Op 6
Op 6
Dismantling of existing/ damaged structures like culverts, bridges, retaining walls comprising of
masonry, cement concrete, wood work, steel work by manual/ mechanical means and sorting the
dismantled material, disposal of unserviceable material and stackting the serviceable material with
all lifts and lead up to 1000 meters including scrapping and removing concrete from MS rods,
preparation and erection of platform where necessary, carrying, all sorts of handling, stacking the
same properly after clearing, leveling and dressing the site and clearing the river/canal bed, etc. all
2 complete as per direction of the E-I-C. Cost of conveying, loading, transportation of unserviceable Cum 2566.45 0.4 1026.58
material accumulated during dismantling operation is included in this unit rate. The unserviceable
material must be disposed at a safe place outside the site premises with minimum traffic disruption
and the procuring entity will not provide any environmentally safe place for disposing the
unserviceable materials.
RCC works. Case I: By Manual Means
Sand filling in foundation trenches and plinth with sand having minimum F.M. 0.5 in 150 mm layers
including leveling, watering and compaction to achieve minimum dry density of 95% with optimum
5.02.08.1 3 moisture content (Modified proctor test) by ramming each layer up to finished level as per design Cum 1088.00 5.402625 5878.06
supplied by the design office only, all complete and accepted by the Engineer-in-charge. [PWD
02.10.1]
Brick works with first class bricks with cement sand (F.M. 1.2) mortar (1:4) in exterior walls including
filling the interstices with mortar, raking out joints, cleaning and socking the bricks at least for 24
hours before use and washing of sand, necessary scaffolding, curing at least for 7 days etc. all
5.04.03 4 complete including cost of water, electricity and other charges (measurement to given as 250 mm Cum 10097.00 6.75 68178.41
width for one brick length and 375 mm for one brick and a half brick length) accepted by the
Engineer-in-charge. (Cement: CEM-II/B-M) In ground floor (PWD 04.3)
125 mm brick works with first class bricks with cement sand (F.M. 1.2) mortar (1:4) and making bond
with connected walls including necessary scaffolding, raking out joints, cleaning and soaking the
bricks for at least 24 hours before use and washing of sand, curing at least for 7 days in all floors
5.04.16 5 including cost of water, electricity and other charges etc. all complete and accepted by the Engineer- sqm 1408.00 73.17 103023.36
in-charge. (Cement: CEM-II/B-M) In ground floor (PWD 04.16)
Mass concrete (1:2:4) in foundation or in floor with cement, sand (F.M. 1.2) and picked jhama brick
chips including breaking of chips, screening, mixing, laying, compacting to required level and curing
for at least 7 days including the supply of water, electricity, costs of tools & plants and other charges
6 etc. all complete and accepted by Engineer-in-charge. (Cement: CEM-II/B-M) [PWD 03.5] Cum 10504.00 0.79 8257.13
Mass concrete in foundation (1:2:4) with brick chips and local sand of F.M. 1.2. [PWD 03.5.1]
RCC WORKS: 1:1.5:3( measured on gross concrete section) (f'c = 25MPa, minimum f'cr = 33.5 MPa in
nominal mix 1 : 1.5 : 3), with stone chips
(100% sand of F.M. 2.2) Reinforced cement concrete works with minimum cement content relates to
mix ratio 1:1.5:3 having maximum water cement ratio = 0.40 and minimum f'cr = 33.5 MPa,
satisfying a specified compressive strength f’c = 25 MPa at 28 days on standard cylinders as per
standard practice of Code ACI/BNBC/ASTM, Cement conforming to BDS EN-197-1-CEM-I, 52.5N (52.5
MPa) / ASTM-C 150 Type – I, best quality Sylhet sand or coarse sand of equivalent F.M. 2.2 and 20
mm down well graded stone chips conforming to ASTM C-33 (Aggregate grading as per table shown
in technical specification), conducting necessary tests, making and placing shutter in position and
5.05.03.03 7 maintaining true to plumb, making shutter water-tight properly, placing reinforcement in position; Cum 14748.00 2.18 32102.34
mixing with standard mixer machine with hopper, fed by standard measuring boxes, casting in forms,
compacting by vibrator machine and curing at least for 28 days, removing centering-shuttering after
specified time approved; including cost of water, electricity, other charges etc. all complete,
approved and accepted by the Engineer-in-charge. (Rate is excluding laboratory test fees, the cost of
reinforcement and its fabrication, placing, binding etc. and the cost of shuttering & centering) (PWD
07.3) Floor / roof slab, T-beam, L-beam and rectangular beam, tie beam, lintel, stair case slab and
steps etc. upto ground floor (PWD 07.3.3)
FORM WORK (Steel) :Centering and shuttering, including strutting, propping etc. (The formwork
must be rigid enough both in and out of plane, to make the concrete surface true to the designed
5.05.11.07 8 shape and size by using necessary MS sheets of minimum 16 BWG, angles of minimum size 40 mm x Cum 597.00 19.059375 11378.45
40 mm x 5 mm, flat bars etc.) and removal of form for: (PWD 07.12) Floor and roof slab up to ground
floor (PWD 07.12.7)
Item code Sl. No. Item Description Unit Rate Quantity Amount Remarks
Supplying, fabrication and fixing to detail as per design : ribbed or deformed bar reinforcement
(excluding laboratory test fees) for Reinforced concrete, produced and marked in accordance with
BDS ISO 6935-2:2016 (or standard subsequently released from BSTI) including straightening and
cleaning rust, if any, bending and binding in position with supply of G.I. wires,conducting necessary
laboratory tests etc. (excluding splices or laps) complete in all respect and accepted by the Engineer-
in-charge (Measurement shall be recorded only on standard mass per unit length of bars, while dia
of bars exceeds its standard) . (PWD 08.1) Grade 400 (B400DWR / B420DWR: complying BDS ISO
5.06.01.02 9 6935-2:2016 / ASTM A615) ribbed or deformed bar produced and marked according to Bangladesh Kg 121.00 473.8998325 57341.88
standard, with minimum yield strength, fy (ReH)= 400 MPa but fy not exceeding 480 MPa and
whatever is the actual yield strength within allowable limit as per BNBC/ ACI 318, the ratio of
ultimate tensile strength fu to yield strength fy, shall be at least 1.25 and minimum elongation after
fracture and minimum total elongation at maximum force is 17% and 8% respectively : up to ground
floor. . (PWD 08.1.2)
Minimum 12 mm thick cement sand (F.M. 1.2) plaster (1:4) with fresh cement to outer surface of
wall, finishing the corner and edges including washing of sand, cleaning the surface, curing at least
5.12.02 10 for 7 days, cost of water, electricity, scaffolding and other charges etc. all complete in all respect as sqm 335.00 73.17 24511.95
per drawing and accepted by the Engineer-in-charge. (Cement: CEM-II/B-M) ground floor. [PWD
15.1.2]
Minimum 6 mm thick cement sand (F.M. 1.2) plaster (1:4) with fresh cement to ceiling, R.C.C.
columns, beams, surface of stair case, sunshades, cornices, railings, drop wall, louvers, fins and
finishing the corners and edges including washing of sand, cleaning the surface, curing at least for 7
5.12.06 11 sqm 301.00 12.38 3725.44
days, cost of water, electricity, scaffolding and other charges etc. all complete in all respect as per
drawing and accepted by the Engineer-in-charge. (Cement: CEM-II/B-M) ground floor. [PWD 15.5]
Interior super premium acrylic emulsion painting (odorless) of approved best quality and colour
delivered from authorized local agent of the manufacturer in a sealed container; applying to interior
wall and ceiling with surface preparation including cleaning drying, making free from dirt, grease,
wax, removing all chalked and scaled materials, fungus, mending good the surface defects using sand
paper and necessary scaffolding; applying necessary interior sealer of specified brand on prepared
5.16.03.3 12 surface; then applying necessary interior putty of specified brand for levelling, spot filling, crack filling sqm 314.00 85.55 26861.72
and cutting by sand paper/zero water paper, finally applying 2 coats of interior emulsion paint
spreading by brush/roller/spray & necessary scaffolding etc. upto desired finishing, elapsing specified
time for drying or recoating; all complete in all floors accepted by the Engineer-in-charge. [PWD
16.2.3]
38 mm thick artificial patent stone (1:1.5:3) flooring with cement, best quality coarse sand (50%
quantity of Sylhet sand or coarse sand of equivalent F.M. 2.2 and 50% best quality local sand of FM
1.2) and 12 mm down well graded stone chips, laying the concrete in alternate panels, compacting
5.13.06 13 and finishing the top with neat cement and curing at least for 7 days in all floors including cost of sqm 782.00 12.376875 9678.72
water, electricity and other charges etc. all complete and accepted by the Engineer-in-
charge.(Cement: CEM-II/B-M) In ground floor (PWD BW 04.31)
Supplying, fitting and fixing country made glazed wall tiles complying BDS ISO 13006: 2015,
irrespective of color &/or design, with 20 mm thick cement sand (F.M. 1.2) mortar (1:3) base and
raking out the joints with white cement including cutting, laying and hire charge of machine and
5.15.06.2 14 finishing with care etc. including cost of water, electricity and other charges complete in all respect sqm 1592.00 30.3 48237.60
and accepted by the Engineer-in-charge. (Cement: CEM-II/B-M). In ground floor (PWD BW 06.6) Wall
tiles more than 250 mm x 330 mm & less than or equal to 250 mm x 400 mm in sizes.
Supplying, fitting and fixing country made homogeneous matt finished/ rustic floor tiles complying
BDS ISO 13006: 2015, water absorption ≤ 0.5%, modulus of rupture (MOR) ≥ 27 N/mm2, irrespective
of color &/or design, with 20 mm thick cement sand (F.M. 1.2) mortar (1:4) base and raking out the
5.15.03.2 15 joints with white cement including cutting and laying the tiles in proper way and finishing with care sqm 1943.00 7.51 14593.75
etc. all complete and accepted by the Engineer-in-charge. (Cement: CEM-II/B-M) In ground floor
(PWD BW 06.3)
Matt or rustic floor tiles of size 600 mm x 600 mm and below.
Supplying, fitting and fixing of the best quality any sizes uPVC plastic door shutter with frame having
specific gravity of 1.35 - 1.45, panel wall thickness 1.7 mm-2.2 mm, shutter/panel thickness 37.5
mm & weighing 17.25 kg/m2 and other physical, chemical, thermal, fire resistivity properties etc. as
per BSTI approved manufacturer standards and ASTM, BS/ISO/IS standards of different sizes uPVC
plastic door shutter with uPVC plastic frame (frame size:150mm x 62.50mm) fitting - fixing in brick
wall/ R.C.C wall with at least 3 Nos. SS hinges by min 64 Nos. Ø 3.17 mm and 3.97 mm 12.7 mm long
5.08.27 16 sqm 3774.00 0.315 1188.81
rivets, 12 nos. 25.4 mm SS screws, Ø 9.38 mm, 150 mm long SS tower bolts 2 nos., 146 mm SS handle
by rivet 6 Nos., G.I inner joint, 234.95 mm x 127 mm clamp, 76.2 mm x 57.15 mm, 6 Nos. GI clamp, 2
nos. outer GI joint clamp making necessary grooves and mending good the damages, finishing,
curing, carrying the same to the site and local carriage etc. complete in all respect and accepted by
the Engineer-in-charge.[PWD 22.12]
Item code Sl. No. Item Description Unit Rate Quantity Amount Remarks
Supplying, fitting and fixing of aluminium sliding window as per the U.S. Architectural Aluminium
Manufacturer’s Association (AAMA) standard specification and BDS 1879:2014 having minimum 1.2
mm thick outer bottom (size 75.50 mm, 32mm,0.605 kg/m ), minimum 1.2 mm thick outer top (size
75.50 mm, 28.50 mm0.705 kg/m), minimum 1.2 mm thick shutter top (size 33 mm.26.80 mm,0.42
kg/m), minimum 1.2 mm thick shutter bottom (size 60mm, 24.40 mm,0.589 kg/m), minimum 1.2 mm
thick outer side (size 75.50 mm,19.90 mm,0.52 kg/m), minimum 1.2 mm thick shutter lock (size
49.20 mm 25.80 mm,0.543 kg/m) and minimum 1.2 mm thick inter lock (size 34.40 mm, 32.13
mm,0.562 kg/m) sections all aluminium members will be anodized to aluminium
bronze/silver/ss/black colour with a coat not less than 15 micrones in thickness or powder coated to
5.11.07.2.1 17 any colour with a coat not less than 25 micrones in thickness and density of 4 mg per square cm etc. sqm 5190.00 0.72 3736.80
including all accessories like sliding door key lock, sliding door wheel, sliding door mohiar, sliding
door neoprene, bolts and nuts including sealants, keeping provision for fitting 5 mm thick glass
including labour charge for fitting of accessories, making grooves and mending good damages,
carriage, and electricity complete in all respect as per drawing and accepted by the Engineer-in-
charge. [PWD 14.7]
Size up to: 900 mm x 1400 mm [PWD 14.7.2]
Anodized to any colour [PWD 14.7.2.1]
Supplying, fitting and fixing in Aluminium door frames, windows, partitions and curtain wall
distortion free glass of approved quality and shade including cost of fitting fixing all necessary
5.11.16.03 18 accessories etc. complete in all respect as per drawing and accepted by the Engineer-in-charge. sqm 1229.00 0.72 884.88
[PWD 14.16]
5 mm thick clear glass [PWD 14.16.1.2.1]
Supplying, fitting, fixing window grills of any design made with 25 mm x 6 mm F.I. bar @ 100 mm c/c
as inner section but no outer frame; including fabrication, welding, cost of electricity workshop
charges, labour charges for fitting and fixing grills in position, local carriage charges, cutting grooves,
5.10.04.2 19 mending good the damages, tools and plants, finished with anti-corrosive painting (Red-oxide) etc. sqm 2492.00 0.72 1794.24
complete for all floors accepted by the Engineer-in-charge. (Total weight per sqm should be approx
16 kg and add or deduct @ Tk. 100.00 for each kg/sqm excess or less respectively) [PWD 13.4.2]
Supplying, fitting and fixing window grills of any design made of 20 mm x 3 mm mild steel section @
100 mm c/c with outer frame of 25 mm x 6 mm F.I. bar including fabrication, welding, cost of
electricity workshop charges, carriage, cutting grooves, mending good the damages, tools and
5.20.15 20 plants, finished with anti-corrosive painting (Red-Oxide) etc complete for all floors and accepted by sqm 1959.00 3.24 6347.16
the Engineer-in-charge. (Total weight per sqm should be approx 10.00 kg. and add or deduct @ Tk.
100.00 for each kg/sqm excess or less respectively) [PWD 13.2]
Supplying, fitting and fixing stainless steel railing on inner side of stair with 2 mm thick 62 mm dia SS
pipe for hand-rail (50mm space from wall), fitting and fixing by a SS pipe holder @ 1200 mm c/c
welding with 65 mm x 55 mm x 6 mm SS base plate and fitting base plate on RCC or Brick wall by SS
5.19.24.1 21 m 2288.00 6.5 14872.00
Royel Bolt including welding, bending, fabricating, polishing all complete as per drawing, desing and
specification etc all complete in all respect and accepted by Engineer-in-charge. [PWD 20.12.1]
5.27.097 22 Providing 37 mm dia and 600 mm long PVC spout[PWD 32.97] each 253.00 2 506.00
Supplying, fitting and fixing 18mm thick marble Name plate including cost of materials, labour, form
1.16 23 work, engraving neatly the approved Sample given by the engineer etc. complete as per drawings sqm 8500.16 1.08 9180.17
and direction of the Engineer-in-charge.
Supplying, fitting and fixing stainless steel (SS) stair railing of standard height with 2 mm thick 62 mm
dia SS pipe for hand-rail, 2 mm thick 40 mm dia 5 nos vertical SS pipes in each flight, 1.5 mm thick 20
5.19.11 24 mm dia 5 nos horizontal SS pipes as per drawing, design including carrying, polishing, fabricating, sqm 7786 6 46716.00
welding and fixing with tread by 25 mm long royal bolt etc.all complete and accepted by the
Engineer-in-charge. [PWD 20.8.1]
Sub Total = 504,485.40
Part-2: Cost of Sub-Structure
Earth work in excavation in all kinds of soil for foundation trenches including layout, providing center
lines, local bench-mark pillars, levelling, ramming and preparing the base, fixing bamboo spikes and
marking layout with chalk powder, providing necessary tools and plants, protecting and maintaining
the trench dry etc., stacking, cleaning the excavated earth at a safe distance out of the area enclosed
by the layout etc. all complete and accepted by the Engineer-in-charge, subject to submit method
5.02.01.2 25 cum 168 0.15 24.94
statement of carrying out excavation work to the Engineer-in-charge for approval. However,
engineer’s approval shall not relieve the contractor of his responsibilities and obligations under the
contract. [PWD 02.1] Earthwork in excavation in foundation trenches up to 1.5 m depth and
maximum 10 m lead [PWD 02.1.2]
P&B: Pumping and bailing out water from the interior of any foundation enclosure of work site with
all leads and lifts including supply, operation and maintenance of requisite number of water pumps,
arrangements for protection of ring bundh and side slopes of foundation pit against erosion or
4.05.03 26 washout etc. It should be carried out in such a manner as to preclude the possibility of the hour 474 0 0.00
movement of water through or alongside any concrete being placed, etc. all complete as per
direction of E-I-C. [PWD 2.2]
One layer brick flat soling in foundation or in floor with first class/picked jhama bricks (BDS 208)
5.03.01 27 including preparation of bed and filling the interstices with local sand, leveling etc. complete and sqm 636 0.3125 198.75
accepted by the Engineer-in-charge [PWD 03.1.1]
Sand filling on the prepared foundation bed with sand of specified FM in layers not more than
150mm thick including necessary carriage, leveling, watering and ramming to achieve minimum dry
4.06.01.01 28 density (MDD) of 95% STD compaction with optimum moisture content (OMC) by ramming each cum 1071 0.0625 66.94
layer up to finished level as per direction of E-I-C.
Sand of Minimum FM 0.8
Item code Sl. No. Item Description Unit Rate Quantity Amount Remarks
Damp proof course (DPC) (1:1.5:3) of cement concrete with cement, sand and picked jhama brick
chips or stone chips including breaking of chips, screening, centering, shuttering, casting, curing and
finishing with a coat of bitumen including the supply of water, electricity, costs of tools & plants and
5.03.04.1 27 other charges etc. all complete and accepted by Engineer-in-charge. (Cement: CEM-II/B-M) [PWD sqm 1597 0.5 798.50
03.6]
75 mm thick damp proof course (1:1.5:3) with cement, Sylhet sand (F.M. 2.2) and stone chips. [PWD
03.6.1]
Brick works with first class bricks with cement sand (F.M. 1.2) mortar (1:4) in foundation and plinth,
filling the joints/interstices fully with mortar, racking out the joints, cleaning and soaking the bricks
5.04.1 28 at least for 24 hours before use and curing at least for 7 days etc. all complete including cost of cum 9140 0 0.00
water, electricity and other charges and accepted by the Engineer-in-charge. (Cement: CEM-II/B-M)
(PWD 04.1)
RCC WORKS: 1:2:4 (measured on gross concrete section) (f 'c = 22 MPa, minimum f 'cr = 30.5 MPa in
nominal mix 1:2:4), with stone chips (100% sand of F.M. 2.2 )
Reinforced cement concrete works with minimum cement content relates to mix ratio 1:2:4 having
maximum water cement ratio = 0.40 and minimum f'cr = 30.5 MPa, satisfying a specified
compressive strength f'c = 22 MPa at 28 days on standard cylinders as per standard practice of Code
ACI/BNBC/ASTM, cement conforming to BDS EN-197-1-CEM-I, 52.5N (52.5 MPa) / ASTM-C 150 Type
– I, best quality Sylhet sand or coarse sand of equivalent F.M. 2.2 and 20 mm down well graded
stone chips conforming to ASTM C-33 (Aggregate grading as per table shown in technical
specification), conducting necessary tests, making and placing shutter in position maintaining true to
5.05.02.02 29 plumb, making shutter water-tight properly, placing reinforcement in position; mixing in standard cum 14487 0 0.00
mixer machine with hopper fed by standard measuring boxes, casting in forms, compacting by
vibrator machine and curing at least for 28 days, removing centering-shuttering after specified time
approved; including cost of water, electricity,other charges etc. all complete, approved and accepted
by the Engineer-in-charge. (Rate is excluding laboratory test fees, the cost of reinforcement and its
fabrication, placing, binding etc. and the cost of shuttering & centering) (PWD 07.2.)
Pedestals, column, column capital, lift wall and RCC wall, raft/mat, floor slab and foundation beam up
to ground floor (PWD 07.2.2)
FORM WORK (Steel) :Centering and shuttering, including strutting, propping etc. (The formwork
must be rigid enough both in and out of plane, to make the concrete surface true to the designed
5.05.11.07 30 shape and size by using necessary MS sheets of minimum 16 BWG, angles of minimum size 40 mm x Cum 597.00 0 0.00
40 mm x 5 mm, flat bars etc.) and removal of form for: (PWD 07.12) Floor and roof slab up to ground
floor (PWD 07.12.7)
Supplying, fabrication and fixing to detail as per design : ribbed or deformed bar reinforcement
(excluding laboratory test fees) for Reinforced concrete, produced and marked in accordance with
BDS ISO 6935-2:2016 (or standard subsequently released from BSTI) including straightening and
cleaning rust, if any, bending and binding in position with supply of G.I. wires,conducting necessary
laboratory tests etc. (excluding splices or laps) complete in all respect and accepted by the Engineer-
in-charge (Measurement shall be recorded only on standard mass per unit length of bars, while dia
of bars exceeds its standard) . (PWD 08.1)
5.06.01.02 31 Grade 400 (B400DWR / B420DWR: complying BDS ISO 6935-2:2016 / ASTM A615) ribbed or Kg 121 0 0.00
deformed bar produced and marked according to Bangladesh standard, with minimum yield
strength, fy (ReH)= 400 MPa but fy not exceeding 480 MPa and whatever is the actual yield strength
within allowable limit as per BNBC/ ACI 318, the ratio of ultimate tensile strength fu to yield strength
fy, shall be at least 1.25 and minimum elongation after fracture and minimum total elongation at
maximum force is 17% and 8% respectively : up to ground floor. . (PWD 08.1.2)
Supplying and laying uPVC pipe for for underground including fitting, fixing etc. all complete
7.44.1 32 approved and accepted by the Engineer- in- charge. 150 mm dia with wall thickness 4.5 mm - 6.6 mm m 1416 10 14160.00
uPVC pipe (PWD BW 26.44.1)
Supply, fitting & fixing of 600 mm dia C.I. man hole cover etc. all complete approved by the Engineer-
6.11.19 33 each 1819 0 0.00
in- charge. [PWD 26.69]
Construction of masonry inspection pit with 250 mm thick brick work in cement mortar (1:4)
including necessary earth work, side filling and one layer brick flat soling, 75 mm thick (1:3:6) base
concrete for making invert channel and 12 mm thick (1:2) cement plaster with neat finishing etc. all
7.70.4 34 complete up to a depth of 700 mm approved and accepted by the Engineer- in- charge. each 4683 ১ 4683.00
Master-pit of Size: Clear 600 mm x 600 mm and average 1000 mm depth for Septic tank. (PWD BW
26.70.4)
Construction and placement M.H. cover with locking/unlocking arrangement including necessary
earth work, side filling, shuttering, curing, cement plaster (1:4) with neat finishing on edges and top
7.71.1 35 etc. all complete approved and accepted by the Engineer- in- charge. 900 mm x 900 mm x 75 mm each 1361 ১ 1361.00
R.C.C. pit cover (PWD BW 26.71.1)
Minimum 12 mm thick cement sand (F.M. 1.2) plaster with neat cement finishing to dado with
cement (1:4) up to 150 mm including washing of sand, finishing the edges and corners and curing at
5.12.04 36 least for 7 days, cost of water, electricity, scaffolding and other charges etc. all complete in all sqm 395 0 0.00
respect as per drawing and accepted by the Engineer-in-charge. (Cement: CEM-II/B-M) ground floor.
[PWD 15.3]
Supplying and laying of single layer polythene sheet weighing one kilogram per 6.5 square meter in
5.03.05 37 floor or any where below cement concrete complete in all respect and accepted by Engineer-in- sqm 47 ০ 0.00
charge. [PWD 03.7]
Item code Sl. No. Item Description Unit Rate Quantity Amount Remarks
Construction of soak well of different sizes (as per detail drawing attached in annexure) (medium and
large sizes) with 250 mm thick solid brick work and 250 mm honey comb brick work with cement
mortar (1:6) as per design over R.C.C. (1:2:4) well curb with 1% reinforcement up to the depth as per
drawing with 450 mm dia water sealed heavy type. C.I. manhole cover with locking arrangement,
filling the well up to the required depth with graded khoa including supplying and fabricating M.S.
7.76.2 38 rod, casting, curing including necessary earth work in excavation, side filling and bailing out water each 137509 1 137509.00
including cost of all materials etc. all complete as per drawing, design approved and accepted by the
(Rate is including cost of reinforcement and its fabrication, binding and placing) Engineer- in- charge.
100 users (PWD BW 26.76.2)
Supplying, fitting and fixing of Bangladesh pattern, long pan with foot-rest. The sanitary ware shall
conform BDS1162:2014. The glaze shall be thoroughly fused to body. The minimum thickness of
body at any section shall be 5 mm. When assembled together and when examined from a distance
of 60 cm, the outer surface shall not show to the unaided eye, blemishes or defects in excess of
those listed in BDS standard. The mean value of water absorption shall not be greater than 0.5% of
the ware when dry. When tested with chemical solutions (Acetic acid, Citric acid, Detergent,
Hydrochloric acid, Sodium hydroxide, Sodium stearate and Sulfuric acid of various strength) as per
BDS1162:2014 procedure, none of the test pieces should suffer any loss of reflectivity on the glaze.
There shall be no crazing and no stain on the ware. The materials used for making glaze shall not
contain lead compound. In case of certain coloring oxides used for making colored glaze, the lead
content, if any, shall not exceed 5 percent of the weight of the glaze materials. Appliances shall be
7.07.2 40 each 2239 0 0
clearly and indelibly marked at a prominent place, visible even after the appliances are installed with
the following: a) manufacturer’s name and/or registered trademark, b) the number of Bangladesh
standard and c) country of origin. Each product shall also be marked with the BSTI Certification
Mark.
The fixure should be placed in position preparing the base of pan with cement mortar (1:4) and with
wire mesh or rods, if necessary in all floors including making holes wherever required and mending
good the damages and fitting, fixing, finishing etc. complete with all necessary fittings and
connections approved and accepted by the Engineer- in- charge.
Approx. 530 X 400 X 230 mm size, minimum 11.0 kg of weight (PWD BW 26.07.2)
Supplying, fitting and fixing of country made glazed vitreous W/H wash basin excluding pedestal. The
sanitary ware shall conform BDS1162:2014. The glaze shall be thoroughly fused to body. The
minimum thickness of body at any section shall be 5 mm. When assembled together and when
examined from a distance of 60 cm, the outer surface shall not show to the unaided eye, blemishes
or defects in excess of those listed in BDS standard. The mean value of water absorption shall not be
greater than 0.5% of the ware when dry. When tested with chemical solutions (Acetic acid, Citric
acid, Detergent, Hydrochloric acid, Sodium hydroxide, Sodium stearate and Sulfuric acid of various
strength) as per BDS1162:2014 procedure, none of the test pieces should suffer any loss of
reflectivity on the glaze. There shall be no crazing and no stain on the ware. The materials used for
making glaze shall not contain lead compound. In case of certain coloring oxides used for making
colored glaze, the lead content, if any, shall not exceed 5 percent of the weight of the glaze
7.12.02 41 each 3811 1 3811
materials. Appliances shall be clearly and indelibly marked at a prominent place, visible even after
the appliances are installed with the following: a) manufacturer’s name and/or registered trademark,
b) the number of Bangladesh standard and c) country of origin. Each product shall also be marked
with the BSTI Certification Mark.
The fixure should be placed in position with heavy type C.I. Brackets. 30 mm dia PVC waste water
pipe with brass coupling (not exceeding 750 mm in length), basin waste with chain plug including
making holes in walls and floors and fitting with wall, screws and mending good the damages,
finishing etc. all complete approved and accepted by the Engineer-in-charge.
Over Counter: Approx. 445X 345 mm, minimum weight 7.0 kg (PWD BW 26.12.2)
Supplying, fitting and fixing of best quality toilet paper holder of standard size including making holes
in walls and mending good the damages with cement mortar (1:4) etc. all complete approved and
7.23.1 42 each 293 0 0
accepted by the Engineer- in- charge. PVC toilet paper holder (PWD BW 26.23.1)
Item code Sl. No. Item Description Unit Rate Quantity Amount Remarks
Supplying, fitting and fixing of standard size country made soap tray including making holes in walls
and mending good the damages with cement mortar (1:4) etc. all complete approved and accepted
7.24.1 43 each 150 1 150
by the Engineer- in- charge. PVC soap tray (PWD BW 26.24.1)
Supplying, fitting and fixing of best quality country made 12 mm bib cock made from copper or
copper alloy, chromium plated.
The faucet conforms BDS EN 200:2009. The faucet tap shall be free from any leakage, permeation
and other abnormalities. The water hammer value shall be 1.47 Mpa or under. The faucet after it has
been operated 100000 times it shall be free from a seat- leakage and shall satisfy the reverse flow
preventing performance. The inside and outside surfaces of the faucet shall be smooth and be free
7.29.1 44 from blowholes, fissures, remarkable flows or injurious defects. The chromium plating on the faucet each 1172 2 2344
shall be of class 2 grade 1. The final coating should be done with chromium of minimum 0.1 micron.
The faucet shall be made leak proof and fixing in position with selected tape etc. , all complete
approved and accepted by the Engineer- in- charge. Round headed CP Conceal Bib Cock short body
(Essco/coaster/star/diamond/delux/deco /orbed/delin/triple/master/classic headed or similar head)
(PWD BW 26.29.1)
Supplying different inside dia best quality uPVC soil, waste and ventilation pipe having specific
gravity 1.35 - 1.45, wall thickness 2.5 mm - 3.0 mm, and other physical, chemical, themal, fire
resistivity properties etc. as per BSTI approved manufacturer standards or ASTM, BS/ISO/IS
7.43.1 45 standards fitting and fixing in position with sockets, bends, of uPVC Pipe with all accessories such as m 564 ০ 0
Round grating /domed roof grating bands, sockets etc. approved and accepted by the Engineer- in-
charge. 50 mm inside dia wall thickness 2.5 mm - 3.0 mm (PWD BW 26.43.1)
Supplying different inside dia best quality uPVC soil, waste and ventilation pipe having specific
gravity 1.35 - 1.45, wall thickness 2.5 mm - 3.0 mm, and other physical, chemical, themal, fire
resistivity properties etc. as per BSTI approved manufacturer standards or ASTM, BS/ISO/IS
7.43.2 46 standards fitting and fixing in position with sockets, bends, of uPVC Pipe with all accessories such as m 881 10 8810
Round grating /domed roof grating bands, sockets etc. approved and accepted by the Engineer- in-
charge. 100 mm inside dia wall thickness 3.4- 4.0 mm (PWD BW 26.43.2)
Supplying and fitting-fixing Chromium plated (CP) Shower head. all complete approved and accepted
7.38.1 47 by the Engineer- in- charge. each 1251 2 2502
Moving type 100 mm CP shower head (PWD BW 26.38.1)
Supplying, fitting and fixing of food graded plastic overhead water reservoir /tank including all
necessary fittings, hardware anchoring as shown in drwing and consumables etc. all complete
7.58.3 48 each 20955 1 20955
approved and accepted by the Engineer- in- charge.
2000 liter capacity (PWD BW 26.58.3)
Supplying, fitting and fixing of 5 mm thick unframed super quality double coated mirror with all
necessary fitting including making holes in walls and mending good the damages with cement
7.19.2 49 mortar (1:4) etc. all complete approved and accepted by the Engineer-in-charge. sqm 1724 1 1724
Belgium Mirror, 5 mm thickness (PWD BW 26.19.2)
Supplying, fitting and fixing of country made best quality towel rail/ring/shelf minimum 20 mm in dia
with C.P. holder including making holes in walls and mending good the damages with cement mortar
7.22.3 50 (1:4) etc. all complete approved and accepted by the Engineer- in- charge. each 1264 1 1264
600 mm long C.P. double towel rail (PWD BW 26.22.3)
Supplying, fitting and fixing of floor grating net in traps or in drains including making holes in
walls/floors and mending good the damages with cement mortar (1:4) etc. all complete approved
7.27.1 51 each 187 0 0
and accepted by the Engineer- in- charge. of following type
Approx. 50~75 mm dia stainless steel floor grating net (PWD BW 26.27.1)
Supplying, fitting and fixing of best quality pillar cock made from copper or copper alloy, chromium
plated materials. The faucet conforms BDS EN 200:2009. The faucet tap shall be free from any
leakage, permeation and other abnormalities. The water hammer value shall be 1.47 Mpa or under.
The faucet after it has been operated 100000 times it shall be free from a seat- leakage and shall
satisfy the reverse flow preventing performance. The inside and outside surfaces of the faucet shall
7.31.2 52 be smooth and be free from blowholes, fissures, remarkable flows or injurious defects. The each 1540 1 1540
chromium plating on the faucet shall be of class 2 grade 1. The final coating should be done with
chromium of minimum 0.1 micron. The faucet shall be made leak proof and fixing in position with
selected tape etc. all complete approved and accepted by the Engineer- in- charge.
CP Single lever pillar cock (PWD BW 26.31.2)
Supplying, fitting and fixing of best quality surface mounted or conceal stop cock/angle stop cock
(lever or round headed) with wall flange chromium plated. The faucet conforms BDS EN 200:2009.
The faucet tap shall be free from any leakage, permeation and other abnormalities. The water
hammer value shall be 1.47 Mpa or under. The faucet after it has been operated 100000 times it
shall be free from a seat- leakage and shall satisfy the reverse flow preventing performance. The
inside and outside surfaces of the faucet shall be smooth and be free from blowholes, fissures,
7.30.2 53 each 1202 0 0
remarkable flows or injurious defects. The chromium plating on the faucet shall be of class 2 grade
1. The final coating should be done with chromium of minimum 0.1 micron. The faucet shall be made
leak proof and fixing in position with selected tape etc. , all complete approved and accepted by the
Engineer- in- charge.
20 mm dia CP Concealed Stop Cock (PWD BW 26.30.2)
Supplying, fitting and fixing of best quality G.I. gate valve with sealant etc. complete approved and
7.52.2 54 accepted by the Engineer- in- charge. each 633 2 1266
20 mm brass gate valve (PWD BW 26.52.2)
Supplying, fitting and fixing of G.I. pipe with all special fittings, such as bends, elbows, sockets,
reducing sockets, Tee, unions, jam-nuts etc. including cutting trenches where necessary and fitting
the same with earth duly rammed and fixing in walls with holder bats and making hole in floors, walls
7.42.4 55 and consequent mending good the damages etc. all complete in all respects approved and accepted m 884 20 17680
by the Engineer- in- charge.
32 mm dia G.I. pipe with wall thickness 3.25 mm, outside diameter min 38.5 mm, weight 3.33 kg/m,
can withstand min 50 kg/cm2 hydraulic pressure. (PWD BW 26.42.4)
Item code Sl. No. Item Description Unit Rate Quantity Amount Remarks
Supplying, fitting and fixing of best quality G.I. gate valve with sealant etc. complete approved and
4.52.4 56 accepted by the Engineer- in- charge. each 1046 1 1046
32 mm brass gate valve (PWD BW 26.52.4)
Supplying, fitting and fixing of G.I. pipe with all special fittings, such as bends, elbows, sockets,
reducing sockets, Tee, unions, jam-nuts etc. including cutting trenches where necessary and fitting
the same with earth duly rammed and fixing in walls with holder bats and making hole in floors, walls
7.42.1 57 and consequent mending good the damages etc. all complete in all respects approved and accepted m 441 6 2646
by the Engineer- in- charge.
12.5 mm dia G.I. pipe with wall thickness 2.65 mm, outside diameter min 17.8 mm, weight 1.31
kg/m, can withstand min 50 kg/cm2 hydraulic pressure. (PWD BW 26.42.1)
Supplying, fitting and fixing of G.I. pipe with all special fittings, such as bends, elbows, sockets,
reducing sockets, Tee, unions, jam-nuts etc. including cutting trenches where necessary and fitting
the same with earth duly rammed and fixing in walls with holder bats and making hole in floors, walls
7.42.2 58 and consequent mending good the damages etc. all complete in all respects approved and accepted m 549 8 4392
by the Engineer- in- charge.
20 mm dia G.I. pipe with wall thickness 2.65 mm, outside diameter min 25.3 mm, weight 1.7 kg/m,
can withstand min 50 kg/cm2 hydraulic pressure. (PWD BW 26.42.2)
Connection to nearest WASA water supply pipe as per requirement and instruction of EIC.
59 LS 20000 20000
1
Sub Total = 90,130.00
Part-4: Cost of Electrical Works
SINCLE PHASE DISTRIBUTION BOARD (SPDB) Providing and fixing single phase distribution board
(SPDB) [concealed / surface having the following components and specifications: [Fig : 4.2]
1. Steel board: Approximate size: 20"x l5"x4" MS sheet : I8SWG with hinged type door and locking
arrangement duly painted with powder coating with epoxy polyester resin on all surfaces of board
(gray / off-white) etc. In front side there will be tempered thick fiber glass of minimum 8 mm
thickness with rubber gaskets to observe the inside arrangeme.
8.02.1* 60 each Set 12000 1 12000
2. Copper bar: Approximate size: l0"x l"x 3mm (2 nos) and 6"x 1" x 3mm, ( 1 no) mounted on
insulator at both ends. capacity: 60- 100A .
3. 1 No. DPMCB (main control) and following nos. SPMCB, DPMCB and SPMCB Manufactured /
Assembled and tested in accordance with relevant BDS IEC 60898-t:2016 and IEC / VDE / NEMA / BS
/ JIS standard. Minimum breaking capacity 6/10 KA with thermal over current and
instantaneous electromagnetic short circuit release.
4. Loop Cable [from phase.bar to SPMCB (circuit & power)] Size: lC- I x2.5 sq mm (BYM) with DPMCB
and SPMCB accepted /approved by the Engineer-incharge 6-way SPDB Incoming: lx40A DPMCB (6
KA)O utgoing: 6x5-l0A SPMCB (6 KA).
Cost Shall include the cost of connecting to the nearest sourse as per rule and instruction by te E-I-C.
CENTRIFUGAL PUMP MOTOR SET SINGLE STAGE ( SINGLE PHASE ) (For 1.000 11000.00
lower capacity/smaller household requirement) Providing of single stage 2800-2900 RPM monoblock
type Centrifugal water pump motor set (reservoir to overhead tank) manufactured according to
relevant BDS standard and ISO 9906:2012, GRADE 3B/ DIN/ NEMA/ IEC/ BS/ VDE/ JIS/CEI 2-3/ CSA/
GS/ SONCAP/ ROHS & ISO 9001 (Quality) ISO 14001 (Environment and Safety) standard of following
8.12.1.2* 65 capacity suitable for operation at single phase, 230 V ± 5 %, 50 Hz AC having insulation: B & Each Set 11000 1 11000
protection: IPX4 (minimum) & CE certified . Country of Manufacture: Bangladesh/ China/ Vietnam/
Malaysia as per sample accepted / approved by the Engineer-in-charge. Including cost of Connection
to
the MDB, Circuit breaker, Standard Swich etc. all complete in all respect as perinstruction of EI-C.
HP-1 Discharge (liter/min)- 10-100H ead (meter)- 35-16 Suction dia (mm)- 25 Delivery
dia (mm)- 25 [PWD