MC018-130 High Current Controller Data Sheet
MC018-130 High Current Controller Data Sheet
Product Highlights
Application development
Users develop MC018-130 High Current Controllers
® ®
applications with PLUS+1 GUIDE. This Microsoft
®
Windows based development environment features
a user-friendly, field proven, icon-based graphical
programming tool, application downloader, and
service/diagnostic tool.
Features
Inputs Outputs
• (4) Inputs • (8) Outputs
‒ (2) Universal (DIN/AIN/FreqIN/Rheo) ‒ (4) Universal (PWMOUT/DOUT/
Digital: Pull up (5 VDC), pull down (0 PVGOUT) that are user-defined as
VDC) or pull to center (2.5 VDC) either:
Analog: 0 to 0.375 VDC, 0 to 5.25 Digital: 15 A, configurable as source
VDC, or 0 to 36 VDC or sink
Frequency (timing): 1 Hz to 10 kHz PWM: 15 A (33 to 4000 Hz or 20 kHz),
Resistance: 0 to 10,000 ohm configurable as open or closed loop
‒ (1) Digital/Analog (DIN/AIN) that is with current control
user-defined as either:
Digital: Pull up (5 VDC), pull down (0 ‒ (4) Universal (PWMOUT/DOUT/
PVGOUT) that are user-defined as
VDC) or pull to center (2.5 VDC)
either:
Analog: 0 to 5.25 VDC or 0 to 36 VDC
Digital: 25 A, configurable as source
‒ (1) Digital/Analog/CAN shield
or sink
(DIN/AIN/CAN shield) that is user-
PWM: 25 A (33 to 4000 Hz or 20 kHz),
defined as either:
configurable as open or closed loop
Digital: Pull up (5 VDC), pull down (0
with current control
VDC) or pull to center (2.5 VDC)
Analog: 0 to 5.25 VDC or 0 to 36 VDC
CAN shield
Characteristics
nmp1479876497075
C2
80.2
M6 locknut
Install torque 7.344 N•m
2X 10 M6 cvi1479876589499
Threaded stud
ohj1479876644922
4 25A PWM
C3, C4
Device must be mounted on a flat metal surface that is less than Pin Controller function Description
70° C (158° F) for full output capability. C3-P1 Battery power 120A battery connection
If the metal surface is greater than 70° C (158° F), built in thermal (externally fused)
protection will limit the maximum output current allowed for all C4-P1 Battery ground 120A battery connection
PWM’s.
Use care when wiring mating connector. Pinouts listed are for
device pins.
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.