The document discusses the contents, features, and wiring of an industrial gigabit media converter. It contains: 1) A list of contents including the media converter unit, user manual, and SFP dust caps. 2) A description of the converter's LED indicators for power, alarm, and link status. 3) An image and explanation of the converter's upper panel including terminal block connector, DC power inputs, DIP switch, and fault alarm contacts. 4) Guidance on wiring the fault alarm contacts to detect power failures and form an open circuit.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
25 views

EM IGT x205AT - v1.0

The document discusses the contents, features, and wiring of an industrial gigabit media converter. It contains: 1) A list of contents including the media converter unit, user manual, and SFP dust caps. 2) A description of the converter's LED indicators for power, alarm, and link status. 3) An image and explanation of the converter's upper panel including terminal block connector, DC power inputs, DIP switch, and fault alarm contacts. 4) Guidance on wiring the fault alarm contacts to detect power failures and form an open circuit.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

2.2 LED Indicators 2.

5 Wiring the Fault Alarm Contact


1. Package Contents Although 2.5G LED is a bi-color light, the actual color is The fault alarm contacts are in the middle of the terminal block
 System
close to Amber. connector as the picture shows below. When inserting the wires, the
Thank you for purchasing PLANET industrial Gigabit Media Converter, Caution
LED Color Function Industrial Gigabit Media Converter will detect the fault status of the
IGT-1205AT or IGT-2205AT. In the following sections, the term power failure and then forms an open circuit. The following illustration
“Industrial Gigabit Media Converter” mentioned in this user’s P1 Green Lit: Indicates power 1 has power.
shows an application example for wiring the fault alarm contacts.
manual also means the IGT-x205AT. P2 Green Lit: Indicates power 2 has power.
2.3 Converter Upper Panel
Open the box of the Industrial Gigabit Media Converter and carefully 1 2 3 4 5 6
Lit: Indicates one or more of the following events The upper panels of the IGT-x205AT consist of one terminal block
Alarm Red
unpack it. The box should contain the following items: are triggering the alarm (LED). connector within two DC power inputs, and the IGT-x205AT also
provides one DIP switch for fiber redundant function. Figure 2-3 shows
Industrial Gigabit Media
User’s Manual x 1 SFP Dust Cap x 2
 Alarm LED definition the upper panel of the IGT-x205AT.
Converterx 1
Fiber Port FAULT Alarm The Fault Alarm Contacts are
PWR1 PWR2 DIP Alarm LED Max. Fault Alarm Loading: 24V, 1A
DC Input: 12-48V , 0.6A
Link Status OUTPUT AC Input: 24V , 0.6A energized (CLOSE) for normal
1 2 3 4 5 6 Fault Alarm Contacts operation and will OPEN when
NO NO - - - NO Fiber
Mode Alarm failure occurs

YES YES Switch - Off Normal Close


V1+ V2+
Redundant Insert the wires into the fault alarm contacts
YES NO Switch - On Fault Open Switch
PWR1 Alarm PWR2

NO YES Switch - On Fault Open


YES YES Redundant Primary ON Off Normal Close Figure 2-3: IGT-x205AT Upper Panel 1. The wire gauge for the terminal block should be in the
range between 12 and 24 AWG
Primary Slow blink The DIP switch settings and descriptions of the IGT-x205AT
YES YES Redundant Fault Open 2. Alarm relay circuit accepts up to 24V DC, max. 1A
DIN-rail Kit x 1 Wall-mount Kit x 1 RJ45 Dust Cap DOWN for 2 seconds Note
DIP Position Function currents.
Fiber
Primary Mode
YES NO Redundant Blink rapidly Fault Open ON Fiber Redundancy
DOWN
Redundant
Fiber Mode
Primary Switch OFF (default) Switch Mode
NO YES Redundant Blink rapidly Fault Open
DOWN
IGT-1205AT x 1
YES NO Redundant Primary ON On Fault Open 1. If using the Switch mode, the IGT-x205AT can use 3
IGT-2205AT x 2
NO YES Redundant Primary ON On Fault Open or 4 ports.
2. If using the Redundant mode, one of the two Fiber
If any of these are missing or damaged, please contact your dealer Note ports will be redundant while the other 1 or 2 copper
immediately; if possible, retain the carton including the original packing ports are in operation.
material, and use them again to repack the product in case there is a
need to return it to us for repair.

-1- -3- -5- -7-

 Per 10/100/1000T Port 2.4 Wiring the Power Inputs 2.6 Grounding the Device
2. Hardware Introduction The 6-contact terminal block connector on the top panel of Industrial Users MUST complete grounding wired with the device; otherwise, a
LED Color Function
Gigabit Media Converter is used for two DC redundant power inputs. sudden lightning could cause fatal damage to the device.
2.1 Converter Front Panel Lit: Indicates the link through that port Please follow the steps below to insert the power wire.
is successfully established at 10Mbps or
Figures 2-1 and 2-2 show the front panels of the Industrial Gigabit 10/100 1. Insert positive / negative DC power wires into contacts 1 and 2 for
100Mbps. Max. Fault Alarm Loading: 24V, 1A
Media Converters. LNK/ Amber POWER 1, or 5 and 6 for POWER 2.
DC Input: 12-48V , 0.6A
AC Input: 24V , 0.6A
ACT Blinking: Indicates that the Media 1 2 3 4 5 6
Fiber
10/100/1000T Converter is actively sending or receiving Mode
Max. Fault Alarm Loading: 24V, 1A
P1 P2 Alarm P1 P2 Alarm
3
data over that port. DC Input: 12-48V , 0.6A
AC Input: 24V , 0.6A
1 2 3 4 5 6 V1+ V2+
100/1G/2.5G 100/1G/2.5G
10/100
1000
LNK/ACT
LNK/ACT
Lit: Indicates the link through that port Fiber
Mode
Redundant
Switch
PWR1 Alarm PWR2
SFP 1 SFP 1 1000 is successfully established at 1000Mbps.

 SFP Port LNK/ Green Blinking: Indicates that the Media


V1+ V2+
Earth Ground
LNK / LNK /
ACT ACT Redundant
2.5G
1000
2.5G
1000 100/1000/2500BASE-X SFP port ACT Converter is actively sending or receiving PWR1 Alarm PWR2
Switch
100 100

100/1G/2.5G 100/1G/2.5G for transceiver module, enables data over that port.
to have a networking distance of
2. Tighten the wire-clamp screws for preventing the wires from loos-
SFP 2 SFP 2
300 meters to 2km (multi-mode  Per 100/1000/2500X SFP Port EMD (Lightning) DAMAGE IS NOT CONVERED UNDER
ening.
WARRANTY.
LNK /

fiber) and 10/20/40/60/80/120


LNK /
ACT ACT

LED Color Function Note


kilometers (single-mode fiber)
Lit: Indicates the link through that port is
10/100/1000T 10/100/1000T 100 successfully established at 100Mbps.
LNK/ Amber Blinking: Indicates that the Media
ACT
3. Installation
3 3
Converter is actively sending or receiving
10/100 LNK/ACT 10/100 LNK/ACT  Gigabit TP Interface data over that port.
1000 LNK/ACT
10/100/1000BASE-T copper RJ45
1000 LNK/ACT
100/1G/2.5G

Lit: Indicates the link through that port is This section describes the functionalities of the Industrial Gigabit Media
twisted-pair with up to 100 meters 1 2 3 4 5 6
SFP 1

1000 successfully established at 1000Mbps. Converter’s components and guides how to install it on the DIN-rail
4 in distance. LNK /
Power 1 Alarm Power 2
and wall. Basic knowledge of networking is assumed. Please read this
ACT

2.5G
1000
100
LNK/ Green Blinking: Indicates that the Media + - + -
100/1G/2.5G
ACT chapter completely before continuing.
IGT-1205AT IGT-2205AT Converter is actively sending or receiving
data over that port.
SFP 2

LNK /
ACT
1. The wire gauge for the terminal block should be in the
Figure 2-1: Figure 2-2: Lit: Indicates the link through that port is range between 12 and 24 AWG. This following pictures show the user how to install the
IGT-1205AT IGT-2205AT 2500 Amber successfully established at 2500Mbps. device, and the device is not IGT-x205AT.
2. The DC power input range is 12V ~ 48V DC and Note
Front Panel Front Panel LNK/ + supports 24V AC.
Blinking: Indicates that the Media Note
ACT Green Converter is actively sending or receiving
3. Use one power input when using 24V AC.
data over that port.

-2- -4- -6- -8-


3.1 DIN-rail Mounting Installation PLANET Industrial Gigabit Media Converter supports 100/1000/2500X
with both single mode and multi-mode SFP transceivers. Before we
connect Industrial Gigabit Media Converter to the other network device,
please do the following:
1
1. Set the DIP Switch of SFP Port 1 or Port 2 to the “OFF” position
with fiber speed auto detection.
2
DIP Position Function
ON Fiber Redundancy
Fiber Mode
OFF (default) Switch Mode

3.2 Wall-mount Plate Mounting 2. Make sure both sides of the SFP transceivers are with the same
media type, for example, 1000BASE-SX to 1000BASE-SX, and
1000BASE-LX to 1000BASE-LX.

Never pull out the module without pulling the lever or


the push bolts on the module. Directly pulling out the
module with force could damage the module and the
Note SFP port of the Industrial Gigabit Media Converter.

3.3 Side Wall-mount Plate Mounting

You must use the screws supplied with the wall-


mounting brackets. Damage caused to the parts by
Caution using incorrect screws would invalidate your warranty.

-9- - 11 -

3.3 Installing the SFP Transceiver


The sections describe how to insert an SFP transceiver into an SFP
4. Product Specifications ESD Protection 6KV DC
5. Customer Support
Converter Specifications
port.
Model IGT-1205AT IGT-2205AT Processing Thank you for purchasing PLANET products. You can browse our online
The SFP transceivers are hot-pluggable and hot-swappable. You can Store-and-Forward
Scheme FAQ resource on PLANET web site first to check if it could solve your
plug in and out the transceiver to/from any SFP port without having Hardware Specifications
issue. If you need more support information, please contact PLANET
to power down the Industrial Gigabit Media Converter as Figure 3-1 Fabric 12Gbps 14Gbps
1 x 10/100/1000BASE-T 2 x 10/100/1000BASE-T switch support team.
shows. Copper Interface
RJ45 RJ45 Throughput
PLANET online FAQs:
(packet per 8.93Mpps@64bytes 10.42Mpps@64bytes
2 x 100/1G/2.5GBASE-X SFP interfaces http://www.planet.com.tw/en/support/faq
Fiber Optic second)
(Port-1 and Port-2)
Interfaces Switch support team mail address:
Supports auto detection Back pressure for half duplex.
Flow Control [email protected]
MGB / MFB IEEE 802.3x pause frame for full duplex
Series Module Removable 6-pin terminal block
Pin 1/2 for Power 1; Address Table 4K entries
Connector
Pin 3/4 for fault alarm;
Jumbo Frame 9216bytes
Pin 5/6 for Power 2
Standards Conformance
Figure 3-1: Inserting the SFP Transceiver DIP Position Function
IEEE 802.3 Ethernet
DIP Switch Fiber ON Fiber Redundancy
IEEE 802.3u Fast Ethernet
Mode OFF (default) Switch Mode Standards IEEE 802.3ab Gigabit Ethernet
It is recommended to use PLANET SFP transceiver on
the Industrial Gigabit Media Converter. If you insert an Compliance IEEE 802.3z Gigabit Ethernet 1000BASE-SX/LX
Provides one relay output for power failure IEEE 802.3x Full-Duplex Flow Control
SFP transceiver that is not supported, the Industrial Alarm
Note Alarm Relay current carry ability: 1A @ DC 24V IEEE 802.1p Class of Service
Gigabit Media Converter will not recognize it.
Power DC 12~48V or AC 24V
Regulatory
Requirements Redundant power with reverse polarity protection FCC Part 15 Class A, CE
Compliance
Power
IEC60068-2-32 (free fall)
Consumption / 4.8 watts/16BTU 4.92 watts/16.9BTU
Stability Testing IEC60068-2-27 (shock)
Dissipation
IEC60068-2-6 (vibration)
Dimensions
32 x 87 x 135mm 32 x 87 x 135mm Environment
(W x D x H)
Operating: -40~75 degrees C
Weight 412g 419g Temperature Copyright © PLANET Technology Corp. 2022.
Storage: -40~75 degrees C
Enclosure IP30 type metal case Contents are subject to revision without prior notice.
Operating: 5~95% (non-condensing) PLANET is a registered trademark of PLANET Technology Corp.
Installation DIN-rail kit and wall mount ear Humidity
Storage: 5~95% (non-condensing) All other trademarks belong to their respective owners.