0% found this document useful (0 votes)
36 views

Beam Design

This document contains calculations for the design of reinforced concrete beams including: - Calculation of the effective depth (d) and area of steel reinforcement (Ast) required to resist bending moments up to 230 kN-m - Tables with diameter and area of standard rebar sizes - Calculation of required and provided Ast and rebar spacing for a beam resisting a factored moment of 25,000,000 N-mm - Notes on limiting moments of resistance based on yield strength and concrete compressive strength - Example calculation of minimum depth required for a beam resisting 448,000 kN-m with other given parameters

Uploaded by

rehan7421
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
36 views

Beam Design

This document contains calculations for the design of reinforced concrete beams including: - Calculation of the effective depth (d) and area of steel reinforcement (Ast) required to resist bending moments up to 230 kN-m - Tables with diameter and area of standard rebar sizes - Calculation of required and provided Ast and rebar spacing for a beam resisting a factored moment of 25,000,000 N-mm - Notes on limiting moments of resistance based on yield strength and concrete compressive strength - Example calculation of minimum depth required for a beam resisting 448,000 kN-m with other given parameters

Uploaded by

rehan7421
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 6

COVER 25 mm

REBAR 20 mm
Pt 0.2954
M 100 kN-m
D 600 0.87fy 435
d (eff) 557 Ku 1.208707 1.005*0.87fy*fy/fck 8743.5
b 400 fy 500
fck 25

Ast 6.5816 SQcm 1.4103406


1.253636

4.913043 13.91111 18.93333


0.175466

8.695652

Pt 0.3097
M 230
D 280 0.87fy 435
d 230 Ku 1.242236 1.005*0.87fy*fy/fck 10929.375
fy 500
fck 20

Ast 37.39197 8.0125656


7.122281

4.913043 13.91111
0.175466

8.695652
M 25 25000000 10
j 0.867 12
b 260 16
Sigma st 130

Req Ast 853.1084


Rebar 10 78.5
spacing 125

Prov Ast 628


78.5
113
201
COVER 20 mm
REBAR 12 mm
Pt 0.5951 3.83
M 76.23 kN-m
D 250 0.87fy 435
d (eff) 224 Ku 2.278878 1.005*0.87fy*fy/fck 8743.5
b 1000 fy 500
fck 25

Ast 13.3292 SQcm 2.8562467


2.538886
DIA BAR
4.913043 13.91111 18.93333 8 0.5
0.175466 10 0.785
12 1.13
8.695652 16 2.01
20 3.14
25 4.91
Pt 0.3097 28 6.15
M 230 32 8.04
D 280 0.87fy 435
d 230 Ku 1.242236 1.005*0.87fy*fy/fck 10929
fy 500
fck 20

Ast 37.39197 8.0125656


7.122281
IF THE MOMENT VALUE IS FACTORED , WE NEED TO TAKE OFF 1.5 TIMES FROM Ku formule. If the mometns
unfactored then we need to multiply 1.5 to Ku.
limiting M of resistance = Mu,lit/(bd^2) fy415 fy500
fck15 2.07 2
calc M of resistance fck20 2.76 2.66
2.28 fck25 3.45 3.33
fck30 4.15 3.99
IF CALC M OF RESISTANCE IS MORE THAN LIMITIN M OF RESISTANCE IT SHOULD DESIGN OF DOUBLY R

IF FY500 Mu,lit 0.133fck*bd^2


FOR RAFT IF FY415 Mu,lit 0.138fck*bd^2
SPACING(mm) M 25 25000000
37.51 j 0.867
58.89 b 260
84.78 Sigma st 130
150.80
235.57 Req Ast 853.108386
368.37 Rebar 10 78.5
461.39 spacing 125
603.19
Prov Ast 628
FOR MINIMUM DEPTH REQUIRED
FOR FY500
Fck 35 N/sqmm
Mu 448 kNm 448000000.00 Nmm
b 1000 mm
d 310.23 mm
COV ER 30 REBAR 20
DEPTH (D) 350.23 mm
ormule. If the mometns value is

0.25

D DESIGN OF DOUBLY REINF SECTION.

10 78.5
12 113
16 201