0% found this document useful (0 votes)
27 views2 pages

Compressor INSPECTION REPORT

This document is an inspection report for an AC single or three phase motor. It records the nameplate data, incoming inspection results noting any damaged or missing parts, electrical test results including insulation resistance, winding resistance, polarity and surge tests. It also details the no-load run test results including vibration readings and voltages/amps. The mechanical test section examines bearing type and condition. The report concludes with notes on any required electrical or mechanical work.

Uploaded by

shahnawaz.onyx
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
27 views2 pages

Compressor INSPECTION REPORT

This document is an inspection report for an AC single or three phase motor. It records the nameplate data, incoming inspection results noting any damaged or missing parts, electrical test results including insulation resistance, winding resistance, polarity and surge tests. It also details the no-load run test results including vibration readings and voltages/amps. The mechanical test section examines bearing type and condition. The report concludes with notes on any required electrical or mechanical work.

Uploaded by

shahnawaz.onyx
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

AC SINGLE/THREE PHASE MOTOR INSPECTION REPORT

JOB NO. RECEIVING NOTE# DATE:

CUSTOMER DETAILS TYPE OF MACHINE


COMPANY NAME  AC MOTOR  DC MOTOR  COMPRESSOR
CONTACT NAME  STATOR  ROTOR  COIL
MOB#  PUMP  FAN / IMPELLER  GENERATOR

NAMEPLATE DATA
MANUFACTURER TYPE/CATALOG NO MODEL/STYLE/SPEC SERIAL NUMBER

POWER RPM VOLTS AMPS DUTY HZ AMBIENT °C WEIGHT

INCOMING INSPECTION
ITEM OK D M ITEM OK D M
FRAME NAMEPLATE
DRIVE END SHIELD MALE ROTOR
NON-DRIVE END SHIELD FEMALE ROTOR
TERMINAL BOX SLIDER
TERMINAL BOX COVER OIL FILTER
LEADS OTHERS (SPECIFY)
BEARINGS OTHERS (SPECIFY)
EYE BOLTS OTHERS (SPECIFY)
LEGEND: OK - GOOD CONDITION; D - DAMAGED; M - MISSING (INDICATE QUANTITY IF MORE THAN ONE)

ELECTRICAL TEST
TYPE OF TEST STATOR WOUND ROTOR

INSULATION RESISTANCE MΩ at VDC MΩ at VDC

WINDING RESISTANCE Ω φ1-2 φ2-3 φ1-3 φ1-2 φ2-3 φ1-3

POLARITY TEST  OK  NOT OK  OK  NOT OK

SURGE TEST VAC  OK  NOT OK VAC  OK  NOT OK

NO-LOAD RUN TEST


APPLICABLE  YES  NO HORIZONTAL VERTICAL AXIAL BALANCE REQUIRED WINDING REQUIRED

DE YES NO STATOR  YES  NO


VIBRATION READINGS
NDE   ROTOR  YES  NO

VOLTS AMPS φ1 φ2 φ3 SHAFT END PLAY

ONYX EQUIPMENT MAINTENANCE EST


ALI BIN ABI TALIB ROAD, ALFAISALIYAH
RIYADH - 12882, KINGDOM OF SAUDI ARABIA
MOBILE: +966 501 524 528 | EMAIL: [email protected]
AC SINGLE/THREE PHASE MOTOR INSPECTION REPORT - CONT'D.
JOB NO.

MECHANICAL TEST
ITEM 1 2 3 4 5
BEARING TYPE
BEARING NUMBER
BRG JOURNAL DIAMETER
BRG HOUSING BORE DIA.
BRG CONDITION
OTHERS:

CAUSE OF FAILURE

WORK REQUIRED
ELECTRICAL MECHANICAL

--- NOTHING FOLLOWS ---

ONYX EQUIPMENT MAINTENANCE EST


ALI BIN ABI TALIB ROAD, ALFAISALIYAH
RIYADH - 12882, KINGDOM OF SAUDI ARABIA
MOBILE: +966 501 524 528 | EMAIL: [email protected]