This document is a curriculum for a 64-hour training module on installation and maintenance of telecommunication and data services cabling at the Level III installation qualification. The curriculum covers topics such as cabling requirements and safety procedures, installation and maintenance of cabling infrastructure, cable termination and testing, and completing documentation. It includes four units that cover cabling systems, installation techniques, termination methods, and work completion processes. The goal is to teach technicians how to properly install, terminate, test and document telecommunication and data cabling systems according to industry standards and regulations.

Uploaded by

kassa mamo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
382 views140 pages

Bei3 M3

This document is a curriculum for a 64-hour training module on installation and maintenance of telecommunication and data services cabling at the Level III installation qualification. The curriculum covers topics such as cabling requirements and safety procedures, installation and maintenance of cabling infrastructure, cable termination and testing, and completing documentation. It includes four units that cover cabling systems, installation techniques, termination methods, and work completion processes. The goal is to teach technicians how to properly install, terminate, test and document telecommunication and data cabling systems according to industry standards and regulations.

Uploaded by

kassa mamo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 140

BUILDING ELECTRICAL

INSTALLATION
LEVEL III
Based on October, 2023, Curriculum Version II,

Module Title: Installation and Maintenance For


Telecommunication and Data Services Cable
Code: EIS BEI3 M3 10 23

Nominal duration: 64 Hours

Prepared By: Ministry of Lobar and Skill


October, 2023
Addis Ababa, Ethiopian
Table of Contents
Content

s
Table of Contents.........................................................................................................................................i

Acknowledgement......................................................................................................................................iii

Acronyms....................................................................................................................................................iv

Introduction.................................................................................................................................................1

Unit one: telecommunication and data service cabling Requirement.........................................................2

1.1 OHS procedures and Requirement....................................................................................................3


1.2 Nature, location and scope of the work............................................................................................5
1.4 Installation of earthing conductors..................................................................................................21
1.5 The work coordination with others infrastructure..........................................................................27
1.6 Material, Tools, equipment and testing devices..............................................................................28
Self-Check -1..............................................................................................................................................41

Operation sheet 1......................................................................................................................................42

LAP Test 1..................................................................................................................................................42

Unit two: Installation and Maintenance of cabling....................................................................................43

2.1. Structural support and cable management for catenaries system.................................................44


2.2 Protective earthing of metal work...................................................................................................49
2.3 Cables and wires handling...............................................................................................................50
2.4 Cables for interference segregation................................................................................................51
2.5 Install Cables in accordance with telecommunication regulation....................................................52
2.6 Over-voltage protection to suppress voltage surges with standard devices....................................54
Self-Check -2..............................................................................................................................................57

Unit three: Termination and testing of cables and earth wires................................................................58

Page i of cxlii Ministry of Labor installation and maintenance for Version -I


and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
3.1 Cable sheath for correct termination length...................................................................................59
3.2 Terminating modules (cables pairs) with recommended color code...............................................60
3.3 Terminating conductors...................................................................................................................72
3.4 Earthing cable shield........................................................................................................................74
3.5 Test and clearly labels of cable pairs...............................................................................................77
3.6 Terminate TRC/CES/Earth wires with connectors............................................................................84
3.7 Test Reference Cord (TRC) / Communications Earth System (CES) /Earth wire continuity..............85
3.8 Testing TRC/CES /Earthling system................................................................................................86

3.9 Labeling of earthling system............................................................................................................90


3.10 Testing and confirming Compatibility of alterations with existing systems...................................99
3.11 Direction for non-routine events.................................................................................................101
3.12 Routine quality termination of cables and devices......................................................................102
Self-Check -3............................................................................................................................................103

Operation sheet 3....................................................................................................................................104

LAP Test 3................................................................................................................................................104

Unit four: Complete cabling work, records and reporting......................................................................105

4.1 OHS work completion risk control measures and procedures.......................................................106


4.2 Work site safety.............................................................................................................................115
4.3 Record sheets and plans of cable..................................................................................................116
4.4 Cable pair record books.................................................................................................................120
4.5. Documentation and report completion of installing work.......................................................120
Self-Check -4............................................................................................................................................124

References...............................................................................................................................................126

Page ii of cxlii Ministry of Labor installation and maintenance for Version -I


and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
Acknowledgement

Ministry of Labor and Skills wish to extend thanks and appreciation to the many
representatives of TVT instructors and respective industry experts who donated their time and
expertise to the development of this Teaching, Training and Learning Materials (TTLM).
.

Page iii of cxlii Ministry of Labor installation and maintenance for Version -I
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
Acronyms
OHS................................................................Occopational health and safety
DSL................................................................Digital subscriber line
VoIP...............................................................Voice over Internet protocol
CSP................................................................Carriage service provider
MDF ..............................................................main distributor frame
IPTV...............................................................Internet Protocol Television
TV ................................................................Television
ADSL.............................................................Automatic Data System Location
ONT...............................................................Optical Network Termination unit
PC ................................................................Personal computer
LAN...............................................................Local Area Network
RG ................................................................Radio Guide
RJ ................................................................Registered Jack
NTD............................................................... Network Termination Device
NBN...............................................................National Broadband Network
CES................................................................communication earthing system
CCP................................................................Costumer connection Premises
FTTP..............................................................Fiber to the premises

Page iv of cxlii Ministry of Labor installation and maintenance for Version -I


and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
Introduction to the Module
In building electrical installation filed; Telecommunication and data services cable unit of
competence helps the trainees to complete communication and data services requirements in
parallel with communication. This module covers the knowledge, skills and attitude required for
installation and maintenance of telecommunications cabling in buildings and premises. It
encompasses working safely and to Ethiopian telecommunications and Media Authority's ‘Open’
Cabling Provider Rule, installing multiple telephone line, multi-pair cables, backbone cabling,
terminating in socket outlets, termination modules and distributors, testing and compliance
checks and completing cabling documentation.
This module is designed to meet the industry requirement under the Building electrical installation
occupational standard, particularly for the unit of competency: installation and maintenance of
Telecommunication and data services cable.
Module units

 Telecommunication and data service cabling Requirement


 Installation and maintenance of cabling
 Termination and testing cables and earth wires
 Complete cabling work, records and reporting

Learning objectives of the Module


At the end of this session, the students will able to:

 explain telecommunication and data service cablingRequirement

 Install and maintain cabling

 Terminate and test cables and earth wires

 Complete cabling work, record and report

Module Learning Instructions:


1. Read the information written in each unit
2. Accomplish the Self-checks at the end of each unit

Page 1 of 142 Ministry of Labor installation and maintenance for Version -I


and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
3. Perform Operation Sheets which were provided at the end of units
4. Do the “LAP test” giver at the end of each unit and
5. Read the identified reference book for Examples and exercise

Page 2 of 142 Ministry of Labor installation and maintenance for Version -I


and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
UNIT ONE: Telecommunication and Data Service Cabling
Requirement
This learning unit is developed to provide the trainees the necessary information regarding the
following content coverage and topics:

 OHS procedures and Requirement


 Nature, location and scope of the work
 Cable routes plan based on building structure and regulations
 Installation of Earthing conductors
 The work coordination with others infrastructure.
 Tools, equipment and testing devices
This unit will also assist you to attain the learning outcomes stated in the cover page.
Specifically, upon completion of this learning guide, you will be able to:

 Follow OHS procedures and Requirement


 Determine Nature, location and scope of the work
 Apply Cable routes plan based on building structure and regulations
 Determine Installation of earthing conductors
 Explain the work coordination with others infrastructure.
 Obtain and check material, Tools, equipment and testing devices

1.1 OHS procedures and Requirement

1.1.1 OHS procedures for a given cabling work

Page 3 of 142 Ministry of Labor installation and maintenance for Version -I


and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
This information is intended to assist installer of telephone service to understand the telephone
wiring in residential and their home. This information, if used properly, can be helpful in fixing
or installing telephone wiring in residential or your home. Use of this OHS guide is at your own
risk. Improperly installed wiring could impair your phone service.
Although the voltage on active telephone wiring is typically very small, it can be hazardous to
some individuals and materials. In addition, telephone wiring can conduct dangerous electrical
shocks if it comes into contact with power wires. Caution should be used at all times. The Public
Service or your telephone service provider has no responsibility for any personal injury or
property damage which may result from your installation or attempted installation of inside
wiring. By proceeding with installation, you assume all risk of personal injury or property
damage, including but not limited to: loss of service, damage to property, or injury. If you do not
fully understand the concepts lay out in this OHS guide and are not completely comfortable
performing the work, do not attempt the installation or repair. Instead contact a professional such
as your telephone service provider.
1.1.2 Health and safety risks
Telephone installation work is generally safe provided you follow these guidelines:
 Do not work with outlets and wires that you are not sure are telephone facilities. If you
are unsure which facilities are or are not telephone facilities, you should consult with an
experienced professional.
 Do not connect household electrical power to telephone lines.
 Do not work on any telephone wires (or any wires) during a thunderstorm.
 Work with insulated tools.
 Touch only one wire at a time.

Note: When working with telephone wires and connections, there is always the possibility of an
electrical shock. It is generally recommended that premises wiring be disconnected
fromincoming telephone lines. Do this at the NID. You may also choose to lift the handset of one

Page 4 of 142 Ministry of Labor installation and maintenance for Version -I


and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
telephone connected to the line as a means of avoiding electrical power surges which occur when
your telephone rings
Compliance with Local Building and Safety Codes
When planning and installing your telephone wiring and outlets, you must observe and comply
with any applicable state and local codes. Before doing any significant wiring work, you may
want to consult with your municipal government to determine if permits are necessary for the
work you plan to do.Before starting any telephone installation work, familiarize yourself with the
products, procedures and safety precautions outlined in this brochure. Be sure to review the
safety precautions included with any equipment you have purchased as well. As you work on
your telephone wiring (or any wiring) the “safety first” should be your guide. The
telecommunications industry has become increasingly diverse with the types and number of
services that are available, as well as the types and number of service providers. This information
is intended to be a guide for the “typical” situation involving telephone wiring. However,
depending on the type of service you are using (i.e., cable modem, digital subscriber line (DSL)
or any high-speed internet service, VoIP etc…) you may need to refer to other materials.
This guide will be particularly helpful if you wish to change phones, add an extension, or install
your own wiring system using the safety outlined.
1.1.3 Remote power feeding and risk control measures
Registered cablers working with telephone lines carrying broadband services need to take
precautions to avoid electric shock. Carriage service provider (CSP) broadband equipment within
the customer’s premises requires increased voltage, which is called power feeding. The risk of
electric shock increases when working with these higher voltages. Network cables carrying
power feeding circuits may bypass the main distributor frame (MDF) to extend through to the
CSP’s equipment or they may be installed on the MDF. Usually the power feeding network cable
will be laid in areas accessed by cablers. With broadband services, carriers and CSP’s may install
terminal equipment that is remotely fed using a current limited circuit. This has an open circuit
voltage which is higher than normal telecommunications network voltage. Authorization from
the relevant carrier of CSP is required to work on these network cables and should exercise

Page 5 of 142 Ministry of Labor installation and maintenance for Version -I


and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
caution when working near any accessible termination.The increased voltage also has the
capacity to damage test equipment.

1.2 Nature, location and scope of the work

Telecommunications are the means of electronic transmission of information over distances. The
information may be in the form of voice telephone calls, data, text, images, or video. Today,
telecommunications are used to organize more or less remote computer systems into
telecommunications networks.

This is a broad term that includes a wide range of information-transmitting technologies and
communications infrastructures. Examples include wired phones, cell phones, microwave
communications, fiber optics, satellites, radio and television broadcasting, the internet and
telegraphs.
Data service cabling is the wiring that connects your devices to your network and the internet. It
is essential for any business or organization that relies on data to operate.
When cabling a building for data services, it is important to choose the right type of cable and to
install it properly. The most common type of cable used for data services is twisted pair cable.
Twisted pair cable comes in two categories: Cat5e and Cat6. Cat6 cable is the newer and faster
type of cable, and it is recommended for new installations.
When installing twisted pair cable, it is important to follow these guidelines:
 Use cable ties to secure the cable to walls and ceilings.
 Avoid running the cable near electrical wires or other sources of interference.
 Terminate the cable using RJ-45 connectors.
The following diagram shows an example of how to cable a building for data services using
switches, routers, and hubs:

Page 6 of 142 Ministry of Labor installation and maintenance for Version -I


and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
Figure 1.1 How to cable building for data services using switches, routers, and hubs:

There are two main types of data service cabling: copper and fiber optic

Figure 1. 1 Copper data cable

Page 7 of 142 Ministry of Labor installation and maintenance for Version -I


and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
Copper cabling is the most common type of data service cabling. It is relatively inexpensive and
easy to install. However, copper cabling has a limited bandwidth and can be susceptible to
interference.

Figure 1. 2 Fiber optic data cable


Fiber optic cabling is a newer type of data service cabling that offers much faster speeds and
bandwidth than copper cabling. However, fiber optic cabling is more expensive and difficult to
install.
The type of data service cabling that you need will depend on your specific needs and
requirements. If you need a high-speed and reliable network, then fiber optic cabling is the best
option. However, if you are on a budget or need to install the cabling yourself, then copper
cabling may be a better choice.
Here are some of the benefits of using data service cabling:
 Speed: Data service cabling can provide very fast speeds, especially when using fiber
optic cabling.
 Reliability: Data service cabling is very reliable and can provide a consistent connection
to your network and the internet.

 Scalability: Data service cabling is scalable to meet the needs of your growing business.

Page 8 of 142 Ministry of Labor installation and maintenance for Version -I


and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
 Security: Data service cabling can help to improve the security of your network by
making it more difficult for unauthorized users to access your data.

If you are considering using data service cabling, it is important to have a qualified professional
design and install the cabling system. This will ensure that the system is installed correctly and
that it meets your specific needs.
Here are some tips for choosing and installing data service cabling:
 Choose the right type of cabling for your needs. If you need a high-speed and reliable
network, then fiber optic cabling is the best option. However, if you are on a budget or
need to install the cabling yourself, then copper cabling may be a better choice.
 Have a qualified professional design and install the cabling system. This will ensure that
the system is installed correctly and that it meets your specific needs.
 Test the cabling system after it is installed to make sure that it is working properly.
 Label the cabling so that it is easy to identify and troubleshoot.
 Document the cabling system so that you can easily make changes or repairs in the
future.

Cabling System Documentation


The most often overlooked item during cable installation is the documentation of the new cabling
system. Cabling system documentation includes information about what components make up a
cabling system, how it is put together, and where to find individual cables.
This information is compiled in a set of documents that can be referred to by the network
administrator or cabling installer any time moves, adds, or changes need to be made to the
cabling system.
The most useful piece of cabling system documentation is the cabling map. Just as its name
implies, a cabling map indicates where every cable starts and ends. It also indicates
approximately where each cable runs. Additionally, a cabling map can indicate the location of
workstations, segments, hubs, routers, closets, and other cabling devices. To make an efficient
cabling map, you need to have specific numbers for all parts of your cabling system.

Page 9 of 142 Ministry of Labor installation and maintenance for Version -I


and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
For example, a single cable run from a cabling closet to wall plate should have the same number:
 on the patch panel port,
 patch cable,
 wall cable, and
 Wall plate.

This way, you can refer to a specific run of cable at any point in the system, and you can put
numbers on the cabling map to refer to each individual cable run.
Wire mapping is the most basic and obvious test for any twisted-pair cable installation. For
twisted-pair cables, you must test each cable run to make sure that the individual wires within the
cable are connected properly; you can select either the T568-A or T568-B pin out configurations
for a twisted-pair installation. Because all of the pairs are wired straight through and the
difference between the two configurations is minimal, there is no functional difference between
them. However, you should select one pin out and stick to it throughout your entire installation.
This way you can perform end-to-end tests as needed without being confused by mixed wire-pair
colors. A perfunctory wire-mapping test can be performed visually by simply checking the pin
outs at both ends of the cable. However, problems can occur that are not visible to the naked eye.
A proper wire-mapping tester can detect any of the following faults: Open pair occurs when one
or more of the conductors in the pair are not connected to a pin at one or the other end. In other
words, the electrical continuity of the conductor is interrupted. This can occur if the conductor
has been physically broken, or because of incomplete or improper punch down on the IDC
connector.
Shorted pair: A short occurs when the conductors of a wire pair are connected to each other at
any location in the cable.
Short between pairs: A short between pairs occurs when the conductors of two wires in different pairs
are connected at any location in the cable.
Reversed pair: A reversed pair (sometimes called a tip/ring reversal) occurs when the two wires in a
single pair are connected to the opposite pins of the pair at the other end of the cable.

Page 10 of 142 Ministry of Labor installation and maintenance for Version -I


and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
For example, if the W-BL/BL pair is connected on one end with W-BL on pin 5 and BL on pin 4 of the
connector, and at the other end of the cable, W-BL is connected to pin 4 and BL is punched down on pin
5, the W-BL/BL pair is reversed.
Crossed pairs Crossed (or transposed) pairs occur when both wires of one color pair are connected to the
pins of a different color pair at the opposite end.
Split pairs Split pairs occur when one conductor from at both ends of the run. Because this type of
faultessentially requires that the same mistake be made at both ends of the connection, accidental
occurrence of split pairs is relatively rare.

Figure 1. 3 Wire-mapping to show faults

Page 11 of 142 Ministry of Labor installation and maintenance for Version -I


and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
Wire-mapping faults are usually caused by improper installation practices, although some
problems like opens and shorts can result from faulty or damaged cable or connectors.
The process of testing a connection’s wire mapping is fairly straightforward and requires a
remote unit that you attach at one end of the connection and a main unit for the other end. Wire-
map testing is usually included in multifunction cable testers, wire-map testers that are far less
expensive.
The main unit simply transmits a signal over each wire and detects which pin at the remote unit
receives the signal. The problem of split pairs (two wires in different pairs transposed at both
ends of the connection) is the only one not immediately detectable using this method.
Because each pin is connected to the correct pin at the other end of the connection, the wire map
may appear to be correct and the connection may appear to function properly when it is first put
into service. However, the transposition causes two different signals to run over the wires in a
single twisted pair. This can result in an excess of near-end crosstalk that will cause the
performance of the cable to degrade at high data rates.
Although the occurrence of split pairs is relatively unlikely compared to the other possible wire-
mapping faults, the ability to detect split pairs is a feature that you may want to check for when
evaluating cable-testing products.
Wiring Elements of telecommunication consists of the elements that make up home wiring are:
 Telephone Cabling
 Data cable
 Free to air TV
 Pay TV
 IPTV (Internet Protocol Television)
 Distributed audio

Page 12 of 142 Ministry of Labor installation and maintenance for Version -I


and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
Telephone Cabling
The dial tone arrives at your home on two wires which are typically twisted together to form a
“twisted pair.” While twisted pairs can be bunched together to form large cables, by the time the
connection reaches your home, it has typically been reduced to an aerial drop wire (which
contain 1 to 6 pair), or a buried drop wire (which contain 1 to 6 pair). In order to tell the various
wires and pairs apart, there is an industry standard color coding system. Be aware, however,
depending on who installed the wire, there may be variances. However, if a professional installed
the wiring, they should have followed this color coding system. Your single-line phone system
will work properly when the wire color pattern is consistent with each wire secured to its proper
terminal on a jack or spliced to the same color (as in a junction block where a system branches).
In many of the new homes this is typically located near the electrical switch board but not
always. You need to identify where you want the phone system or handset physically connected.
Telephone wire normally used for inside installation contains four individually colored
conductors. The wire is solid copper in either 22 or 24 gauge. See Tables A and B for wire color
codes and spacing from other wire conductors.

Page 11 of 142 Ministry of Labor Installation and maintenance for Version -I

and Skills Telecommunication and data services cable October , 2023

Author/Copyright
Table 1. 1 wire connection and conduit chart

Data cable
Data wiring has two components, these are:
 Data service delivery
 Data network cable
The three most common ways data services are delivered to the home:
ADSL (Automatic Data System Location): ADSL services are typically delivered using the
telephone cabling. So wherever you have a telephone point you can install your ADSL modem.
When you have an ADSL modem you also need to install a filter at every location where you
have a phone plugged in. If you want to install the ADSL modem in a room where you don’t
have any phone point you will need to install a phone point by extending the phone cabling from
the nearest existing phone point.
Cable Modem:cable modems are typically installed in location where there is an existing Pay
TV service outlet. The installation requires the installation of a Pay TV outlet at which point you
connect the cable modem.
Fiberis the least common but it is growing in numbers. If the home has fiber to it, then the fiber
terminates on what is known as an Optical Network Termination unit (ONT) and it has a data
port on it. Cabling from the street to the point where the ONT is installed is fiber and is typically
installed by the service provider.

Page 12 of 142 Ministry of Labor Installation and maintenance for Version -I

and Skills Telecommunication and data services cable October , 2023

Author/Copyright
In all three cases the modem supplied or the ONT will have a data port which is an RJ45 socket
and this is the port that needs to be connected to the devices you need to connect to the internet.
This is the data network cabling or LAN cabling.
Data Cable (Network cabling)
To extend the data service from the data port on the ADSL modem, Cable Modem or ONT to
your networking devices (PC, printers, TV etc.) you need to install data cabling also referred to
as LAN (low area networking)) cabling. The cabling used for data networking is similar to the
phone cabling as it is twisted pair but of a much higher quality. The cable is known as Cat 5 or
Cat 6 where Cat stands for Category.
What you need to do is decide where networking devices are and install cabling from the
location where the data modem is located to where you have your PCs or TVs that need to
connect to the internet. The cabling must be installed as a start wired configuration that is the
cabling runs from the point next to the modem uninterrupted up to where you install the outlet
next to the device that needs to be connected to the internet. So unlike the phone wiring where
you could wire from one outlet to the next, here each outlet is wired individually back to the
location next to the modem. Therefore next to the modem you will have what is known as a
patch panel. Note, if all you need to plug into the modem is one computer then you can simply
buy an Ethernet cable of the desired length and connected to between the modem and the PC.
Free to air TV

Cabling for free to air TV requires the following:


 An antenna
 Coaxial cable
 TV outlets
There are a range of television antennas for a range of different locations, it is best to consult
with your local supplier as to which one is best in your situation. The antenna is typically
mounted external to the building most commonly on the roof.
From the antenna you need to run a coaxial cable from the antenna to the location where the television is
located. The two types of cable that may be used for coaxial cabling installations are
commonly referred to as “RG6”RG" Radio Guide (7 mm - 8 mm diameter) and “RG11” (10 mm
– 11 mm diameter). Like the “RJ” (Registered Jack) designations used for modular plugs and
Page 13 of 142 Ministry of Labor Installation and maintenance for Version -I

and Skills Telecommunication and data services cable October , 2023

Author/Copyright
sockets, the “RG” (Radio Guide) designations have no formal status and care needs to be
exercised when selecting cables purported to be “RG6” or “RG11”. (The use of RG11 coaxial
cable is not recommended in homes.)
Today the most common type of cable used for this purpose is RG-6 Tri-shield or quad-shield
cable. The cable is terminated on television outlets. The television outlets are typically an F
connector mounted on a face plate. In cases where you need multiple television outlets then you
run the cable from the antenna to an RF splitter. The RF splitter typically has one input for the
cable from the Antenna and two or more outlets depending on the splitter.
From the splitter you then run a coaxial cable to each outlet you are installing.
‘Additional notes’ On RF splitters, there are a few different types depending on the application.
They range from very basic splitters to active splitters when you install many TV outlets
throughout the home. While most TV outlets use the F connector the Television or digital set top
box usually come with a connector known as Belling Lee so the cable used to connect from the
TV outlet to the television will need to have an F connector in one end and a Belling Lee
connector at the other end.

TV outlets connected to an FTTP NTD or external TV antenna

Figure 1. 4 Two TV outlets connected to an FTTP NTD or external TV antenna

Page 14 of 142 Ministry of Labor Installation and maintenance for Version -I

and Skills Telecommunication and data services cable October , 2023

Author/Copyright
Figure 1. 5 Four TV outlets connected to an FTTP NTD or external TV antenna

Pay TV: The distribution of pay TV through the home uses the same type of cabling used for
Free to Air TV with some variations. The variations are:
 There is no antenna as there is either a satellite dish or a cable from the street.
 The cabling must be RG-6 quad shield
 You may be required to use the cable and cabling connectors approved by your pay TV
provider
 A Pay TV Set Top Box needs to be installed at each television where you want to have
access to Pay TV services.
In most cases the Pay TV Company will supply and install the satellite dish or cable from the
street and the cabling to the various locations where your televisions are. While you can pre-wire
for it if you do it must comply with the requirements detailed by the Pay TV Company you
choose. In many cases Pay TV services also require a telephone point so you can access movies
on demand, so if you have a Pay TV point you also need a phone plug.

IPTV: IP TV is television delivered to your home via the internet. So on any device you want to
watch IPTV on must be connected to the internet. To be connected to the internet it must be
connected to your data network.
Distributed Audio: Distributed audio refers to having the ability to have music throughout the
house where the music sources are all centralized. In every room and hallways you have a pair of
Page 15 of 142 Ministry of Labor Installation and maintenance for Version -I

and Skills Telecommunication and data services cable October , 2023

Author/Copyright
speakers and you can select to have all speakers play the same music throughout the house or
have different music in different location or zones as they are referred to. You can also remotely
control the music sources and volume throughout the house. There are a wide range of
distributed audio systems in the market and therefore the cabling you need depends on the
system you are installing. When wiring a distributed audio system the first step is choose your
equipment” and check what wiring is required by the equipment you have purchased.
In summary there are a few ways to wire up the system:
 Spear cabling is installed from the central equipment to the speaker location.
 Cat 5 or Cat 6 cable is installed from the Central equipment to the speaker location.
 Cat 5 or Cat 6 cable is installed to each room where you want the distributed audio and in
each room you have an amplifier and speaker.
1.3.1 Wire Routing Strategies
There are two standard routing strategies:
a. Continuous Loop: In this method a single wire runs from the demarcation point to a jack,
and then another wire runs to the next jack and so on, forming one continuous loop. But,
like Christmas tree lights, if the wire gets cut somewhere, all the jacks beyond the cut will
be disabled. This method may also make it more difficult to add a 2nd or 3rd line
somewhere in the house.

Figure 1. 6 Continuous Loop

Page 16 of 142 Ministry of Labor Installation and maintenance for Version -I

and Skills Telecommunication and data services cable October , 2023

Author/Copyright
b. Star Pattern or “Home Run:” As the name implies each jack is wired separately and
directly to a central point where they can be connected to the telecommunications
company’s wiring. This system may take more time and use more wire, but it more easily
accommodates future growth and trouble-shooting problems.

Figure 1. 7 Star Pattern or “Home Run”

You may find a combination of these strategies where there is a continuous loop on a floor of a
house, but each floor feeds independently to the demarcation point. In older condo and apartment
buildings you are likely to find a continuous loop, but newer buildings incorporate the “home
run” method.
1.3.2 Traditional cabling methods used for telephone and ADSL services
Traditionally, telephone and ADSL (Asymmetric Digital Subscriber Line)access points (outlets)
have been wired sequentially from an external connection point (e.g. a wall box), as shown in
Figure below. In some cases, a separate cable may be installed between an external Network
Termination Device (NTD) or a central ADSL splitter and an access point for connection of an
ADSL modem (also shown in Figure below).

Page 17 of 142 Ministry of Labor Installation and maintenance for Version -I

and Skills Telecommunication and data services cable October , 2023

Author/Copyright
Either telephone cable (two to three pairs) or data cable (four pairs) could be used with this
cabling method.
This type of cabling is often referred to as “legacy cabling” because it is a legacy from a bygone
era when telephones were the primary means of communicating with other persons outside the
home.
This method of cabling is unsuitable for new homes as it will not support modern
telecommunications services, especially data services supplied via the NBN.

Figure 1. 8 An example of conventional telephone/ADSL home cabling

1.3.3 Modern telecommunications services


NBN (National Broadband Network) services – require the installation of locally powered
electronic devices that are located inside the customer’s building, unit or apartment. With
modern telecommunications services, access points (outlets) should be cabled radially (“star
wired”) from an internal central connection point (CCP) located next to the powered electronic

Page 18 of 142 Ministry of Labor Installation and maintenance for Version -I

and Skills Telecommunication and data services cable October , 2023

Author/Copyright
devices, as shown in Figure below (some cabling providers may prefer to call the CCP a “cross-
connection point”).
Data cable (four pairs) rated at Category 5 or better must be used with this cabling method to
support both telephone and Ethernet (data) connections.
Note:Category 5 is the minimum required to support 100 Mbps Ethernet; however,
telecommunications recommends the installation of Category 6 cable as a minimum.

Figure 1. 9 Home cabling method for modern telecommunications services (e.g. NBN)

Page 19 of 142 Ministry of Labor Installation and maintenance for Version -I

and Skills Telecommunication and data services cable October , 2023

Author/Copyright
1.3.4 Telecommunications (telephone) network architecture

Figure 1. 10 Telecommunications (telephone) network architecture in building

Page 20 of 142 Ministry of Labor Installation and maintenance for Version -I

and Skills Telecommunication and data services cable October , 2023

Author/Copyright
Figure 1. 11 Typical in building copper twisted pair network architecture

1.3.5 Cabling system classes and component categories (AS/NZS 3080)


Page 21 of 142 Ministry of Labor Installation and maintenance for Version -I

and Skills Telecommunication and data services cable October , 2023

Author/Copyright
Table 1. 2 Cabling system classes and component categories

* UTP = Unscreened Twisted Pair,


STP = Screened Twisted Pair (see 4.14.4.4)
** While it could be assumed that Category 1 and Category 2 are the corresponding component
categories for
Class A and Class B cabling respectively, component categories were never assigned to Class A
and Class B.
Specifications for Classes A, B and C and Categories 3 and 4 have been removed from AS/NZS
3080.
*** Category 5e (“Category 5 enhanced”) was an interim specification issued to support Gigabit
Ethernet on aClass D cabling system using bidirectional transmission over four cable pairs.

1.4 Installation of earthing conductors

1.4.1 PCD (Premises Connection Device)


Where the outdoor PCD is an FTTP NTD or an ADSL NTD, an earthing conductor will be
required at the PCD location. In the case of an FTTP NTD, the earth is required for electrical
safety purposes whereas, for the ADSL NTD, the earth is for lightning surge suppression
purposes.

Page 22 of 142 Ministry of Labor Installation and maintenance for Version -I

and Skills Telecommunication and data services cable October , 2023

Author/Copyright
1.4.2. Coaxial cabling
Where a TV antenna distribution system is installed; the outer conductor of the coaxial cabling
may be earthed. Note: HFC coaxial cabling is separate, does not form part of the TV antenna
system and should not be earthed
1.4.3. Data cable screens
Current flow in a cable screen is a result of inductive and capacitive coupling between cable
cores and cable screens. Capacitive coupling is a source of screen and earth currents under no-
load conditions and load conditions. Inductive coupling is a major source of current under load
conditions.
Cable screens are used to control the electric field stress in the cable insulation, provide a
return path for cable neutral and fault current, and shield against electromagnetic radiation. If the
screen is earthed at both ends, it provides shielding for electromagnetic radiation.
If the cable screen is single point bonded, there is no electrical continuity, and mmf generates a
voltage. If the cable screen is bonded at both ends, the mmf will cause circulating current to flow
if there is electrical continuity. If screened data cables are installed, the cable screens should be
earthed at the CCP.
1.4.4. Metallic parts
Metallic parts such as cabling or equipment enclosures do not normally need to be earthed but
may be earthed for screening purposes or additional safety if required. In such cases, it is
important to avoid “fortuitous bonding” (accidental multiple ear thing) of components, which
may create “earth loop” currentsthat could cause noise in the cabling system. For example, if
cable screens and metallic parts need to be earthed, they should be earthed by a single connection
to a common point (such as a metallic enclosure that is earthed) and should not be earthed at any
other point.
1.4.5. Equi-potential bonding
In all cases where earthing is required, the earth should be derived from the electrical earthing
system. This is an important safety requirement to ensure that there is no earth differential at or
in the building.

Page 23 of 142 Ministry of Labor Installation and maintenance for Version -I

and Skills Telecommunication and data services cable October , 2023

Author/Copyright
Earthing should not be achieved by driving a separate earth electrode unless that electrode is also
bonded (connected) to the electrical earth electrode or is for the sole purpose of providing a
lightning protection earth for an external antenna.
Telecommunications earthing is obtained from the electrical earthing system by means of
“equipotential bonding”, i.e. by “bonding” (connecting) the two earthing systems together to
ensure that they are at “equal potential”. The equipotential bonding must be done at the electrical
switchboard either inside the switchboard itself by connection to the main earthing bar or main
ear thing conductor, or outside the switchboard by connection to the main ear thing conductor or
to the electrical earth electrode. The three allowable methods of equipotential bonding are
illustrated in Figure below.
It is important that there is a demarcation point between the electrical earthing system and the
telecommunications earthing system so that:
 the telecommunications earth can be isolated from the electrical earth at a single, readily
accessible point by either a telecommunications worker or an electrical worker; and
 Earthing of telecommunications equipment can be legally performed by a
telecommunications worker who is not also a licensed electrical worker.
This demarcation point will be either a Communications Earth Terminal (CET) located
outside the electrical switchboard or a distinct, removable connection device on the electrical
earth electrode.
Equipotential bonding methods

Figure 1. 12 Equipotential bonding to the earthing bar or terminal of the electrical switchboard
(method 1)
Page 24 of 142 Ministry of Labor Installation and maintenance for Version -I

and Skills Telecommunication and data services cable October , 2023

Author/Copyright
Figure 1. 13 Equipotential bonding to the main earthing conductor outside the electrical
switchboard (method 2)

Figure 1. 14 Equipotential bonding to the electrical earth electrode (method 3)

1.4.6. Earthing conductor size and colour

Page 25 of 142 Ministry of Labor Installation and maintenance for Version -I

and Skills Telecommunication and data services cable October , 2023

Author/Copyright
The equipotential bonding conductor must be at least 6 mm² in cross-sectional area (7/1.04 mm)
with green/yellow insulation. Any earthing conductor required for end-user lightning protection
purposes (such as to an ADSL NTD) must also be 6 mm² with green/yellow insulation. In all
other cases, a minimum 2.5 mm² (7/0.67 mm) green/yellow earthing conductor is required,
which must be cabled from the CET or other ear thing terminal. Earthing and bonding
conductors do not need to be installed in conduit within building cavities. The recommended ear
thing conductor arrangement for a generic cabling system is shown in Figure below.

Figure 1. 15Recommend earthing conductor cabling for generic home cabling

Notes:
1. Only a licensed electrical worker may access the internals of an electrical switchboard.
2. The equipotential bonding conductor between the ear thing bar or terminal of the
electrical switchboard and the CET must be at least 6 mm² (7/1.04 mm) copper conductor
with green/yellow insulation and labeled “Telecommunications Bonding Conductor” or
“Communications Bonding Conductor”
3. The CET should be located in the telecommunications compartment of the CUE, if
provided, in accordance with Figure above or, if a CUE is not provided, the CET should
be located immediately below the electrical switchboard.
4. The ear thing conductor between the CET and the PCD should be at least 6 mm² (7/1.04
mm) copper conductor with green/yellow insulation. There is no need to label this

Page 26 of 142 Ministry of Labor Installation and maintenance for Version -I

and Skills Telecommunication and data services cable October , 2023

Author/Copyright
conductor. The total length of bonding/ear thing conductor between the ear thing
bar/terminal in the electrical switchboard and the PCD should preferably be less than 1.5
m but, in any case, should not exceed a length of 10 m.
5. The earthing conductor between the CET and the ear thing terminal at the CCP must be
at least 2.5 mm² (7/0.67 mm) copper conductor with green/yellow insulation. There is no
need to label this conductor. The length of this conductor must not exceed 135 m to
ensure that it does not exceed the maximum specified CES resistance of 1 ohm.
6. For a home networking system, an earthing terminal should be provided at the CCP. All
telecommunications earthing connections (e.g. to cable screens) should be made at the
CCP.
1.5 The work coordination with others infrastructure.
1.5.1 Clearance from other services
a. At poles and in-span: The minimum separation distances required from low voltage (230 V
AC single-phase or 400 V AC three-phase) power mains, associated fittings and terminations on
poles or in-span are set out.
b. At the building: sufficient separation must be provided at the building between the lead-in
cable attachment point and any insulated low voltage power service lead such that 600 mm can
be maintained between the power cables and fittings and the body of a person working on the
lead-in cabling. This means that if the telecommunications worker cannot safely access the lead-
in cable or attachment on the side of the cable or attachment furthest from the power cables and
fittings, a separation of at least 1200 mm will be required between the power cables and fittings
and the lead-in cables and fittings at the building..
c. Use of telecommunication poles for power mains: While telecommunication will not use
any poles installed by the customer to support the LV power mains, telecommunication will
allow telecommunication -owned lead-in poles to be used to support the customer’s low voltage
(LV) power mains (i.e. 230 V AC single-phase or 400 V AC three-phase) under the following
conditions:
 Over any private land not traversable by road vehicles--------------------- 2.7 m
 Over any residential driveway --------------------------------------------------3.5 m
 Over any commercial/industrial driveway or private roadway ------------4.9 m

Page 27 of 142 Ministry of Labor Installation and maintenance for Version -I

and Skills Telecommunication and data services cable October , 2023

Author/Copyright
The power mains, associated fittings and terminations must be separated from the aerial
telecommunication cabling, associated fittings and terminations by the following minimum
distances:
 Insulated power mains -----------------------------------------At the pole 600 mm
------------------------------------- In span 600 mm
 Un insulated power mains -------------------------------------At the pole 1200 mm
---------------------------------In span 600 mm
 Light fitting, stay fitting or power conduit ------------------At the pole 50 mm

Clearance of aerial lines from the ground


The minimum ground clearances required for aerial lead-in cabling in residential areas are as follows (see
Figure below):

 Over any private land not traversable by road vehicles…….. ………………….2.7 m


 Over any residential driveway…………………………………………………..3.5 m
 Over any commercial/industrial driveway or private roadway ………………....4.9m.

Figure 1. 16Minimum ground clearances for residential aerial lead-in cabling

Page 28 of 142 Ministry of Labor Installation and maintenance for Version -I

and Skills Telecommunication and data services cable October , 2023

Author/Copyright
1.6 Material, Tools, equipment and testing devices
1.6.1 Materials

a. 4-pair Unscreened Twisted Pair (UTP) data cables

Page 29 of 142 Ministry of Labor Installation and maintenance for Version -I

and Skills Telecommunication and data services cable October , 2023

Author/Copyright
b. Coaxial cable elements

Figure 1. 17 Coaxial cable elements

Coaxial Cable Connectors


Coaxial connectors should be suitable for the type of cable used.
The standard connector for use with RG6 and RG11 cables used for generic cabling systems is
the F-type connector (“F-connector”). This connector has a threaded body (for the outer
conductor connection) and uses the center conductor of the coaxial cable as the center pin of the
male connector. The body of the female connector is threaded while the center pin connection
comprises a pair of “fingers” designed to clasp onto the center conductor of the cable terminated
in the male connector.
F-type coaxial connectors (F-connectors)

Figure 1. 18F-type coaxial connectors (F-connectors)

Splitters and diplexers

Page 32 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
Splitters are used to provide two or more access points (outlets) in the home. Cables to multiple
outlets cannot be simply connected together like telephone cables, as this will cause impedance
mismatches, signal reflections and excessive signal loss. Splitters provide a proper termination
for each cable maintain impedance balance and also provide some isolation (called “RF
isolation” or “mutual isolation”) between the outputs of the splitter to prevent mutual
interference between the output cables and the equipment connected to them.
Because splitters divide the signal, they incur signal loss between the input and each output leg.
For example, if the signal is split two ways, each output leg should get half the input signal level,
which equates to a 3 dB loss between the input and the output.

Typical RF splitters

Figure 1. 19Typical RF splitters

RF amplifiers for terrestrial free-to-air TV

Figure 1. 20Typical RF amplifiers for terrestrial free-to-air TV

A domestic “multiswitch” for distribution of satellite TV and other RF sources

Page 33 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
Figure 1. 21A domestic “multiswitch” for distribution of satellite TV and other RF sources

Figure 1. 22Coaxial wall plate

TV outlet (wall plate)


The wall plate containing the coaxial connector should be mounted at the same height as the
power outlets and TOs, which should not be less than 300 mm from the floor. Coaxial connectors
may be mounted on the same wall plate as data sockets but it is recommended that no more than
three coaxial connectors be fitted to any wall plate.
Adaptors
Various F-type adaptors are available for different applications. Examples are shown.

Page 34 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
Figure 1. 23Some F-type adaptors

Socket type
8-position 8-contact (8P8C) modular sockets (commonly called “RJ45”) should be used for all
voice/data TOs to ensure compatibility with consumer Ethernet equipment (other types of socket
are available but may not be compatible with RJ45 plugs). The TO sockets should be rated to
match or exceed the cable rating (e.g. if Category 6 cable is installed, the sockets should be rated
at Category 6 or Category 6A).
6-position (6P) modular sockets (commonly called “RJ11” and used for telephone equipment
connections) should not be used as these will negate the generic nature (flexibility) of the cabling
system.

Figure 1. 24typical modular sockets and a typical to with two colour-coded sockets

Page 35 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
Figure 1. 25 Socket Terminal unit

Figure 1. 26 testing and different data cable sockets

1.6.2 Typical cable Installation Tools

Figure 1. 27 kits of data cable tools

a. Cable Stripper

Page 36 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
Cable strippers themselves are inherently relatively safe due to their design. Only use them on
the materials they are intended to strip and they will last a long time.
Cable strippers designed for use on coax can be used on structured cables with care.
A coaxial cable stripper has two appropriately spaced cutting blades to prepare the cable for
termination in the connector. A coaxial cable stripper may have adjustable blades for use with
different types of cable. A stripper with incorrect blade settings can score the center conductor or
remove excess outer conductor and degrade cabling performance. A stripper with fixed blades
designed exclusively for use on the type of cable being installed is recommended.

Figure 1. 28A typical coaxial cable stripper

b. Wire-Map Tester

Page 37 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
Figure 1. 29 Wire-Map Tester
c. Pair Continuity tester

Figure 1. 30 Pair Continuity tester

d. Voltage Meter

There is a right way and a wrong way to determine if an electrical circuit has a live voltage
on it. Touching it is the wrong way. A simple voltage meter such as the one pictured in
Figure 6.18 is a much better solution, and it won’t put your health plan to work. Though not
absolutely necessary in the average data-cabling tool kit, a voltage meter is rather handy.

Page 38 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
Figure 1. 31 voltage meter

e. Punch Down Tool or Insertion Tool

A punch down tool, also called a punch down tool or a krone tool (named after the KRONE
LSA-PLUS connector), is a small hand tool used by telecommunication and network
technicians. It is used for inserting wire into insulation-displacement connectors on punch
down blocks, patch panels, keystone modules, and surface mount boxes (also known as
biscuit jacks)

Figure 1. 32 Punch down Tool or Insertion Tool

f. RF field strength meter

RF field strength meters are an essential tool to test signal strength (“RF power level”) and signal
quality at the RF source, wall plates and intermediate points where necessary. Different meters
are generally required to measure HFC (Cable internet/pay TV), TV antenna (and FTTP NTD)

Page 39 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
and satellite signals — although some meters are available that are capable of testing more than
one type of RF source.

Figure 1. 33 meter with a monochrome LCD display and meter with a miniature colourTVscreen

g. Cable cutter

Coaxial cable should be cut squarely prior to termination using a cutting tool that does not
appreciably distort the end of the cable so that it may be properly prepared using a cable stripper
designed for the purpose. Coaxial cable cutters have concave cutting jaws that tend to slice,
rather than crush, the cable.

Page 40 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
Figure 1. 34 cheaper cable cutter and cutter for use on copper-clad steel

h. Compression tool

Figure 1. 35A typical compression tool

Compression Tools are a type of utility software. Furthermore, these tools help us to compress
and decompress files. An important part of a computer is storage space, it is very important to
maintain this storage. Therefore, we use compression tools to compress big files and decrease
their size.

1.8.3 Testing devices

Page 41 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
Test equipment must be in correct operating order. To maintain insulation resistance insulation must
be clean and in very good condition. Ensure that any calibrated equipment is in current test date.

Figure 1. 36 testing device

Testing devicesis generally more fragile than ordinary hand tools and more care must be taken.
Always return it to its protective case, keep clean and dry and do not use cleaning chemicals as
this may damage the plastic and seals, use a clean dry cloth.
1.8.4 Tone Generators and Amplifier Probes
The Tone Generator applies a tone signal to a wire pair or single conductor. Amplifier Probe will
trace wires and cables allowing for pin-point identification in cable bundles, a cross connect or
remote end. Cable Tracing Kit is ideal for twisted pair, coax and de-energized AC wiring.

Figure 1. 37 Tone Generators and Amplifier Probes

Page 42 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
Self-Check -1
Directions: Answer all the questions listed below. Use the Answer sheet provided in the next
page:
Part I. Choose the best answer from the question below
1. Which of the following is the most useful piece of cabling system documentation?
A. cabling map B. cable connector C. wiring system D. all
2. Which of the following is the most common twisted-pair cable for LANs?

A. Fiber-optic cable C. Unshielded Twisted Pair Connector


B. Shielded Twisted-Pair cable D.Coaxial cable

3. Which of the following component is requires for free to air TV Cabling?


A. An antenna B. Coaxial cable C. TV outlets D. All

4. Wich of the following tools are used for cable installation ?


A. Cable striper C. cable map tester
B. Pair countinutiy tester D.all

Part II. Say true and false for the following question below
1. Straight through cables cables have identical ends and are used for connecting
computers through a hub/switch.
2. UTP is susceptible to crosstalk, radio and electrical frequency interference.
3. Signal cable is used in data transmission applications that demand superior signal
protection.
4. Crossover cables are used for connecting the same devices directly with each other.
5. UTP cable are used for data service and Telephone wiring.
PartIII. Answer the correct for the following question below

1. List at least two the types of F-type coaxial connectors (F-connectors).


2. List at least two Frequency Range (RF) splitters.
3. List at least 5 Typical cable Installation Tools.

Page 43 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
Operation sheet 1
Operation Title: Identifying RF splitters
Instruction: Using the types and application of splitters Identifying RF splittersUsed in
telecommunication and data service for TV coaxial cable installationinstructor
must check the installation before you applies power.
Purpose: When you have completed this Unit, the trainee should be able to identify the
equipment used in TV coaxial cable installation.
Required tools and equipment: unit one of this module, tools from workshops like screw
drivers, pliers, measuring instrument,
Precautions:
 Safe handling of hand tools, testing instruments and components
Procedures:
Step 1: Properly identify TV coaxial cable installation RF splitters
Step 2: Prepare electricalequipment for the given task
Quality criteria: Reading the circuit properly, safety procedures were followed & all hand tools
were cleaned.

LAP Test 1

Page 44 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
Name: __________________________ Date: ____________
Time started: ____________________ Time finished: _______________

Instruction I: Given necessary templates, tools and materials you are required to perform the following
tasks within 1hour.

Task 1: Identify RF splitters forTV coaxial cable installation properly

Unit two: Installation and Maintenance of cabling


This learning unit is developed to provide the trainees the necessary information regarding the

Page 45 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
following content coverage and topics:

 structural support and cable management for catenaries system

 Protective earthing of metal work

 Cables and wires handling

 Cables for interference segregation

 Cables in accordance with telecommunication regulation

 Over-voltage protection to suppress voltage surges with standard devices

This unit will also assist you to attain the learning outcomes stated in the cover page.
Specifically, upon completion of this learning guide, you will be able to:

 Check structural support and cable management for catenaries system

 Install Protective earthing of metal work

 Handling Cables/wires in accordance with manufacturer's specifications

 Allow sufficient cable ends to facilitate termination and tie Cable safely without
damage the sheath.

 Maintain Cables for safety and interference segregation

 Label Cables in accordance with telecommunication regulation

 Fitting Over-voltage protection to suppress voltage surges with standard devices

2.1. Structural support and cable management for catenaries system

Page 46 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
Structural support and cable management for catenary systems are two important considerations
for ensuring the safe and reliable operation of these systems.
Structural support
Catenary systems are typically supported by a series of structures, such as poles, towers, or
gantries. These structures must be strong enough to support the weight of the catenary wires and
any associated hardware, as well as any additional loads that may be applied, such as wind,
snow, or ice.
The structural support system must also be designed to allow for the thermal expansion and
contraction of the catenary wires. Catenary wires can expand and contract significantly due to
changes in temperature, so it is important to provide enough slack in the wires to accommodate
this movement.
Cable management
Catenary wires must be carefully managed to ensure that they are properly tensioned and
aligned. This is important for maintaining the electrical conductivity of the wires and preventing
them from contacting other objects.
Catenary wires are typically supported by a series of hangers, which are attached to the structural
support system. The hangers must be spaced at regular intervals and adjusted to ensure that the
wires have the correct tension.
The catenary wires must also be aligned to prevent them from arcing or contacting other objects.
This can be done by using insulators and spacers to keep the wires at a safe distance from each
other and from any other conductive objects.
Additional considerations
In addition to structural support and cable management, there are a few other considerations that
should be taken into account when designing and installing a catenary system. These include:
 Grounding: Catenary systems must be properly grounded to prevent the buildup of static
electricity and to protect workers and equipment from electrical shock.
 Lightning protection: Catenary systems must be protected from lightning strikes. This can be
done by using lightning rods and surge suppressors.

Page 47 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
 Maintenance: Catenary systems must be regularly inspected and maintained to ensure their safe
and reliable operation. This includes checking the condition of the structural support system, the
catenary wires, and the hangers.

2.1.1 Cable supports


a. Use of PVC trunking
The selection and use of PVC trunking shall comply with the following;
 All PVC trunking to be used shall be manufactured in accordance with BS 4678 where
applicable;
 All necessary trunking fittings, i.e. Tees, bends, end-caps shall be used. Such fittings shall
be of proprietary manufacture and installed to manufacturer’s instructions;
 In corridors where installed PVC trunking is visible, every effort shall be made to conceal
individual cable exit points by making such exit points through the rear of the trunking;
 Horizontal trunking runs in decorated areas shall be located at ceiling level where fixed
ceilings exist
 PVC trunking (including mini-trunking) shall be securely fixed with screws as per the
manufacturer’s instructions.
 The of use self-adhesive trunking is not recommended unless compelling reasons exist
 New PVC pathways shall not be more than 50% occupied at installation
 Newly installed PVC trunk should be selected to have 50% spare capacity after completion
of the works.
a. Use of Steel Conduit

While using steel conduits ensure that:


 All bends, tees, etc. shall be radius or gusset type suitable to allow the installation of the
cables without exceeding the cable bending radii.
 All lengths of Conduit shall be earth bonded to meet the 16th Edition IEE wiring
Regulations.
 New steel conduits are able to accommodate a 50% increase in occupancy at installation.
 Newly installed conduits should be selected to have 50% spare capacity after completion
of the works.

Page 48 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
b. Use of Steel Trunking
While using steel trunking it is important to ensure that:
 All trunking is free from sharp edges and projections likely to cause damage to the
cables contained.
 All bends, tees, etc. is of radius or gusset type suitable to allow the installation of
the cables without exceeding the cable bending radii.
 Fixings are spaced according to the manufacturer’s recommendations.
 All lengths of Steel trunking are earth bonded to meet the 16th Edition IEE
Regulations.
 New steel conduits should be able to accommodate a 50% increase in occupancy at
installation.
 Newly installed steel trunking shall be selected to have 50% spare capacity after
completion of the works.
c. Use of Cable Trays
In using cable trays the following should be considered:
A. All bends, tees, etc. shall be radius or gusset type suitable to allow the installation of
the cables without exceeding the cable bending radii.
B. Fixings shall be spaced according to the manufacturer’s recommendations.
C. All lengths of Cable Tray shall be earth bonded to meet the 16th Edition IEE
regulations.
D. New cable trays shall not be no more than 50% occupied at installation.
E. Cable trays shall be perforated galvanized mild steel sheet.
F. Minimum steel thickness for cable tray shall be:
 1.0mm for trays up to 150mm wide and
 1.2mm for trays up to 300mm wide
G. Trays shall have folded edges with minimum height of 20mm.
H. Electrical continuity shall be maintained along the full length of cable trays.
d. Use of Cable Basket

The following are considerations for using Cable baskets

Page 49 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
 All bends, tees, etc. shall be radius or gusset type suitable to allow the installation of the
cables without exceeding the cable bending radii.
 Fixings shall be spaced according to the manufacturer’s recommendations.
 All lengths of Cable Basket shall be earth bonded to meet the 16th Edition IEE
Regulations.
 New cable trays shall not be more than 50% occupied at installation.

2.1.2. Separation from electricity exclusive trench


Table2. 1 Separation from electricity exclusive trench

2.1.3 Correct locations of cables

Page 50 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
 Review any property documentation (e.g. building plans, electrical specifications, and
plumbing plan).

 Visually inspect the site noting the location of conduits, pipes or cables emerging from
the ground at buildings, sheds, swimming pools, fountains, electric barbecues, garden
lights, external power outlets, etc.

 Visually inspect the footway and verge for the location of any power, water, gas’
sanitation, storm water, drainage or telecommunications facilities (e.g. pedestals, pits,
poles, meters, kerb markers, drains, conduits/pipes, cables).

 Ascertain the likely path of underground services using the above indicators.

 Verify the location of services using a cable locator or similar equipment, if available
(note that existing services may not have been installed in a straight line).

 Verify the presence or absence of underground services at appropriate points along the
chosen trenching route by careful hand digging.

Where there is evidence of underground services along the chosen trench route but their
position cannot be verified with reasonable accuracy, look for a more suitable route or
excavate by careful hand digging where uncertainty exists. Apply the following precautions
when digging the trench:

 Allow for at least one 1 m separation from any suspected underground service.

 Except where otherwise required by this document, keep at least one 1 m away from
any pole (to avoid disturbance of the pole footings and to allow for future
replacement of the pole without disturbing the lead-in cabling that will be installed
in the trench).

 When hand digging, use non-conductive tools (e.g. with wooden handles) and wear
insulating (rubber) boots.

 Do not dig the trench any deeper than the recommended depth (see Table below)

Trench depth required telecommunication cable wiring:

Page 51 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
Table2. 2 Trench depth required telecommunication cable wiring

2.1.4 Securing catenaries supports to building structure


Catenary is wire or chain hung and supported at its end, such as wires used in decorative
lighting, electrical cable suspension, train lines and fiber optics.
Catenary: A cable carrying a uniform load along its length, such as its own weight, assumes the
shape of a centenary or a hyperbolic cosine curve. Under the influence of gravity, flexible
elements that are freely suspended in space develop this typical suspended form.
The centenary or messenger wire is hung at a specific tension between line structures, and a second wire
is held in tension by the messenger wire, attached to it at frequent intervals by clamps and connecting
wires known as droppers

Page 52 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
Figure 2. 1use of catenary wire supported to building structure

2.2 Protective earthing of metal work

In telecommunication systems with peripheral equipment powered directly from mains, the
system is earthed via all protective conductors (PE) and via the functional earth conductor (FE).
This arrangement fulfils the requirements against electrical shock.
1. Telecommunication room conductor (TRC) and Protective earthing (PE)
The TRC and the PE must be connected to the equipment on separate terminals, in
accordance with the individual TRC and PE requirements. The manufacturer will indicate
this in the installation manual.
2. TRC or PE Either a PE or a TRC must be connected to this equipment. However in some
uses of the type of equipment, a TRC must be used. (E.g. a CAE mounted behind another
CAE may need earth recall to access the first CAE.
Communication Earth System (CES)
Communication Earth System as defined in AS/CA S009:2013 may be used for any functional or
PE reference. Where either a TRC or a protective earth or both TRC and PE are specified, the
CES can be substituted for these requirements. If a TRC is specified and the CES in not suitable
(noisy, etc.) a TRC compliant to AS/CA S009:2013 will need to be installed.
Reinstalling Recovered CAE

Page 53 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
If a system is recovered from an installation, which originally required aTelecommunications
Service Earth (TSE) – then that system, when reinstalled must use the TRC in place of the TSE.
2.3 Cables and wires handling

General guidelines
While running or installing cables it is important that the following general guidelines are
adhered to;
 All UTP cables are to be run internally to the building and must not run between buildings;
 No UTP cable is to be run on the exterior of any building;
 No cabling is to be run in lift shafts or airflow areas;
 A comprehensive survey or an assessment of the cable routes shall be agreed upon prior to
installation of the cable;
 All vertical cables shall be secured to installed trays at intervals as recommended by the
cabling manufacturer;
 Care must be taken to avoid close proximity of cabling to water pipe work.
2.3.1. Walls and Floors
The following guidelines shall apply to cable runs made through walls and floors;
 Holes drilled through walls and floors for the routing of cables shall be suitably covered
to prevent damage to the installed cables. Where cables pass through floors, such
protection shall be extended to at least skirting height.
 Where cables, trunking, tray-work or conduit pass through floors or walls, suitable fire
sealing shall be provide

2.4 Cables for interference segregation

2.4.1 Precautions during Installation of Cables

a. Precautions shall be observed to eliminate cable stress caused by tension in


suspended cable runs and tightly strapped bundles.

b. Care shall be taken not to distort the twists by excessive pulling or bending of
cables.

Page 54 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
c. Cable bundles shall not rub on or be unduly compressed against or by any cable tray,
building or enclosure penetrations, equipment racking, or other cable support.
Similar forms of protection shall be provided where cables traverse sharp edges.

d. The weight of vertically installed cabling shall be adequately supported.

e. At minimum Cat 5E cables shall be securely fixed to cable trays using Velcro or
manufacturer recommended cable ties only.

f. Cables shall be neatly grouped together based on their destination and bound at
regular intervals.

g. Where cabling is run in cavity walls, surface mounted ducting and similar
enclosures, cables shall be installed in areas free from protrusion of screws and
similar fasteners

h. Care shall be taken to avoid tight twisting of the cable, tearing of the outer jacket,
cutting or wearing through due to abrasion of the cable.

i. When drawing cable through underground conduit, care must be taken to ensure that
the conduit is clear of water and other obstacles and appropriate action taken to
protect the cable from water and soil damage. Cable ends must be sealed
appropriately when being drawn though underground ducts.

2.4.2. Segregation
A. Care shall be taken to ensure UTP Cat 5E cables are not routed adjacent to other services
where electro-magnetic emissions may be generated. UTP Data cable must never be run
in the same containment as mains voltage cables or fire alarm circuits. Where data cables
are run in trunking containing mains cables and outlets the data cable must be segregated
in a separate part of the trunking.
B. Minimum segregation distances shall also comply with the standards laid down by the
cable manufacturer

Page 55 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
C. Cat 5 E (4 pair UTP) cables shall be kept in separate bundles from the multi-pair voice or
fiber cable.
2.5 Install Cables in accordance with telecommunication regulation

2.5.1 Installation Guidelines for Telecommunications Cable

1. The minimum horizontal cable bend radius, under no-load conditions, shall be four times
the diameter of the Category 6 cable. The minimum inside bend radius, under no load
conditions, for 4-pair UTP patch cable shall be .25 inches.

2. The maximum tensile loading shall not exceed 25 pounds on the Category 6 cable.

3. Cable ties shall not be installed as to place a strain or compression on the cable jacket.

4. Cables that serve several adjacent rooms shall be grouped together into bundles. A single
large cable bundle is preferable to several small bundles. It is preferred that the cables be
grouped in a way that reduces the quantity of bundles.

5. Cables in service areas such as attics, crawl spaces, mechanical chases, and above lay-in
ceilings shall be held in place with metal J-hooks or cable tray. The J-hooks shall keep
cables neatly bundled and shall be located so as to reduce interference with future
maintenance and construction projects. Cables shall be mounted at least 1' above drop tile
ceilings, shall never lie on the ceiling, and shall always be supported every 4 feet.

6. In areas where the installation of hooks is impossible, a discussion with an ITC


Communication Wiring representative should be initiated. The cables may be bundled
with plastic tie-wraps spaced no more than four feet apart, so long as the tie-wraps are
tight enough to neatly bundle the cables together, but loose enough to permit the pulling
of individual cables within the bundle.

7. Electrical or other tape, used for bundling cables during installation, shall be removed
once the cables are in place, to allow the slack in individual cables to be more easily
removed. Duct tape should not be used for this purpose.

Page 56 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
8. It is preferred that pull string be left in conduits, cable trays and cable hooks, after initial
cable installation, to allow for future cabling needs. Pull string shall be left in places that
will be difficult to access in the future.

9. Cables that are part of a bundle shall be of uniform length. Uniform cable length is
achieved by pulling on individual cables in a bundle after the bundle has been placed in
the hooks or raceway and before the cables are terminated.

10. Cable bundles shall hang with minimal tension between the hooks. Check cable bundles
to verify that individual cables do not have excessive tension, or are supporting the
weight of several other cables.

11. At vertical to horizontal transitions, cable bundles shall have a uniform loop containing
one to three feet of recoverable slack. Additional hooks may be required to support this
slack.

12. Long open vertical runs shall require intermediate support. These shall support the weight
of the cable between horizontal transitions. One foot of slack shall be left at each strain-
relief hook so as to insure proper loading of the hooks. Vertically mounted cable tray is
preferred for long vertical runs.

13. Four inches of service slack shall be left at each outlet box.

14. Twenty-four inches of recoverable slack in each cable shall be neatly bundled and
secured in the vertical wire management units located adjacent to the patch panel rack.

15. Slack or extra cable not mentioned in this section is unacceptable and shall be eliminated
prior to termination.

16. Patch cables will be neatly dressed in wire managers from the patch panel insert to
network switch and telephone patch panel. The upper one-half of a patch panel will have
patch cables go directly up to the horizontal wire manager, then right or left to the
vertical wire manager, then up or down to the network switch. The lower one-half of the
patch panel will have patch cables go directly down to the horizontal wire manager, then
right or left to the vertical wire manager, then up or down to the network switch

Page 57 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
2.5.2 Manufacturers Recommendations

A. All cabling shall be installed in full accordance with the manufacturer’s


recommendations and instructions. Cables shall be installed with due skill and
care so that:

1. Maximum permitted hauling tension is not exceeded

2. Minimum bending radius of the cable is not exceeded

3. Maximum permitted crush rating is not exceeded

B. Cable bundles shall not obstruct the installation and removal of equipment within
equipment enclosures.

C. Jumper wires on wiring frames shall follow clear paths to minimize jumper
lengths and avoid obstructing jumper fields.

D. Equipment and patch panels shall be laid out to minimize patch cord length. Patch
cords shall follow clear paths to avoid patch field obstruction.

2.6 Over-voltage protection to suppress voltage surges with standard devices

Power problems can be traced to various sources. The most dramatic ones are natural disasters as
they completely knock out the power supply by severing the utility lines. The less dramatic
sources include overburdened circuits, the introduction of unseen threats, such as surges,
brownouts, and line noise.
Therefore, every unprotected line that enters the equipment, whether it carries data or power,
represents a potential conduit for power problems.
Surges and spikes refer to the short-term voltage increases. They cause data corruption,
catastrophic equipment damage, and incremental damage that degrade the performance of the
equipment. Surges and spikes occur mostly due to lightning strikes, thunderstorms, ground
faults, and sudden power restoration after an outage.
Surge Protection

Page 58 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
Surge protectors trap the voltage that exceeds certain limits.When spikes occur for certain
duration of time, a trapping device known as a Metal Oxide Varistor (MOV) that is present in the
surge protector gets activated. Every surge protector has an MOV, which helps in diverting the
surge current.
The lifespan of an MOV shortens with use as more surge currents are diverted. They do not
display any indication of wear and tear, nor do they provide any forewarning of failure. So, when
they suddenly fail, their temperatures increase rapidly and cause fires.
Most surge protector’s function as a power strip even after their surge trap mechanism is
degraded by power spikes.
This can cause the following dangers:
 If another power surge occurs, it damages the equipment that is plugged into this surge
protector.
 If sufficient voltage passes through the surge protector during a second power spike, a
resistant short is formed that produces heat and can lead to fire.

Figure 2. 2Surge Protection on an ISDN Line Card Installed in a Cisco Chassis

Page 59 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
Self-Check -2
Directions: Answer all the questions listed below.
Part I. Choose the best answer from the question below.
1. Which of the following is used for cable supports?
A. PVC trunking B. Steel Conduit C. steel trunking D all

2. Which of the following documentation is reviewed for correct location of cable at


installation?

A. building plans B. electrical specifications C. plumbing plan D. all

3. _________are wire or chain hung and supported at its end, such as wires used in
decorative lighting, electrical cable suspension, train lines and fiber optics.
A. Wire mapping B. Catenaries C.Segregation D. cable support
4. _____________must never be run in the same containment as mains voltage cables or fire
alarm circuits.
A. UTP Data cable B. Telephone cable C. Coaxial cable d. all

Part ll. Say true and false for the following question below
1. New PVC pathways shall not be more than 50% occupied at installation.
2. All trunking is not free from sharp edges and projections likely to cause damage to the
cables contained.
3. New cable trays shall not be more than 50% occupied at installation.
4. No UTP cable is to be run on the exterior of any building.
5. The lifespan of an MOV shortens with use as more surge currents are diverted.

PartIII. Answer the correct for the following question below

1. List at least 3 methods of cable support.


2. List at least 3 considerations for using Cable baskets.

Page 60 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
Unit three: Termination and testing of cables and earth wires
This learning unit is developed to provide the trainees the necessary information regarding the
following content coverage and topics:

 Cable sheath for correct termination length


 Terminating modules (cables pairs) with recommended color code
 Terminating conductors
 Earthing cable shield
 test and clearly labels of cable pairs
 Terminate TRC/CES/Earth wires with connectors.
 TRC/CES /Earth wire continuity
 Testing TRC/CES /Earthling system
 Labeling of earthling system
 The Compatibility of alterations with existing systems
 direction for non-routine events
 Routine quality termination of cables and devices.
This unit will also assist you to attain the learning outcomes stated in the cover page.
Specifically, upon completion of this learning guide, you will be able to:

 remove Cable sheath for correct termination length


 Install Terminating modules (cables pairs) with recommended color code
 Terminating conductors
 Earthing cable shield
 Testing and clearly labeling of cable pairs
 Terminate TRC/CES/Earth wires with connectors.
 Maintain and observe TRC/CES /Earth wire continuity
 Testing TRC/CES /Earthing installation
 Labeling of earthing system
 Testing and confirming Compatibility of alterations with existing systems

Page 61 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
 Referring direction for non-routine events
 Checking and rectifying Routine quality termination of cables and devices.

3.1 Cable sheath for correct termination length


For Cat 5/5e/6/6A cable, the maximum amount of untwisted wire is specified as 0.5" (13
mm) but it's good practice to minimize the amount of untwist and the length of cable jacket
removed.
So, when wires are not tightly twisted, crosstalk happens. To prevent crosstalk, wire pairs in a
Cat5e cable should not be untwisted more than 0.5 inches and not more than 0.375 inches for
Cat6 cables.

Page 62 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
Figure 3. 1 Cable sheath for correct termination length UTP cable for installation

Coaxial cable is a type of transmission line, used to carry high-frequency electrical signals with
low losses. It is used in such applications as telephone trunk lines, broadband internet networking
cables, high-speed computer data busses, cable television signals, and connecting radio
transmitters and receivers to their antennas. It differs from other shielded cables because the
dimensions of the cable and connectors are controlled to give a precise, constant conductor
spacing, which is needed for it to function efficiently as a transmission line

Figure 3. 2 Cable sheath for correct termination length and connection for coaxial cable

Page 63 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
3.2 Terminating modules (cables pairs) with recommended color code

Terminating the cables involves installing some kind of connector on each end (either a
connector or a termination block) so that the cabling system can be accessed by the devices that
are going to use it. This is the part of cabling-system installation that requires the most
painstaking attention to detail, because the quality of the termination greatly affects the quality of
the signal being transmitted.
Though many termination methods are used, they can be classified one of two ways: connect or
patch-panel termination. There are many different types of patch panels, some for copper, some
for fiber. Coppercable patch panels for UTP all have a few similar characteristics, for the most
part.

3.2.1 Step-by-step: twisted-pair cable preparation and connector termination


The following steps will guide you through the preparation and termination process for UTP
cable. Following these guidelines will help give you the optimum performance from the twisted
pair cabling.
a. How to wire Ethernet Cables (data cables for socket outlet connection)

The following procedure elaborates the procedure at socket outletconnection.

Table 3. 1 procedure elaborates at socket outlet connection

Step 1: The tools you will need:


• Jacket stripper
•Punch-down tool (not shown)
• Wire cutters (not shown)

Page 64 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
Step 2: Insert cable into stripping
tool to the desired strip length.
Strip off only as much cable jacket
needed to properly terminate the
pairs (1 to 1½ inches should be
sufficient to terminate pairs).
Step 3: Holding the cable near the
tool, rotate the tool around the
cable several times.

Step 4: Slightly bend the outer


jacket and manually remove the
cut piece or slide the cut outer
jacket with the stripper.

Step 5: Bend each pair in one


direction to expose the rip cord,
binder or cross-web
filler on the cable.

Page 65 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
Step 6: Remove the rip cord,
binder or crossweb filler if they
are present on the cable, leaving
only the twisted pairs of wire. The
cross-web filler should be cut as
flush as possible to the jacket.

Step 7: Determine the wiring


scheme and properly align all four
cables accordingly on the jack.
Keep the cable jacket as close to
the connector as possible. Always
use connectors, wall plates and
patch panels that are compatible
(same rating or higher) with the
grade of the cable used.
Step 8: Preserve the wire pair
twists as close as possible to the
point of termination. When
connecting jacks and plugs, do not
untwist the cable more than 0.5
inches for Category 5e, 6 and 6A
cable.

Page 66 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
Step 9: Insert wires down into
IDC terminal slots to position
them before punching down.
Maintain the twist. To “future-
proof” an installation, terminate
all four pairs. The Picture above
shows an outlet being wired to the
T568B wiring scheme.
Step 10: When using a punch-
down tool, make sure the tool is
straight before punching down on
the connector. Make sure the cut-
side of the tool is facing outward.
Step 11: Inspect the connector to
verify that the wires are fully
engaged in the IDC terminals and
they are cut properly.

Step 12: Place a dust cover on the


jack for protection.

Step 13: This is how your


assembled jack should look.

Page 67 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
b. How to wire Ethernet Cables (data cables for Cross over connection)
The following procedure elaborates the Cross over connection procedure at RJ 45.
Things you'll need:

 RJ-45 Crimp Tool


 Cat-5e Cable
 RJ-45 Jacks

Table 3. 2 procedure elaborates the Cross over connection procedure at RJ 45.

Step 1.Prepare your workspace. Take the roll


of UTP cable and cut the cable to length
using the cutting blade on the crimp
tool.Splice the end by using the splicing
blades to expose the unshielded twisted pairs.

Step 2 Take each twisted pair and make four


wire strands, each going out from the center
of the wire.

Step 3 Now take the individual twisted wire


pairs and untwist them down to individual
wires in the following order: Striped Orange,
Orange, Striped Green, Blue, Striped Blue,
Green, Striped Brown, and Brow

Page 69 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
Step 4: grasp the wires with your thumb and
index finger of your non-dominant hand.
Take each wire and snug them securely side
by side

Step 5 Using the cutting blade of the crimp


tool, cut the ends off of the wires to make
each wire the same height

Step 6 once the first head is made, repeat


steps two through eight. When untwisting the
wires down to sing strands, use the following
order: Striped Orange, Orange, Striped
Green, Blue, Striped Blue, Green, Striped
Brown, and Brown.
Step 7.Insert the jack into the crimper and
press down tightly on the tool to seal the
wires in place.

Step 8: the finally climped cable ready for


use is shown below.

Page 70 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
Figure 3. 3 crossover cable color code for both end of cable

c. How to wire Ethernet Cables (data cables for straight through connection)
Instructions to prepare a straight through cable
Things you'll need:
 RJ-45 Crimp Tool
 Cat-5e Cable
 RJ-45 Jacks
Table 3. 3 procedure elaborates the straight through connection procedure at RJ 45.

Step 1Prepare your workspace. Take the roll of


UTP cable and cut the cable to length using the
cutting blade on the crimp tool.

Page 71 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
Step 2 Splice the end by using the splicing
blades to expose the unshielded twisted pairs.

Step 3 Take each twisted pair and make four


wire strands, each going out from the center of
the wire.

Step 4 Now take the individual twisted wire


pairs and untwist them down to individual
wires in the following order: Striped Orange,
Orange, Striped Green, Blue, Striped Blue,
Green, Striped Brown, and Brow

Step 5 Next, grasp the wires with your thumb


and index finger of your non-dominant hand.
Take each wire and snug them securely side by
side

Step 6 Using the cutting blade of the crimp


tool, cut the ends off of the wires to make each
wire the same height.

Page 72 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
Step 7 once the first head is made, repeat steps
two through eight. When untwisting the wires
down to sing strands, use the following order:
Striped Green, Green, Striped Orange, Blue,
Striped Blue, Orange, Striped Brown, and
Brown.

Step 8 still grasping the wires; insert the RJ-45


jack on the wires with the clip facing away
from you.

Step 9 Insert the jack into the crimper and


press down tightly on the tool to seal the wires
in place.

Step 10 Plug in the cable to test connectivity.

d. Terminating Category 5 or Category 6 cable on a socket

Page 73 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
Figure 3. 4 Terminating Category 5 or Category 6 cable on a socket

Figure 3. 5 Crimped Category 5 or Category 6 cable on a socket

3.2.2 Visual inspection to confirm termination color code


Cable colour and marking

Page 74 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
There are no mandatory requirements for cable sheath colours. However, cables with red sheath
should not be used, as red is normally associated with fire detection/alarm systems. Also, cables
with orange, white, pink or violet sheath should be avoided as they may be mistaken for power
cabling or cabling associated with power control (“home automation”).
It may be beneficial to the installer to use cables with different sheath colours (e.g. blue, grey,
yellow, green) to cable different sockets on the same TO. Alternatively, the cable sheaths may be
marked at each end with the TO socket colours, e.g. “Blue” and “White”, for the corresponding
socket colours, if different coloured sockets are to be used at each TO. In addition, mark the TO
cables at each end by room designation (e.g. “Kitchen”, “Family”, Bed 1”, etc.) or in numerical
sequence (i.e. “1”, “2”, “3”, and so on). The TO wall plates and the corresponding patch panel
sockets at the CCP should be coloured and designated in the same manner so that the end-user
will be able to readily identify them.

How to wire telephone cable (Telephone cable):


Step: 1. using a wire stripping tool remove about 4 inches of the outside plastic Sheath (usually
beige or grey) that bundles the wires together. Be careful not to nick insulation or cut the wires
beneath the sheath
Step: 2.using a wire stripping tool, remove about 1 inch of the plastic insulation fromeach of the
colored wires to expose the copper as shown here

Today, it is more common to see 4-twisted pair wiring like this:

Page 75 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
It is called “Cat 5” cable and is the national standard for all new telephone wiring projects.

Step:3. Fasten the jack casing securely to the wall or baseboard using the appropriate metal or
wood screws. Pull the wire through the opening in the jack casing and connect it as depicted here

Step 4.4-Pair Wire Connection: A 4-pair cable is wired to a standard jack as shown in the 3-pair
wire diagram above but also leaving the brown wires aside.
Step 5. Match each colored wire to the appropriate terminal on the jacks as shown inthe
diagrams. In the old standard color scheme the first pair has one greenwire ("tip") and one red
wire ("ring"). The second pair has one black wire("tip")and one yellow wire ("ring"). For a single

Page 76 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
phone line, only the green andred pair is normally used. The black and yellow pair is normally
spare and available to install a second phone line.

Step: 6. Ensure that no copper wire is touching any exposed metal inside the jack or electrical
box.

Step: 7. Ensure that all connections are secure.

Step: 8. Place the jack cover over the casing and either snap or screw it into place.

At the Demarcation Point:

Step :9. Strip the wire sheath and colored wires the same way you did for the jacks.

Step: 10. Connect the wires that come from each jack location to the entry wiring at the
demarcation point. Be sure to match the colors correctly
.How to wire coaxial Cables

Step-by-step: coaxial cable preparation and compression connector termination


The following steps will guide you through the preparation and termination process for coaxial
cable with compression connectors. Following these guidelines will help make sure that.you
receive the optimum performance from the coaxial cable.

Page 77 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
Table 3. 4 coaxial cable preparation and compression connector termination

Step 1: The tools you will need:


•Compression tool
•Cable stripper
•Compression connectors

Step 2: Adjust the blades of the stripper to


expose ¼ inch of the conductor and ¼ inch
of the insulation. Insert the coax cable into
the strip cartridge to the adjusted length.

Step 3: Holding the cable near the tool,


rotate the cutter around the cable (three to
five full turns) to score the jacket and cut
through the insulation. Be sure the braid is
cut (you can hear when the wires of the
braid have all been cut). Then flex the
jacket to separate and slide it off to expose
the center conductor.

Page 78 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
Step 4: Flare and bend back the remaining
outer braid onto the cable outer jacket.
Make sure to remove any stray or loose
braids. Stray or loose braids can cause
shorts if they touch the center conductor.
Verify that the center conductor and the
insulation are not nicked or scored.
(Note: When handling cables with multiple
braids, such as quad-shield, refer to the
manufacturer’s literature for proper braid
handling techniques.)
Step 5: Insert the sleeve ferrule and BNC
body onto the coaxial cable. Firmly push
the
cable as far as possible or until 1⁄8inch of
the center conductor is protruding from the
connector.
• Make sure the connector is fully seated
and the white dielectric Material is firmly
pushed against the inner stop of the
connector .You can see this by looking into
the open end of some connectors.

Page 79 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
Step 6: Insert the cable and connector into
the crimping device, making sure that it is
positioned firmly. Squeeze the crimp
handle tightly. Use a ratcheting tool that
does not release until the proper crimping
displacement has been applied for the
specific cabling and connector type. Once
the tool releases after the final “click,” the
crimp should be complete.
Step 7: Inspect the connection making sure
no braiding is exposed and that the
connector is firmly attached to the cable.

Page 80 of 142 Ministry of Labor installation and maintenance for Version -II
and Skills October , 2023
Telecommunication and data services cable
Author/Copyright
3.3 Terminating conductors

A wire termination is the work performed to the end of a wire that allows it to connect to a
device (connector, switch, terminal, etc.).

Wire Terminations – The Two Main Types

 Solder termination. Solder termination is when the open connector is melted and sealed to create
an extremely strong bond, thus forming a permanent connection.
 Crimp termination. A crimp termination is performed when the device requires a contact or
terminal. The wire insulation is stripped, and the contact or terminal is attached to the wire using
a crimp tool. The tool crimps the contact or terminal onto the wire conductor.
CCTV operates in a lower frequency range than CATV and requires different cable
constructions. Be sure that the cable used is chosen accordingly. The primary differences are
based on the frequency range differences as shown below
Table 3. 5 Types of Conductor

Table 3. 6 Shield Types conductor


CATV requires a foil shield to contain high-frequency noise in order to comply with FCC
regulations. CATV sometimes uses copper-covered steel. Because of this conductor type, care
should be given to not damage cutters when handling the steel in CATV coax.
3.4 Earthing cable shield

Earthing of Cable Shields and Drain Wires.

Cable shields are for signal protection from external influences. This is of a protectivenature not a
functional one associated with the operation of equipment. Hence shields and drain wires shall not
be connected to the TRC except where the TRC is equipotential bonded to the main earthing
bar,Conductor or electrode. The cable shield may be connected to any point on the CES.
Earthing Telecommunication Systems
Definition
The Communications Earth System (CES) is a dual-purpose telecommunications earthing
system used for both functional and protective purposes. Earthing conductors used for this
system have green/yellow insulation. The CES is available for any communications system that
requires and earth, fire, security, data, video or voice equipment/cabling etc. CES wires are
Green/Yellow earthingcolours. The Shield or drain wire of cables is connected to this earth and
the punch down module used for earthing is coloured green.
Figure 3. 6 punch down module

 Customer Network and Earthing Definitions ,Building Distributor (BD) or main


distribution frame (MDF) – a distributor in which the building backbone cables terminate
 Floor Distributor (FD) – the distributor used to connect between the horizontal cables and
other cabling subsystem or equipment. In most large buildings, large cables are run from
the BD to the FD where smaller cables then run out to other points
 Local Distributor (LD) is the distributor in which horizontal cables emanating from the
floor distributor may connect prior to connecting to telecommunications outlets. Small
cables may run from the LD to each individual phone outlet
 Customer Switching System (CSS) - A switching system in an installation that can switch
voice, digital data, images, video or any other information. One example is a PABX. The
figure below shows where these components fit into a distributed cabling system.

Figure 3. 7 Distributed cabling system component

The Telecommunications Reference Conductor (TRC) is a conductor used exclusively for


signaling and other functional telecommunications purposes. It is separate and distinct from the
protective earth and other building earth systems. It is not used for providing protection of
personnel. A TRC is an earthing system available for use where a functional earth is required by
customer equipment.
A TRC may be installed in new buildings when the telecommunications cabling is installed or in
an existing building if newly installed equipment requires a TRC to operate. If a TRC system is
installed, Technical Standard TS 009 (or its replacement) requires that it be connected to an earth
reference regardless of whether it is in use or not. Although the TRC system is connected to
earth, it is essential that you realise its true purpose. It is installed to make telecommunications
equipment function correctly. The TRC has no protective status what so ever.

Figure 3. 8 A TRC in new buildings when the telecommunications cabling is installed


Figure 3. 9 distance between electrical switchboard and telecommunication distributor when
earthing

The ‘designated distributor’ is a distributor, near the main or first electrical switchboard in the
building, designated by the cabling provider as the most appropriate distributor for distribution of
the TRC system. Where surge suppression devices are installed at the designated distributor, the
total earthing conductor length between the device and the main earthing bar in the electrical
switchboard should not exceed 10 m. A total earthing/bonding conductor length of 1.5 m or less
is preferred for more effective end-user protection and for protection of customer equipment
connected to the telecommunications line.
TFEE Definition A Telecommunications Functional Earth Electrode (TFEE) may be provided
for operational purposes or to limit the direct current flowing in the communications bonding
conductor.
3.5Test and clearly labels of cable pairs
Ensure that your inside wire is connected properly at the demarcation point. You can determine a
lot about the trouble by listening to sounds on your telephone line:
Static:Wires could be wet or pierced. Wires could be loose at a connecting point. Carefully
check all wires and connections.
Buzzing or Humming:A wire may have come into contact with metal, other than the connection
terminals. Is any exposed copper wire touching the box or other metal around the jack? Check
that colors have been matched correctly. Also, if you are using a cordless phone, you should try
plugging in a wired telephone to ensure that the problem is not with your equipment. Given the
nature of a cordless phone, it is possible that buzzing or humming is coming from the phone
itself and not your wiring.
Dead Air:Wires may be crossed. Is there a contact between any exposed copper from wires of
different colors (red crossed with green if 2-pair wire is being used; or blue crossed with white if
3-pair wire is being used)
Cross Talk:Be sure you are not using a cordless phone, since cross talk is likely from the
wireless nature of the phone. If you have multiple phone lines in the home or are in a multi-unit
dwelling, cross talk could be the result of damages or faulty wiring.
Check that all connections have been made properly.
 Are all the colored wires connected to the right terminals?
 Is the exposed copper wiring making a solid contact with the right terminals?
 Check the wire. Is it broken or split?
 Is it pierced by a staple, nail, screw or other object?

If it is, replace the entire section of wire from end to end.


Check that the pins or connecting terminals inside the jacks are not touching each other and that
a jack itself is not damaged.
How many phones do you have? It may be possible that your phones are drawing too much
energy and compromising the system as a whole. Unplug a few phones a see if the problems
persist.
Modem problems? If you are having problems connecting to the Internet, the problem may be
with the modem. Try disconnecting the computer and use a standard telephone and see if there
are problems on the line. If the line does not show a problem, the issue is likely with your
computer equipment. This is also trueif you are using a Digital Subscriber Line (DSL) (or other
high speed internet service) which may involve separate filters that could cause problems on the
line, even though the line is working properly.
3.5.1. Visual inspection to confirm termination colour code sequence for Data line
(Data cable)
You should ensure that the connection was done correctly by testing the cable with a cable tester.
Put the injector on one end of the cable and put the tester on the other end. Once you have the
tester hooked up, you can test the cable for continuity (no breaks in the conductors), near-end
crosstalk (NEXT), and Category rating (all quality-of-transmission issues). The specific
procedures for testing a cable vary depending on the cable tester. Usually you select the type of
cable you are testing, hook up the cable, and then press a button labeled something like Begin
Test. If the cable does not work or meet the testing requirements, reconnect the cable.
a. Locating Cable Faults
Time domain reflectometry has other applications in cable testing as well, such as the detection
and location of cable breaks, shorts, and terminators. The reflection of the test pulse back to the
transmitter is caused by a change in impedance on the cable. On a properly functioning cable,
the open circuit at the opposite end produces the only major change in impedance. But if an
open or short exists at some point midway in the cable run, it too will cause a reflection back to
the transmitter. The size of the pulse reflected back is in direct proportion to the magnitude of
the change in impedance, so a severe open or short will cause a larger reflection than a
relatively minor fault, such as a kink, a frayed cable, or a loose connection. If there is no
reflection at all, the cable has been terminated at the opposite end, which causes the pulse
signal to be nullified before it can reflect back.
Cable testers use TDR to locate breaks and faults in cable by distinguishing between these
various types of reflections. The problem may be caused by a cable that has been entirely
severed or by faulty or damaged wires inside the cable sheath. Sometimes you can’t tell that a
cable is faulty by examining it from the outside. This is why a test of each cable run during the
installation process is so important
b. Resistance measuring

The second method for determining the length of a cable is to measure its resistance using a
digital multimeter (DMM). All conductors have a resistance specification, expressed in ohms per
meter (or sometimes ohms per 100 meters or ohms per foot). If you know the resistance
specification for the conductor per unit of length, you can measure the cable’s resistance and
divide the result by the manufacturer’s specification to determine the cable’s length. In the same
way, if you already know the length of the cable from a TDR test, you can use the rating to
determine the cable’s total resistance.
Environmental factors can affect resistance as can the cable’s design and improper installation.
Resistance increases with temperature, so your length calculations will suffer accordingly if you
are measuring in a high- or low-temperature environment too far from the 20˚ C (68˚ F)
temperature the resistance specification is based on. The twist intervals of the pairs also will
influence your resistance measurement. Because the twists increase the actual length of the
conductors, the resistance reading will be higher and result in a longer-than-actual cable length.
And, if the conductor was stretched during installation, high resistance readings will result, again
producing longer-than-actual lengths for the cable.

Figure 3. 10 TDRs are also used to locate breaks and other faults in a cable
Tester OPEN Pulse Reflection

c. Performance Testing

The tests we’ve discussed so far all relate to physical properties of the cable and ascertain if the
cable has been terminated properly and is an acceptable length. They can be performed quickly
and with relatively unsophisticated and inexpensive test devices. They are the basic, minimum
levels of testing that should be performed to ensure your network will work.
But to properly characterize your cabling’s performance, a battery of transmission tests must be
administered; they determine the data-carrying capability of your cables and connectors.
The following characteristics were all defined in Chapter 1, so we won’t explain them further
here other than to note issues related to their testing.
All of the copper-cable tests discussed in the following sections, except for Propagation
Delay and Delay Skew, have formula-based performance requirements along a continuous
frequency spectrum. In the case of Category 5 and 5e, this range is 1MHz through 100MHz.
For Category 6, requirements at additional frequencies up to 250MHz are specified. If at any
point along the spectrum the cable exceeds the specification limits, the cable fails. This is called
sweep testing because the entire frequency range is being scanned.
Testing for transmission performance requires much more sophisticated equipment than
that used for wire mapping, opens, shorts, and crosses—equipment that can cost several
thousands of dollars per test set. However, the testing is essential for qualifying your cabling
installation to a particular level of performance, e.g., Category 5e. If you can’t afford such a
set, either contract with an installation-and-testing company that has one, or rent an appropriate
unit.
d. Impedance
As you learned earlier, variations in impedance cause signal reflections that a TDR uses to
measure the length of a cable. However, these signal reflections can be caused by different
factors, including variations in the cable manufacture, structural damage caused during
installation, or connectors that are a poor match for the cable. The statistic that measures the
uniformity of the cable’s impedance is called its structural return loss (SRL), which is measured
in decibels (dB), with higher values indicating a better cable. Even when the SRL of a particular
cable is acceptable, it is still possible for an installation of that cable to suffer from variations in
impedance that cause signal reflections. When you construct a network to conform to a particular
cabling specification, such as Category 5e UTP, to maintain a consistent level of impedance
throughout the entire length of the cable run you have to use connectors and other hardware that
have the same rating as the cable.
If, for example, during a twisted-pair installation, you fail to maintain the twist of the wire pairs
up to a point no more than 0.5 inches for Category 5 and 5e, and 0.375 inches for Category 6,
from each connection, you run the risk of varying the impedance to the point at which a
reflection occurs (as well as causing additional crosstalk). The cumulative amount of reflection
caused by variations in impedance on a cable run is called its return loss, which, like impedance,
is measured in ohms. If the return loss is too large, signal-transmission errors can occur at high
transmission speeds. The worst-pair performance is reported at the frequency where the result
came closest to the specified limits.
f. Attenuation
Attenuation is one of the most important specifications for high-speed networks; if it is too high,
the signals can degrade prematurely and data can be lost. This is especially true if your network
uses cable lengths that approach the maximum permitted by your networking protocol. Testing
the attenuation of a cable run requires a unit at both ends of the connection: one to transmit a
calibrated signal and another to receive the signal and calculate how much it has degraded during
the trip. Attenuation is measured in decibels (dB), and most good-quality cable testers include
the secondary module needed to perform the test. The worst-case result is reported.
g. Near-End Crosstalk (NEXT)
Along with attenuation, near-end crosstalk (NEXT) is one of the major impediments to
successfully installing and running a high-speed data network on twisted-pair cabling. Figure
below shows NEXT. Testing for NEXT is a relatively simple process with today’s sophisticated
test sets. After terminating the far end of the cable run to prevent any reflections from interfering
with the test, a signal is transmitted over one pair, and the magnitude of the crosstalk signal is
measured on the other pairs (in decibels). For a complete assessment, you must test each wire
pair against each of the three other pairs, for a total of six tests, and you must perform the six
tests from both ends of the cable. The worst-case combination is reported as the cable’s
performance result.

Figure 3. 11 Near-end crosstalk

.3.5.2 Cable-Testing Tools


The best method for addressing a faulty cable installation is to avoid the problems in the first
place by purchasing high-quality components and installing them carefully. But no matter how
careful you are, problems are bound to arise. This section covers the tools that you can use to test
cables both at the time of their installation and afterwards, when you’re troubleshooting cable
problems. Cable-testing tools can range from simple, inexpensive, mechanical devices to
elaborate electronic testers that automatically supply you with a litany of test results in an easyto-
read pass/fail format.
The following sections list the types of tools available for both copper and fiber-optic cable
testing. This is not to say that you need all of the tools listed here. In fact, in some of the
following sections, we attempt to steer you away from certain types of tools. In some cases, both
high-tech and low-tech devices are available that perform roughly the same function, and you
can choose which you prefer according to the requirements of your network, your operational
budget, or your temperament. Some of the tools are extremely complicated and require extensive
training to use effectively, where others are usable by anyone who can read. You should select
the types of tools you need based on the descriptions of cable tests given earlier in this chapter,
the test results required by the standards you’re using, and the capabilities of the workers—not to
mention the amount of money you want to spend.
a. Wire-Map Testers

Awire-map tester transmits signals through each wire in a copper twisted-pair cable to determine
if it is connected to the correct pin at each end. Wire mapping is the most basic test for twisted-
pair cables because the eight separate wire connections involved in each cable run are a common
source of installation errors.
Wire-map testers detect transposed wires, opens (broken or unconnected wires), and shorts
(wires or pins improperly connected to each other)—all problems that can render a cable run
inoperable.
Wire-map testing is nearly always included in multifunction cable testers, but in some cases
it may not be worth the expense to spend thousands of dollars on a comprehensive device
b. TDR length testing

A wire-map tester consists of a remote unit that you attach to the far end of a connection and
the battery-operated, handheld main unit that displays the results. Typically, the tester displays
various codes to describe the type of faults it finds. In some cases, you can purchase a tester
withmultiple remote units that are numbered, so that one person can test several connections
without constantly traveling back and forth from one end of the connections to the other to move
the remote unit.
WARNING The one wiring fault that is not detectable by a dedicated wire-map tester is a split
pair, because even though the pinouts are incorrect, the cable is still wired straight through. To
detect split pairs, you must use a device that tests the cable for the near-end crosstalk that split
pairs cause.
c. Continuity Testers

A continuity tester is an even simpler and less expensive device than a wire-map tester. It is
designed to check a copper-cable connection for basic installation problems, such as opens,
shorts, and crossed pairs. These devices usually cannot detect more complicated twisted-pair
wiring faults such as split pairs, but they are sufficient for basic cable testing, especially for
coaxial cables, which have only two conductors that are not easily confused by the installer.

Like a wire-map tester, a continuity tester consists of two separate units that you connect to each
end of the cable to be tested. In many cases, the two units can snap together for storage and easy
testing of patch cables.
d. Tone Generators

The simplest type of copper-cable tester is also a two-piece unit, a tone generator and probe,
also sometimes called a fox and hound wire tracer. With a standard jack, you connect to the cable
the unit that transmits a signal; or, with an alligator clip, you connect the unit to an individual
wire. The other unit is an inductive amplifier, which is a penlike probe that emits an audible tone
when touched to the other end of the conductor. This type of device is most often used to locate a
specific connection in a punch-down block. For example, some installers prefer to run all of the
cables for a network to the central punchdown block without labeling them. Then they use a tone
generator to identify which block is connected to which wall plate and label the punch-down
block accordingly.
3.6 Terminate TRC/CES/Earth wires with connectors.
Communications Earth System (CES) a system of ear thing using common elements to provide
for ear thing of electrical and communications equipment within premises. A CES may be used
for protective and functional ear thing for telecommunications purposes. Communications Earth
Terminal (CET) a terminal provided for the purpose of equipotential bonding of the CES or the
TRC(telecommunications referenceconductor) to the main ear thing bar, main ear thing
conductor or sub-main ear thing conductor of the electrical installation
The CET provides a demarcation between the electrical ear thing system and the
telecommunications ear thing system and was formerly known as a ‘bonding terminal’.
This conductor is generally supplied via the third pin of a power cord. However in some systems
this must be hard wired to the equipment by a licensed electrician. A hard wired PE connection is
specified in those instances where it is required.
Earthing Options
1. TRC and PE
The TRC and the PE must be connected to the equipment on separate terminals, in accordance
with the individual TRC and PE requirements listed above.
2. None. Neither a PE nor a TRC is required to be connected to this equipment.
3. TRC or PE Either a PE or a TRC must be connected to this equipment. However in some uses
of the type of equipment, a TRC must be used. (E.g. a CAE mounted behind another CAE may
need earth recall to access the first CAE. A TRC is required for this functional use).
3.7 Test Reference Cord (TRC) / Communications Earth System (CES) /Earth wire
continuity
Why use a TRC? If you are installing low loss connectors, those connectors may have a loss of ≤
0.15 dB. So testing it with a connector that has a loss greater than 0.15 dB will yield a
pessimistic result. More importantly, if your link is an engineered link operating to custom test
limits - you could be failing a perfectly good link. Another advantage is consistent and
predictable results - something installers often complain about when certifying a cabling system.
Pair Continuity Testers
Continuity testers can be used to check that pairs are not open circuit. They work on a similar
principle to an ohmmeter but usually use light emitting diode or audible tone indicators. Many
modern digital multimeters have built in continuity testers.
Other devices
There are several instruments that can be used to identify low resistance faults such as the Riser
Bond, PET or C2300.Multimeters Two main types of multimeters are in common use, analogue
or digital. Both types share many common features and are equally good for general purpose
testing. The digital multimeter is a battery operated instrument that uses a digital display. The
analogue type is a simpler in design and has an analogue meter display. All multimeters combine
the operations of voltmeters, ammeters and ohmmeters and usually offer the following:
 AC and DC voltage ranges from less than one to many hundreds of volts
 AC and DC current ranges from a few milliamps to several amps
 Resistance ranges from ohms to megohms
Inspection of Work
Inspection of work by a carrier the carriers are responsible for their networks. They also have the
right to inspect cabling work. They may inspect work to ensure it satisfies current AS/CA
technical standards in relation to network integrity, personal safety and proper network
functioning. If a carrier inspection reveals a threat to safety or integrity of their network then
they may disconnect or refuse to connect some or all services.
Maintenance of cabling advice It is the responsibility of the registered cabler to maintain all
necessary installation records. The registered cabler(maintenance licensed person) must maintain
these ‘cabling advices’ in a clear and legible fashion.

3.8 Testing TRC/CES /Earthling system

TRC/CES /Earthing installation is tested for continuity, insulation resistance and conductive
resistance as per relevant industry standards including AS/ACIF S009. Earthing system is
labeled in accordance with requirements.
What is TRC earthing?
Telecommunications Reference Conductor (TRC) A low noise earthing system providing a zero-
voltage reference point for telecommunications signaling and other functional purposes.

Continuity test

The earth continuity test is a designed to test the resistance of the protective earth of an appliance
and/or the supply lead. It is measured between any accessible earthed parts and the earth pin of
the plug. The test is based on the principles of Ohm's Law.
Insulation resistance test

Insulation resistance can be determined between live, neutral and earth connections with no loads
or appliances connected to any sockets or wiring. Any problems would be shown by a lower-
than-expected resistance being present between them. In domestic wiring anything above 2
megohms is acceptable.
Acabler can determine the approximate resistance of the CES by cable length. If the value is
close to the limit then a measurement will have to be taken which will account for any resistance
included at termination points.
Step 1 – Resistance measurement
(a) Select a pair (or extend one) to run from the:
(i) Protective earth bonding point (or CET if it is adjacent to the point of bonding) to,
(ii) The termination point of the CES at the CSS or LD To use in your measurements
(b) Connect each wire of the reference pair using an appropriate test lead, to the CES cable at the
CSS or LD after removing it from its termination point.
(c) Using a multimeter at the protective earth end, measure and record the loop resistance of the
reference pair. Record this value in the space below.
(i) R1 = _________Ω
(d) Now measure the resistance of each leg of the reference pair to the CES cable. Record this
value below
i) R2 = _________Ω R3 = _________Ω
(e) Before calculating the CES resistances removes all test conductors and reconnect the CES
cable to the earth terminal.
(f) Substitute your values of R1, R2 and R3 into the following formula to calculate the CES
resistance

You should remember that the resistance from the point of connection to the protective earth and
furthermost end of the CES cable should be no more than 1 ohm.
Terminate at CET’s Remove the insulation from the ends of all conductors and terminate them in
the CET’s. Be sure to consolidate all bared conductors by twisting or folding them in two. Make
sure both screws clamp on the conductor in the CET. Alternatively, if you are terminating using
cable lugs, use a sustainable crimp too to fit the lug to the TRC cable.
Joining to the sub main or Main earthing conductor To connect a bonding cable from a CET to
the sub main or main earthing conductor, use a line tap or an equivalent. Do not cut the earthing
conductor and be user to re-insulate the connection. Connecting to the Protective earth electrode
To connect a bonding conductor to an electrode, use an appropriate clamp and fit this below the
protective earth connection. Extend the CES to CSS To extend the CES to the CSS, run the
minimum sized CES cable to the earth terminal of the CSS (or a LD if a CSS is not available).
ACTIVITY – TESTING A CES Test the installation using Section 20 of AS/CA S009:2013 as a
guide. By using table 6 of AS/CA S009:2013 a cabler can determine the approximate resistance
of the CES by cable length. If the value is close to the limit then a measurement will have to be
taken which will account for any resistance included at termination points.
Testing A TRC Test your TRC installation using the testing procedure in AS/CA
S009:2013.
The cable tray should still be earthed to the protective earth from the previous CES activity.

1) Resistance Measurement

(a) Select a cable pair from the BD-FD riser to use in your measurements.
(b) Connect each wire of the reference pair to the TRC connection at the FD using an
appropriate test lead

(c) Disconnect the TRC riser from the earth bar at the BD
(d) Using a digital multimeter measure and record the loop resistance of the reference pair
from the

BD. Record this value in the space below.

(i) R1 = _________Ω
(e) Now at the BD measure the resistance of each leg of the reference pair to the TRC
cable. Record this value below.

(i) R2 = _________Ω R3 = _________Ω

(f) Before calculating the TRC reisitance remove all test short circuits and reconnect the
TRC to the BD earth bar

(g) Substitute your values of R1, R2 and R3 into the following formula to calculate the
TRC resistance

You should remember that the resistance from the BD link bar to the FD should be no more than
2 ohms. If it was required to test the resistance from the BD link bar to a LD the reference pair
would have to be extended to the LD and the testing process repeated. In this case 5 ohms is the
maximum permissible reading.
Accidental bonding
Once you have measured the resistance of the TRC and found it to be within the limits, it is
necessary to check for accidental equipment bonding.
(a) Remove the main TRC cable from the BD earth bar
(b) Make sure the BD earth bar is connected tot the protective earth at the CET
(c) Set the voltage on the insulation resistance tester to 500Vdc and connect the test leads tothe
TRC cable and the BD earth bar

(d)Measure the resistance and record the result below.

(e) Reconnect the main TRC cable to the BD earth bar the value you measure should be greater
than 1MΩ to comply with the standards.
3.9 Labeling of earthling system

With the increasing demand for computer network installations, telecommunications grounding
and bonding has become a growing opportunity for electrical contractors. Although similar
grounding principles apply, understanding the telecommunications terminology and special
considerations has been a challenge. As with traditional electrical grounding,
telecommunications networks and equipment should be grounded to the electrical service.
However, simply grounding to structural steel isn’t enough when tackling telecommunications
systems. The sensitivity of the electronic equipment requires that the telecommunications cabling
and power be effectively equalized to prevent loops or transients that can damage the equipment.
This means designing a complete grounding and bonding system that goes beyond the basic
"green-wire

3.9.1. Grounding
The NEC article 100 defines ground as:

“A conducting connection, whether intentional or unintentional, between electrical circuits or


equipment and the earth, or some conducting body that serves in place of the earth".”
Electrical systems and communication cabling systems that are required to be grounded must be
connected to the earth. The grounding mechanism must provide a reliable means to safely
conduct the voltages imposed by lightning, line surges, or unintentional contact with high
voltage lines or equipment to ground.

3.9.2. Bonding

The NEC article 100 and 250-70 defines bonding as:“The permanent joining of the metallic
conducting parts of equipment and conductor enclosures to assure and electrically conductive
path between them that will ensure electrical continuity and have sufficient capacity to safely
conduct any foreign current likely to be imposed to ground.”
Bonding is required because electrically conductive materials such as structural steel, metal cable
trays, and metallic supporting structures may become energized in the event of making contact
with: lightning, line surges, or unintentional contact with high voltage lines.

The practice of creating effective bonding is to create a reliable path for such fault currents to the
electrical system ground. Effective bonding practices help to equalize potential caused by either
lightning and electrical system faults that would otherwise damage equipment and harm
individuals. The NEC requires that metal raceways, cable trays, racks, enclosures, or metal cable
armoring must be effectively bonded to ensure the capacity to conduct any fault current to
ground.

The NEC Article 250-96 states: “Metal raceways, cable trays, cable armor, cable sheath,
enclosures, frames, fittings, and other metal noncurrent carrying parts that are able to serve as
grounding conductors, with or without the use of supplementary equipment grounding
conductors, shall be effectively bonded where necessary to ensure electrical continuity and the
capacity to conduct safely any fault currents likely to be imposed on them. Any nonconductive
paint, enamel, or similar coating shall be removed at threads, contact points, and contact surfaces
or be connected by means of fittings designed so as to make such removal unnecessary.”

3.9.3. Electrical exposure

Communication cables have exposure to electrical currents. The NEC Article 800-2 defines a
communication cable as “exposed” when

“The cable or circuit is in such a position that, in case of failure of supports or insulation, contact
with another cable or circuit may result.”
All communication cables are considered exposed to electrical current because of where these
cables are installed in a building or in a campus configuration. Communication cables are
installed in very close proximity to electrical conductors on walls and above ceilings.
The degree of expose is also determined by where the cable is installed. Exposure can be defined
in the following two areas:

 Outside building exposure

 Inside building exposure

a. outside Building Exposure

All copper communication cables, or any dielectric cables that have a conductive element, are
conductors of electrical energy. When these types of cables are run between buildings, they are
electrically exposed to lightning. These cables would carry a lightning strike along the cable and
into any cables that are connected to these cables.

b. Inside Building Exposure

Communication cables are exposed to electrical hazards inside a building. Copper


communication cables are installed in the same vicinity as electrical power conductors. These is
the possibility of accidental contact with power conductors, which would cause power fault
induction.

3.9.4. Telecommunications grounding and bonding standard

The ANSI/EIA/TIA-607 standard is the commercial building grounding and bonding


requirements for telecommunications. The primary objective of this standard is to provide
guidance around the issue of bonding and grounding as it relates to building telecommunications
infrastructure.

The ANSI/EIA/TIA-607 standard defines telecommunications grounding and bonding system


and the interconnections to the building electrical grounding system. The recommendations made
in this standard do not supersede the bonding and grounding requirements of national and local
electrical code.

Key Terms:
Bonding means permanent joining of metallic parts for the purpose of forming an electrically
conductive path to ensure electrical continuity and capacity to safely conduct any current likely
to be imposed.
Bonding conductor for telecommunications is a conductor used to interconnect the
telecommunications bonding infrastructure to the service equipment (power) ground of the
building.
Effectively grounded refers to an intentional connection to earth through a ground connection of
sufficiently low impedance. It must have sufficient current-carrying capacity to be able to
prevent the buildup of voltages that could potentially result in unnecessary hazard to connected
equipment or persons.
Ground is an intentional or accidental conducting connection between an electrical circuit or
equipment and earth or conducting body serving in place of earth.
Ground electrode conductor is a conductor used to connect the grounding electrode to:

 The equipment grounding conductor

 The grounded conductor of the circuit at the service equipment

 The source of a separate system.

3.9.5.Telecommunication grounding system components

The telecommunications grounding and bonding system starts with a physical connection to the
building grounding electrode system and extends to every telecommunications room (TR) in the
building (see the following figure).
Figure 3. 12 The telecommunications grounding and bonding system

In general, a telecommunications grounding system defined by the ANSI/TIA/TIA-607 standards


contains the following components:

 Telecom bonding conductor

 Telecom main grounding busbar (TMGB)

 Telecom bonding backbone (TBB)

 Telecom grounding busbar (TGB)

 Telecom bonding backbone interconnecting bonding conductor (TBBIBC)

The system begins at the electrical service entrance, travels to the TMGB and continues through
to each TGB located in individual telecommunications closets on each floor of the building
structure, finally looping back around to the original TMGB.

3.9.6. Telecom Entrance Facility (TEF)

The telecommunications entrance facility (TEF) includes the entrance point at the
telecommunications service and also the space where the inter- and intra-building backbone
facilities join. Telecommunication-related antenna entrances and electronic equipment may be
located in the TEF.

a. Telecom Bonding Conductor

Figure 3. 13 Telecom Bonding Conductor

The ANSI/EIA/TIA-607 standard requires that all communications bonding conductors be listed
for the intended purpose and approved by a nationally recognized testing laboratory such as UL
or ETL.Bonding conductors must always be insulated wires. The standard also requires that
bonding conductors be made of copper metal. Other metal types are not supported for use aa
bonding conductor by the ANSI/EIA/TIA-607 standard. In addition, the minimum size of all
bonding conductors must be at least a #6 AWG wire.

The ANSI/EIA-TIA-607 standard prohibits placing bonding conductors in a metallic conduit


made of iron. This standard requires that if the bonding conductor must be placed in an iron
conduit longer than 1m (3 ft.) in length, then bonding conductor must be bonded at each end of
the conduit. The wires used for bonding the bonding conductor must be at least a #6 AWG wire.

b. Telecom Main Grounding Busbar (TMGB)


Figure 3. 14 Telecom Main Grounding Busbar (TMGB)

The TMGB is the dedicated extension of the building grounding electrode system for the
telecommunications infrastructure. Because it is the central attachment point for TBBs and
equipment, the TMGB should provide easy access for telecommunications personnel.

The TMGB is predrilled copper bus bar with standard NEMA bolt-hole sizing and spacing for
the particular lug connection that will be used. It should be large enough to satisfy today’s
applications and accommodate future growth. A minimum of 6-mm thickness and 100-mm width
is required. Many varieties of ground bars are available, and some come as a kit and can be
customized to meet the specific requirements of the application. Pre-weldedCadweld pigtails are
available in a variety of conductor sizes and lengths, insulated or bare, ready to be attached to the
building ground.

For reduced resistance, electro tin plating is preferred. However, if not plated, the mating
surfaces must be completely cleaned. Where telecommunications panelboards are located with
the TMGB, they must have the alternating current equipment ground bus (or a metallic
enclosure) bonded to the TMGB/TGB. All appropriate clearances should be maintained while
locating TMGBs as close as possible to the panel boards.

Connections to the TMGB or lugs should be exothermic welds. Exothermic welds provide a
connection that helps ensure the long-term integrity of the grounding system.

c. Telecom bonding backbone (TBB)

Figure 3. 15 Telecom bonding backbone (TBB)

The TBB is a conductor that connects all TGBs with the TMGB. It reduces or equalizes potential
differences between the telecommunications systems to which it is bonded. The TBB should not
be the only conductor that provides a ground fault current return path.

Starting at the TMGB, the TBB loops throughout the building via telecommunications backbone
pathways. It connects TGBs in every telecommunications closet and equipment room within the
building. Multiple TBBs may be necessary, depending on the size of the structure and the
number of TGBs in the building. Water pipes or metallic cable shield should not be used as
telecommunications bonding backbone. Each TBB should be an insulated copper conductor, a
minimum of No. 6 AWG and possibly as large as 750 kc mil often used by telephone and
communications companies. In a multi-story building where more than one TBB is used, the
TBBs must be bonded together with a TBB interconnection bonding conductor (TBBIBC)
located on the top floor and at least every third floor.

d. Telecom Grounding Busbar (TGB)


Figure 3. 16 Telecom Grounding Busbar (TGB)

A TGB is a predrilled copper bus bar with standard NEMA bolt hole sizing and centrally
connected systems and equipment served by a telecommunications closet. It should be at least 6-
mm thick by 50-mm wide. Just like the TMGB, the TGB should be electrotin-plated or cleaned
prior to connecting the conductors to the bus bar. The bonding conductor between the TBB and
the TGB should be continuous and run in the most direct path possible.

Often, the TGB is installed to the side of the panel board. When the building’s structural steel is
effectively grounded, each TGB should be bonded to the steel within the same room with a No. 6
AWG conductor. Always use the shortest distance possible in the grounding system.

e. Telecom Bonding Backbone Interconnecting Bonding Conductor (TBBIBC)

The ANSI/EIA/TIA-607 standard requires that when two or more TBBs are installed vertically
in the intrabuilding backbone pathway, the TBBs must be bonded together. The
telecommunications bonding backbone interconnecting bonding conductor (TBBIBC) is the
component used for this function (see the figure above).The ANSI/EIA/TIA-607 standard
requires that the TBBIBC be installed at the top floor and a minimum of every third floor. The
minimum size of the TBBIBC must be no smaller than the TBB conductor size.

The TBBIBC would also be used to bond two or more TGBs installed in the same TR together.
The TBBIBC is also used to bond the TGBs installed in different TRs that reside on the same
floor of the building. This connection would follow the same requirements as bonding multiple
TBBs at the top floor and a minimum of every third floor.
3.10 Testing and confirming Compatibility of alterations with existing systems

Before testing a cable pair the following procedure should be followed:


 Remove any telecommunications equipment from both ends.
 Avoid actual contact with the conductors of the pairs where possible.
 With a voltmeter, check that no stray DC or AC voltages are present on the pair.
 Test between legs and each leg to earth. If a hazardous voltage is detected, the pair
should be isolated and expert assistance obtained.
 Discharge any stray capacitive charges by briefly short circuiting the legs of the pair
together and to earth with an insulated wire, avoiding actual contact with the conductors
of the pair where possible.
 Test telephones – Buttinski’s Test telephones are similar in operation to normal
telephones. They are portable and used to check the operation of telephone circuits. Test
telephones are robust and conveniently shaped and usually have additional features to
normal telephones. These features of test telephones include monitoring facilities,
polarity testing and earth recall. Test telephones are often called “Buttinski’s” or “Butts”
for short. This name derives from their ability to “butt in” on telephone lines.
The following best practices are recommended during the installation of cables:
 Install higher cable categories to meet the application requirements that may arise in the
future.
 Use thin and high-density cables as necessary to enable more cable runs in tight spaces.
 Use modular cabling systems to map the ports from equipment with high density port
counts.
 Avoid leaving loose cables on the floor, as this could constitute as a major safety hazard.
Instead, use the vertical, horizontal, or overhead cable managers.
 Store a few spare patch cables. The type and quantity of the patch cables can be
determined from the installation and projected growth. Ensure to store all the unused
cables in a bagged and capped condition when not in use.
 Use the patch cable of exact length, and leave some slack at each end for end device
movements.
 Use vertical and horizontal cable guides for routing cables within and between the racks.
 Use cable spool devices in the cable managers to prevent kinks and sharp bends in the
cable.
 Bundle the related cables together in groups (for example, bundle the ISL cables and
uplinks to their core devices), as this eases management and troubleshooting.
 Use the Velcro-based ties every 1 to 2 meters for bundling or securing the cables, and
avoid using the zip ties as they apply pressure on the cables.
 Regularly maintain the cabling documentation, labeling, and physical or logical cabling
diagrams.
Testing of the completed installation
The generic cabling system should be inspected and tested after completion to ensure that:
 there are no open circuits
 there are no short circuits
 all sockets are correctly terminated
 the CCP is correctly labeled
 TO sockets are correctly colour-coded or labelled in relation to the CCP colour-coding or
labeling
 end-user information is clear, concise and corresponds to the actual installation
 the “as-built” cabling plan is neat and accurate.
3.11 Direction for non-routine events

Qualifications of Installer

The Structured Cabling System shall be installed only by accredited firms of the cabling system
components and by suitable qualified personnel(s)

a) Cabling system installation shall be performed in a safe manner.


b) Personnel undertaking installation works shall be equipped with appropriate personal
protection equipment, tools and mechanical aids.
c) Appropriate barriers and warning signs shall be used to restrict access and draw attention to
potential hazards such as open trenches and the like.
Best Practices
The following best practices are recommended during the installation of cables
 Install higher cable categories to meet the application requirements that may arise in the
future.
 Use thin and high-density cables as necessary to enable more cable runs in tight spaces.
 Use modular cabling systems to map the ports from equipment with high density port
counts.
 Avoid leaving loose cables on the floor, as this could constitute as a major safety hazard.
Instead, use the vertical, horizontal, or overhead cable managers.
 Store a few spare patch cables. The type and quantity of the patch cables can be
determined from the installation and projected growth. Ensure to store all the unused
cables in a bagged and capped condition when not in use.
 Use the patch cable of exact length, and leave some slack at each end for end device
movements.
 Use vertical and horizontal cable guides for routing cables within and between the racks.
 Use cable spool devices in the cable managers to prevent kinks and sharp bends in the
cable.
 Bundle the related cables together in groups (for example, bundle the ISL cables and
uplinks to their core devices), as this eases management and troubleshooting.

 Use the Velcro-based ties every 1 to 2 meters for bundling or securing the cables, and
avoid using the zip ties as they apply pressure on the cables.
 Regularly maintain the cabling documentation, labeling, and physical or logical cabling
diagrams.
• Document and regularly update all the cabling components and their mapping.
 For new installations or re-cabling of the existing equipment, install the cable guides to
reduce mechanical stress and bending of the data cables, and to enhance the
maintainability.
The installation and usage of cable guides should be independent of the number of cables that are
installed. However, there are products that do use cable guides, or where the cable guides cannot
be installed.
3.12 Routine quality termination of cables and devices

Locate your wire distribution device (connector block) at your demarcation point;
• Disconnect one pair of wires from the distribution device;
• Check to see if your service has been restored at other jack locations in your home;
• Continue disconnecting wire pairs, one pair at a time, to determine which wire is the cause of
the trouble;

Once you have isolated the problem circuit, it is suggested that you replace the entire section of
wire that is defective or the jack if it is causing the problem.
If you are unable to repair or isolate an inside wire trouble yourself, repair service is available
from your local telephone company or an independent contractor.

Self-Check -3
Directions: Answer all the questions listed below. Use the Answer sheet provided in the
next page:
Part I. Choose the best answer from the question below
1. ________________is a type of transmission line, used to carry high-frequency electrical
signals with low losses.
A. Coaxial cable B. UTP cable C. Telephone wire D. none
2. To prevent crosstalk, wire pairs in a Cat5e cable should not be untwisted more
than_____ inches.
A. 0.5 B. 0.4 C. 0.45 D. 0.375
3. To prevent crosstalk, wire pairs in a Cat6 cables should not be untwisted more
than_____ inches.
A. 0.375 B. 0.5 C. 0.35 D. 0.475
4. Which of the following colour is used for earthing conductors for CES
system?
A. green/yellow insulation B. blue/yellow insulation C. white/yellow insulation
5. ____________is one of the most important specifications for high-speed networks.
A. Crosstalk B. Attenuation C. Dead air D. Humming

Part II. Fill the blank for the following question

1. ____________is the most basic test for twisted-pair cables.


2. All conductors have a________________ specification, expressed in ohms per meter.
3. ______________ and _____________________ systems that are required to be grounded
must be connected to the earth.
4. _____________________is a designed to test the resistance of the protective earth of
an appliance and/or the supply lead.
5. __________________ refers to an intentional connection to earth through a ground
connection of sufficiently low impedance.

Operation sheet 3

Operation Title: Identifying data cables for socket outlet connection.

Instruction: Using the Flip chart and given equipments Identifying material Used in data cable
for socket outlet connection instructor must check the connection after you
finished connection .

Purpose: When you have completed this Unit, the trainee should be able to identify the material
used in data cable for socket outlet connection.

Required tools and equipment: unit one of this module, tools from workshops like Jacket stripper,
Punch-down tool, Wire cutters, testing instrument.

Precautions: Safe handling Jacket stripper, Punch-down tool, Wire cutters, testing instrument and
components

Procedures:

Step 1: Properly identify data cables for socket outlet connection

Step 2: Prepare materialfor the given task


Quality criteria: Reading the circuit properly, safety procedures were followed & all hand tools
were cleaned

LAP Test 3

Name: __________________________ Date: ____________


Time started: ____________________ Time finished: _______________

Instruction I: Given necessary templates, tools and materials you are required to perform the following
tasks within 2 hours.
Task 1: Identify data cables for socket outlet connectiondevices properly

Task 2- Prepare material for the given task


Unit four: Complete cabling work, records and reporting
This learning unit is developed to provide the trainees the necessary information regarding the
following content coverage and topics:

 OHS work completion risk control measures and procedures

 Work site safety

 record sheets and plans of cable

 cable pair record books


 Documentation and report of cabling completion
This unit will also assist you to attain the learning outcomes stated in the cover page.
Specifically, upon completion of this learning guide, you will be able to:

 FollowOHS work completion risk control measures and procedures

 ClearWork site safety

 Create or updaterecord sheets and plans of cable

 Create /updatecable pair record books


 Prepare Document and report of cabling completion
4.1 OHS work completion risk control measures and procedures

4.1.1 Occupational Health and Safety (OHS)


The Installer shall comply with all rules and Regulations, Approved Codes of Practice, all
relevant Standards, Work Safe. Guidelines, Occupational Health and Safety requirements,
accepted codes of practice, manufacturer’s instructions and any temporary rules and restrictions
that may be in force at the time. The installer shall also comply with the collage and Ministry of
Education Health and Safety policy ( of the country), guidelines and rules when engaged in work
on Ministry of Education sites and equipment, and shall confirm to all site specific requirements
including safety requirements. Prior to the commencement of any design or construction work on
collage property involving access to grounds or buildings the installer shall ensure they have
received:
a) A copy of the collage safety plan, including the location of collage safety and first-aid
equipment
b) A collage vehicle access plan including safe access and parking for cabler and delivery
vehicles
The installer shall ensure that all its personnel working on collage of vocational Education or
working on laboratory safe working on networks have undertaken appropriate training and have
a Recognized site safety accreditation for both the site and work to be undertaken at practical
training time. No open pits, holes, trenches, or access areas, are to be left unattended at any time.
All are to be clearly marked and secured in accordance with OSH regulations and all ground or
structural disturbances are to be secured and/or removed at the end of each day’s work in
accordance with OSH regulations.
Cable Management in the Workplace.
Trailing cables can be very costly around half the UK’s working population work in offices
(1) Expecting environments to be safe, healthy and comfortable, yet efficient and productive
also. This trust has for some years been challenged by a variety of pressures which have
squeezed personal space
(2) - while, at the same time, cables have proliferated. Each of these trends has significant
consequences, but when combined they can impact on health & safety, and ergonomic planning,
to makeable management a critical issue which requires a pro-active and responsible approach.
It is not always possible to route cables neatly along walls, using trunking; above suspended
ceilings and down power poles, or under raised floors; to integrate desk electrics, or locate
workstations closer to power supplies to minimize the lengths of trailing cables. More often
cables are all around us and under our feet! We’ve more electrical equipment and wired
appliances than ever before - the typical workstation will have at least six cables - so the average
UK office worker today accounts for over twenty metres of exposed cabling.

Figure4. 1 typical work station and cord without cover which make electrical hazard

It is important to consider how a trip can be exacerbated by crashing on an awkward


surface, such as a desk-edge, copier or filing cabinet; a danger made more acute for employees
in tight work areas. Recently in the UK there have been significant compensations paid to trip-
victims who have suffered fractures, dislocations, loss of earnings, facial scarring
disfigurements, fractured skulls and brain injury. On average two people per year die as a result
of a slip, trip or fall at work.

Figure4. 2 accident of brain injury


The HSE guide ‘Preventing slips and trips at work’ spells out the duty of employers…
The Health & Safety at Work Act 1974 (HSW Act)requires all employers to ensure the health &
safety of all employees and anyone who may be affected by their work, so far as is reasonably
practicable. This includes taking steps to address trip risks.
The HSW Act also states ‘Employees have a duty not to put themselves or others in danger’. A
robust Health & Safety policy should make an example that employees do not leave cables
trailing as a danger to their fellow workers, and that any breach is reported immediately.
The Workplace (Health, Safety and Welfare) Regulations 1992require floors to be
Suitable, in good condition and free from obstructions. People should be able to move around
safely. The Management of Health & Safety at Work Regulations 1999 require employers to
assess risks (including trip hazards) and, where necessary, take action to address them.
In all instances, specific references are made to trip and fall risks posed by trailing cables. Also
that ‘cables, plugs, sockets and fittings must be robust enough and adequately protected for the
working environment’
4.1.2 Cable Tidy Units
‘To comply with health & safety legislation and for best practice, containingextension
blocks in Cable Tidy Units under desks makes common sense - and a realdifference!’ Safety
Overloading socket outlets, especially socket extensions cancause excessive heat buildup and is a
major cause of fires from electricity.
Floor boxes fitted in screed or cavity floors can provide 13amp 240v socket outlets plus
telephone and data points, but, where the workstations using that box require additional
socket outlets, adding socket extension blocks is the most popular solution. A danger arises
if these extension blocks are overloaded.
Figure4. 3A danger arises if these extension blocks are overloaded.

Most socket extensions are rated 13A (3120w capacity), but many have only 10A (1800w
capacity), or even lower rating. Plugging-in most popular desk equipment should not pose a
problem; laptops and desktop computers generally consume less than 250w each. Note printers
can use up to 800w during printing. While employers might prohibit the use of personal
electric appliances - a kettle or personal heater can eachconsume 3000w, so would instantly
overload and blow the fuse of an extension block - there remains a more serious risk if
employees wanting yet more outletsdecide to plug a second extension block into the first one,
so increasing the risk of overheating; or plug an adaptor into an extension block,
especially as blocky-type adaptors are usually unfused. Accepting the danger of a breach in
H&S policy, putting each rectangular-style socket extension block inside a D-Line Cable Tidy
Unit represents a practical way to reduce such risk; making the socket block lessaccessible or
less inviting to employees, and an adaptor more awkward to fit.

Figure 4. 4 enclosing the extension block reduce the possibility of any drink spill on to live
sockets.
It should be considered that however small the risk assessed, enclosing the extension block
reduces the possibility of any drink spill on to live sockets. While circuit protection should be
effective, all steps should be taken to avoid the surge and heat that can arise should liquids
(conductive) contact with electricity.
Similarly best practice should consider that when copper cables are fully loaded and form a tight
coil to nest around an extension block, some cables can be fully entrapped so their heat cannot
disperse; a danger eliminated by using Cable Tidy Units (note 17th Edition of IET Wiring
Regulations state in BS7671:2008 section Cable
Enclosures that when containing pvc insulated cables ‘not more than 45% of space within a
conduit or trunking must be occupied by cables’; a principle transferable to Cable Tidy Units).
Cable Tidy Units should provide ample space, and require also that the cable from each plug-top
must be routed via one of the three rear exit slots… so further minimizing risks from ‘excessive’
heat build-up. These slotted exits are vents also. Entry and exit cables should be concealed in
D-Line Spiral Wrap, Cable Tidy Tubes or Trunking. D-Line Cable Tidy Units are produced in
the UK using electrically safe material, and have been fully safety tested (when overloaded with
cables, and vents blocked!)

Figure4. 5Cable Tidy Units

4.1.3 Split insulation, and damaged conductors


Frayed or split insulation on power cables give a leakage point for current to electrocute. At
worst a shock of 240v can be fatal. A similar risk occurs if cables are pulled to strain or loosen a
termination point, to leave either an exposed ‘live’ conductor or broken conductor strands.

Figure4. 6 Risk occurs if ‘live’ conductor or broken conductor strands.

Broken conductor strands disrupt the natural flow of current, creating resistance by forcing high
wattages over a smaller conductor area, and, over periods, where perhaps power is on 24/7,
excessive heat builds up. Becoming glowingly-hot can ignite common office materials such as
paper and waste, to start a fire.
Cable management products — that can protect insulation; stop cords twisting and knotting; and
prevent tugs and pulls — are a small price-to-pay for safeguarding from the worst consequences.

Figure4. 7 Cable management before and after in office

4.1.4. Desk Trunking or Wire Basket trays


- D-Line Desk Trunking is produced from self-extinguishing pvc which can easily be cut with a
junior hacksaw. A reliable self-adhesive backing enables quick peel-and-stick installation to a
desk, for example up a desk-leg, vertically from a Cable Tidy Unit up a rear panel, or
horizontally between grommet exits on the desk-top. The click-lock lid makes it easy to add or
remove cables; while the half-round shape and hinge-effect combine to make D-Line Desk
Trunking gentler on impact.
- By comparison Wire Basket trays require screw-fixing; are not suited to bespoke sizing; are
more prone to snagging and more awkward on impact if knocked.

Figure4. 8 Desk Trunking or Wire Basket trays

4. 1.5. How to choose Floor Cable Protectors


- The Floor Cable Cover should be sufficiently long to cover the full length of cable(s)across the
floor.
- Where a longer length is required, any link to a subsequent strip should be mechanically secure
to avoid the run breaking in the event of a kick or knock.
Note D-Line’s Medium Duty profiles can uniquely be joined by patent-pending push-in pull-out
connector rods that fit the continuous grip- holes along the lengths so the runs can be as long as
needed… 50 metres+ if necessary. The lengths can be cut too, so continuous runs can
perfectly match the requirement.
Figure4. 9 continuous runs can perfectly match the requirement
- The Floor Cable Cover must not itself be a trip hazard!
• This means it should have a tapered design, and not a sharp kerb-effect that could be potentially
obtrusive
• The strip must be able to lie flat on the floor. Beware versions that are overly stiff, prone to curl
or twist and never uncoil to lie flat
• Avoid alternatives that are overly thin and flimsy, too lightweight to lay flat and vulnerable to
movement after minor knocks
- Consider the size and volume of cables that need to be covered, then select a Floor Cable Cover
with a cavity-size that can accommodate the relevant cables.

Figure4. 10 select a Floor Cable Cover with a cavity-size that can accommodate the relevant
cables
Mains voltage and low-voltage cables should be segregated in a compartmentalized profile.
- Value-added features such as a ribbed back can make a strip less likely to slip after being
knocked. Likewise a pre-split rear cavity makes it quick and easy to fit the strip over the cables.
Caution 1 - if preferred, after inserting cables, users can affix Floor Cable Covers to a floor by
applying heavy-duty double-sided tape. Take care to ensure the floor is clean and dry so an
effective bond can be made.
Beware such tapes may leave a residue on removal.
Caution 2 - do not put cables under carpet tiles, or under surface tapes. This will provide less
protection for the cable, with a greater likelihood that ‘wear’ will lead to a ‘tear’ in the outer
sheath of the cable, especially any thin rubberized insulation.
- Using only a tape will not offer the same protection against the cable becoming frayed, or
pinched under the leg of a chair or desk. As previously, beware the electrocution risk of exposed
conductors and how brokenconductors can lead to power failures, heat build-ups and fires.

Figure4. 11 beware the electrocution risk of exposed conductors and covered conductors

4.1.6. Make your work place cable-safe!


Figure4. 12 Make your work place cable-safe!

Advice
The installer(students)shall advise his teacher for the gain approval before undertaking any work
at the practical workstation or on site follow up ,that may or will result in voice, data, security or
other ICT network service disruption or network downtime to existing network infrastructure.
Any work that may result in network down time will require scheduling with school
representatives
4.2Work site safety
Site conditions
The installer shall familiarize themselves with the site conditions prior to undertaking or
providing quote or estimate prices for any work. Specific conditions to be observed at collage
work station during practical session or on site work of cablings OSH requirements, qualification
and identification of personnel and onsite legacy equipment and configurations. Installers are
required to undertake all necessary investigations to fully inform themselves of the site
conditions and other factors that could impact the cost and execution of works
This includes but is not restricted to:
A. Hazards that may be present at the collage practical work station or onsite cabling
B. Heritage registration of buildings
C. Environmental conditions including special precautions for the protection of flora and fauna
D. Local site conditions including weather hazards and cultural significance
E. Easements
F. Safety of students and staff with respect to pit covers and location
G. Existing and projected underground services, note that site maps may not be complete or
available
4.3 Record sheets and plans of cable
The record sheets are generally established and maintained by the carrier or installer
(supervisor) of the cable installation. Network jumpers, distribution line, mainline, color
code mark ,identification at each terminal that is input and output all these and the ext.
connection records will be recorded and established on the sheet and provided for owner and
set for future extension or remove and add
Please note that this frame does/ does not leave each 11th module position blank
Termination records-----------------
Records correct as of______________sheet______________________
4.4Cable pair record books
Creating Cable pair record books to provide accurate record information
In an installation of data cable, Telephone cable, coaxial cable, CCTV- cable, Fiber optics and all
other cable for signal transfer whether for high or low speed Planning is the first critical issue
that discussed at first of all. By doing this all data survey of the area, environment, length, type
of the building and all other information required to for the routing of the cable must be
organized each step by step for the next removal, addition, re installation of the existing or for
new construction of the system, all this records are recorded to the book form for the next option
of constructing to much the coming technology or for better decision of the cost, louber ,
management analysis.
4.5. Documentation and report completion of installing work

A comprehensive strategy for managing power and data cables within IT racks in
telecommunication is critical for the uptime, safety, and cooling efficiency of data centers.
Advancements in IT rack designs have improved power and data cable management
(documentation):
Effective rack power and data cable management leads to a number of IT infrastructure Benefits
including: Enhanced availability through reduced downtime. A system operator or employee can
be easily confused by a mess of cables, which often results in human error. Human error is
widely regarded as the leading cause of data center downtime based on a study by The Uptime
Institute
 Effective cable management can help system operators to manage cables and IT devices
easily, so as to reduce human error.
 Improved system performance through reduced crosstalk and interference between
power and data cables. Power and data cables in close proximity to each other can
create electromagnetic interference (EMI), which can result in erratic or error-prone
data transfer in network cables. Cable management tends to separate power and data
cables within the racks, which can help reduce the risk of interference.
 Improved maintenance and serviceability by allowing easier and safer access to
individual components.
 Increased cooling efficiency by allowing hot exhaust air to escape out the back of the
rack. Cable management keeps cables organized and out of critical airflow paths.
 Improved scalability by simplifying moves, adds, and changes. Cable management can
make it easier to integrate additional racks and components in the future as the data
center grows
This documentation or guidance on power and data cable management that will improve
Physical appearance, cable traceability, airflow, cooling efficiency, and troubleshooting time
while reducing the risk of human error. Following the steps outlined below can help you achieve
a clean and well organized data center(documentation):
 Plan
 Determine the routes for power and data cables
 Identify cables
 Route and retain cables
 Secure cables and connectors
 Avoid thermal issues
 Document and maintain organization
Plan
Planning is the first step for power and data cable management in IT racks, and when done
properly, it facilitates all of the steps below. Planning plays a critical role in any successful cable
management project. If this is your first structured cabling project, we recommend that you hire
a professional cab ling contractor like Schneider Electric to complete the entire project. Table
below shows an example statement of work (SOW) for cable management in documentation. A
key output of the planning step is to determine the number of cables needed. This is done by
calculating the number and type of connections per device and the total number of devices

Activities Description
Management will provide cable management for the servers migrating over to the
new racks in existing and for new installation
will dress cabling into neat and presentable bundles in all locations Install
Installation will install and manage all patch cords into the rack and organize them
with a specific cable management system that allows for proper airflow in
the rack
Labels will professionally label primary and secondary data cables, and primary
and secondary power cables.
Logistics will provide the knowledge and labor required for a well-organized
and professionally maintained data center with minimal downtime.
will utilize a fully tested cable management system.

Activities Description
Advanced coppertesting will physically test each port from the Data Distribution Cables
(DDC) to the switch for compliance to current standards, with
customer approval.
will use a network cabling certification tester, compliant to
TIA/EIA TSB67 Level III specifications.
Advanced crossover and install and manage all patch cords into the rack and organize them
strait through(wide- with a specific cable management system that allows for proper
networkng) airflow in the rack
Basic copper testing Perform a continuity port test and wire map of each port of the
cables (digital mult meter)
Basic coaxial testing Coaxial cable testing

Cabling System Documentation

The most often overlooked item during cable installation is the documentation of the new cabling
system. Cabling system documentation includes information about what components make up a
cabling system, how it is put together, and where to find individual cables.
This information is compiled in a set of documents that can be referred to by the network
administrator or cabling installer any time moves, adds, or changes need to be made to the
cabling system.
The most useful piece of cabling system documentation is the cabling map. Just as its name
implies, a cabling map indicates where every cable starts and ends. It also indicates
approximately where each cable runs. Additionally, a cabling map can indicate the location of
workstations, segments, hubs, routers, closets, and other cabling devices. To make an efficient
cabling map, you need to have specific numbers for all parts of your cabling system. For
example, a single cable run from a cabling closet to wall plate should have the same number on
the patch panel port, patch cable, wall cable, and wall plate. This way, you can refer to a specific
run of cable at any point in the system, and you can put numbers on the cabling map to refer to
each individual cable run.

Self-Check -4
Directions: Answer all the questions listed below. Use the Answer sheet provided in the
next page:
Part I. Choose the best answer from the question below

1. Which of the following must be robust enough and adequately protected for the working
environment?
A. Cables B. Plugs C. sockets D. fittings E. all
2. The telecommunication and data service Installer shall comply with_______________
A. all rules and Regulations C. Approved Codes of Practice,
B. All relevant Standards D. Work Safe E. all
3. Safety Overloading socket outlets, especially socket extensions can cause excessive heat
buildup and is a major cause of ___________ from electricity.
A. Overload B. fire C. burn D. heat
4. The record sheets of cables are generally established and maintained by the
______________of the cable installation.
A. carrier or installer B. technician C. Manager D. shopkeeper
5. In creating data book for information about cable installed.
A. Planning is the first pinot of view. C.Condition of the area
B. Information analysis of environmentD. All
6. The cable record book is used for_________
A. Adding cable to the existing C. For extension of the existing

B. For removal of the installed cable D. All of the above

Part II. If statement correct write True and if statement is incorrect write False for the
following question.

1. Record sheet controlling is the mandate of electrical.


2. The owners the network can manage data power cable using the record sheet.
3. The installer shall familiarize themselves with the site conditions prior to undertaking or
providing quote or estimate prices for any work.
4. Installers are required to undertake all necessary investigations to fully
Inform themselves of the site conditions.

.
References

 Refer to Australian Standard AS/CA S009:2013, Installation requirements for customer


cabling (Wiring rules).
 Using Anixter’s online catalog at anixter .com/catalog.
 From AS/CA S009:2013 Appendix F.2,: From AS/CA S009:2013)
 www.telstra.com.au/customer-terms/
 http://www.schneider-electric.com/ww/en/download/document/APC_TESS-
6W9KFF_R1_EN_SRC?showAsIframe=true&xtmc=cable%20management
%20statement&xtcr=1
 (https://www.armypubs.army.mil),and the Central Army Registry site
(https://atiam.train.army.mil/catalog/dashboard).
 Cabling. Part 2, Fiber-optic cabling and components ( PDFDrive )
 cabling_-_the_complete_guide_to_network_wiring_2nd_ed_malestrom.David Groth Jim
McBee David Barnett
 Advances in Signal and Data Processing Select Proceedings of ICSDP 2019 (0009172) (z-
lib.org)
Developer profile

Qualificatio Organization/
No Name Field of Study Region Mobile number E-mail
n (Level) Institution
Industrial Automation Lideta
Mengistu
1 MSc & Control A.A Manufacturing 0913948480 [email protected]
Abiyu
Management College
Industrial Automation
2 Samuel Bekele MSc & Control Oromia Haramaya PTC 910082977 [email protected]
Management
Yidnekachew Electrical Automation
3 BSc A.A Akaki PTC 920137899 [email protected]
Seboka & Control Technology
Electrical Automation Addis
4 Zegeye Girma BSc A.A 926805563 [email protected]
& Control Technology KetemaIn.College
Industrial Automation
HawassaTegibarid
5 Bacha Wake MSc & Control Sidama 987065251 [email protected]