0% found this document useful (0 votes)
349 views4 pages

Fisher 6365-6358-Series-Installation-Guide

This 3 sentence summary provides the essential information from the installation guide document: The document is an installation guide for Type 6365 and 6358 series pressure regulators that provides instructions for installation, startup, and adjustment. It includes specifications for the regulators such as pressure connection type, installation instructions, maximum relief pressures, temperature capability, and pilot set pressure ranges identified by spring color. Users should qualify all personnel installing or servicing the regulators and ensure proper installation according to applicable codes and regulations.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
349 views4 pages

Fisher 6365-6358-Series-Installation-Guide

This 3 sentence summary provides the essential information from the installation guide document: The document is an installation guide for Type 6365 and 6358 series pressure regulators that provides instructions for installation, startup, and adjustment. It includes specifications for the regulators such as pressure connection type, installation instructions, maximum relief pressures, temperature capability, and pilot set pressure ranges identified by spring color. Users should qualify all personnel installing or servicing the regulators and ensure proper installation according to applicable codes and regulations.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Installation Guide

D102692X014 Type 6365 and 6358 Series


English – April 2016

Introduction Pressure Connection


1/4 NPT (internal)
This installation guide provides instructions for
installation, startup and adjustment. To receive a copy
of the instruction manual, contact your local Sales Installation
Office or view a copy at www.fisher.com. For further
information refer to: Type 6365 and 6358 Series
! Warning
Instruction Manual, D102692X012. Only qualified personnel should install
or service a regulator. Regulators
PED Categories should be installed, operated and
This product may be used as a safety accessory with maintained in accordance with
pressure equipment in the following Pressure Equipment international and applicable codes
Directive categories. It may also be used outside of the and regulations and Emerson Process
Pressure Equipment Directive using sound engineering Management Regulator Technologies,
practice (SEP) per table below. For information on the Inc. instructions.
current PED revision see Bulletin: D103053X012. If the regulator vents fluid or a leak
PRODUCT SIZE CATEGORIES FLUID TYPE develops in the system, it indicates that
Type 6365, DN 6 / 1/4 in. service is required. Failure to take the
Type 6358, 1/4 NPT
SEP 1 regulator out of service immediately may
create a hazardous condition.

Specifications Personal injury, equipment damage or


leakage due to escaping fluid or bursting
Pilot Descriptions of pressure-containing parts may result
Type 6365: Set pressure range from 35 mbar to if this regulator is overpressured or
0.14 bar / 14 in. w.c. to 2 psig. This pilot has a high is installed where service conditions
gain restriction standard. could exceed the limits given in the
Type 6358: Set pressure range from 0.21 to 8.6 bar / Specifications section, or where
3 to 125 psig. This pilot has a restriction plug. conditions exceed any ratings of the
Type 6358B: Set pressure range from 0.14 to adjacent piping or piping connections.
8.6 bar / 2 to 125 psig. This pilot is available with a
high, medium or low gain restriction. To avoid such injury or damage, provide
Type 6358EB: Set pressure range of 5.2 to pressure-relieving or pressure-limiting
24.1 bar / 75 to 350 psig. This pilot is available devices (as required by the appropriate
with a high or low gain restriction. code, regulation or standard) to prevent
Type 6358EBH: Set pressure range of 17.2 to service conditions from exceeding limits.
41.4 bar / 250 to 600 psig. This pilot is available Additionally, physical damage to the
with a high or low gain restriction. regulator could result in personal injury
Maximum Relief (Inlet) Pressure (Including Buildup)(1) and property damage due to escaping
Depends upon maximum inlet pressure for fluid. To avoid such injury and damage,
complete relief valve as specified in appropriate install the regulator in a safe location.
main valve bulletin. Clean out all pipelines before installation of the
Pilot Set Pressure Ranges(1)(2) regulator and check to be sure the regulator has not
See Table 1 been damaged or has collected foreign material during
Proof Test Pressure shipping. For NPT bodies, apply pipe compound to the
All Pressure Retaining Components have been external pipe threads. For flanged bodies, use suitable
proof tested per Directive line gaskets and approved piping and bolting practices.
Install the regulator in any position desired, unless
Temperature Capability(1) otherwise specified, but be sure flow through the body
-29 to 66°C / -20 to 150°F is in the direction indicated by the arrow on the body.

1. The pressure/temperature limits in this installation guide or any applicable standard limitation should not be exceeded.
2. Set pressure is defined as the pressure at which the pilot starts to discharge.
Type 6365 and 6358 Series

Table 1. Pilot Set Pressure Ranges and Control Spring Information


SPRING RANGE(1) WIRE DIAMETER FREE LENGTH
PILOT TYPE SPRING COLOR
bar psig mm In. mm In.
6365 35 mbar to 0.14 bar 14 in. w.c. to 2 psig Yellow 1.78 0.070 54.1 2.13
0.21 to 1.24 3 to 18 Green 3.05 0.120 57.2 2.25
6358 0.7 to 2.76 10 to 40 Yellow 3.76 0.148 50.8 2.00
1.4 to 8.62 20 to 125 Red 4.75 0.187 55.6 2.19
0.14 to 0.69 2 to 10 Black 2.59 0.102 53.8 2.12
0.21 to 1.24 3 to 18 Green 3.05 0.120 54.1 2.13
0.69 to 2.07 10 to 30 Silver 3.61 0.142 54.1 2.13
6358B
1.03 to 2.76 15 to 40 Yellow 3.76 0.148 50.8 2.00
2.07 to 4.14 30 to 60 Blue 4.62 0.182 49.3 1.94
0.7 to 8.62 10 to 125 Red 4.75 0.187 55.6 2.19
5.17 to 9.65 75 to 140 Green 5.72 0.225 94.0 3.70
6358EB 8.96 to 13.8 130 to 200 Blue 6.66 0.262 97.8 3.85
12.4 to 24.1 180 to 350 Red 7.47 0.294 107 4.22
17.2 to 31.0 250 to 450 Blue 6.66 0.262 97.8 3.85
6358EBH
27.6 to 41.4 400 to 600 Red 7.47 0.294 107 4.22
1. Main valve may limit advertised spring range. See individual main valve bulletin for additional information.

Overpressure Protection Parts List


The recommended pressure limitations are stamped
on the regulator nameplate. Some type of overpressure 6358 Series Pilots
protection is needed if the actual inlet pressure exceeds the
Key Description
maximum operating outlet pressure rating. Overpressure
protection should also be provided if the regulator inlet 1 Body
pressure is greater than the safe working pressure of the 2 Spring Case
3 Body Plug
downstream equipment.
4 Valve Plug and Stem Assembly
5* Diaphragm Assembly
Regular operation below the maximum pressure
6 Connector Cap
limitations does not preclude the possibility of damage 7 Control Spring
from external sources or debris in the line. The 8 Spring Seat
regulator should be inspected for damage after any 9 Stem Guide
overpressure condition. 10 Adjusting Screw
11 Locknut
12 Closing Cap
Startup 13*
14
Body Plug O-ring
Valve Spring
The regulator is factory set at approximately 15 O-ring, Type 6358EBH (not shown)
the midpoint of the spring range or the pressure 16* Vent Assembly
17 Machine Screw
requested, so an initial adjustment may be required 18 O-ring, Type 6358EB (not shown)
to give the desired results. With proper installation 19* Closing Cap Gasket, Types 6358 and 6358B
completed and relief valves properly adjusted, slowly 20 Restriction Plug, Type 6358
open the upstream and downstream shutoff valves. 20 Restriction, Types 6358B, 6358EB and 6358EBH
21 Filter
29 Gauge
Adjustment 29 Pipe Plug
34 Pipe Nipple
To change the set pressure, remove the closing cap or 36* Connector Cap Gasket
loosen the locknut and turn the adjusting screw clockwise 37* Stem O-ring
38 Lower Spring Seat, Types 6358EB and 6358EBH (not shown)
to increase set pressure or counterclockwise to decrease
40 Diaphragm Limiter, Type 6358EB (not shown)
pressure. Monitor the set pressure with a test gauge 42 NACE Tag
during the adjustment. Replace the closing cap or tighten 43 Tag Wire
the locknut to maintain the desired setting.

Taking Out of Service (Shutdown)


! Warning
To avoid personal injury resulting from
sudden release of pressure, isolate
the regulator from all pressure before *Recommended spare part.

attempting disassembly.
2
Type 6365 and 6358 Series

12 10
12
11 19
10
2 8 11
19
6 2
7
8
5 7
6 36

16 14 36
5
20 9 16
14
4 37 20
9
1 4
37 1
13
3 3 13
A6920 B2619-2

Type 6358 Pilot Interior view Type 6358B Pilot Interior view

Figure 1. Type 6358 and 6358B Pilots

Type 6365 Pilot


12 11 10
Key Description

1 Body Assembly 2 19 8
2 Spring Case
3 Body Plug
4* Plug/Stem Assembly 16 7 6
5* Diaphragm Assembly
6 Connector Cap
7 Control Spring 17 36 14
8 Spring Seat
9 Plug/Stem Guide
10 Adjusting Screw 1 5
11 Locknut
12 Closing Cap
13* Body Plug Gasket 13 9 20
14* Plug/Stem Spring
16 Vent Assembly
17 Machine Screw 3 4
19* Closing Cap Gasket C0542-2

20 Restriction
36* Connector Cap Gasket
Type 6365 Pilot Interior view

Figure 2. Type 6365 Pilot Assembly

*Recommended spare part.

3
Type 6365 and 6358 Series

[email protected] Facebook.com/EmersonAutomationSolutions
Fisher.com LinkedIn.com/company/emerson-automation-solutions
Twitter.com/emr_automation

Emerson Automation Solutions

D102692X014 © 2004, 2018 Emerson Process Management Regulator


Americas Asia Pacific Technologies, Inc. All rights reserved. 09/18.
McKinney, Texas 75070 USA Singapore 128461, Singapore The Emerson logo is a trademark and service mark of Emerson
T +1 800 558 5853 T +65 6777 8211 Electric Co. All other marks are the property of their prospective owners.
+1 972 548 3574 Fisher™ is a mark owned by Fisher Controls International LLC, a
business of Emerson Automation Solutions.
Europe Middle East and Africa
The contents of this publication are presented for information purposes
Bologna 40013, Italy Dubai, United Arab Emirates only, and while effort has been made to ensure their accuracy, they are
T +39 051 419 0611 T +971 4 811 8100 not to be construed as warranties or guarantees, express or implied,
regarding the products or services described herein or their use or
applicability. All sales are governed by our terms and conditions, which
are available on request. We reserve the right to modify or improve the
designs or specifications of our products at any time without notice.
Emerson Process Management Regulator Technologies, Inc does not
For further information on the current
assume responsibility for the selection, use or maintenance of any
PED revision see Bulletin: D103053X012 product. Responsibility for proper selection, use and maintenance of any
or scan the QR code. Emerson Process Management Regulator Technologies, Inc. product
remains solely with the purchaser.