1) GENERAL FEATURES
1.1) Introduction
Due to the characteristic of low maintenance modules (designed for topping up only
during regular maintenance of the vehicle), their electrochemical behaviour does not
allow the detection of a voltage threshold at the end of the first phase of charging at
constant current or power, especially for temperatures above 30°C.
In addition, although more pronounced than for flooded STM modules, the
temperature variation at end of the first phase of charging at constant current or
power is not high enough to optimise charge management.
Initialisation charge
This is carried out during battery commissioning by the garage technician using an
external command non accessible to the users.
Normal charge
Equalisation charge
This is used to balance the battery to reduce capacity and voltage dispersion.
This charge offers a higher recharge coefficient than a normal charge. It is carried
out periodically and automatically according to vehicle specific criteria.
Maintenance charge
This is carried out during maintenance operations. The battery is fully charged and
the electrolyte is topped up. It is carried out by the garage technician using an
external command non accessible to the users.
Fast charge
This is carried out at a fast charge station, allowing a completely discharged battery
to be 75% charged in 30 minutes. This is not a full charging operation.
DTT/BX/EV/MB/98-640 1/10
S A F T
ADVANCED AND INDUSTRIAL BATTERIES
2) a charged and discharged amperehour meter which takes into account the
battery self discharge (pilot meter) and simulates voltage threshold detection
to allow charge management at any temperature.
• When the battery is inactive, the pilot meter increments the self discharge
capacity (calculated from a parametric model).
• During discharge, the pilot meter increments the measured discharged capacity.
• During charge, the pilot meter decrements the measured capacity charged. The
meter does not count down below zero.
• The meter is set to zero at the end of a constant current or power charge when
one of the end of charge criteria (voltage threshold or pilot meter value) is
reached.
DTT/BX/EV/MB/98-640 2/10
S A F T
ADVANCED AND INDUSTRIAL BATTERIES
The charge must only be used for the cases given in the following graphs.
Temperature
T2
Charge unadvisable
T1
Charge authorized
State of charge
EC1 100 %
The charge must only be utilised in the cases given in the following graph:
Temperature
T4
Charge unadvisable
T3
Charge authorized
TB
Charge unadvisable
State of charge
EC2 75 %
If the temperature exceeds these limits during charging, the charge must be
interrupted and restarted only when the temperature has dropped to the authorised
fast charge temperature.
DTT/BX/EV/MB/98-640 3/10
S A F T
ADVANCED AND INDUSTRIAL BATTERIES
2.4.1) Precharge
For a fully discharged battery that has been stored for some time, the beginning of
the charge causes a voltage increase that may exceed the voltage switch threshold
of the constant current or power phase to the overcharge phase and hence stop the
charge prematurely without restoring the full capacity of the battery . The precharge
is automatically triggered at a low current and limited time before charging to avoid
this problem.
If the voltage remains lower than UP after precharge a battery defect indication must
be displayed.
This charge is carried out to initialize the pilot meter and the battery when the vehicle
is commissioned. After this charge, the pilot meter must be reset to zero and the
electrolyte in the battery should be topped up.
DTT/BX/EV/MB/98-640 4/10
S A F T
ADVANCED AND INDUSTRIAL BATTERIES
or
Safety
If this criterion is met, the charge is stopped, the pilot meter is reset to zero and the
maintenance meter increments by one set overcharged capacity (VS1)
In this case, a «defective system» indication must be displayed.
DTT/BX/EV/MB/98-640 5/10
S A F T
ADVANCED AND INDUSTRIAL BATTERIES
Safety:
If the maximum time (t2) is reached, the charge is stopped. In this case, a « defective
system » indication must be displayed.
This is an I1 constant current phase with a set DE duration irrespective of the Phase I
or P charged capacity.
or
Safety
If maximum charge time (t1) is reached, the charge is stopped, the pilot meter is
reset to zero and the maintenance meter increments by one set overcharged
capacity (VS1)
In this case, a « defective system » indication must be displayed.
DTT/BX/EV/MB/98-640 6/10
S A F T
ADVANCED AND INDUSTRIAL BATTERIES
This is an I2 constant current phase with a set DEN duration irrespective of the
Phase I or P charged capacity.
• using a threshold voltage Ucr corrected according to the temperature and value
of the intensity of the charge (ICR)
where T is the actual module temperature and I is the selected fast charge
current
or
Safety
If this criterion is met, the charge is stopped. In this case, a « defective system »
indication must be displayed.
DTT/BX/EV/MB/98-640 7/10
S A F T
ADVANCED AND INDUSTRIAL BATTERIES
If the vehicle is inactive for a long period (more than one month), self-discharge will
cause a battery modelling mismatch. It will then be difficult to handle vehicle
charging.
Because of this, the first recharge after the period of inactivity must be an
equalisation charge to correct any mismatch between the pilot meter and the real
state of charge of the battery.
In this case, information about pilot meter values becomes erroneous. An initialisation
charge must be carried out to re-commission the battery and at the end of charge the
pilot meter must be reset to zero.
DTT/BX/EV/MB/98-640 8/10
S A F T
ADVANCED AND INDUSTRIAL BATTERIES
PRECHARGE
INITIALISATION CHARGE
DTT/BX/EV/MB/98-640 9/10
S A F T
ADVANCED AND INDUSTRIAL BATTERIES
NORMAL CHARGE
Overcharge current I1 A 5
Normal charge overcharge coefficient K1 % 15
Safety
Max duration of constant current charge I1 t2 h 8
EQUALISATION CHARGE
Overcharge current I1 A 5
Duration of constant current I1 charge DE h 5
MAINTENANCE CHARGE
Overcharge current I2 A 10
Duration of constant current I2 charge DEN h 5
Electrolyte topping up phase
Duration of peaks at I2 DM min 2
Rest between peaks at I2 DR min 30
FAST CHARGE
* measured capacity
DTT/BX/EV/MB/98-640 10/10