0% found this document useful (0 votes)
89 views

STEP 7 - New Modules

This document provides information on new modules for SIMATIC 300, SIMATIC 400, and ET 200pro systems supported in STEP 7 V5.7 SP1. It lists the product name, identification number, firmware version, and a brief description for each module, including CPUs with various processing speeds and memory sizes for PROFINET, PROFIsafe, and redundancy capabilities.

Uploaded by

nidohoc110
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
89 views

STEP 7 - New Modules

This document provides information on new modules for SIMATIC 300, SIMATIC 400, and ET 200pro systems supported in STEP 7 V5.7 SP1. It lists the product name, identification number, firmware version, and a brief description for each module, including CPUs with various processing speeds and memory sizes for PROFINET, PROFIsafe, and redundancy capabilities.

Uploaded by

nidohoc110
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

New Modules STEP 7 V5.

7 SP1

Product MLFB FW- Short Description


Version

SIMATIC 300
CPU 314C-2 PN/DP 6ES7 314-6EH04-0AB0 V3.3.18 SNMP configurable (default disabled); Work memory 192KB; 0.06ms/1000 instructions;
DI24/DO16; AI5/AO2 integrated; 4 pulse outputs (2.5kHz); 4 channel counting and
measuring with incremental encoders 24V (60kHz); integrated positioning function;
MPI+ DP connector (DP master or DP slave); PROFINET IO-Controller; supports RT/IRT;
PROFINET interface and 2 ports; MRP; multi-tier configuration up to 31 modules; send and
receive capability for direct data exchange; constant bus cycle time; routing;
S7 Communication (loadable FBs/FCs); firmware V3.3.18
CPU 315-2 PN/DP 6ES7 315-2EH14-0AB0 V3.2.18 SNMP configurable (default disabled); 384 KB work memory; 0.05ms/1000 instructions;
PROFINET connection; S7 Communication (loadable FBs/FCs); PROFINET IO-Controller;
supports RT/IRT; PROFINET interface and 2 ports; MRP; PROFINET CBA; PROFINET CBA-
Proxy; TCP/IP transport protocol; combined MPI/DP connection (MPI or DP master or
DP slave); multi-tier configuration up to 32 modules; constant DP bus cycle time; routing;
firmware V3.2.18
CPU 315F-2 PN/DP 6ES7 315-2FJ14-0AB0 V3.2.18 SNMP configurable (default disabled); 512 KB work memory; 0.05ms/1000 instructions;
PROFINET connection; S7 Communication (loadable FBs/FCs); PROFINET IO-Controller;
supports RT/IRT; PROFINET interface and 2 ports; MRP; PROFINET CBA; PROFINET CBA-
Proxy; TCP/IP transport protocol; combined MPI/DP connection (MPI or DP master or
DP slave); multi-tier configuration up to 32 modules; constant DP bus cycle time; routing;
firmware V3.2.18, can be used for safety applications; supports PROFIsafe V2
CPU 317-2 PN/DP 6ES7 317-2EK14-0AB0 V3.2.18 SNMP configurable (default disabled); 1024 KB work memory; 0.025ms/1000 instructions;
PROFINET connection; S7 Communication (loadable FBs/FCs); PROFINET IO-Controller;
supports RT/IRT; PROFINET interface and 2 ports; MRP; PROFINET CBA; PROFINET CBA-
Proxy; TCP/IP transport protocol; combined MPI/DP connection (MPI or DP master or
DP slave); multi-tier configuration up to 32 modules; constant DP bus cycle time; routing;
firmware V3.2.18

New Modules STEP 7 V5.7 SP1


11/2022, A5E50957781-AB 1
New Modules STEP 7 V5.7 SP1

SIMATIC 300
CPU 317F-2 PN/DP 6ES7 317-2FK14-0AB0 V3.2.18 SNMP configurable (default disabled); 1536 KB work memory; 0.025ms/1000 instructions;
PROFINET connection; S7 Communication (loadable FBs/FCs); PROFINET IO-Controller;
supports RT/IRT; PROFINET interface and 2 ports; MRP; PROFINET CBA; PROFINET CBA-
Proxy; TCP/IP transport protocol; combined MPI/DP connection (MPI or DP master or
DP slave); multi-tier configuration up to 32 modules; constant DP bus cycle time; routing;
firmware V3.2.18, can be used for safety applications; supports PROFIsafe V2
CPU 319-3 PN/DP 6ES7 318-3EL01-0AB0 V3.2.18 SNMP configurable (default disabled); Work memory 2048KB; 0.004ms/1000 instructions;
PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller;
supports RT/IRT; PROFINET interface and 2 ports; MRP; PROFINET CBA; PROFINET CBA-
Proxy; TCP/IP transport protocol; combined MPI/DP connection (MPI or DP master or
DP slave); multiline structure up to 32 modules; constant DP bus cycle time; routing;
firmware V3.2.18
CPU 319F-3 PN/DP 6ES7 318-3FL01-0AB0 V3.2.18 SNMP configurable (default disabled); Work memory 2560KB; 0.004ms/1000 instructions;
PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller;
supports RT/IRT; PROFINET interface and 2 ports; MRP; PROFINET CBA; PROFINET CBA-
Proxy; TCP/IP transport protocol; combined MPI/DP connection (MPI or DP master or
DP slave); multiline structure up to 32 modules; constant DP bus cycle time; routing;
firmware V3.2.18, can be used for safety applications; supports PROFIsafe V2

New Modules STEP 7 V5.7 SP1


2 11/2022, A5E50957781-AB
New Modules STEP 7 V5.7 SP1

SIMATIC 400
CPU 412-5H PN/DP 6ES7 412-5HK06-0AB0 V6.0.10 Redundant and fail-safe capable, work memory 512KB code and 512KB of data;
31.25 microseconds/1000 instructions; 8KB DI/O; 48 connections; 1*DP/MPI, 1*DP, 1*PN
and 2 receptacles for H Sync modules; PROFINET IO controller; PROFINET interface and
2 ports; supports RT, MRP, system redundancy, PROFIsafe V2; SNMP configurable (default
disabled); firmware V6.0.10
CPU 414-5H PN/DP 6ES7 414-5HM06-0AB0 V6.0.10 Redundant and fail-safe capable, work memory 2MB code and 2MB of data;
18.75 microseconds/1000 instructions; 8KB DI/O; 64 connections; 1*DP/MPI, 1*DP, 1*PN
and 2 receptacles for H Sync modules; PROFINET IO controller; PROFINET interface and
2 ports; supports RT, MRP, system redundancy, PROFIsafe V2; SNMP configurable (default
disabled); firmware V6.0.10
CPU 416-5H PN/DP 6ES7 416-5HS06-0AB0 V6.0.10 Redundant and fail-safe capable, work memory 6MB code and 10MB of data;
12,5 microseconds/1000 instructions; 16KB DI/O; 96 connections; 1*DP/MPI, 1*DP, 1*PN
and 2 receptacles for H Sync modules; PROFINET IO controller; PROFINET interface and
2 ports; supports RT, MRP, system redundancy, PROFIsafe V2; SNMP configurable (default
disabled); firmware V6.0.10
CPU 417-5H PN/DP 6ES7 417-5HT06-0AB0 V6.0.10 Redundant and fail-safe capable, work memory 16MB code and 16MB of data;
7.5 microseconds/1000 instructions; 16KB DI/O; 120 connections; 1*DP/MPI, 1*DP, 1*PN
and 2 receptacles for H Sync modules; PROFINET IO controller; PROFINET interface and
2 ports; supports RT, MRP, system redundancy, PROFIsafe V2; SNMP configurable (default
disabled); firmware V6.0.10

New Modules STEP 7 V5.7 SP1


11/2022, A5E50957781-AB 3
New Modules STEP 7 V5.7 SP1

ET 200pro
IM154-8 PN/DP CPU 6ES7 154-8AB01-0AB0 V3.2.18 SNMP configurable (default disabled); Working memory 384KB; 0.05 ms/1000
instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO
controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET
CBA proxy; transport protocol TCP/IP, UDP and ISO on TCP ; combined MPI/DP connection
(MPI or DP master or DP slave); DP constant bus cycle time; routing; firmware V3.2.18;
expansion with maximum 16 ET200pro spectrum modules
IM154-8F PN/DP CPU 6ES7 154-8FB01-0AB0 V3.2.18 SNMP configurable (default disabled); Working memory 512KB; 0.05 ms/1000
instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO
controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET
CBA proxy; transport protocol TCP/IP, UDP and ISO on TCP ; combined MPI/DP connection
(MPI or DP master or DP slave); DP constant bus cycle time; routing; firmware V3.2.18;
expansion with maximum 16 ET200pro spectrum modules; can be used for safety
applications; supports PROFIsafe V2
IM154-8FX PN/DP CPU 6ES7 154-8FX00-0AB0 V3.2.18 SNMP configurable (default disabled); Work memory 1536Kbytes; 0.025 ms/1000
instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO
controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET
CBA proxy; transport protocol TCP/IP, UDP and ISO on TCP ; combined MPI/DP connection
(MPI or DP master or DP slave); DP constant bus cycle time; routing; firmware V3.2.18;
expansion with maximum 16 ET200pro spectrum modules; can be used for safety
applications; supports PROFIsafe V2

New Modules STEP 7 V5.7 SP1


4 11/2022, A5E50957781-AB
New Modules STEP 7 V5.7 SP1

ET 200S
IM151-8 PN/DP CPU 6ES7 151-8AB01-0AB0 V3.2.18 SNMP configurable (default disabled); Work memory 192KB; 0.06ms/1000 instructions;
PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller;
supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-
Proxy; transport protocol TCP/IP, UDP and ISO on TCP; data record routing;
firmware V3.2.18; expansion with a maximum of 63 modules of the ET200S range
IM151-8F PN/DP CPU 6ES7 151-8FB01-0AB0 V3.2.18 SNMP configurable (default disabled); Work memory 256KB; 0.06ms/1000 instructions;
PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller;
supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-
Proxy; transport protocol TCP/IP, UDP and ISO on TCP; data record routing;
firmware V3.2.18; expansion with a maximum of 63 modules of the ET200S range; can be
used for safety applications; supports PROFIsafe V2

ET 200SP HA
IM155-6 PN HA Red 6DL1 155-6AU00-0PM0 V1.0 Interface module with PROFINET interface V2.3 (RT) with cycle time from 250 micro-
seconds; 56 I/O modules; system redundancy R1; user data up to max. 256 bytes per
I/Omodule; configuration changes during operation; module replacement in operation
(multi-hot swap); start with empty slots; media redundancy (MRP); time-stamp (1ms);
firmware V1.0
IM155-6 PN HA Red 6DL1 155-6AU00-0PM0 V1.1 Interface module with PROFINET interface V2.3 (RT) with cycle time from 250 microse-
conds; 56 I/O modules; system redundancy R1; user data up to max. 256 bytes per I/O
module; configuration changes during operation; module replacement in operation (multi-
hot swap); start with empty slots; media redundancy (MRP); time-stamp (1ms);
firmware V1.1
IM155-6 PN HA Red 6DL1 155-6AU00-0PM0 V1.2 Interface module with PROFINET interface V2.3 (RT) with cycle time from 250 micro-
seconds; 56 I/O modules; system redundancy R1; user data up to max. 256 bytes per
I/O module; configuration changes during operation; module replacement in operation
(multi-hot swap); start with empty slots; media redundancy (MRP); time-stamp (1ms);
firmware V1.2

New Modules STEP 7 V5.7 SP1


11/2022, A5E50957781-AB 5
New Modules STEP 7 V5.7 SP1

ET 200SP HA
IM155-6 PN HA 6DL1 155-6AU00-0PM0 V1.0 Interface module with PROFINET interface V2.3 (RT) with cycle time from 250 micro-
seconds; 56 I/O modules; system redundancy S2; user data up to max. 256 bytes per I/O
module; configuration changes during operation; module replacement in operation (multi-
hot swap); start with empty slots; media redundancy (MRP); time-stamp (1ms);
firmware V1.0
IM155-6 PN HA 6DL1 155-6AU00-0PM0 V1.1 Interface module with PROFINET interface V2.3 (RT) with cycle time from 250 micro-
seconds; 56 I/O modules; system redundancy S2; user data up to max. 256 bytes per I/O
module; configuration changes during operation; module replacement in operation (multi-
hot swap); start with empty slots; media redundancy (MRP); time-stamp (1ms);
firmware V1.1
IM155-6 PN HA 6DL1 155-6AU00-0PM0 V1.2 Interface module with PROFINET interface V2.3 (RT) with cycle time from 250 micro-
seconds; 56 I/O modules; system redundancy S2; user data up to max. 256 bytes per I/O
module; configuration changes during operation; module replacement in operation (multi-
hot swap); start with empty slots; media redundancy (MRP); time-stamp (1ms);
firmware V1.2

New Modules STEP 7 V5.7 SP1


6 11/2022, A5E50957781-AB
New Modules STEP 7 V5.7 SP1

PROFINET IO
Compact Field Unit DIQ 6ES7 655-5PX31-1XX0 V1.2 Interface with PROFINET interface V2.3 (RT) with cycle time as of 250 microseconds;
media redundancy(MRP); singular system redundancy NAP: S2; configuration changes in
runtime; process interface 16x DIQ (freely configurable); firmware V1.2
Compact Field Unit PA 6ES7 655-5PX11-0XX0 V1.0 Interface with PROFINET interface V2.3 (RT) with cycle time as of 250 microseconds;
media redundancy(MRP); singular system redundancy NAP: S2; configuration changes in
runtime; process interface 8x PROFIBUS PA and 8x DI/DO (freely configurable);
firmware V1.0
Compact Field Unit PA 6ES7 655-5PX11-0XX0 V1.1 Interface with PROFINET interface V2.3 (RT) with cycle time as of 250 microseconds;
media redundancy(MRP); singular system redundancy NAP: S2; configuration changes in
runtime; process interface 8x PROFIBUS PA and 8x DI/DO (freely configurable);
firmware V1.1
Compact Field Unit PA 6ES7 655-5PX11-0XX0 V1.2 Interface with PROFINET interface V2.3 (RT) with cycle time as of 250 microseconds;
media redundancy(MRP); singular system redundancy NAP: S2; configuration changes in
runtime; process interface 8x PROFIBUS PA and 8x DIQ (freely configurable);
firmware V1.2
ET 200iSP PN 6ES7 152-1BA00-0AB0 ET 200iSP interface module for intrinsically safe PN, can be used redundantly in fault
tolerant system
ET 200iSP PN R1 6ES7 152-1BA00-0AB0 ET 200iSP interface module for intrinsically safe PN, can be used redundantly in fault
tolerant system; R1 redundancy
IM155-6 PN ST 6ES7 155-6AU01-0BN0 V4.2 Interface module with PROFINET interface V2.3 (RT/IRT) with cycle time from 250 micro-
seconds, PN connection technology can be selected via BusAdapter, 32 I/O modules
including F-modules; media redundancy (MRP); configuration control via PLC; module
replacement in operation; start with empty slots; supports PROFIenergy; Shared Device on
up to 2 PROFINET controllers; supports MSI/MSO; station extension via ET-Connection; user
data up to max. 256 bytes per I/O module; supports module distribution; firmware V4.2

New Modules STEP 7 V5.7 SP1


11/2022, A5E50957781-AB 7
New Modules STEP 7 V5.7 SP1

IO Modules
CM 4xIO-Link 4xM12 6ES7 147-5JD00-0BA0 V1.2 IO-Link master CM 4 x IO-Link, 4 x M12; degree of protection IP65/67; 30 mm overall
width; 4 x port type Class B for connection of IO-Link devices; selectable diagnostics;
supports PROFIenergy; port parameter assignment with Port Configuration Tool (S7-PCT);
firmware V1.2
FC-2 1.1/1.5kW; 2/2 PZD 6SL3 514-1KE13-5AE0 V4.7.14 Frequency converter ET 200pro FC-2 with integrated safety functions; 1.1kW / 1.5kW
(derated); 3AC380V..3AC500V; integrated brake controller
FC-2 1.1/1.5kW; 4/4 PZD 6SL3 514-1KE13-5AE0 V4.7.14 Frequency converter ET 200pro FC-2 with integrated safety functions; 1.1kW / 1.5kW
(derated); 3AC380V..3AC500V; integrated brake controller
AI4 x RTD/TC 2,3,4-wire HF 6ES7 134-6JD00-0CA1 V2.1 Analog input module AI4 x RTD/TC 2,3,4-wire HF 16 bits; value status; common mode
voltage 10 V; channel-specific diagnostics; supports hardware interrupts; scalable
temperature measuring range; firmware V2.1
AI8 x RTD/TC 2-wire HF 6ES7 134-6JF00-0CA1 V2.1 Analog input module AI8 x RTD/TC 2-wire HF 16 bits; value status; common mode voltage
10 V; channel-specific diagnostics; supports hardware interrupts; scalable temperature
measuring range; firmware V2.1
AI 4xI 2-/4-wire HART ISOL HA 6DL1 134-6UD00-0PK0 V1.0 Analog input module AI 4xI 2-/4-wire HART ISOL HA single channel isolated, with HART
communication and HART variables; value status; channel-specific diagnostics;
parameterizable interference frequency suppression; supports hardware interrupts;
supports IO redundancy
AI-DI16/DQ16 x 24VDC HART HA 6DL1 133-6EW00-0PH1 V1.0 Multifunction module AI-DI16/DQ16 x 24VDC HA with HART protocol; 16 inputs
configurable as DI or AI with HART; 16 digital outputs; channel-specific diagnostics;
configurable input delay; configurable substitute value behavior; pulse extension;
configurable interference frequency suppression; supports time stamp; supports IO
redundancy
AI-DI16/DQ16 x 24VDC HART HA 6DL1 133-6EW00-0PH1 V1.1 Multifunction module AI-DI16/DQ16 x 24VDC HA with HART protocol; 16 inputs
configurable as DI or AI with HART; 16 digital outputs; channel-specific diagnostics;
configurable input delay; configurable substitute value behavior; pulse extension;
configurable interference frequency suppression; supports time stamp; supports IO
redundancy

New Modules STEP 7 V5.7 SP1


8 11/2022, A5E50957781-AB
New Modules STEP 7 V5.7 SP1

IO Modules
AI16 x I 2-wire HART HA 6DL1 134-6TH00-0PH1 V1.0 Analog input module AI16 x I 2-wire HA with HART communication and HART variables;
channel-specific diagnostics; configurable interference frequency suppression; supports IO
redundancy
AI16 x I 2-wire HART HA 6DL1 134-6TH00-0PH1 V1.1 Analog input module AI16 x I 2-wire HA with HART communication and HART variables;
channel-specific diagnostics; configurable interference frequency suppression; supports IO
redundancy
AI16 x TC/8xRTD 2-/3-/4-wire HA 6DL1 134-6JH00-0PH1 V1.0 Analog input module AI16 x TC/8xRTD 2-/3-/4-wire HA; channel-specific diagnostics;
configurable interference frequency suppression; supports IO redundancy
AI16 x TC/8xRTD 2-/3-/4-wire HA 6DL1 134-6JH00-0PH1 V1.1 Analog input module AI16 x TC/8xRTD 2-/3-/4-wire HA; channel-specific diagnostics;
configurable input delay; supports IO redundancy; supports REAL display
DI16/DQ16 x 24VDC HA 6DL1 133-6EW00-0PH1 V1.0 Multifunction module DI16/DQ16 x 24VDC HA; 16 digital inputs; 16 digital outputs;
channel-specific diagnostics; configurable input delay; configurable substitute value
behavior; pulse extension; supports time stamp (precision 1ms); supports IO redundancy
DI16/DQ16 x 24VDC HA 6DL1 133-6EW00-0PH1 V1.1 Multifunction module DI16/DQ16 x 24VDC HA; 16 digital inputs; 16 digital outputs;
channel-specific diagnostics; configurable input delay; configurable substitute value
behavior; pulse extension; supports time stamp (precision 1ms); supports IO redundancy
DI16/DQ16 x 24VDC HA 6DL1 133-6EW00-0PH1 V1.1 CNT Multifunction module DI 16/DQ 16xDC24V HA with count function; 16 digital inputs;
16 digital outputs; channel-specific diagnostics; configurable input delay; configurable
substitute value behavior; pulse extension
Ex-AI 2xI 2-wire HART 6DL1 134-6TB00-0HX1 Analog input module Ex-AI 2xI 2-wire HART; with HART communication and HART
variables; value status; channel-specific diagnostics; selectable interference frequency
suppression; supports hardware interrupts; supports MSI
Ex-AI 4xTC/2xRTD 2-/3-/4-wire 6DL1 134-6JD00-0HX1 Analog input module Ex-AI 4xTC/2xRTD 2-/3-/4-wire; value status; channel-specific
diagnostics; selectable interference frequency suppression; supports hardware interrupts;
supports MSI; supports REAL
AQ 4xI HART ISOL HA 6DL1 135-6UD00-0PK0 V1.0 Analog output module AQ 4xI HART ISOL HA single channel isolated, with HART
communication and HART variables; value status; channel-specific diagnostics; with
substitute value output; supports IO redundancy

New Modules STEP 7 V5.7 SP1


11/2022, A5E50957781-AB 9
New Modules STEP 7 V5.7 SP1

IO Modules
AQ8 x I HART HA 6DL1 135-6TF00-0PH1 V1.0 Analog output module AQ8 x I HA with HART protocol; channel-specific diagnostics;
supports IO redundancy
Ex-AQ 2xI HART 6DL1 135-6TB00-0HX1 Analog output module Ex-AQ 2xI with HART communication and HART variables; value
status; channel-specific diagnostics; substitute value for output; supports MSO
DI16 x 24VDC HA 6DL1 131-6BH00-0PH1 V1.0 Digital input module DI16 x 24VDC HA; channel-specific diagnostics; input delay 0..20ms;
pulse extension; supports hardware interrupts; supports IO redundancy; supports time
stamp (precision 1ms)
DI16 x NAMUR HA 6DL1 131-6TH00-0PH1 V1.0 Digital input module DI16 x NAMUR HA; channel-specific diagnostics; configurable pulse
extension; configurable chatter monitoring; supports hardware interrupts; supports time
stamp; IO redundancy
DI32 x 24VDC HA 6DL1 131-6BL00-0PH1 V1.0 Digital input module DI32 x 24VDC HA; channel-specific diagnostics
DI8 x 230VAC HA 6DL1 131-6GF00-0PK0 V1.0 Digital input module DI8 x 230VAC HA
DI8 x 24..125VDC HA 6DL1 131-6DF00-0PK0 V1.0 Digital input module DI8 x 24..125VDC HA; channel-specific diagnostics; supports time
stamp (precision 1ms)
Ex-DI 4xNAMUR 6DL1 131-6TD00-0HX1 Digital input module Ex-DI 4xNAMUR; value status; channel-specific diagnostics; selectable
pulse extension; selectable chatter monitoring; supports hardware interrupts; supports
MSI
Ex-DI 4xNAMUR CNT 6DL1 131-6TD00-0HX1 Digital input module Ex-DI 4xNAMUR; value status; channel-specific diagnostics; selectable
pulse extension; selectable chatter monitoring; supports hardware interrupts; with
counting function; with frequency measurement
DQ16 x 24VDC/0.5A HA 6DL1 132-6BH00-0PH1 V1.0 Digital output module DQ16 x 24VDC/0.5A HA; channel-specific diagnostics; substitute
value for output; supports IO redundancy
DQ32 x 24VDC/0.5A HA 6DL1 132-6BL00-0PH1 V1.0 Digital output module DQ32 x 24VDC/0.5A HA; channel-specific diagnostics
Ex-DQ 2x17.4VDC/27mA 6DL1 132-6CB00-0HX1 Digital output module Ex-DQ 2x17.4VDC/27mA; value status; channel-specific diagnostics;
substitute value for output; supports MSO
Ex-DQ 2x23.1VDC/20mA 6DL1 132-6EB00-0HX1 Digital output module Ex-DQ 2x23.1VDC/20mA; value status; channel-specific diagnostics;
substitute value for output; supports MSO

New Modules STEP 7 V5.7 SP1


10 11/2022, A5E50957781-AB
New Modules STEP 7 V5.7 SP1

IO Modules
RQ4 x 120VDC-230VAC/5A CO HA 6DL1 132-6HD50-0PK0 V1.0 Digital output module RQ4 x 120VDC-230VAC/5A CO HA; substitute value for output;
selectable diagnostics
Ex-PM E 6DL1 133-6PX00-0HW0 Power module Ex-PM E 24V
TM NSIO CNT 6DL1 138-6EA00-0EH1 V1.1 Counting and measuring functions; firmware V1.1
TM NSIO SPEED 6DL1 138-6EA00-0EH1 V1.1 Speed measurement functions; firmware V1.1
TM NSIO 6DL1 138-6EA00-0EH1 V1.1 Input/Output functions 4AI, 4DI, 6 DI/DQ, 4AQ, 4BUF; firmware V1.1
TM NSIO CNT 6DL1 138-6EA00-0EH1 V1.2 Counting and measuring functions; firmware V1.2
TM NSIO SPEED 6DL1 138-6EA00-0EH1 V1.2 Speed measurement functions; firmware V1.2
TM NSIO 6DL1 138-6EA00-0EH1 V1.2 Input/Output functions 4AI, 4DI, 6 DI/DQ, 4AQ, 4BUF; firmware V1.2
TM NSIO DI AI VIB4 6DL1 138-6EC00-0EH1 V1.1 Input/Output functions and vibration protection functions, up to 4 measuring sequences;
firmware V1.1
TM NSIO DI AI VIB8 6DL1 138-6EC00-0EH1 V1.1 Input/Output functions and vibration protection functions, up to 8 measuring sequences;
firmware V1.1
TM NSIO DI VIB4 6DL1 138-6EC00-0EH1 V1.1 Vibration protection functions, up to 4 measuring sequences; firmware V1.1
TM NSIO DI VIB8 6DL1 138-6EC00-0EH1 V1.1 Vibration protection functions, up to 8 measuring sequences; firmware V1.1
TM NSIO DI AI VIB4 6DL1 138-6EC00-0EH1 V1.2 Input/Output functions and vibration protection functions, up to 4 measuring sequences;
firmware V1.2
TM NSIO DI AI VIB8 6DL1 138-6EC00-0EH1 V1.2 Input/Output functions and vibration protection functions, up to 8 measuring sequences;
firmware V1.2
TM NSIO DI VIB4 6DL1 138-6EC00-0EH1 V1.2 Vibration protection functions, up to 4 measuring sequences; firmware V1.2
TM NSIO DI VIB8 6DL1 138-6EC00-0EH1 V1.2 Vibration protection functions, up to 8 measuring sequences; firmware V1.2

New Modules STEP 7 V5.7 SP1


11/2022, A5E50957781-AB 11
New Modules STEP 7 V5.7 SP1

Industrial Ethernet
CP 443-1 6GK7 443-1EX30-0XE0 V3.3 SIMATIC NET CP 443-1, 2 x 10/100 Mbps (IE SWITCH), RJ-45 PORTs, ISO, TCP, UDP,
PROFINET IO Controller, S7 communication, open communications services
(SEND/RECEIVE), S7 routing, IP configuration via DHCP/block, IP access control list, time-of-
day synchronization, advanced Web diagnostics, fast startup, PROFIenergy support
CP 443-1 6GK7 443-1EX30-0XE1 V3.3 SIMATIC NET CP 443-1, 2 x 10/100 Mbps (IE SWITCH), RJ-45 PORTs, ISO, TCP, UDP,
PROFINET IO Controller, S7 communication, open communications services
(SEND/RECEIVE), S7 routing, IP configuration via DHCP/block, IP access control list, time-of-
day synchronization, advanced Web diagnostics, fast startup, PROFIenergy support;
Conformal Coating
CP 443-1 Advanced-IT 6GK7 443-1GX30-0XE0 V3.3 SIMATIC NET CP 443-1 Advanced, 1 x 10/100/1000 Mbps, 4 x 10/100 Mbps (IE SWITCH),
RJ-45 PORTs, in addition to CP 443-1 EX30 V3.2: IP routing, FTP, Web server, e-mail,
security

New Modules STEP 7 V5.7 SP1


12 11/2022, A5E50957781-AB

You might also like