0% found this document useful (0 votes)
98 views

Quotation Diesel Tank

This document provides specifications for aboveground diesel fuel storage tanks. It describes the design, fabrication, fittings, dimensions, and warranty of NAFFCO certified primary containment tanks for fuel storage. The tanks are UL certified and meet NFPA standards for fuel storage and fire pump applications.

Uploaded by

Zeeshan hyder
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
98 views

Quotation Diesel Tank

This document provides specifications for aboveground diesel fuel storage tanks. It describes the design, fabrication, fittings, dimensions, and warranty of NAFFCO certified primary containment tanks for fuel storage. The tanks are UL certified and meet NFPA standards for fuel storage and fire pump applications.

Uploaded by

Zeeshan hyder
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

www.naffco.com 2 CAT. NO.

: NF/AG-DT/CERT/12/19
ABOVEGROUND FUEL TANK
NAFFCO certified primary containment tank offers you a openings to facilitate quality service at field. All tanks
reliable solution for your fuel storage requirements. Design are provided with openings for filling, connecting to
and fabrication of these tanks are done as per UL standard diesel engine fuel system, fuel return line connection
(UL 142), and installation and use shall be in accordance and drain. Lifting lug, provided on the top center of the
with NFPA 30. Each tank is subjected to thorough structural tank, facilitates easy transportation and installation. These
inspections and leakage test as specified by the design tanks are also provided with opening for connecting to a
standard. The tanks that successfully pass the inspection direct reading fuel level gauge that is supplied as part of
and test are labelled as per UL specifications confirming standard fire pump package.
their UL certification. These cylindrical, horizontally
mounted, tanks are provided with necessary fittings and

DIESEL TANK
FEATURES
• Meets NFPA 30 requirements.
• Sized as specified by NFPA 20 for fire pump
applications.
• Designed and Fabricated in accordance with
UL 142 (Steel Aboveground Tanks for Flam-
mable and Combustible Liquids) standard .
• Tested for tightness against leakage.
• Top quality fittings and fabrication materi-
als.
• Sturdy lifting lug and legs.
• Vent opening to prevent build-up of pressure or
vacuum inside the tank during filling, emptying or
due to atmospheric temperature changes.
• Approved welding process.

Applicable welding processes are Gas Metal Arc Welding (GMAW) and/or Shielded Metal Arc Welding
(SMAW). Shell, Dish Head and Lift Lug material is carbon steel, ASTM A36 and legs shall be of carbon
steel pipe, ASTM A53. Standard height for the tank leg is minimum 500 mm.

NOTES WARRANTY
• Fuel tank outlet must be even with engine fuel pump cen- The subject tank is warranted by
terline. NAFFCO to be free from defects in
• Fuel tank should be located as close to engine as possi- manufacturing, workmanship and
ble. materials. NAFFCO Tank will repair or
• Fuel tank should have a slope of 6 mm per foot towards replace, at its sole discretion F.O.B.
drain plug. factory, within a period of one year
• The usable volume of the fuel tank is 90% of the total fuel after date of shipment, any item of our
tank volume. manufacture.
• All pipe lines should be inspected thoroughly to ensure
that joints are leak free.
• Fuel tank should be cleaned periodically and fuel level
should be checked weekly for fire pump applications.

www.naffco.com 3 CAT. NO. : NF/AG-DT/CERT/12/19


Vent Assy.
Inlet

D
1 4 5 5
Lift Lug

Expansion Volume 5%

Fuel to Engine
Sump Volume 5%

3
Fuel from Engine

Drain

Ø2.5" Removable Leg


Minimum 500mm

150 150
W L

DIESEL TANK FRONTVIEW DIESEL TANK ELEVATION

FITTINGS
FITTINGS
ITEM DESCRIPTION MATERIAL QTY
1 1/2” Nipple Carbon Steel 2
2 1/2” NPT Ball Valve Brass 1
3 1/2” NPT Plug for Drain Carbon Steel 1
4 4” Nipple for Emergency Vent Carbon Steel 1
5 2” Nipple for Filling Carbon Steel 2

DIMENSIONS
DIMENSIONS
CAPACITY (GALLONS) LENGTH (L) DIAMETER (D) WIDTH (W)
70 1065 600 430
100 850 800 575
150 1275 800 575
200 1085 1000 720
250 1355 1000 720
310 1465 1070 768.5
350 1655 1070 768.5
400 1890 1070 768.5
450 1690 1200 900
500 1875 1200 900
600 2245 1200 900
750 2805 1200 900

ALL DIMENSIONS ARE IN MM UNLESS OTHERWISE INDICATED

www.naffco.com 4 CAT. NO. : NF/AG-DT/CERT/12/19


ABOVEGROUND FUEL TANK
NAFFCO certified primary containment tank offers you a openings to facilitate quality service at field. All tanks
reliable solution for your fuel storage requirements. Design are provided with openings for filling, connecting to
and fabrication of these tanks are done as per UL standard diesel engine fuel system, fuel return line connection
(UL 142), and installation and use shall be in accordance and drain. Lifting lug, provided on the top center of the
with NFPA 30. Each tank is subjected to thorough structural tank, facilitates easy transportation and installation. These
inspections and leakage test as specified by the design tanks are also provided with opening for connecting to a
standard. The tanks that successfully pass the inspection direct reading fuel level gauge that is supplied as part of
and test are labelled as per UL specifications confirming standard fire pump package.
their UL certification. These cylindrical, horizontally
mounted, tanks are provided with necessary fittings and

DIESEL TANK
FEATURES
• Meets NFPA 30 requirements.
• Sized as specified by NFPA 20
for fire pump applications.
• Designed and Fabricated
in accordance with UL 142
(Steel Aboveground Tanks for
Flammable and Combustible
Liquids) standard
• Tested for tightness against
leakage.
• Top quality fittings and fabri-
cation materials.
• Sturdy lifting lug and legs.
• Vent opening to prevent build-
up of pressure or vacuum inside
the tank during filling, emptying or
due to atmospheric temperature changes.
• Approved welding process.

Applicable welding processes are Gas Metal Arc Welding (GMAW) and/or Shielded Metal Arc Welding
(SMAW). Shell, Dish Head and Lift Lug material is carbon steel, ASTM A36 and legs shall be of carbon
steel pipe, ASTM A53. Standard height for the tank leg is minimum 500 mm.

OPTIONS & ACCESSORIES WARRANTY TYPICAL USES


Stairs & Filling Platform The subject tank is warranted by • Emergency Fuel Storage
Walkway(s) with Handrails NAFFCO to be free from defects in • Diesel Generator Storage
Emergency Vent(s) manufacturing, workmanship and • Secondary Fuel Storage
Exterior epoxy primer coat materials. NAFFCO Tank will repair
or replace, at its sole discretion
F.O.B. factory, within a period of one
year after date of shipment, any item
of our manufacture.

www.naffco.com 5 CAT. NO. : NF/AG-DT/CERT/12/19


L

1 4 5
5
LEVEL INDICATOR LA DDER
LIFT LUG LIFT LUG

FUEL TO SUPPLY

300 L1 L2 300 2
3 D
1
SPECIAL LEG SUPPORT

FITTINGS
FITTINGS
ITEM DESCRIPTION MATERIAL QTY
1 1/2” Nipple Carbon Steel 2
2 1/2” NPT Ball Valve Brass 1
3 1/2” NPT Plug for Drain Carbon Steel 1
4 4” Nipple for Emergency Vent Carbon Steel 1
5 2” Nipple for Filling Carbon Steel 2

DIMENSIONS
DIMENSIONS
CAPACITY (GALLONS) LENGTH (L) DIAMETER (D) WIDTH (W) LEG DISTANCE ( L1=L2)
1000 2100 1600 1400 750
1500 3145 1600 1400 1275.5
2000 2970 1900 1700 1185
ALL DIMENSIONS ARE IN MM UNLESS OTHERWISE INDICATED

www.naffco.com 6 CAT. NO. : NF/AG-DT/CERT/12/19


www.naffco.com 7 CAT. NO. : NF/AG-DT/CERT/12/19