0% found this document useful (0 votes)
17 views

FGL FGL: Lighting and Small Power Cable Routing Layout Drawing-Ss02

The document contains notes and a diagram for installing rain gutters and lighting fixtures on a building. It includes details like using 25mm galvanized iron conduits and junction boxes to run wiring to flood lights, switches, and sockets mounted at 2650mm above floor level. Foundation pedestals for supporting the infrastructure are to be provided separately. Dimensions are in millimeters unless otherwise specified.

Uploaded by

Raees
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
17 views

FGL FGL: Lighting and Small Power Cable Routing Layout Drawing-Ss02

The document contains notes and a diagram for installing rain gutters and lighting fixtures on a building. It includes details like using 25mm galvanized iron conduits and junction boxes to run wiring to flood lights, switches, and sockets mounted at 2650mm above floor level. Foundation pedestals for supporting the infrastructure are to be provided separately. Dimensions are in millimeters unless otherwise specified.

Uploaded by

Raees
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

A B C D E F

GENERAL NOTES

1. ALL DIMENSIONS ARE IN MM UNLESS OTHERWISE SPECIFIED.

7 RAIN GUTTER WITH 7


DOWN SPOUT

STEEL ROD
SUPPORT

GI CONDUITS
WITH SUPPORT

25mm GI JUNCTION BOX 25mm GI CONDUIT FOR 25mm GI CONDUIT FOR


LIGHT MOUNTED
FOR FLOOD LIGHTING LIGHTING DOWN TO LIGHTING & SMALL POWER
AT 2650mm
SWITCH
ABOVE FFL.

WEATHER PROOF 25mm GI CONDUIT


SWITCH DOWN TO SWITCH &
SW9,SW8
10 SOCKET
D1

2650

2650
330 02
6 6
01 09

1250
17

18

REFERENCE DRAWINGS:

500 400
Sl.No DOCUMENT NAME DOCUMENT NUMBER
FOUNDATION PEDESTAL

FOUNDATION PEDESTAL

FOUNDATION PEDESTAL
PROVIDED BY OTHERS

PROVIDED BY OTHERS

PROVIDED BY OTHERS
OVERALL GENERAL ARRANGEMENT 7000-WGEL-N004-BNGL-G00000-
1
& ELEVATION DRAWINGS (SS02) ZV-B01-41059-001
CABLE CELLAR CABLE CELLAR 7000-WGEL-N004-BNGL-G00000-
CABLE CELLAR 2 UTILITY LOAD SCHEDULE (SS02)
ZV-C06-41059-001
5 5

900
SLD (LIGHTING AND SMALL POWER 7000-WGEL-N004-BNGL-G00000-
FGL FGL 3
DB) (SS02) ZV-C03-41059-001
7000-WGEL-N004-BNGL-G00000-
4 MCT DETAILS (SS02)
ZV-D07-41059-005
EQUIPMENT EARTHING & 7000-WGEL-N004-BNGL-G00000-
5
LIGHTNING LAYOUT (SS02) ZV-E02-41059-003

RAIN GUTTER WITH


DOWN SPOUT

AC DUCT
OPENING
500x450 MM STEEL ROD
4 AC DUCT OPENING SUPPORT 4

25mm GI JUNCTION BOX GI CONDUITS


WITH SUPPORT
LIGHT MOUNTED CABLE TRAY LEGEND
FOR FLOOD LIGHTING 25mm GI CONDUIT FOR AT 2650mm 25mm GI CONDUIT
LIGHTING & SMALL POWER 25mm GI CONDUIT FOR ABOVE FFL.
LIGHTING & SMALL POWER
DOWN TO SWITCH &
SOCKET
-50/100/150/200/300 x 50mm
CABLE TRAY
SWITCH
SW1,SW2
-16/14/12 TERMINAL EARTH BARS

2650
1 2 3 4 5 6 7 8

12
01
21a

1250
3 3

500
500 400
FOUNDATION PEDESTAL

FOUNDATION PEDESTAL

FOUNDATION PEDESTAL

FOUNDATION PEDESTAL
PROVIDED BY OTHERS

PROVIDED BY OTHERS

PROVIDED BY OTHERS

PROVIDED BY OTHERS
CABLE CELLAR
CABLE CELLAR

900
FGL FGL

2 2

EPC CONTRACTOR: END User :


DRAWING TITLE:
CONTRACT NO

File Name : N004-SS02 921BGCEPS LIGHTING AND SMALL BGC PO NO: WG0011
03A Issued for Approval 05-SEP-2021 RN JH POWER CABLE ROUTING LAYOUT ABB JOB NO SCALE SIZE SHT CONT REV
1 02A Issued for Approval 11-JUL-2021 RN JH DRAWING-SS02 33419006 1:1 A3 04 05 03A 1
01A Issued for Approval 16-MAY-2021 RN JH ABB DRAWING NO: AE-33419006 - LAYT - 004
INDUSTRIES FZE
REV NO DESCRIPTION DATE DESIGNED CHECKED ABB APPD iME APPD TAK APPD DUBAI END USER NO: 7000-WGEL-N004-BNGL-G00000-ZV-E02-41059-004