Mass Timber Pipe Penetration Var. 2

The document provides details on mass timber pipe penetrations with ROFLEX, including diagrams showing the system components and their layout. It includes notes that non-combustible insulation may be required by local regulations and that engineering design should be signed off.

Uploaded by

dean
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
39 views2 pages

Mass Timber Pipe Penetration Var. 2

The document provides details on mass timber pipe penetrations with ROFLEX, including diagrams showing the system components and their layout. It includes notes that non-combustible insulation may be required by local regulations and that engineering design should be signed off.

Uploaded by

dean
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

W2151-1 Pro Clima - Mass Timber Pipe Penetration

With ROFLEX

Scale 1:10 @ A4 paper

Ventilated tile

Pipe-gromit pro clima


ROFLEX
Min. 20mm
pro clima
TESCON EXTORA®

Cavity (min. 20mm)

Wide width batten : 70mm


wide timber or similar width metal batten
when used over semi rigid fibrous
insulation

pliable building membrane


(underlay), pro clima
SOLITEX MENTO® family

Vapour permeable fibrous insulation*

Full-surface adhesive air


sealing membrane with pro clima
SOLITEX EXTASANA ADHERO®

Cross laminated timber

Optional insulated
service cavity (45mm)

*Notes:
1) Non-combustible insulation types may be required by local regulations.

1 of 2
Title: Mass Timber Pipe
With ROFLEX
ID: W2151-1 Issued: 29/03/2023 Revision:
© This drawing is the property of Pro Clima NZ Ltd &/or Pro Clima Australia Pty Ltd and must not be copied without permission. This drawing is a guideline only and subject to change without notice.
Thermal and hygrothermal performance should match specific design, materials and climate requirements. These can be confirmed by hygrothermal analysis using software e.g. WUFI®. Structural, fire and
www.proclima.co.nz acoustic engineering design and the incorporation of building services (plumbing and electrical) should be signed-off by a suitably qualified engineer to ensure compliance with all health and safety
www.proclima.com.au requirements.
W2151-2 Pro Clima - Mass Timber Pipe Penetration - 3D
With ROFLEX

Scale 1:10 @ A4 paper

Wide width batten : 70mm


wide timber or similar width
metal batten when used over
semi rigid fibrous insulation

pliable building membrane


(underlay), pro clima
SOLITEX MENTO® family

Pro clima
TESCON EXTORA®

Pipe-gromit pro clima


ROFLEX

Vapour permeable
fibrous insulation*

Full-surface adhesive air


sealing membrane with pro
clima SOLITEX EXTASANA
ADHERO®

*Notes:
1) Non-combustible insulation types may be required by local regulations.

2 of 2
Title: Mass Timber Pipe - 3D
With ROFLEX
ID: W2151-2 Issued: 29/03/2023 Revision:
© This drawing is the property of Pro Clima NZ Ltd &/or Pro Clima Australia Pty Ltd and must not be copied without permission. This drawing is a guideline only and subject to change without notice.
Thermal and hygrothermal performance should match specific design, materials and climate requirements. These can be confirmed by hygrothermal analysis using software e.g. WUFI®. Structural, fire and
www.proclima.co.nz acoustic engineering design and the incorporation of building services (plumbing and electrical) should be signed-off by a suitably qualified engineer to ensure compliance with all health and safety
www.proclima.com.au requirements.

You might also like