VEGA T For Terminal Version 1.0 - 8639080e2e
VEGA T For Terminal Version 1.0 - 8639080e2e
Version TT and TD
Data sheet: DS/VE/0020/EN Ed.10-2018
VEGA T
Electronic counter for terminal Version 1.0
tor-indicating device to be used in measuring
ther than water (MID MI-005) approved by the
(France) with the Evaluation Certificate
haracteristics
one or two meters
terruptible and non-interruptible measuring
ng to MID European Directive
ation with the following extensions (Welmec
(Software separation):
ical part of the software is separated from the automation one;
VEGA T is a calculator-indicating device to be used in measuring systems for liquids other than water (MID MI-005) ap-
(Long term data storage):
proved
(250 deliveries) are savedbyand
thestored
notified
in abody LNE (France)
structure with MIDwith the Evaluation
criteria. Certificate
Data can also n.13954.
be downloaded
or directly consulted on the display thanks to a specific tool.
Metrology characteristics
(Legally relevant data transmission): delivery data can be sent to a printer via serial line with legally
ocol. • Management of one meter
• Management of 3 products
SOIL printers ST101 and ST201for interruptible and non-interruptible measuring systems according to MID European Directive
• Approved
• Software
parameters by password certification
(3 levels) with the
and Weight & following extensions (Welmec Guide 7.2):
Measure Switch
- Extension S (Software separation): the metrological part of the software is separated from the automation one;
modification function
- Extension L (Long term data storage): delivery data (250 deliveries) are saved and stored in a structure with MIDcriteria.
diagnosis Data can also be downloaded via serial line or directly consulted on the display thanks to a specific tool.
- Extension T (Legally relevant data transmission): delivery data can be sent to a PC, to a printing system or to a printer
via serial line with legally relevant protocol.
• Management of ISOIL printer ST500-M
acteristics • Access to all the parameters by password (3 levels) and Weight & Measure Switch
• Log parameters modification function
• Continuous self-diagnosis• Configurable counting inputs push-pull, open-
roof ATEX approved
ation ports: n° 2 EIA-RS232, collector
° 1 EIA-RS422/RS485, • n°6 Ex-ia digital inputs, fully programmable
graphic display Hardware characteristics • n°4 Ex-d digital inputs, fully programmable
ti-function membrane keyboard • n°12 power outputs, fully • n°4 programmable
Ex-d digital inputs, fully programmable
push-button • Ex-d explosion proof ATEX approved • n°7 power outputs, fully programmable
• Serial communication ports: n° 2 EIA-RS232, n°2 EIA- • n°4 digital outputs or programmable pulses outputs
RS485, n° 1 EIA-RS422/RS485, • n° 2 analog inputs 4÷20 mA (optional) for density ac-
• Backlighted LED graphic display quisition
• Numeric and multi-function membrane keyboard • n° 2 analog outputs 4÷20 mA (optional) for remote
• Configurable counting inputs push-pull, open- collector flow rate and temperature indication or analog value
• n°6 Ex-ia digital inputs, fully programmable control.
Functions
Functions
Density acquisition Base density (standard conditions) or observed density (ambient temperature) can be
acquired via 4÷20 mA input.
VEGA T calculates the density average value during product delivery.
Temperature VEGA T (with compensating function) enables calculation of product volume with reference to
compensation base temperature (Tb), usually 15°C or 20°C, for the following products:
(optional) • petrochemical products with configurable API compensation tables (6A, 6B, 6C, 24A, 24B,
53A, 53B, 53D ,54, 54A, 54B, 54D, 60A, 60B, 60D) and BRASIL table.
• ethanol products according to OIML R22 and NBR5992 tables.
• biofuels with PTB table for temperature compensation of minerals and biofuel mixtures.
Alternatively compensation with the ALFA cubic expansion coefficient can be used.
Operations
When in local mode VEGA T can manage product delivery according to the enabled functions and perform the
following operations:
• select product via keyboard or external selector
• select type of loading (top/bottom) via external selector
• check interlocks and signals
• set the preset
• start product delivery from keyboard or external button
• open selector/shut-off/ vapour recovery valves, and start pump according to the timing set in the pertaining parameters
• management of the loading process via preset valves. In this stage, besides product measurement, VEGA T per-
forms flow rate, temperature and automation control
• close the preset when the preset product quantity has been delivered
• close selector/shut-off/ vapour recovery valves, and stop pump according to the timing set in the pertaining parameters
• summarize data and print loading reports.
Delivery management
When in remote mode VEGA T is controlled by a TAS (Terminal Automation System) and once initialized it works
independently controlling product delivery by means of the devices it is connected to. The system can control the
following functions:
• identification of operator via pin code or badge and loading permission management
• delivery start and stop, method selection (top/bottom loading, automatic/semiautomatic), reset of quantity, den-
sity update
• enabling/disenabling meter
• alarm reset
• data acquisition (status)
• preliminary and final data summary
• download of product delivery data.
Remote control is achieved though serial communication with proprietary or ModBus RTU protocol.
Valves
VEGA T can manage different valve types:
• Two stages: two stages valve allows supply of the preset quantity by controlling the two solenoid valves (one for
Low flow and one for High flow). Flow rate values can be pre-set by acting mechanically on the valve while the
VEGA T manages low flow stage at the beginning of product delivery, high flow stage and low flow at the end of
flow rate in order to avoid splash phenomena and the formation of foam. The duration of the different phases can
be set in the specific parameters. Moreover the automatic final adjustment function can be used: if required, the
preset ends with a series of short valve openings until the exact preset value is reached.
• Multistep (digital valve): this valve not only allows managing of the initial and final low flow stage, but it also allows
for dynamic regulation of flow rate at pre-set value by acting on the solenoid valves (one NO and one NC). This
regulates the position of the valve diaphragm. This valve has a default high flow rate value and two lower high flow
rate values that can be controlled by two digital inputs. Flow rate can alternatively be set via serial line message.
• Analog (4÷20 mA): VEGA T can drive any valve with suitable hydraulic characteristics thanks to the 4÷20 mA signal.
Product delivery and flow rate values are managed in the same way as for digital valves.
Ticket printing
VEGA T can print two configurable tickets with a set of specific parameters via serial line protocols. Tickets can be
printed with the following ISOIL printers:
Each digital input can be programmed as “consent” for loading (interlock) or as signal linked to a specific function.
If the configuration is made as interlock, you can select:
Outputs
VEGA T has several outputs (see Technical Data table), each one can be associated to a specific function (see Pa-
rameters Manual).
Data type of pulses (volume, compensated volume and weight) and k factor (multiplication factor) can be defined
for each output.
4÷20 mA Analogue Inputs
Two 4÷20mA inputs can be configured to:
• receive actual product density.
Two types of input data can be acquired: density at Tb (base temperature) and density at Tamb (ambient temperature)
• receive the alpha cubic expansion coefficient
• receive alcoholic strength value.
4÷20 mA Analogue Outputs
Two 4÷20mA outputs can be configured to:
• send product temperature (actual or average)
• send product flow rate (actual or average).
Additive injection
VEGA T manages product additive injection :
• by connecting to ISOIL FlexiMix via RS485 serial line.
Up to 6 Fleximix can be managed, each of which can inject up to 6 additives at the same time. As a whole a
maximum of 6 additives can be managed.
VEGA T can:
- decide whether to inject additive(s) or not,
- select additives and their percentage,
- receive information about the quantity injected by FlexiMix,
- receive information about the alarms, run diagnostic and decide whether to continue/stop loading.
• by connecting to smart additive injection devices, receiving pulses according to the quantity and control the
hydraulic circuit with a dosing valve, piston or pump for product delivery according to the required percentage.
VEGA T allows you to control two separate devices with a maximum of four additives, each using the following
digital signals:
- n° 2 D/O (digital output) to select device
- n° 4 D/O (digital output) to select additive - n° 2 D/I (digital input) to acquire alarms.
By combination of different function modes up to 6 additives can be injected at the same time.
DS/VE/0015/EN
Dimensions
Dimensions Accessories
Accessories
Dimensions in mm • EM6422 pulse emitter
• ST101, ST500-M printers
• A class PT100 thermoresistance
• LFD-6 display
• SBR Serial Badge Reader
Code example: X 2 9 5 - 1 N X 3
Fixed value 2
Single meter 9
Fixed value 1
Fixed value N
Fixed value 3
DS/VE/0015/EN
Technical data
Technical data
Environmental features
Working temperature: -25 ÷ +55°C (-13÷131°F)
Storage temperature: -25 ÷ +65°C (-13÷149°F)
temperature probe:
4÷20 mA Inputs: n°2 4÷20 mA two wires, input resolution: 16 bits (65 536 points)
4÷20 mA Outputs: n°2 4÷20 mA two wires, output resolution: 16 bits (65 536 points)
n°4 current source externally powered outputs (5 ÷ 30 Vdc)
Digital outputs:
Imax=1 A each
Digital power outputs: n°7 of which:
• 3 mechanical relays (all versions)
• 4 Vac/Vdc solid state relays (according to VEGA T power supply)
Serial communication: 2 lines RS485 two wires
2 lines RS232 (RX, TX, COM)
1 line RS422/485 four wires
ATEX: II 2(1) G Ex d [ia Ga] ib IIB T6 Gb - INERIS 05ATEX0034X approval
Mechanical protection: IP66