-off value

8590 8590 u 16bit Phase voltage L1

8591 8591 u 16bit Phase voltage L2

8592 8592 u 16bit Phase voltage L3

8594 8594 u 16bit Standard signal 1 value

8595 8595 u 16bit Standard signal 1 cut-off value

8596 8596 u 16bit Leakage monitoring 2 ohm value

8597 8597 u 16bit Leakage monitoring 2 switch-off value

8598 8598 u 16bit Sum of engine temperature warnings

8600 8600 u 16bit Sum of warnings due to switching frequency limitation

8601 8601 u 16bit Sum of shutdowns due to switching frequency limitation Lockout

8602 8602 u 16bit Module state line undervoltage

8603 8603 u 16bit Module state line overvoltage

8604 8604 u 16bit Standard signal 1 value minimum

8605 8605 u 16bit Standard signal 1 value maximum

8606 8606 u 16bit Standard signal 1 unit 1st character

8607 8607 u 16bit Standard signal 1 unit 2nd character

Modbus DP 1 VISU 20 25. Sep. 18 9 / 10


Modbus DP 1 VISU 20

Start End type description

8608 8608 u 16bit Temperature sensor Sensor setting


High byte: Temperature sensor 2 Sensor type
Low byte: Temperature sensor 1 Sensor type

8609 8609 u 16bit Leakage sensor Sensor setting


High byte: leakage sensor 2 sensor type
Low byte: leak sensor 1 sensor type

8612 8612 u 16bit Time to service


0 ... 65,534, 65,535 interval expired

8613 8613 u 16bit service status


0 = inactive,> 0 active

8619 8619 u 16bit Standard signal 1 limit sensor detection


0…65535

8620 8620 u 16bit Motor sensor sensor setting


Low byte: sensor type