0% found this document useful (0 votes)
26 views3 pages

PERI Formwork Load Calculator Results

This document provides the results of a formwork load calculator based on guidelines for concrete formwork. It includes input values for the concrete type, slump, density, temperature, pouring height, and vibration depth. The results include the maximum possible lateral pressure of 48 kPa, a hydrostatic pressure head of 1.91 m, a minimum pouring time of 7 hours, and a maximum placement rate of 1 m/h. Notes indicate the equation used and a link is provided for the terms of use for the PERI applications.

Uploaded by

swertsimth
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
26 views3 pages

PERI Formwork Load Calculator Results

This document provides the results of a formwork load calculator based on guidelines for concrete formwork. It includes input values for the concrete type, slump, density, temperature, pouring height, and vibration depth. The results include the maximum possible lateral pressure of 48 kPa, a hydrostatic pressure head of 1.91 m, a minimum pouring time of 7 hours, and a maximum placement rate of 1 m/h. Notes indicate the equation used and a link is provided for the terms of use for the PERI applications.

Uploaded by

swertsimth
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Formwork Load Calculator | Results

based on ACI 347R-14

Boundary Conditions Legend


Shape of the cast section Wall / base Input value
Concrete Type (I) Output value
(mm) Concrete slump 160 mm

ρ (kg/m3) Density of concrete 2500 kg/m³

Fresh concrete
T (°C) temperature directly 20 °C
after concreting
h (m) Pouring height 7.00 m

Internal vibration depth ≤ 1.2 m Yes

Results
Characteristic value of the
CCP max
maximum possible lateral 48 kPa
(kPa)
pressure
hs (m) Hydrostatic pressure head 1.91 m

t (h) Minimum pouring time 7.0 h

R (m/h) Maximum rate of placement 1.00 m/h

Please pay attention:


 The illustrations and icons are understood to be system representations only. The additionally required
access and safety equipment for the use of this formwork system in accordance with the regulations are
to be taken from the corresponding assembly instructions.
The assembly instructions provide a basis for the project related risk assessment and the procedures for
the preparation and use of the formwork system by the company.
They do not replace however the latter.

 This application is based on the following document:


 ACI 347R-14: Guide to Formwork for Concrete.

Notes
Equation 4.2.2.1b(c) used for calculation (ACI 347R-14)

14.02.2024 | www.peri.com | © PERI SE Page 1 | 3


Formwork Load Calculator | Results
based on ACI 347R-14

Coefficient Concrete Type

CC = 1.0 (I) Concrete type I, II or III (no SCMs) without retarder

(II) Concrete type I, II or III (no SCMs) with retarder


CC = 1.2
(III) Cement blends containing less than 70% slag and less than 40% fly ash without retarder

(IV) Cement blends containing less than 70% slag and less than 40% fly ash with retarder
CC = 1.4 (V) Cement blends containing more than or equal to 70% slag or more than or equal to 40% fly
ash without retarder
(VI) Cement blends containing more or equal than 70% slag or more than or equal to 40% fly ash
CC = 1.5 with retarder
List of concrete types

14.02.2024 | www.peri.com | © PERI SE Page 2 | 3


Terms of Use
for PERI Applications

You can find the accepted Terms of Use for PERI Applications by clicking on the following link:

https://apps.peri.com/core/views/media/pdfs/en_tc.pdf

14.02.2024 | www.peri.com | © PERI SE Page 3 | 3

You might also like