0% found this document useful (0 votes)
11 views

Pruebas Ber

This document contains the results of an SDH BERT test. The test showed no errors, alarms, or performance issues over the 8 hour test duration. Key network elements like the AU and TU passed all performance metrics. The received signal power was -14.2 dBm.

Uploaded by

edgar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
11 views

Pruebas Ber

This document contains the results of an SDH BERT test. The test showed no errors, alarms, or performance issues over the 8 hour test duration. Key network elements like the AU and TU passed all performance metrics. The received signal power was -14.2 dBm.

Uploaded by

edgar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

Exfo Inc.

Page 1 of 9

Job Information

Job ID tigo.pto.60
Circuit ID
Contractor Name
Customer Name adg
Operator Name
Comment

Report Header: Exfo Inc.


Report Title: IN14460312
Report Date: 08/11/2023 10:50:12

Test Application Type: SDH BERT

Test Setup

Signal Structure

P1 P1 SFP TX/RX <-> STM-1 <-> AU-4/TU-12 <-> Pattern Coupled

AU/TU
AU Number 0
TU Number 1, 1, 1

Test Configuration

Bit Error
Pass/Fail Verdict Disable
BER Threshold s
Service Disruption
Defect LOS
No Defect Time (ms) 300000
Pass/Fail Verdict Disable
SDT Threshold (ms)

Other
REI-L Computation Method

WOM_ALKAR_GTD_2023.11.08 08/11/2023 10:50:12


Exfo Inc. Page 2 of 9

Overwrite STS-1 Fixed Stuff Column


Synchronization Status Message (S1) Quality Unknown

Pattern
Pattern PRBS 2^15-1
Invert Non-Inverted
RX Live Disabled

Clock Sync
Clock Mode Internal

Traces/Labels
Generated Traces
RS (J0)
AU Path (J1)
TU Path (J2)
Generated Labels
AU Path (C2) TUG structure
TU Path (V5) Test signal, ITU-T O.181

Test Results

Start Time: 11/07 16:50:29


Duration: 01/01/1970 8:00:00
TestStatus: Completed
Pass/Fail Verdict: Disabled
Power Recovery: 0

BERT
Bit ErrorPass/Fail Verdict: Disabled
Seconds
Pattern Loss: 0

Seconds Count Rate


Bit Error: 0 0 0,00E00

Service Disruption

Service Disruption Monitoring Disabled

Frequency

WOM_ALKAR_GTD_2023.11.08 08/11/2023 10:50:12


Exfo Inc. Page 3 of 9

RX (MHz) 155,52
Offset (ppm) 3,5
Max (+) Offset (ppm) 3,6
Max (-) Offset (ppm) 0,0

Alarms
Interface

Seconds
LOS: 0
Frequency: 0
LOC: 0

RS/MS

Seconds
RS-LOF: 0
OOF: 0
MS-AIS: 0
MS-RDI: 0

AU

Seconds
AU-AIS: 0
AU-LOP: 0
H4-LOM: 0
HP-RDI: 0
HP-ERDI-CD: 0
HP-ERDI-PD: 0
HP-ERDI-SD: 0

TU

Seconds
TU-AIS: 0

WOM_ALKAR_GTD_2023.11.08 08/11/2023 10:50:12


Exfo Inc. Page 4 of 9

TU-LOP: 0
LP-RDI: 0
LP-ERDI-CD: 0
LP-ERDI-PD: 0
LP-ERDI-SD: 0
LP-RFI: 0

BERT

Seconds
Pattern Loss: 0

Errors
RS/MS

Seconds Count Rate


RS-FAS: 0 0 0,00E00
B1: 0 0 0,00E00
B2: 0 0 0,00E00
MS-REI: 0 0 0,00E00

AU

Seconds Count Rate


B3: 0 0 0,00E00
HP-REI: 0 0 0,00E00

WOM_ALKAR_GTD_2023.11.08 08/11/2023 10:50:12


Exfo Inc. Page 5 of 9

TU

Seconds Count Rate


BIP-2 0 0 0,00E00
LP-REI 0 0 0,00E00

BERT(1)

Seconds Count Rate


Bit Error: 0 0 0,00E00

Performance Monitoring
BERT
G.821 Near-End

EFS 43200

EC 0

ES 0

SES 0

UAS 0

ESR 0,00E00

SESR 0,00E00

DM 0

M.2100 OOSM Near-End

ES 0

SES 0

UAS 0

AU

WOM_ALKAR_GTD_2023.11.08 08/11/2023 10:50:12


Exfo Inc. Page 6 of 9

G.828 ISM Near-End Far-End

EFS 43200 43200

EB 0 0

ES 0 0

SES 0 0

BBE 0 0

UAS 0 0

ESR 0,00E00 0,00E00

SESR 0,00E00 0,00E00

BBER 0,00E00 0,00E00

SEP 0

SEPI 0,0

M.2101 ISM Near-End Far-End

ES 0 0

SES 0 0

BBE 0 0

UAS 0 0

MS
G.829 ISM Near-End Far-End

EFS 43200 43200

EB 0 0

ES 0 0

SES 0 0

BBE 0 0

UAS 0 0

ESR 0,00E00 0,00E00

SESR 0,00E00 0,00E00

BBER 0,00E00 0,00E00

WOM_ALKAR_GTD_2023.11.08 08/11/2023 10:50:12


Exfo Inc. Page 7 of 9

M.2101 ISM Near-End Far-End

ES 0 0

SES 0 0

BBE 0 0

UAS 0 0

RS
G.829 ISM Near-End Far-End

EFS 43200 --

EB 0 --

ES 0 --

SES 0 --

BBE 0 --

UAS 0 --

ESR 0,00E00 --

SESR 0,00E00 --

BBER 0,00E00 --

TU
G.828 ISM Near-End Far-End

EFS 43200 43200

EB 0 0

ES 0 0

SES 0 0

BBE 0 0

UAS 0 0

ESR 0,00E00 0,00E00

SESR 0,00E00 0,00E00

BBER 0,00E00 0,00E00

SEP 0

SEPI 0,0

WOM_ALKAR_GTD_2023.11.08 08/11/2023 10:50:12


Exfo Inc. Page 8 of 9

M.2101 ISM Near-End Far-End

ES 0 0

SES 0 0

BBE 0 0

UAS 0 0

Traces/Labels

Received Traces Received Traces

RS-TIM o--

HP-TIM o--

LP-TIM o--

Expected Traces E

RS-TIM RS-TIM

HP-TIM HP-TIM

LP-TIM L

Received Labels s

AU Path (C2) TUG structure


TU Path (V5) Test signal, ITU-T O.181
Expected Labels

HP-PLM/HP-UNEQ

LP-PLM/LP-UNEQ

Test Functions

Round Trip Delay

Successful --
Failed --

Delay (ms)
Last --
Minimum --
Maximum --
Average --

WOM_ALKAR_GTD_2023.11.08 08/11/2023 10:50:12


Exfo Inc. Page 9 of 9

Statistics
Statistics

Signal
Power: -14,2 dBm

System Information

Product Name: FTB-810-880 NetBlazer Series

Version: FTB-810-880 NetBlazer Series 1.1 SP6


Module Id: FTB-810

Software Product Version: 1.1.6.22

Hardware Assembly Revision: 66

Serial Number: 636725


Calibration Date: 13/08/2019 14:25:00

Logger

ID Time Event Duration Details


1 11/07 16:50:29 Test Started 2023/11/07
2 11/08 04:50:29 Test Stopped

WOM_ALKAR_GTD_2023.11.08 08/11/2023 10:50:12