The NetEngine 8000 M4 is a compact, cost-effective mini BNG router that packs up to 1.6 Tbps of port capacity into a 2U high chassis. It supports a variety of port speeds and technologies including 100GE, 50GE, 40GE, 25GE, 10GE and GE. The router can be used to build various network types and supports technologies such as SRv6, EVPN, and FlexE. It provides reliable service quality while integrating multiple functions and simplifying network structures.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
967 views

NetEngine 8000 M4 Universal Service Router Datasheet

The NetEngine 8000 M4 is a compact, cost-effective mini BNG router that packs up to 1.6 Tbps of port capacity into a 2U high chassis. It supports a variety of port speeds and technologies including 100GE, 50GE, 40GE, 25GE, 10GE and GE. The router can be used to build various network types and supports technologies such as SRv6, EVPN, and FlexE. It provides reliable service quality while integrating multiple functions and simplifying network structures.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 18

Datasheet

NetEngine 8000 M4 Service Router


Datasheet

Overview
The NetEngine 8000 M4 is the most cost-effective mini BNG router. Though only 2U high and 220 mm deep, it packs
up to 1.6 Tbps of port capacity and four service slots. It provides 100GE, 50GE, 40GE, 25GE, 10GE, and GE ports to
flexibly adapt to different service scenarios and supports features such as SRv6, EVPN, FlexE, and 1588v2. Its
compact design saves space resources, significantly lowering CAPEX.

The product fully supports the future-oriented next-generation unified network SRv6 technology and can be used to
build IP backbone, metro, mobile backhaul, and data center networks. It can be used for individual/enterprise cloud
migration, inter-cloud interconnection, IoT, government and enterprise private lines, home broadband applications,
and CDN. As a basic bearer protocol of the entire network, SRv6 implements end-to-end full-service bearer
capabilities. SRv6 enables simplified protocols, large-scale networking, seamless integration, high reliability,
integrated service chains, network and service programmability, and a full ecosystem.

⚫ Support for the Deterministic IP (DIP) technology. The periodic scheduling mechanism prevents cross-period
packet collisions and ensures deterministic delay when nodes are processing data.

⚫ Support for data redundancy elimination (DRE) to compress and decompress data between WAN border
routers, reducing bandwidth consumption of WAN links, reducing line costs, and accelerating the
deployment of distributed data centers.

The NetEngine 8000 series router integrates multiple functions, simplifies the network structure, provides rich service
types, reliable service quality, and intelligent O&M. It leads the IP WAN to an intelligent network with self-driving
driving, and continuously drives the business success of enterprise customers.

NetEngine 8000 M4 service router (DC) NetEngine 8000 M4 service router (AC)

1
Application Scenario

Product Specifications
Physical Specifications
NetEngine 8000 M4 AC
Item Description

Cabinet installation standards ETSI (21-inch); IEC (19-inch)

Dimensions without packaging (H x W x D)


88.9 mm x 442 mm x 220 mm (3.5 in. x 17.4 in. x 8.66 in.)
[mm(in.)]

Chassis height [U] 2U

Weight without packaging [kg(lb)] 9.2 kg (20.24 lb)

Weight with packaging [kg(lb)] 11.9 kg (26.24 lb)

Weight without packaging (full


10.8 kg
configuration) [kg(lb)]

Weight with packaging (full configuration)


13.5 kg
[kg(lb)]

Typical power consumption (with


305.1 W
configuration) [W]

Typical heat dissipation (with configuration)


989.87 BTU/hour
[BTU/hour]

MTBF [year] 31.62 year

MTTR [hour] 0.5 hour

Availability 0.999998195

SDRAM 16GB

Flash memory 64MB

Storage 16 GB

2
Item Description

Power supply mode AC

Rated input voltage [V] 200 V–240 V/100 V–127 V dual-live wire, supporting 240 V HVDC

Input voltage range [V] 90 V to 290 V

Maximum input current [A] 10 A

Rated output power [W] 1500 W

Maximum input cable size [mm²] Standard C13 cable

Front-end circuit breaker/fuse [A] ≥10 A

Heat dissipation mode Air cooling

Airflow direction From left to right

Noise at normal temperature (acoustic


< 65 dB(A)
power) [dB(A)]

Number of slots 8

Number of service board slots 2

Switching capacity 2.4 Tbit/s (Bidirectional)

Redundant power supply 1+1

1+1. Short-term running when a single fan becomes invalid at the


Redundant fans ambient temperature of 40°C (104°F) (one fan module contains two
fans)

Long-term operating temperature [°C(°F)] –20°C to + 55°C (–4ºF to +131ºF)

Restriction on the operating temperature


≤ 30°C/hour (54°F/hour)
variation rate [°C(°F)]

Storage temperature [°C(°F)] –40°C to +70°C (–40°F to +158°F)

Long-term operating relative humidity [RH] 5% to 85% RH, non-condensing

Short-term operating relative humidity [RH] 5% to 95% RH, non-condensing

Storage relative humidity [RH] 5% to 95% RH, non-condensing

≤ 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to


4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the
Long-term operating altitude [m(ft.)]
device decreases by 1°C [33.8°F] each time the altitude increases
by 220 m [721.78 ft.].)

3
Item Description

Storage altitude [m(ft.)] < 5000 m (< 16404.2 ft.)

NetEngine 8000 M4 DC
Item Description

abinet installation standards ETSI (21-inch); IEC (19-inch)

Dimensions without packaging (H x W x D)


88.9 mm x 442 mm x 220 mm (3.5 in. x 17.4 in. x 8.66 in.)
[mm(in.)]

Chassis height [U] 2U

Weight without packaging [kg(lb)] 7.2 kg (15.87 lb)

Weight with packaging [kg(lb)] 9.9 kg (21.78 lb)

Weight without packaging (full


10.4 kg
configuration) [kg(lb)]

Weight with packaging (full configuration)


13.1 kg
[kg(lb)]

Typical power consumption (with


283.4 W
configuration) [W]

Typical heat dissipation (with configuration)


919.47 BTU/hour
[BTU/hour]

MTBF [year] 33.40 year

MTTR [hour] 0.5 hour

Availability 0.999998291

SDRAM 16GB

Flash memory 64MB

Storage 16 GB

Power supply mode DC

Rated input voltage [V] –48 V/–60 V

Input voltage range [V] –40 V to –72 V

Maximum input current [A] 30 A

4
Item Description

Rated output power [W] 1200 W

Maximum input cable size [mm²] 4 mm^2 (0–14 m)

≥ 16 A (Based on long-term evolution requirements and site


Front-end circuit breaker/fuse [A] conditions, the recommended current is greater than or equal to 32
A.)

Heat dissipation mode Air cooling

Airflow direction From left to right

Noise at normal temperature (acoustic


< 65 dB(A)
power) [dB(A)]

Number of slots 8

Number of service board slots 6

Switching capacity 2.4 Tbit/s (Bidirectional)

Redundant power supply 1+1

1+1. Short-term running when a single fan becomes invalid at the


Redundant fans ambient temperature of 40°C (104°F) (one fan module contains two
fans)

Long-term operating temperature [°C(°F)] -20°C to 60°C(-4.0°F to 140.0°F)

Restriction on the operating temperature


≤ 30°C/hour (54°F/hour)
variation rate [°C(°F)]

Storage temperature [°C(°F)] –40°C to +70°C (–40°F to +158°F)

Long-term operating relative humidity [RH] 5% to 85% RH, non-condensing

Short-term operating relative humidity [RH] 5% to 95% RH, non-condensing

Storage relative humidity [RH] 5% to 95% RH, non-condensing

≤ 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to


4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the
Long-term operating altitude [m(ft.)]
device decreases by 1°C [33.8°F] each time the altitude increases
by 220 m [721.78 ft.].)

Storage altitude [m(ft.)] < 5000 m (< 16404.2 ft.)

Regulatory Compliance
Item Description

5
Item Description

egulatory compliance EMC


⚫ ANSI C63.4
⚫ AS/NZS CISPR 32
⚫ CISPR 24
⚫ CISPR 32
⚫ EN 55024
⚫ EN 55032
⚫ ETSI EN 300 386
⚫ ETSI ES 201 468
⚫ FCC CFR47 Part 15 Subpart B
⚫ ICES-003 Issue 6
⚫ ICES-GEN Issue 1
⚫ IEC 61000-3-2
⚫ IEC 61000-3-3
⚫ IEC 61000-4-11
⚫ IEC 61000-4-2
⚫ IEC 61000-4-29
⚫ IEC 61000-4-3
⚫ IEC 61000-4-4
⚫ IEC 61000-4-5
⚫ IEC 61000-4-6
⚫ IEC 61000-6-2
⚫ IEC 61000-6-4
⚫ VCCI-CISPR 32
Environment

⚫ IEC 60068-2-30

⚫ IEC 60068-2-78

⚫ IEC 60068-2-14

⚫ IEC 60068-2-1

⚫ IEC 60068-2-2

Safety

⚫ IEC/EN/UL/CSA 60950-1

⚫ IEC/EN 62368-1

Environmental protection

⚫ 2011/65/EU & (EU)2015/863 (EU RoHS)

⚫ Regulation (EC) No.1907/2006 (REACH)

⚫ 2012/19/EU (WEEE)

⚫ 2006/66/EC & 2013/56/EU on batteries and accumulators

6
Function Specifications

Specifications Description

Number of service cards DC: 4 (slots 1 to 4); AC: 2 (slots 2 and 4)

Layer 2 functions IEEE 802.1Q, IEEE 802.1p, IEEE 802.3ad, IEEE 802.1ab,
STP/RSTP/MSTP

Layer 3 functions OSPF, RIP, IS-IS, BGP, ACL, IPv4, 6VPE, ARP, VLANIF,
VXLAN, EVPN

MPLS LDP, RSVP-TE, L2VPN, L3VPN, seamless MPLS

⚫ IS-IS for SRv6, OSPFv3 for SRv6, SRv6 TE Policy, SRv6


TE Policy Shortcut, SRv6 Flex-Algo, SRv6 SRH
Compression, SRv6 Network Slicing

⚫ BGP for SRv6, SRv6 BE, SBFD for SRv6 BE, SRv6 TI-
SR/EVPN
LFA FRR, SRv6 middle-node protection, SRv6 micro-loop
avoidance, SRv6 OAM, SRv6 SFC, G-SRv6

⚫ EVPN E-LAN/E-Line/E-Tree, EVPN L3VPN, EVPN


VXLAN, PBB EVPN

Multicast IGMP, static multicast routing, PIM-SM/SSM, MBGP, BIERv6

MACSec Supported by ports 0 to 31

Value added services Per-device (onboard):

NAT sessions: 2M/slot, NAT throughput 4.8 Gbps

IPsec tunnels: 10,000/device, throughput 3.4 Gbps

Per-slot (VSUP slot):

NAT sessions: 32M/slot, 50Gbps@512B

IPsec tunnels: 20,000/device, throughput 40G@512B

SA, data redundancy elimination (up to 6 Gbit/s)

Note: Data in the preceding table is provided on specific test


conditions. Actual data is subject to configurations on devices.

QoS 5-level HQoS

Clock (supported only by fixed


1588v2, 1588 ATR, 1588 ACR, synchronous Ethernet,
ports) G.8275.1

OAM Telemetry, IFIT, IPFPM, Ethernet OAM, BFD, NQA, RFC 2544,
Y.1564, TWAMP

7
Combo Modes of Ports
 Flexible combo mode switching: four groups of combo ports, six modes for switching.
 Type 1 is the default combo mode. When the device is running, you can run a command to switch the combo
mode of a combo group. In this case, the traffic of the combo group is temporarily interrupted.
 The combo mode switching of one combo group, however, does not affect other combo groups.

Combo groups can flexibly switch their combo modes


Combo Mode Description 4 Ports per Group

Type 1 (default) 100GE (50GE/40GE auto 4*GE


sensing)

Type 2 4*25GE breakout supported 4*GE

Type 3 50GE 4*10GE/GE (the four ports in each group switch their
combo modes together)

Type 4 40GE 4*10GE/GE (the four ports in each group switch their
combo modes together)

Type 5 4*10GE breakout supported 4*10GE/GE (the four ports in each group switch their
combo modes together)

Type 6 NULL 4*25GE/10GE (the four ports in each group switch


their combo modes together)

8
Maximum Number of ports in combo
Combo Mode (100GE/50GE/40GE) 25GE/10GE

Type 1 (default) 4*(100GE/50GE/40GE+4*GE) 16*10GE/GE(default)

Type 2 4*(4*25GE(breakout)+4*GE) 16*25GE/10GE

Type 3 4*(50GE+4*10GE/GE) 16*25GE/10GE

Type 4 4*(40GE+4*10GE/GE) 16*25GE/10GE

Type 5 4*(40GE+4*10GE/GE) 16*25GE/10GE

Type 6 4*(4*25GE/10GE) 16*25GE/10GE

Maximum Number of ports


Combo Mode 100GE

100GE 8

50GE 8

25GE 32

10GE 40

GE 40 (80 if 20GE CSFP modules are used)

Ordering Information
Basic Hardware Configurations
NetEngine 8000 M4 Basic Configurations

Order Name Description Remarks

NetEngine 8000 M4 Basic Configuration CM (Includes M4


Chassis, Enable Fixed Interface(2*100GE/8*25GE
CR8PM4BASDC0 V800R022C00
combo+16*10GE, #4~#19 default enable GE), DC Power, Fan
Box,without Software Charge and Document)

NetEngine 8000 M4 Basic Configuration CM (Includes M4


Chassis, Enable Fixed Interface(2*100GE/8*25GE
CR8PM4BASAC0 V800R022C00
combo+16*10GE, #4~#19 default enable GE), AC Power, Fan
Box,without Software Charge and Document)

CR8M004FBXC0 NetEngine 8000 M4 Fan Box

ETP4860-2KW-FE AC Power Box

DP22PDC1K2A1 Power Interface Board

PAC1K5S53-AL 1500W AC Power Module

DP52APIUCA00 AC Power Interface Unit Converting Board

9
Interface Cards

Order Name Description Remarks

NetEngine 8000 M Series 100G upgrade to 200G Port Enable


CR8SA0EXE0C0
RTU

NetEngine 8000 M Series 100G upgrade to 400G Port Enable


CR8SA0EXK0C0
RTU

NetEngine 8000 M Series 200G upgrade to 400G Port Enable


CR8SE0EXK0C0
RTU

1-Port 100GE/ 1-Port 200GE CFP2 Physical Interface V800R022C00


CR8D00E1NCC1
Card(PIC) (Enable 1*100GE by default) Normally supplied

2-Port 100GBase/50GBase-QSFP28 FlexE MACsec Physical V800R022C00


CR8D00E2NBC4
Interface Card(PIC) Normally supplied

2-Port 50GBase/1-Port 100GBase-QSFP28 FlexE MACsec V800R022C00


CR8D00E1NBC2
Physical Interface Card(PIC) Normally supplied

4-Port 25GE(SFP28)/10GE(SFP+) MACsec Physical Interface V800R022C00


CR8D00E4YFC0
Card (PIC) Normally supplied

10-Port 10GE/GE LAN/WAN-SFP+ MACsec Physical Interface V800R022C00


CR8D00EAXFC1
Card(PIC) Normally supplied

20-Port 100/1000Base-X-CSFP/10-Port 100/1000Base-X-SFP


CR5D00EEGF73 V800R022C10
Physical Interface Card(PIC)

20-Port 100/1000Base-X-CSFP/10-Port 100/1000Base-X-SFP


CR8D00EEGFXA V800R022C10
Physical Interface Card(PIC)

10-port 100/1000Base-X-SFP MACsec Physical Interface V800R022C00


CR8D00EAGFCA
Card(PIC) Normally supplied

V800R022C00
CR8D00E8GEB2 8-Port 100/1000Base-RJ45 Physical Interface Card(PIC)
Normally supplied

CR8D000DE1C2 16-Port E1 Physical Interface Card(PIC,75ohm/120ohm) V800R023C00, not GA

4-Port Channelized STM-1c POS-SFP Physical Interface


CR5D00C4CFC1 V800R023C00, not GA
Card(PIC)

8-Port STM-1c/8-Port STM-4c POS Card (PIC)(Default Enable


CR8D00P8CFC1 V800R022C10
4*STM-1c)

10
Service Cards
Order Name Description Remarks

CGN
NetEngine 8000 M Series Integrated Service Card CGN Service
CR8D0CGNA0C1 Basic Configuration (Including 1 VSUP-100+20Gbps Capacity V800R022C00
for CGN)
Normally supplied

NetEngine 8000 M Series Integrated Service Card CGN Service


CR8SCGN10GC0 CGN
10Gbps Capacity RTU

N1-N8KM4NATS- N1-NetEngine 8000 M4 Series Integrated Service Card CGN


CGN
LIC Service 1M NAT Session License

Includes DS-Lite, PCP,


N1-N8KM4NATDP- N1-NetEngine 8000 M4 Series Integrated Service Card CGN
and NAT64 (V8R22C10
LIC Enhanced Function License
or later)

N1-N8KM4NATS- N1-NetEngine 8000 M4 Integrated Service Card CGN Service


CGN
SNS 1M NAT Session License SnS

N1-N8KM4NATDP- N1-NetEngine 8000 M4 Integrated Service Card CGN Service


CGN
SNS Enhanced Function License SnS

NetEngine 8000 M Series Integrated Service Card IPsec Service IPsec, V800R022C00
CR8DVSUIPSC0 Basic Configuration (Including 1 VSUP-100+20Gbps Capacity
for IPsec) Normally supplied

NetEngine 8000 M Series Integrated Service Card IPsec Service


CR8SIPS10GC0 IPsec
10Gbps Capacity RTU

N1-N8KM4IPsec- N1-NetEngine 8000 M4 Series IPsec Tunnel Quantity


IPsec
LIC License(500 Tunnels)

N1-N8KM4IPsec- N1-NetEngine 8000 M4 IPsec Tunnel Quantity License(500


IPsec
SNS Tunnels) SnS

NetEngine 8000 M Series Integrated Service Card SA Service


Service awareness,
CR8PMDVSUPM0 Basic Configuration (Including 1 VSUP-100+4Gbps Capacity for
V800R022C10
SA)

NetEngine 8000 M Series Integrated Service Card SA Service


CR8S8MSA4GM0 Service awareness
4Gbps Capacity RTU

Data redundancy
NetEngine 8000 M Series VSU Redundancy Elimination Basic
CR8D0DREA0C1 elimination,
Configuration (Including 1 VSUP-100+4Gbps Capacity for DRE)
V800R022C10

RTU
Order Name Description Remarks

CR8SM004S1C0 NetEngine 8000 M Series Flexible Card 4*155M 03033YLL, V800R022C10

11
Order Name Description Remarks
POS Port Enable RTU

NetEngine 8000 M Series Flexible Card 4*622M


CR8SM004S4C0 03033YLL, V800R022C10
POS Port Enable RTU

V800R022C00

Note: Number of RTUs to be


NetEngine 8000 M Series Private Network Slicing configured = Number of FlexE
CR8S0SL002C0
RTU(per 2 Slices RTU) ports x Number of slices required
by each port /2 (number of slice
IDs supported by each RTU)

NetEngine 8000 M Series Private Line Slicing


CR8S0SL032C0 V800R022C00
RTU(per 32 Slices RTU)

Software Configuration

Software License for NetEngine 8000 M4


Order Name Description Remarks

N1-N8KM4F-LIC N1-NetEngine 8000 M4 Series Foundation SW License

N1-N8KM4A-LIC N1-NetEngine 8000 M4 Series Advanced SW License

N1-NetEngine 8000 M4 Series Foundation to Advanced SW


N1-N8KM4F2A-LIC
License

N1-NetEngine 8000 M4 Series Time Synchronization


N1-N8KM4TMSY-LIC
Function License

N1-N8KM4SRV6-LIC N1-NetEngine 8000 M4 Series SRv6 Function License

N1-N8KM4SLI-LIC N1-NetEngine 8000 M4 Series Port Slicing Function License

N1-N8KM4MACS-LIC N1-NetEngine 8000 M4 Series MACsec Function License

N1-N8KM4IPS-LIC N1-NetEngine 8000 M4 Series IPsec Function License

N1-N8KM4BNG-LIC N1-NetEngine 8000 M4 Series BNG Function License

N1-NetEngine 8000 M4 Series Subscribers Quantity(1k


N1-N8KM4S1K-LIC
Subscribers)

N1-N8KM4MED-LIC N1-NetEngine 8000 M4 Media Fabric Function License

N1-N8KM4IFE-LIC N1-NetEngine 8000 M4 Series IFIT Enhanced Package

N1-N8KM4OAM-LIC N1-NetEngine 8000 M4 Series Smart OAM Package

N1-N8KM4F-SNS N1-NetEngine 8000 M4 Foundation SW License SnS

12
Order Name Description Remarks

N1-N8KM4A-SNS N1-NetEngine 8000 M4 Advanced SW License SnS

N1-NetEngine 8000 M4 Foundation to Advanced SW License


N1-N8KM4F2A-SNS
SnS

N1-NetEngine 8000 M4 Time Synchronization Function


N1-N8KM4TMSY-SNS
License SnS

N1-N8KM4SRV6-SNS N1-NetEngine 8000 M4 SRv6 Function License SnS

N1-N8KM4SLI-SNS N1-NetEngine 8000 M4 Port Slicing Function License SnS

N1-N8KM4MACS-SNS N1-NetEngine 8000 M4 MACsec Function License SnS

N1-N8KM4IPS-SNS N1-NetEngine 8000 M4 IPsec Function License SnS

N1-N8KM4BNG-SNS N1-NetEngine 8000 M4 BNG Function License SnS

N1-N8KM4MED-SNS N1-NetEngine 8000 M4 Media Fabric Function License SnS

N1-NetEngine 8000 M4 IFIT Enhanced Package License


N1-N8KM4IFE-SNS
SnS

N1-N8KM4OAM-SNS N1-NetEngine 8000 M4 Smart OAM Package License SnS

N1-N8KM4ZTA-LIC N1-NetEngine 8000 M4 Zero Trust Access Function License V8R22C10

N1-NetEngine 8000 M4 Host-based Intrusion Prevention


N1-N8KM4HIPS-LIC V8R22C10
System Function License

N1-NetEngine 8000 M4 Configuration Check Function


N1-N8KM4CC-LIC V8R22C10
License

N1-NetEngine 8000 M4 G-SRv6 32bit SRH Compression


N1-N8KM4SRV6D1-LIC V8R22C10
Function License

N1-NetEngine 8000 M4 G-SRv6 16bit SRH Compression


N1-N8KM4SRV6D2-LIC V8R22C10
Function License

N1-NetEngine 8000 M4 Zero Trust Access Function License


N1-N8KM4ZTA-SNS1Y V8R22C10
SNS

N1-NetEngine 8000 M4 Host-based Intrusion Prevention


N1-N8KM4HIPS-SNS1Y V8R22C10
System Function License SNS

N1-NetEngine 8000 M4 Configuration Check Function


N1-N8KM4CC-SNS1Y V8R22C10
License SNS

N1-N8KM4SRV6D1- N1-NetEngine 8000 M4 Series G-SRv6 32bit SRH


V8R22C10
SNS1Y Compression Function License SnS

13
Order Name Description Remarks

N1-N8KM4SRV6D2- N1-NetEngine 8000 M4 Series G-SRv6 16bit SRH


V8R22C10
SNS1Y Compression Function License SnS

Optical/Electrical Transceivers
400Gbps Optical Transceiver

Order Name Description Remarks

High Speed Transceiver,QSFP-DD FR4-4*100Gb/s PAM4(1310nm


OSK002N01
Band)-425Gb/s--3.3dBm-3.5dBm--7.6dBm-LC straight-SMF-2km

High Speed Transceiver,QSFP-DD LR8-8*56Gb/s PAM4(1310nm)-


OSK010N02
425Gb/s--2.8dbm-5.3dbm--9.1dbm-LC-SMF-10km

High Speed Transceiver,-QSFP-DD ER8-8*50Gb/s PAM4(1310nm


OSK040N02
Band),-425Gb/s--0.6dBm-6.4dBm--16.1dBm-LC straight,SMF,40km

High Speed Transceiver,QSFP-DD,193.7THz,478.75Gb/s,-10dBm,-


OSK080N04
6dBm,-20dBm,LC,SMF,ZR(with OA)

100Gbps Optical Transceiver

Order Name Description Remarks

High Speed Transceiver,QSFP28,850nm,100G,-8.4dBm,2.4dBm,-


OMND10N13 Breakout
10.3dBm,MPO,MM,0.1km,OM4

High Speed Transceiver,QSFP28,1310nm,4*25GBase,-


OSN020N15
6.5dBm,2.5dBm,-9.8dBm,LC/PC,2km (100GBASE-CWDM4)

High Speed Transceiver,QSFP28,1310nm,100G,-4.3dBm,4.5dBm,-


OSN010N24
8.6dBm,LC,SMF,10km

QSFP28-100G- High Speed Transceiver,QSFP28,1310nm,100G,3dBm,6.5dBm,


1310nm-80km-SM -30dBm,LC,SMF,80km

High Speed Transceiver,CFP2,4*25Gb/s(1310nm


OSN010N09 Band),103.125Gb/s,-4.3dBm,4.5dBm,-10.6dBm,LC
straight,SMF,10km

QSFP28-100G- High Speed Transceiver,QSFP28,1310nm,100G,-2.9dBm,2.9dBm,-


1310-40km-SM 20.9dBm,LC,40km

QSFP28-100G- High Speed Transceiver,QSFP28,1310nm,100G,2dBm,6.5dBm,-


1310-80km-SM 28dBm,LC,SMF,80km

CFP2-Coherent- High Speed Transceiver,CFP2,C extend band tunable,50GHz ITU


DCO-100G-SM grid,134.7Gbit/s,-10dBm~1dBm,-30dBm,LC,SMF

14
50Gbps Optical Transceiver

Order Name Description Remarks

High Speed Transceiver,QSFP28,1311nm,50Gb/s,-


OSL010N01
4dBm,4.2dBm,-8.8dBm,LC,SMF,10km

High Speed
QSFP28-50G-
Transceiver,QSFP28,1311nm,50Gb/s,1.5dBm,8dBm,-
1311nm-40km-SM
15dBm,Straight LC,SMF,40km

QSFP28-50G- High Speed Transceiver-QSFP28-1310nm-50G-9.5dBm--


1310nm-80km-SM 30dBm-LC-SMF-80km

QSFP28-50G- BiDi Transceiver,QSFP28,1271nm(TX)/1331nm(RX),50G,-


Breakout
BIDI-10km-SM-2 4.5dBm,4.2dBm,-8.9dBm,LC,10km

QSFP28-50G- BiDi Transceiver,QSFP28,1331nm(TX)/1271nm(RX),50G,-


Breakout
BIDI-10km-SM-1 4.5dBm,4.2dBm,-8.9dBm,LC,10km

BiDi
QSFP28-50G-
Transceiver,QSFP28,1295nm(TX)/1309nm(RX),50G,1.5dBm,8 Breakout
BIDI-40km-SM-2
dBm,-13.5dBm,LC-SMF-40km

BiDi
QSFP28-50G-
Transceiver,QSFP28,1309nm(TX)/1295nm(RX),50G,1.5dBm,8 Breakout
BIDI-40km-SM-1
dBm,-13.5dBm,LC,SMF,40km

40Gbps Optical Transceiver

Order Name Description Remarks

High Speed Transceiver,QSFP+,850nm,41.25Gbps,-


OMXD30010 Breakout
7.6dBm,0.5dBm,-9.5dBm,MPO,MMF,0.15km

High Speed Transceiver,QSFP+,1310nm,41.25Gbps,-


OMXD30009 Breakout
7dBm,2.3dBm,-11.5dBm,LC,SMF,10km

25Gbps SFP28 Optical Transceiver

Order Name Description Remarks

SFP28-25G- High Speed Transceiver,SFP28,850nm,25G,-8.4dBm,2.4dBm,-


850nm-0.1km-MM 10.3dBm,LC,MM,0.1km

10Gbps SFP+ Optical Transceiver

Order Name Description Remarks

OSX040N03 Optical Transceiver(SFP+,850nm,10Gb/s,-7.3~-1dBm,-9.9dBm,LC,

15
Order Name Description Remarks
MM,0.3km)

Optical Transceiver(SFP+,1310nm,10Gb/s,-8.2~0.5dBm,-
OSX001002
12.6dBm,LC,SM,10km)

XFP SFP+ Transceiver-SFP+-1310nm-10G/1G--8.2dbm-0.5dbm-


OSX010N13
Single-mode-14.4dbm-LC-10km

Optical Transceiver(SFP+,1550nm,9.95~11.1Gb/s,-4.7~4dBm,-
OMXD30002
14.1dBm,LC,SM,40km)

Optical Transceiver(SFP+,1550nm,9.953~10.3125Gb/s,0~4dBm,-
OSX080N04
24dBm,LC,SM,80km)

1.25Gbps eSFP Optical Transceiver

Order Name Description Remarks

Optical Transceiver(eSFP,850nm,2.125Gb/s(Multi rate),-9.5~-


OMGD50N02
2.5dBm,-17dBm,LC,MM,0.5km)

Optical transceiver(eSFP,1310nm,1.25Gb/s,-9dBm~-3dBm,-
OSG010N05
20dBm,LC,SM,10km)

Optical Transceiver(eSFP,1310nm,1.25Gb/s,-5~0dBm,-
OSG040N02
23dBm,LC,SM,40km)

Optical Transceiver,eSFP,1550nm,1.25Gb/s,-2~5dBm,-
OSG080N01
23dBm,LC,SM,80km

Optical Transceiver(eSFP,850nm,2.125Gb/s(Multi rate),-9.5~-


OMGD50N02
2.5dBm,-17dBm,LC,MM,0.5km)

1.25Gbps eSFP BIDI Optical Transceiver

Order Name Description Remarks

SFP-GE-LX- BiDi Transceiver,eSFP,Tx1310nm/Rx1490nm,1.25Gb/s,-


SM1310-BIDI 9dBm,-3dBm,-19.5dBm,LC,SM,10km

SFP-GE-LX- BiDi Transceiver,eSFP,Tx1490nm/Rx1310nm,1.25Gb/s,-


SM1490-BIDI 9dBm,-3dBm,-19.5dBm,LC,SM,10km

Optical Transceiver,eSFP,1310nm(Tx)/1490nm(Rx),1.25Gb/s,-
OGEBIDI41
2dBm,3dBm,-23dBm,LC,SM,40km

Optical Transceiver,eSFP,1490nm(Tx)/1310nm(Rx),1.25Gb/s,-
OGEBIDI40
2dBm,3dBm,-23dBm,LC,SM,40km

16
1Gbps Optical Transceiver

Order Name Description Remarks

SFP-GE-LX- BiDi Transceiver,eSFP,Tx1310nm/Rx1490nm,1.25Gb/s,-


SM1310-BIDI 9dBm,-3dBm,-19.5dBm,LC,SM,10km

SFP-GE-LX- BiDi Transceiver,eSFP,Tx1490nm/Rx1310nm,1.25Gb/s,-


SM1490-BIDI 9dBm,-3dBm,-19.5dBm,LC,SM,10km

Optical Transceiver,eSFP,1310nm(Tx)/1490nm(Rx),1.25Gb/s,-
OGEBIDI41
2dBm,3dBm,-23dBm,LC,SM,40km

Optical Transceiver,eSFP,1490nm(Tx)/1310nm(Rx),1.25Gb/s,-
OGEBIDI40
2dBm,3dBm,-23dBm,LC,SM,40km

Optical functional module,1000BASE-T -SFP RJ45Electrical


OEGD01N02
Module,Auto Negotiate,100m,-40~85degC

155Mbps eSFP Optical Transceiver

Order Name Description Remarks

SFP28-25G- High Speed Transceiver,SFP28,1310nm,25G,-7dBm,2dBm,-


1310nm-300m-SM 10.5dBm,LC,SMF,0.3km

SFP28-25G- High Speed Transceiver,SFP28,1310nm,25G,-7dBm,2dBm,-


1310nm-10km-SM 11.3dBm,LC,SMF,10km

eSFP-FE-LX- Optical Transceiver(eSFP,1310nm,STM1,-15dBm~-8dBm,-


SM1310 28dBm,Singlemode,LC,15Km)

622M SFP/eSFP Optical Transceiver

Order Name Description Remarks

Optical Transceiver(eSFP,1310nm,STM4,-15dBm~
OSH015N05
-8dBm,-30dBm,Singlemode,LC,15Km)

eSFP-1310nm-L- Optical Transceiver(eSFP,1310nm,STM4,-3dBm~


4.1 2dBm,-30dBm,Singlemode,LC,40km)

Optical Transceiver,eSFP,1550nm,STM4,-3~2dBm,
OSH080N01
-30dBm,LC,SM,80km

Software Upgrade Paths


Visit Software Upgrade Paths or contact local Huawei engineers for more detailed information.

17
For More Information
For more information about the NetEngine 8000 series router, visit https://e.huawei.com or contact us in the following
ways:

⚫ Global service hotline: https://e.huawei.com/en/service-hotline


⚫ Logging in to the Huawei Enterprise technical support web: https://support.huawei.com/enterprise/
⚫ Sending an email to the customer service mailbox: [email protected]

Copyright © Huawei Technologies Co., Ltd. 2023. All rights reserved.


No part of this document may be reproduced or transmitted in any form or by any means without prior written
consent of Huawei Technologies Co., Ltd.

Trademarks and Permissions

and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective holders.

Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the
customer. All or part of the products, services and features described in this document may not be within the
purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and Huawei Technologies Co., Ltd.
recommendations in this document are provided "AS IS" without warranties, guarantees or representations of
Address:Huawei Industrial Base Bantian,
any kind, either express or implied.
Longgang Shenzhen 518129
The information in this document is subject to change without notice. Every effort has been made in the
People's Republic of China
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied. Website: www.huawei.com

18

You might also like