0% found this document useful (0 votes)
38 views

Filters For Musk

This datasheet provides information on EasyLock filters that protect against gases, vapors, and dust for Moldex respirator masks, including specifications for gas and particulate filter classes and models, materials used, certifications, service life, and proper usage guidelines. The filters can be directly attached to mask bodies or combined in pre-assembled units for simplicity, and offer pleated filter technology for low breathing resistance.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
38 views

Filters For Musk

This datasheet provides information on EasyLock filters that protect against gases, vapors, and dust for Moldex respirator masks, including specifications for gas and particulate filter classes and models, materials used, certifications, service life, and proper usage guidelines. The filters can be directly attached to mask bodies or combined in pre-assembled units for simplicity, and offer pleated filter technology for low breathing resistance.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

DATASH EE T

EASYL CK® F I L T E R S
PROTECTION AGAINST GAS, VAPOUR & DUST

FOR SERIES 70 0 0 AND 90 0 0 MASKS


Gas filters Particulate filters Pre-assembled filters
9100 A1 9500 A2B2E1 9010 P1 R 9120 A1P2 R
9200 A2 9600 AX 9020 P2 R 9230 A2P3 R
9300 ABE1 9800 ABEK2 9022 P2 R+Ozone 9430 ABEK1P3 R
9400 ABEK1 9030 P3 R 9730 ABEK1HgP3 R D
9032 P3 R+Ozone

EASYL CK® F I L T E R S Y S T E M

CHARACTERISTICS MATERIAL

· Particulate filters can either be directly combined with the EasyLock® gas Particulate filter: Polypropylene
cartridges or directly connected with the mask body. Particulate filter 9022, 9032: Polypropylene, activated carbon
· Easy handling as no adapters or particulate filter holders are necessary Particulate filter holder: Polypropylene
with the Moldex EasyLock® -System. Gas filter: Activated carbon
· The unique Moldex Pleated Filter Technology reduces breathing resistance Gas filter cartridge: Polystyrene
and considerably increases the capacity of the particulate filters.
· The pre-assembled filter combinations offer the simplicity of combined WEIGHT (APIECE)
filters and are more economical at the same time due to exchangeable
pre-filters. 9100: 66 g 9600: 112 g 9030: 30 g 9730: 127 g
· Simpler logistics, on average 30% less parts are required with the 9200: 87 g 9800: 130 g 9032: 27 g
EasyLock® -System. 9300: 67 g 9010: 18 g 9120: 84 g
· 100% PVC-FREE: All Moldex products and packaging are 100% PVC-free 9400: 92 g 9020: 18 g 9230: 117 g
9500: 109 g 9022: 24 g 9430: 122 g

CERTIFIC ATION I M P O R TA N T I N FO R M AT I O N FO R U S E R S

The EasyLock® filters meet the requirements of EN 14387:2004+ A1:2008 and · The mask and the filters must be selected in accordance with the
EN 143:2000 + A1:2006 and are CE-marked in accordance with the require­ pollutant concentration. (see tables 1,2 and 3)
ments of European Directive 89/686 EEC. The Institut für Arbeitsschutz IFA in · In the case of gases with insufficient warning properties, filters may only
St Augustin (0121) in Germany is the body responsible for both type examina- be used if special usage policies are specified for this purpose.
tion (article 10) and monitoring of products (article 11B). The products are · If the conditions are uncertain or changeable, a self-contained breathing
manufactured in an ISO 9001 certified plant. apparatus must be worn.
· The product does not contain any metallic parts that could cause ignition
in potentially explosive atmospheres.

WWW.MOLDEX-EUROPE.COM
GB 03-16
DATASH EE T
EASYL CK® F I L T E R S
PROTECTION AGAINST GAS, VAPOUR & DUST

SERVICE LIFE OF THE CARTRIDGES PARTICULATE FILTER CLASS


AND PARTICULATE FILTERS E N 14 3 : 2 0 0 0 + A 1 : 2 0 0 6 table 3

If you can smell gases or vapours when you use the gas filters, they are Class Maximum use level with Maximum use level with
exhausted and must be replaced (no later than 6 months after the original halfmask Series 7000 fullmask Series 9000
packaging is opened). Replace the particulate filter if the breathing
resistance increases dramatically. The filters must always be replaced in P1 R 4 x WEL * 4 x WEL *
pairs. You must adhere to the use-by-date. Fine dusts, fumes, water and oil based mists/aerosols
P2 R 10 x WEL * 10 x WEL *
STORAGE
Keep the filters sealed in a dry, uncontaminated environment. Protect them Hazardous fine dusts, water and oil based mists/aerosols,
against sunlight and sources of heat. Biological agents of risk group 2
P3 R 20 x WEL * 40 x WEL *
F I LT E R S Q UA L I F Y A S H A Z A R D O U S WA S T E
They must be disposed of in accordance with the applicable waste disposal Harmful and carcinogenic dusts, water and oil based mists/
regulations. Information is provided by your local responsible authority. aerosols, biological agents of risk group 2 and 3,
CMR-substances
P2 R + P3 R In addition to the particle filtering efficiency these filters also
G A S F I LT E R M O D E L E N 14 3 8 7 table 1 + Ozone offer protection against ozone; at 1000ppb ozone a maximum
use time of 8h.
Model Colour Area of application
A Brown Organic gases and vapours, boiling point > 65°C
* WEL = Workplace Exposure Limit
B Grey Inorganic gases and vapours R: The filters are reusable.
E Yellow Acid gases (e.g. sulphur dioxide, hydrochloric acid)
K Green Ammonia
Due to the low weight of filters of less than 150 g per filter (-combination) all
AX Brown Organic vapours boiling point ≤ 65°C filters can be used for both, the full face mask and the half mask.
Hg P3 Red-White Mercury Exception: Art.No. 9800 ABEK2 combined with 9030 P3 or 9020 P2 particu-
late filters is intended to be used with full face mask only.
CAUTION: AX filters must only be used once. Low-boiling gases (≤ 65°C)
generally bind poorly with gas filters. This may result in shorter periods in
service. Please refer to the relevant national regulations for information Quality control and EC type-approval office:
about the maximum permissible application concentrations and times for the IFA; Identification number: 0121; 53757 Sankt Augustin; Germany
individual compounds. Only use with vapours with good warning properties.

AX filters do not offer adequate protection against various low-boiling gases.


If you have any questions about how to use AX filters, please contact Moldex.

The filter 9730 ABEK1Hg P3 have a maximum use time of 50h against mercury.

G A S F I LT E R C L A S S E N 14 3 8 7 table 2

Class Maximum use level with Maximum use level with


half mask Series 7000 full face mask Series 9000 INFO
1 1000 ppm (0.1 percent by 1000 ppm (0.1 percent by For help on selection and training please contact us.
volume) or 10 x WEL* volume) or 20 x WEL* We offer a wide range of training packages and support material.
2 5000 ppm (0.5 percent by 5000 ppm (0.5 percent by MOLDEX-METRIC AG & Co. KG Tel.: +44 (0)115 985 4288
volume) or 10 x WEL* volume) or 20 x WEL* Unit 9, Glaisdale Point Fax: +44 (0)115 985 4211
Off Glaisdale Drive, Bilborough [email protected]
* WEL = Workplace Exposure Limit
Nottingham. NG8 4GP www.moldex-europe.com
whichever is lower

WWW.MOLDEX-EUROPE.COM