0% found this document useful (0 votes)
97 views1 page

Mid187 Ppid1181 Se9103

This document provides diagnostic information for a vehicle with fault codes related to ground dependent steering pressure. Specifically: 1) The vehicle control unit detected the voltage was above 4.75V for the sensor, indicating a possible short circuit or open circuit issue. 2) The vehicle control unit detected the voltage was below 0.25V for the sensor, indicating it is not connected or there is an open circuit in the signal line. 3) Details are given on the fault mode, detection conditions, symptoms, possible causes, and instructions for further action to diagnose the issue.

Uploaded by

Awan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
97 views1 page

Mid187 Ppid1181 Se9103

This document provides diagnostic information for a vehicle with fault codes related to ground dependent steering pressure. Specifically: 1) The vehicle control unit detected the voltage was above 4.75V for the sensor, indicating a possible short circuit or open circuit issue. 2) The vehicle control unit detected the voltage was below 0.25V for the sensor, indicating it is not connected or there is an open circuit in the signal line. 3) Details are given on the fault mode, detection conditions, symptoms, possible causes, and instructions for further action to diagnose the issue.

Uploaded by

Awan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Volvo Guided Diagnostics

Date: Information Type:


27/11/22 0 Diagnostics Fault Codes 187: Vehicle Control Unit 1181: Ground dependent Steering
pressure
Profile:
A40G Volvo

MID187 PPID1181 / SE9103


Showing Selected Profile

Valid for serial numbers


Model Production site Serial number start Serial number stop
A40G Volvo

SAE code
MID/Control Unit MID187 Vehicle Control Unit
PID/PPID/SID/PSID PPID1181 Ground dependent Steering pressure
Machine display message
Text presentation SE9103

Reference Steering system, description

Fault mode diagnosis

Fault mode Detection conditions:The vehicle control unit (V-ECU) registers: that the voltage is
FMI 3 above 4.75 V (VB7)
Symptom: Possible causes:

No monitoring of ground- Signal line short-circuited to 5 V


dependent steering pressure or higher voltage
Open circuit on frame ground
cable
Defective sensor

Action SE9102/SE9103, description and measuring

Fault mode Detection conditions:The vehicle control unit (V-ECU) registers: that the voltage is
FMI 4 below 0.25 V (VB7)
Symptom: Possible causes:

No monitoring of ground- Sensor not connected (open


dependent steering pressure circuit)
Open circuit on signal line
Signal line short-circuited to
frame ground
Low feed voltage to sensor
Defective sensor