What Is Cable Testing. How Is Cable Testing Done
What Is Cable Testing. How Is Cable Testing Done
com
Cabling is an expensive business and must be treated carefully. The expenditure of substitution
once the routes are all concealed is bigger. The fault is not always visible like crushing, bending or
kinking. Make sure that your cabling installer have made provision to protect installed cabling from
other worker’s actions. This is substantially less costly than changing cabling in the future. If cable
routes are guarded with no way of opening them between termination and installation, it is ideal to
terminate the cables for the time being, so they can be tested before the routes are protected.
Cable testing is made to drop down testing times. This is done to check the:
Cable conformity
Cabling quality
Cable functionality
We're offline
Leave a message
Privacy - Terms
https://carelabz.com/what-cable-testing-how-cable-testing-done/#:~:text=Check bolted electrical connections for,Torque Values for Electrical Connectio… 1/8
12/02/2024, 14:33 What is Cable Testing. How is Cable Testing Done | Carelabz.com
Many times, a fault in a cable can be seen well before it becomes an actual problem. A visual
inspection of all the cables in your facility is a great way to find trouble before it causes you a
downtime. We look for corrosion on the copper, cracks in the insulation, moisture on the cables and
many other indicators of damage to the cables.
Cable faults cost money and create disruption, so there is an enormous demand for cable test
techniques to ensure cables and joints are in good condition, and to allow cable faults to be located
rapidly.
Cable testing to both predict and then deal with faults is a vital concern for all those involved with
the distribution of electricity. A wide range of test techniques and test equipment are available to
allow this concern to be effectively addressed, but cable testing can, nevertheless, be a challenging
task.
For this reason, a resource that’s as important as the test equipment itself is access to expertise
that will help with selecting the best equipment for the job, and using it in such a way that it delivers
the best results
Given below are the tests and inspections that must be done before energizing low voltage cable
rated 600V or below.
Compare cable data with drawings and specifications. Pay attention to the number of sets, the
cable size, routing, and insulation ratings. Note these items on the test sheet.
Check uncovered parts of cable for material damage. Look at the condition of the cable jacket
and insulation of exposed sections. Verify that the connection points match what is shown on
the project single-line diagram.
Check bolted electrical connections for high resistance with the use of a calibrated torque-
wrench, low-resistance ohmmeter or thermographic survey.
When using a calibrated torque wrench, reference ANSI/NETA Table 100.12 US Standard
Fasteners, Bolt Torque Values for Electrical Connections.
The values of similar bolted connections must be compared and check which value shift by
more than fifty percent of the smallest value in the case where a low resistance ohmmeter is
utilized.
Look at the condition of the exposed cable jacket and insulation when performing a visual
inspection on low voltage wire and cable.
Inspect compression-applied connections by verifying that the connector is properly rated for the
installed cable size and has the proper indentations.
Perform an insulation-resistance test on each conductor with respect to ground and adjacent
conductors. Test period must be for 1 minute using a voltage according to manufacturer’s
published data.
If no literature from the manufacturer is available, apply 500 volts dc for 300-volt rated cable and
1000 volts dc for 600-volt rated cable. Insulation-resistance values must be according to the
We're offline
manufacturer’s published data. If no data from the manufacturerLeaveexists, the values should be no
a message
https://carelabz.com/what-cable-testing-how-cable-testing-done/#:~:text=Check bolted electrical connections for,Torque Values for Electrical Connectio… 2/8
12/02/2024, 14:33 What is Cable Testing. How is Cable Testing Done | Carelabz.com
less than 100 megohms. Perform continuity tests to ensure correct cable connection and
phasing.
Verify uniform resistance of parallel conductors using a low-resistance ohmmeter. Measure the
resistance of each cable individually and investigate deviations in resistance between parallel
conductors.
Given below are various kinds of tests that are conducted on cables:
Given below are the tests done while cable testing is done:
Continuity Test
The continuity test (also called low resistance measurement) is measuring the low resistance of
cables, from 1 mΩ to 250 Ω.
The continuity test can be made in 2 or 4 wires according to the resistance to be measured: 2
wires for resistances > 1 Ω, and 4 wires for resistances < 1 Ω.
The continuity test in 2 wires mode consists in injecting a programmable current and measuring
voltage and current at the terminals of the resistance to be tested. Ohm’s law will give the exact
value.
In four wires mode or Kelvin method continuity test divide the switching matrix into 2 internal
buses
directing the test current
conveying the voltage of the terminals of the element under measurement.
Even-addressed points are allocated to the SENSE of the measurement, odd points to injection of
the current. This layout is doable all the way through the switching matrix and can be joint with two
wire continuity tests.
To give you an example, the continuity test in 4 wires mode lets you carry out measurements on
wires of 50 cm length and 5/10 mm cross-section (between 7 and 13 mW) with good resolution.
Insulation Test:
The insulation test also known as high resistance test is always made DC. The insulation test is
combined with a short-circuit test and high voltage test in DC.
The insulation test combines several functions.
The insulation test can perform:
determining insulation resistances from fifty kilo ohm to two thousand mega ohm at high
voltage i.e. from 20V to 2000V.
measurement of dielectric strength and detection of short circuits.
The insulation test proceeds as follows:
We're offline
An initial test at low voltage (continuity measurement) to detect any short circuit (1). If a
Leave a message
short circuit is found, the insulation test stops (the message SHORT CIRCUIT appears in the
https://carelabz.com/what-cable-testing-how-cable-testing-done/#:~:text=Check bolted electrical connections for,Torque Values for Electrical Connectio… 4/8
12/02/2024, 14:33 What is Cable Testing. How is Cable Testing Done | Carelabz.com
error list).
If there is no short circuit, the high voltage is applied. During the programmable rise time (2),
if breakdown occurs, the voltage is displayed and the test stops (the breakdown voltage is
given in the error list).
If no breakdown occurs and if the voltage does not reach the required value (±10%), the
message U<Uprog appears in the error list.
Next, the voltage is applied for the duration of the programmed application time (3). If
breakdown occurs during this period, the moment when the fault appears is displayed in the
error list and the test stops.
Lastly, if all goes well, at the end of the application time (4), the insulation test is made, and
the insulation resistance measured. The tester will add a measurement time as a function of
the range requested. The measurement time varies from 20ms to 240ms according to range.
To end the sequence, the tester reduces the high voltage and then discharges the unit tested to
an earth resistance (total time 20ms).
This procedure is identical at the end of every measurement of insulation.
The dielectric strength test detects any sudden variation in the increase of the test current
outside the programmed limit.
The short circuit test or high voltage test can be programmed out of the test.
Phasing Test:
The correct phasing of all LV circuits shall be checked at all positions where the LV cables are
terminated into fuse bases and where any LV cable is run from point to point.
This test shall be performed with an instrument designed for the purpose. Mains frequency
voltage of 240 Volts is not acceptable for this test.
The neutral conductor shall be connected to the earth stake for this test.
In any overhead or underground network, the earth resistance at any point along the length of a
LV feeder is to have a maximum resistance of 10 ohms prior to connection to the existing
network.
In any overhead or underground network, the overall resistance to earth Shall be less than 1 ohm
prior to connection to the existing network.
The high voltage test (also called dielectric strength test or hipot test) can be made in AC or DC.
If the high voltage test is made in DC, it is then combined with insulation; if the high voltage test
is made in AC, it is then, this is then, more stressful for the sample and made according to the
sketch below. We're offline
Measurement of high voltage test under alternating current isLeave performed using an alternating
a message
voltage (50Hz) adjustable to an effective 50V to 1,500V. As is the case with direct current, the
https://carelabz.com/what-cable-testing-how-cable-testing-done/#:~:text=Check bolted electrical connections for,Torque Values for Electrical Connectio… 5/8
12/02/2024, 14:33 What is Cable Testing. How is Cable Testing Done | Carelabz.com
high voltage test detects any sudden rise of current up to a programmed threshold.
The short circuit test is maintained by default. The rise time is more than 500 ms and the
application time at least one period.
Warning: The high voltage test under alternating current is penalized by the capacitive value of
the tested equipment. It must be remembered that the generator power is limited to 5 mA.
Contact Us
LATEST UPDATES
We're offline
Leave a message
https://carelabz.com/what-cable-testing-how-cable-testing-done/#:~:text=Check bolted electrical connections for,Torque Values for Electrical Connectio… 6/8
12/02/2024, 14:33 What is Cable Testing. How is Cable Testing Done | Carelabz.com
Related Services
United Arab Emirates, Bahrain, Iraq, Jordan, Kuwait, Lebanon, Oman, Qatar, Saudi Arabia, Burundi, Comoros, Djibouti, Eritrea, Ethiopia, Kenya, Madagascar, Malawi,
Mauritius, Mayotte, Mozambique, Reunion, Rwanda, Seychelles, Somalia, Tanzania, Uganda, Zambia, Zimbabwe, Angola, Cameroon, Central African Republic, Chad,
Congo (Brazzaville), Congo, Democratic Republic of the Equatorial Guinea, Gabon, Sao Tome, Principe, Turkmenistan, Uzbekistan, Tajikistan, Kyrgyzstan, Afghanistan,
Algeria, Egypt, Turkey, Libya, Morocco, South Sudan, Sudan, Tunisia, Western Sahara, Botswana, Lesotho, Namibia, South Africa, Swaziland, Benin, Burkina Faso, Cape
Verde, Cote d'Ivoire (Ivory Coast), Gambia, Ghana, Guinea, Guinea-Bissau, Liberia, Mali, Mauritania, Niger, Nigeria, Saint Helena, Senegal, Sierra Leone, and Togo.
We're offline
Leave a message
https://carelabz.com/what-cable-testing-how-cable-testing-done/#:~:text=Check bolted electrical connections for,Torque Values for Electrical Connectio… 7/8
12/02/2024, 14:33 What is Cable Testing. How is Cable Testing Done | Carelabz.com
We're offline
Leave a message
https://carelabz.com/what-cable-testing-how-cable-testing-done/#:~:text=Check bolted electrical connections for,Torque Values for Electrical Connectio… 8/8