AND UTM Table Top MCT
AND UTM Table Top MCT
Force Tester
MCTSeries
http://www.aandd.jp
Strength you can see!
Easy to operate with precision color touch panel.
General purpose MCT-1150 High performance MCT-2150
Load display resolution: 0.1N Load display resolution: 0.01N
No hassle start up
Compact Automatic calibration on start up means no
waiting around. (Load cell calibration unnecessary)
Space-saving design allows for table
top use〔250(W)×405(D)×711(H)mm〕. High precision load cell included
Simple
USB connection
・・・
・・・
・・・・・・・・
* PC sold separately
・・・
in 1mm/min increments.
・・・
Real-time graphing.
Calculate and display maximum value
・・・
and displacement.
・・・
panel to operate
・・・
・・・
・・・
1
Easy to operate touch panel
Limit settings
2
Supports various material tests * Not waterproof
Tensile strength test Food packaging puncture test Container seal peeling test
Pudding
Cup ramen
Medicine PTP packaging push force test Syringe resistant test Tablet strength test
3
Accessories
Optional jigs
❶ JM-JFM-500N Screw action jaws Maximum load 500N Price for one piece.
An upper and lower jaw are necessary for tensile strength tests.
(Not sold as a bottom/top pair) Face dimensions 19 (w) x 19 (h) mm, opening width 10 mm.
The face side is knurled.
JM-X001-500N Attachment set (Items with ★ included) Maximum load 500N Attachment set.
❺ JM-X003-500N ★ V groove indenter Maximum load 500N Tip V Groove angle 90°, diameter 10 mm, length 20 mm
❻ JM-X004-500N ★ Load sensitive plate Ø15mm Maximum load 500N Tip diameter 15 mm, height 16 mm
❼ JM-X005-500N ★ Cone indenter Maximum load 500N Tip cone 90°, diameter 10 mm, length 20 mm
Maximum load 500N Tip edge angle 60°, blade width 10 mm,
❽ JM-X006-500N ★ Cone indenter diameter 10 mm, length 20 mm
JM-X009-500N M6 Male screw adapter Maximum load 500N Used to fix M6 female screw jigs or attachments.
JM-X010 Lower adapter Maximum load 500N Used to shift the position of lower jigs.
JM-X011 MCT vice Maximum load 500N Open width max 30 mm.
JM-X012 MCT safety cover Safety cover for preventing scattering of materials. Made of acrylic.
JM-X013 MCT jaw stand for Tensilon jigs Maximum load 500N Jaw stand for use with Tensilon testing jigs. Fixed by pin.
JM-CL-100N-01 Puncture Test Jig replacement needles (10 piece set) Replacement for the above needle Diameter 1 mm, tip R 0.5mm.
Maximum load 50N Used for container lid seal peel strength measurement.
JM-PZ-50N Container seal peeling test jig Peels at approx. 45°.
❶ ❷ ❸ ❹ ❺ ❻
★ ★ ★
❼ ❽ ❾ 10 11 12 13
★ ★ ★
14 15 16 17 18 19
4
Specifications
Model MCT-1150 General purpose model MCT-2150 High performance model
Table / floor model Table model
Maximum capacity 500N
Crosshead stroke 400mm 370mm
Effective stroke * 1
315mm 285mm
Crosshead speed 10-300mm/min: Within 5% of the set value *2
Crosshead speed setting Digital setting: 1mm/min increments within the above range
Crosshead speed and load capacity Full speed range at maximum capacity
Crosshead return speed Three speed settings: 10, 100, 300mm/min
Load measurement accuracy 500N~50N : ±0.2% F.S
±0.2% F.S 50N~5N : Within 2% of indicator value
5N and lower : Within 0.1N
Load display resolution 0.1N 0.01N (0.1N will display for values over 100N)
Load calibration Auto-zero function (calibration unnecessary)
Displacement display 000.0mm (Min. 0.1mm) 00.00mm (Min 0.01mm : 0.1mm will display for values over 100mm)
Included software MCT-Logger MSAT-Lite
Safety mechanisms 1. Upper and lower displacement stroke limits
2. Overload limit (automatic shutdown when load cell passes 105% of rated capacity)
3. Emergency stop switch
2-M8 Depth 16
Test center
3-M6 Depth 16
83
104
60
60
63 73
711
136
A
Overhead view
B
104
(Base width)
B
Min 100, Max 500,
MCT-1150
123
Stroke 400mm