0% found this document useful (0 votes)
6 views

Tarrace

This document provides a summary of the design of a two-way slab for a terrace ground floor panel. It includes input data on slab dimensions and properties, applied loads, material strengths, calculated design moments for short and long spans, and reinforcement calculations and schematic. Reinforcement of #3 bars at 10 inches is designed for short and long span positive and negative moments based on ACI coefficient calculations to satisfy strength and serviceability requirements. Shear checks show capacity is sufficient.

Uploaded by

Asif
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
6 views

Tarrace

This document provides a summary of the design of a two-way slab for a terrace ground floor panel. It includes input data on slab dimensions and properties, applied loads, material strengths, calculated design moments for short and long spans, and reinforcement calculations and schematic. Reinforcement of #3 bars at 10 inches is designed for short and long span positive and negative moments based on ACI coefficient calculations to satisfy strength and serviceability requirements. Shear checks show capacity is sufficient.

Uploaded by

Asif
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

DESIGN OF TWO-WAY SLAB BY ACI-COEFFICIENTS

GROUND FLOOR SLAB


PANEL No : TARRACE

Input Data:
Slab Dimensions
Short Span = 12.75 ft
Long Span = 13.4271 ft
Span Ratio = 12.75 / 13.4271 = 0.95
Slab Thickness (reqd) = 2 x (12.75+13.4271) x 12 / 180 = 3.49 in
Slab Thickness (prvd) = 6. in

Edge Conditions
Short Span Edge Condition = One Edge Continuous
Long Span Edge Condition = One Edge Continuous

Applied Loads
Slab self wt = 75.00 psf
Service Dead Load = 20 psf
Service Live Load = 30 psf
Material Strengths
Concrete Strength = 4 ksi
Steel Yield Strength = 60 ksi

Design Moments
Loads
Total Ultimate DL =1.4(75 + 20) = 133 psf
Total Ultimate LL =1.7(30) = 51 psf
Total Ultimate Load =133 + 51 = 184 psf

Short Span Moments


Positive Moment DL Mua(dl)+ = 0.03 x 133 x 12.75^2 = 0.649 k-ft
Positive Moment LL Muall+ = 0.035 x 51 x 12.75^2 = 0.290 k-ft
Total Postive Short Span Moment Mua+ = ---------------------------------> = 0.939 k-ft

Negative Moment on Discontinuous Edge = 1/3 x 0.939 = 0.313 k-ft


Negative Moment on Continuous Edge = 0.055 x 184 x 12.75^2 = 1.645 k-ft

Long Span Moments


Positive Moment DL Mubdl+ = 0.024 x 133 x 13.4271^2 = 0.575 k-ft
Positive Moment LL Mubll+ = 0.029 x 51 x 13.4271^2 = 0.267 k-ft
Total Postive Long Span Moment Mub+ = ---------------------------------> = 0.842 k-ft

Negative Moment on Discontinuous Edge = 1/3 x 0.842 = 0.281 k-ft


Negative Moment on Continuous Edge = 0.045 x 184 x 13.4271^2 = 1.493 k-ft
DESIGN OF TWO-WAY SLAB BY ACI-COEFFICIENTS
GROUND FLOOR SLAB
PANEL No : TARRACE

Reinforcement Calculations
Along Short Span
Positive Steel
Mu=0.94 k-ft ; b=12 in ; d=5.063 in ; fc'=4ksi ; fy= 60 ksi
As+ = 0.85 x 4 / 60 x [1 - [1-2 x 12 x0.939/(0.9x0.85x4x12x5.063^2) ]^0.5 ] x 12 x 5.063
= 0.041 sq.in.
Asmin = 0.0018 x 12 x 6 = 0.130 sq in
use As+ = 0.130 sq.in. (#3 @ 10 in )
Negative Steel
Mu=0.31 k-ft ; b=12 in ; d=5.063 in ; fc'=4ksi ; fy= 60 ksi
As- = 0.85 x 4 / 60 x [1 - [1-2 x 12 x0.313/(0.9x0.85x4x12x5.063^2) ]^0.5 ] x 12 x 5.063
= 0.014 sq.in.
Asmin = 0.0018 x 12 x 6 = 0.130 sq in
use As- = 0.130 sq.in. (#3 @ 10 in )
Negative Steel
Mu=1.65 k-ft ; b=12 in ; d=5.063 in ; fc'=4ksi ; fy= 60 ksi
As- = 0.85 x 4 / 60 x [1 - [1-2 x 12 x1.645/(0.9x0.85x4x12x5.063^2) ]^0.5 ] x 12 x 5.063
= 0.073 sq.in.
Asmin = 0.0018 x 12 x 6 = 0.130 sq in
use As- = 0.130 sq.in. (#3 @ 10 in )

Along Long Span


Positive Steel
Mu=0.84 k-ft ; b=12 in ; d=4.688 in ; fc'=4ksi ; fy= 60 ksi
As+ = 0.85 x 4 / 60 x [1 - [1-2 x 12 x0.842/(0.9x0.85x4x12x4.688^2) ]^0.5 ] x 12 x 4.688
= 0.040 sq.in
Asmin = 0.0018 x 12 x 6 = 0.130 sq in
use As+ = 0.130 sq.in. (#3 @ 10 in )
Negative Steel
Mu=0.28 k-ft ; b=12 in ; d=5.063 in ; fc'=4ksi ; fy= 60 ksi
As- = 0.85 x 4 / 60 x [1 - [1-2 x 12 x0.281/(0.9x0.85x4x12x5.063^2) ]^0.5 ] x 12 x 5.063
= 0.012 sq.in
Asmin = 0.0018 x 12 x 6 = 0.130 sq in
use As- = 0.130 sq.in. (#3 @ 10 in )
Negative Steel
Mu=1.49 k-ft ; b=12 in ; d=5.063 in ; fc'=4ksi ; fy= 60 ksi
As- = 0.85 x 4 / 60 x [1 - [1-2 x 12 x1.493/(0.9x0.85x4x12x5.063^2) ]^0.5 ] x 12 x 5.063
= 0.066 sq.in
Asmin = 0.0018 x 12 x 6 = 0.130 sq in
use As- = 0.130 sq.in. (#3 @ 10 in )

Shear Check
Total load on the panel = 12.75 x 13.4271 x 184 = 31.4 kips

Shear Capacity of the section fVc = 0.85 x 2 x ( 4000 )^½ x 12 x 5 / 1000 = 6.45 k/ft

Shear along short side Vua = ( 0.45 x 31.4 ) / (2 x 12.75 ) = 0.55 k/ft <6.45 k/ft…. (O.K.)
Shear along long side Vub = ( 0.55 x 31.4 ) / ( 2 x 13.4271 ) = 0.64 k/ft <6.45 k/ft….(O.K).
#############################################################################
#####################################################################################################

# 3 @ 10.0 in

# 3 @ 10.0 in

12.75 ft
# 3 @ 10. in

# 3 @ 10. in

# 3 @ 10. in
# 3 @ 10.0 in

13.43 ft

SCHEMATIC DIAGRAM OF REINFORCED SLAB


GROUND FLOOR SLAB
PANEL NO: TARRACE

You might also like