Cooper MEDC SM87SL3 HXBAB Sinalizador Luminoso 26200243 Ficha Tecnica Catalogo Data Sheet
Cooper MEDC SM87SL3 HXBAB Sinalizador Luminoso 26200243 Ficha Tecnica Catalogo Data Sheet
Explosion-proof, Weatherproof
IN EL
E
L STE
A B Features
A IL ESS 4 Zone 1 and Zone 2 use.
AV INL
A 4 Exd.
ST 4 *ATEX approved, Ex II 2GD.
4 *BASEEFA certified.
4 IECEx certified Gb, Db.
4 *UL listed for USA and Canada:
Class I, Div. 1 & 2, Groups C & D.
Class I, Zone 1, AExd IIB T6.
4 *CSA certified.
4 CUTR certified
4 *Chinese (CQST) certified.
4 Brazilian (Inmetro) certified.
4 IP66 & 67.
4 *Certified temperature: –55ºC to +70ºC.
4 *LED, xenon, fluorescent, filament.
4 Marine grade alloy, stainless steel option or GRP.
XB11SL
4 Close-coupled and pre-wired to customer’s
SM87SL requirements.
*Model dependent.
Introduction
This range of versatile status lights has been designed to suit various
offshore and onshore applications.
Note: Units shown are for illustration purposes only, other variants
are available.
Web: www.medc.com
114
Certification and Specification
SM87SL XB11SL
Lamp Types: LED 192 candela. Lamp Types: Xenon 5 joules.
Xenon 6 joules maximum. Fluorescent 10W or 5W.
Fluorescent 10W or 5W. Filament 10W.
Filament 40W maximum. Certification: Certified to IEC60079-0, IEC60079-1, IEC60079-31.
Certification: Certified to IEC60079-0, IEC60079-1, IEC60079-31. Certified to EN60079-0, EN60079-1, EN60079-31.
Certified to EN60079-0, EN60079-1, EN60079-31. ATEX Cert. No. BAS99ATEX2195.
ATEX Cert. No. Baseefa 03ATEX0222. Ex II 2 GD Ex d IIB T4/T5/T6 Gb, Ex tb IIIC 70ºC…110ºC.
Ex II 2 GD Ex d IIC T5/T6 Gb, Ex tb IIIC 65ºC…100ºC Db. IECEx Cert. No. IECEx BAS 10.0101.
IECEx Cert. No. IECEx BAS 09.0059. Ex d IIB T4/T5/T6 Gb, Ex tb IIIC T70ºC…T110ºC Db.
Ex d IIC T3/T4/T5/T6 Gb, Ex tb IIIC T55ºC…T155ºC Db. UL Listed for USA and Canada:
UL Listed for USA and Canada: Class I, Div 2, Groups C & D, Class I, Zones 1 & 2,
Class I, Div 1, Groups C & D, Class I, Zone 1, AExd IIB T5/T6. Listing No. E187894 (XB11 only).
AExd IIB T6, Listing No. E187894. CUTR Certified: 1Ex d IIC T5/T6 Gb, Ex tb IIIC T65ºC/ T80ºC/ T95ºC Db (HXB).
CSA Certified: Class I, Div 1 & 2, Group D. Cert. No. 96406. 1Ex d IIC T6 Gb, Ex tb IIIC T55ºC/ T70ºC Db (LED).
CUTR Certified: 1Ex d IIB T4/T5/T6 Gb, Ex tb IIIC 75ºC/90ºC/105ºC Db. 1Ex d IIC T4 Gb, Ex tb IIIC T110ºC Db (XBT).
Chinese Certified: Exd IIC T4 (Filament), Exd IIC T6 (Fluorescent & Chinese Certified: Exd IIB T5/T6.
Xenon). Brazilian (Inmetro) Certified: BR-Ex d IIB T4/T5/T6.
Brazilian (Inmetro) Certified: BR-Ex d IIC T3/T4/T5/T6. Voltage Frequency: 50 Hz as standard. 60 Hz available if required.
Voltage Frequency: 50 Hz as standard. 60 Hz available if required. Xenon Voltages: 24V d.c., 110V, 240V a.c.
Xenon Voltages: 24, 48V d.c. 110, 120, 240, 254V a.c. (see XB11 data sheet for further information).
(see SM87 HXB data sheet for further information). Filament Voltages: 24, 48V d.c., 110, 220, 240, 254V a.c.
Filament Voltages: 12, 24, 48V d.c., 110, 220, 240, 254V a.c. (see FL11* data sheet for further information).
(see SM87 LU3 data sheet for further information). Fluorescent Voltages: 24V d.c., 240V a.c.
Fluorescent Voltages: 12, 24, 48V d.c., 220, 240, 254V a.c. (see FL11* data sheet for further details).
(see SM87 LU1 data sheet for further information). Lamp Colours: Red, Amber, Yellow, Green, Blue or Clear.
Lamp Colours: Red, Amber, Yellow, Green, Blue or Clear. Terminals: 2.5mm2 max.
Terminals: 2.5mm2 max. Wiring: Standard configuration of internal wiring is to common the
Wiring: Standard configuration of internal wiring is to common the negative/neutral connections.
negative/neutral connections. If individually wired lamps are required, please state requirements.
If individually wired lamps are required, please state requirements. Entries: 1 x M20.
Entries: Up to 3 x M20 or M25 ISO. Enclosure: GRP.
Enclosure: LM 25TF Marine Grade Alloy. Lens: Glass.
Lens: Glass. Finish: Natural black or painted to customer’s specification.
Finish: Painted to customer’s specification. Ingress Protection: IP66 & 67.
Ingress Protection: IP66 & 67. Ambient Temp. –55ºC to +70ºC.
Ambient Temp. –20ºC to +55ºC (LED & Fluorescent). Gland Type: Exd.
–55ºC to +70ºC (Xenon Filament).
*NOTE: FL11 currently not available UL listed.
Gland Type: Exd.
All specifications, dimensions, weights and tolerances are nominal (typical) and MEDC reserve the right to vary all data without prior notice.
No liability is accepted for any consequence of use.
6DS082/R 02/15