EM IGT x205AT - v1.0
EM IGT x205AT - v1.0
Per 10/100/1000T Port 2.4 Wiring the Power Inputs 2.6 Grounding the Device
2. Hardware Introduction The 6-contact terminal block connector on the top panel of Industrial Users MUST complete grounding wired with the device; otherwise, a
LED Color Function
Gigabit Media Converter is used for two DC redundant power inputs. sudden lightning could cause fatal damage to the device.
2.1 Converter Front Panel Lit: Indicates the link through that port Please follow the steps below to insert the power wire.
is successfully established at 10Mbps or
Figures 2-1 and 2-2 show the front panels of the Industrial Gigabit 10/100 1. Insert positive / negative DC power wires into contacts 1 and 2 for
100Mbps. Max. Fault Alarm Loading: 24V, 1A
Media Converters. LNK/ Amber POWER 1, or 5 and 6 for POWER 2.
DC Input: 12-48V , 0.6A
AC Input: 24V , 0.6A
ACT Blinking: Indicates that the Media 1 2 3 4 5 6
Fiber
10/100/1000T Converter is actively sending or receiving Mode
Max. Fault Alarm Loading: 24V, 1A
P1 P2 Alarm P1 P2 Alarm
3
data over that port. DC Input: 12-48V , 0.6A
AC Input: 24V , 0.6A
1 2 3 4 5 6 V1+ V2+
100/1G/2.5G 100/1G/2.5G
10/100
1000
LNK/ACT
LNK/ACT
Lit: Indicates the link through that port Fiber
Mode
Redundant
Switch
PWR1 Alarm PWR2
SFP 1 SFP 1 1000 is successfully established at 1000Mbps.
100/1G/2.5G 100/1G/2.5G for transceiver module, enables data over that port.
to have a networking distance of
2. Tighten the wire-clamp screws for preventing the wires from loos-
SFP 2 SFP 2
300 meters to 2km (multi-mode Per 100/1000/2500X SFP Port EMD (Lightning) DAMAGE IS NOT CONVERED UNDER
ening.
WARRANTY.
LNK /
Lit: Indicates the link through that port is This section describes the functionalities of the Industrial Gigabit Media
twisted-pair with up to 100 meters 1 2 3 4 5 6
SFP 1
1000 successfully established at 1000Mbps. Converter’s components and guides how to install it on the DIN-rail
4 in distance. LNK /
Power 1 Alarm Power 2
and wall. Basic knowledge of networking is assumed. Please read this
ACT
2.5G
1000
100
LNK/ Green Blinking: Indicates that the Media + - + -
100/1G/2.5G
ACT chapter completely before continuing.
IGT-1205AT IGT-2205AT Converter is actively sending or receiving
data over that port.
SFP 2
LNK /
ACT
1. The wire gauge for the terminal block should be in the
Figure 2-1: Figure 2-2: Lit: Indicates the link through that port is range between 12 and 24 AWG. This following pictures show the user how to install the
IGT-1205AT IGT-2205AT 2500 Amber successfully established at 2500Mbps. device, and the device is not IGT-x205AT.
2. The DC power input range is 12V ~ 48V DC and Note
Front Panel Front Panel LNK/ + supports 24V AC.
Blinking: Indicates that the Media Note
ACT Green Converter is actively sending or receiving
3. Use one power input when using 24V AC.
data over that port.
3.2 Wall-mount Plate Mounting 2. Make sure both sides of the SFP transceivers are with the same
media type, for example, 1000BASE-SX to 1000BASE-SX, and
1000BASE-LX to 1000BASE-LX.
-9- - 11 -
- 10 - - 12 - - 13 - - 14 -