QC02019120 Bny DRW PLN Arc N1 Mec 20901 0D Wip

This document provides general notes for a project including references to additional drawings and schedules for areas, rooms, plans, elevations, and sections. It also notes that individual drawing notes should be referenced for assets/areas undergoing further design development or coordination.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
50 views1 page

QC02019120 Bny DRW PLN Arc N1 Mec 20901 0D Wip

This document provides general notes for a project including references to additional drawings and schedules for areas, rooms, plans, elevations, and sections. It also notes that individual drawing notes should be referenced for assets/areas undergoing further design development or coordination.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

1 2 3 4 5 6 7

Client:
GENERAL NOTES:

• REFER TO THE FOLLOWING BNY SERIES FOR


ADDITIONAL INFORMATION:

AREAS & ROOMS SCHEDULES QC02019120-SCH-ARC


GA PLANS QC02019120-PLN-ARC
GA ELEVATIONS QC02019120-ELE-ARC
GA SECTIONS QC02019120-SEC-ARC

ADDITIONAL INFORMATION:

• REFER TO INDIVIDUAL DRAWINGS NOTES FOR


F ASSETS/AREAS AND ZONE GOING UNDER FURTHER
DESIGN DEVELOPMENT OR FURTHER COORDINATION.
F

ENTRANCE
Project Name / Logo:
Speed Park Buildings,
Experience Centre and
N1.20 N1.19 N1.18 N1.17 N1.16 N1.15 N1.14 N1.13 N1.12 N1.11 N1.10 N1.9 N1.8 N1.7 N1.6 N1.5 N1.4 N1.3 N1.2 N1.1 Motorsport Park

QC02019120
Key Plan

N1.A N1.A
N1.AB

ARY
N

ND
Q
N1.AA

OU
N1.S

TB
E N1.B N1.B E
N1.AC

PL O
Notes:
All dimensions to be verified on site. Do not scale this drawing. All
discrepancies to be clarified with project Architect.
N1.C N1.C This drawing is the property of Benoy and is issued on the condition
it is not reproduced, retained or disclosed to any unauthorised
person, either wholly or in part without written consent of Benoy Ltd.

Ordnance Survey material is used with the permission of The


N1.U Controller of HMSO, Crown copyright AR 159670.

The CDM hazard management procedures for the Benoy aspects of


the design of this project are to be found on the "Benoy - Designer's
Hazard Identification and Management Sheet" and/or drawings. The
full project design teams comprehensive set of hazard management
N1.AD procedures are available from the PRINCIPLE DESIGNER/Safety
Coordinator appointed for the project.
N1.D N1.D

ROOMS LEGEND
TOILET
N1-L09-002 MEC
LIFT LOBBY 31.7 m²
N1-L09-006 MEC TERRACE
TOILET
N1.E PL O 15.5 m²
N1.E Void
N1.T T BO TOILET PL07
N1-L09-008
23.4 m²
UN N1-L09-005 N1-L09-007
DAR 4.7 m² 10.1 m²
Y

From L07

To L07
ST02
D N1-L09-023 D
17.2 m²
AHU
N1-L09-004
ST01 73.9 m²
N1-L09-027
N1.F 20.3 m²
N1.F

FROM L07
N1.AE

TO L07
ELECTRICAL
ROOM
N1-L09-003
IDF 17.6 m²
N1-L09-011
12.1 m²

ST05
N1.G N1-L09-029 N1.G
19.5 m²
TEMPORARY
PL01 EXHIBIT
N1-L09-012 MUSEUM
9.4 m² N1-L09-032
2,119.0 m²
ST06 PL02
N1-L09-025 N1-L09-013
24.9 m² 9.0 m²
N1.H N1.H
PL03
N1-L09-014 N1.V
OBSERVATION 733.00 FFL 9.4 m²
VIP LOUNGE AHU 733.00 FFL
TERRACE N1-L09-034 N1-L09-009 733.00 FFL
N1-L09-033
859.5 m² 83.7 m²
3,098.5 m²
PL04

C
N1-L09-015
9.4 m²
N1.U C
Rev Date Description By Chk'd
N1.J PL05
IMMERSIVE
IMMERSIVE
N1.J * Indicates issued drawing with previous numbering system
ST07
? *A01 02.12.2022 WIP Issue BNY YB
N1-L09-030
? N1-L09-016 EXHIBITION
9.1 m² N1-L09-001 *A02 16.12.2022 50% CD Issue BNY ML
25.1? m² *A03 20.01.2023 100% CD SPD Information BNY YB
2,178.8 m²
release
PL06 0A 10.02.2023 100% CD Issue BNY BNY
N1-L09-017
0B 02.08.2023 100% SD ISSUE BNY IB/YB
9.3 m²
0C 27.11.2023 VO 02 100% SD ISSUE BNY YB
0D 05.02.2024 WIP issue for Building Permit BNY YB
ST08
N1-L09-024
N1.K 19.5 m² N1.K
ELECTRICAL
ROOM
?
?
N1-L09-010
15.4
? m² PL08
ST03 N1-L09-019
N1-L09-028 10.3 m²
18.7 m²
LIFT LOBBY N1.AF
N1-L09-020
ELECTRICAL
ST04 15.2 m² Consultant / Lead Designer:
N1.L N1-L09-026 ROOM
N1-L09-021 N1.L
16.6 m²
25.9 m²

AHU
N1-L09-018
86.3 m²
N1.S N1.M CL01
N1-L09-022 N1.M
42.0 m²
B Contractor B

N1.N N1.N
N1.AG
Sub-Consultant/Sub-Contractor:

N1.V

N1.P N1.P E: [email protected]


T: +44 (0)20 7726 8999 www.benoy.com

Drawing Title:

N1-MEC - NINTH FLOOR PLAN


(+733.00)
N1.AH
N1.Q N1.Q
N1.T
Y

N1.AK
AR
ND

Reference File:
OU

QC02019120-BNY-MOD-3DM-ARC-N1-MEC-30000.rvt
A A
TB

N1.AJ Authored By:


O
PL

BNY
N1.R N1.R Checked By
IB
Q
Scale Sheet Size
As indicated @ A0

N
Drawing Number
2 2 4 6 8 10

1
LEVEL 09 MEC Nineth Floor Plan (+734.00) 1-200 0
Project No. Orig. Type
Sub
Type Disc. Zone
Facility
Code Serial Number

Scale: 1 : 200 N1.20 N1.19 N1.18 N1.17 N1.16 N1.15 N1.14 N1.13 N1.12 N1.11 N1.10 N1.9 N1.8 N1.7 N1.6 N1.5 N1.4 N1.3 N1.2 N1.1 SCALE 1: 200 m
QC02019120-BNY-DRW-PLN-ARC-N1-MEC-20901

1 2 3 4 5 6 7

You might also like