0% found this document useful (0 votes)
17 views

EMC Descriptions 20 Nov 2023

The LC600 from Laplace Instruments is an EMC test cell that operates from 30 MHz to 3 GHz (optional 6 GHz). It complies with IEC61000-4-20 and is calibrated for emissions and immunity testing of equipment up to 60x60x60 cm. It achieves commercial test levels with low RF power input and has an efficient design that can deliver 20V/m with 25 W of RF input power. The LBX5750 from Labifix Innovations is an RF shielded test enclosure that operates from 20 MHz to 12 GHz. It has EMI filters on data and power ports to ensure clean test results. It provides excellent shielding effectiveness across 1-3 GHz and has

Uploaded by

singhpramod2492
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
17 views

EMC Descriptions 20 Nov 2023

The LC600 from Laplace Instruments is an EMC test cell that operates from 30 MHz to 3 GHz (optional 6 GHz). It complies with IEC61000-4-20 and is calibrated for emissions and immunity testing of equipment up to 60x60x60 cm. It achieves commercial test levels with low RF power input and has an efficient design that can deliver 20V/m with 25 W of RF input power. The LBX5750 from Labifix Innovations is an RF shielded test enclosure that operates from 20 MHz to 12 GHz. It has EMI filters on data and power ports to ensure clean test results. It provides excellent shielding effectiveness across 1-3 GHz and has

Uploaded by

singhpramod2492
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 3

EMC Test Cell from 30 MHz to 3 GHz for Emissions and Immunity Testing

The LC600 from Laplace Instruments is an EMC Test Cell with a frequency
range from 30 MHz to 3 GHz (optional 6 GHz). It complies with the IEC61000-4-
20 standard and is calibrated for emissions and immunity testing. The cell has
an EUT testing size limit of 60x 60 x 60 cm, is equipped with a field sensor, and
achieves commercial test-level standards with low RF power input
requirements. It has an antenna factor correlated to 3m OATS for emissions
calibration. The test cell has an efficient design that can deliver 20V/m with 25
W of RF input power.
The LC600 cell features a balanced dual septum design with an impedance
conversion network. This design modification optimizes the volume available
for the Equipment Under Test (EUT) within the external dimensions of the cell,
significantly enhancing field linearity and matching the conditions of an OATS
chamber. Its EUT volume is fully encased in structural polycarbonate, ensuring
robust support for heavy products. Cell access is facilitated through a spacious,
full-height door at the cell's end.
This test cell is available in an enclosure that measures 3.2 x 1.6 x 1.3 m and
includes USB, RS232 and RS485 interfaces. It has a stainless-steel construction
with welded construction and a Polypropylene EUT chamber.

Bench-top EMC Test Enclosure from 20 MHz to 12 GHz


The LBX5750 from Labifix Innovations is an RF Shielded Test Enclosure that is
designed for wireless device testing up to 12 GHz. This shielded enclosure
comes equipped with EMI filters on data ports and power lines, ensuring clean
and precise test results. Built to endure the rigors of daily use, the LBX5750 has
a rugged welded construction that ensures durability and longevity. It has an
interior dimension of 18 x 28 x 28 inches and an outer dimension of 20 x 30 x
30 inches. This test enclosure incorporates an RF gasket system that prevents
any leakage of RF signals ensuring maximum shielding effectiveness. It provides
excellent shielding effectiveness (isolation) across different frequency ranges
with a shielding effectiveness of more than 95 dB (from 1 to 3 GHz).
The LBX5750 has I/O options, which include filtered ethernet, filtered USB 2.0
& 3.0, AC/DC power filter, and high-performance honeycomb air vents for
adequate airflow. It is suitable for various applications, including Wi-Fi 802.11,
forensics, security, R&D, quality assurance tests, Bluetooth, Zigbee, cellular
(4G, 5G, LTE, WiMAX), and wireless medical devices.

Electromagnetic Absorber from 800 MHz to 110 GHz for Oblique Incidence
The IS-SM050-TE from TDK RF Solutions is an eElectromagnetic magnetic
aAbsorber for frequencies from 800 MHz to 110 GHz. It that has a pyramidal
shape with a length of 50 cm and delivers excellent performance for
microwave and millimeter waves. This absorber consists of a polyethylene
foam base, utilizes the ohmic loss of carbon and is stable against chemicals
with long service life. It has a typical absorption characteristic of up to 55 dB
and is specifically designed for oblique incidence. This absorber is fire retardant
(NRL Classes 1, 2 and 3; UL-94HBF) and

uses materials that, when burned, emit gases that are relatively harmless to
humans. It is available in a standard dimension that measures 600 x 600 x 500
mm and is suitable for cellular testing and various wireless access operations.

500 V/m E-Field Generator from 10 kHz to 100 MHz


The EFG-03 from TDK RF Solutions is an Electric Field Generator that operates
from 10 kHz to 100 MHz. It generates an E-field of more than 500 V/m
between the elements and is ideal for immunity test applications that require
high input power handling and high-density fields in a compact design. This
generator has an integrated mast system that enables comprehensive manual
control over height, tilt, and polarization. The positioning gimbal of this
generator enables precise manual tilt adjustments within a ±10° range,
coupled with a full 360° rotation capability with convenient indexing at 0° and
90° for swift polarization changes. It includes a robust transformer design to
improve the low-frequency response. This generator can handle an input
power of up to 3500 W without the use of forced air or water cooling.
The EFG-03 has the mounting arm securely locked in place using a dedicated
pin mechanism, and the mast, base, and mounting arm are built to withstand
heavy-duty usage and are fortified with a protective water seal. For added
safety and manoeuvrability, the mast is equipped with four locking swivel
casters. It is available in a housing that measures 34 x 61 inches with a 7/16
(female) input connector. This E-field generator has a configurable structure in
which height can be adjusted up to 122 cm according to user requirements