Liebert CRV: In-Row Cooling Solution
Liebert CRV: In-Row Cooling Solution
19-FEB-2019
WHAT HAS CHANGED IN DATA CENTERS?
Preliminary planning document, subject to consultation, negotiation or other local legal requirements 2
FROM THE SERVER TO THE RACK
TO THE DATA CENTER ROOM
Vertiv has different solutions available for any rack and Data Center layout
• One of the solutions is to place the cooling unit next to the server
and the IT rack
• Thermal Management units have the capability to adapt to the
servers’ needs in terms of air flow and air temperature
LIEBERT CRV – ROW BASED COOLING
▪ DX and CW Version
▪ 300 and 600 mm wide frame
▪ Wide Range: 4 basic capacities in DX and 5 in CW version
▪ High Efficiency:
▪ EC Fans
▪ Inverter driven scroll compressor on the 300mm frame
▪ Digital Scroll on the 600 mm frame
▪ High Density Applications: up to 10kW/Rack in open architecture
▪ Rich features: Humidifier, Re-heat, ATS, and more…
Direct Expansion (DX) Chilled Water (CW)
*Additional Notes 4
PRODUCT POSITIONING - FEATURES
Liebert CRV
Fully Featured Thermal Management Unit
• Cooling
• Humidification / Dehumidification
• Reheating
• Up to F5 filtration class
• Air Discharge Baffles
• Dual Power Supply with ATS
LIEBERT® CRV CW – MAIN FEATURES
Preliminary planning document, subject to consultation, negotiation or other local legal requirements 6
LIEBERT® CRV DX – MAIN FEATURES
Preliminary planning document, subject to consultation, negotiation or other local legal requirements 7
DX VERSIONS: DIGITAL SCROLL COMPRESSOR –
MODULATING CAPACITY
Only 600 mm
Digital Scroll Compressor models
modulates the capacity thus
guarantees the right temperature
All DX models
EC Fans
Deliver always just the required air flow
⚫ Benefits:
• In the event of a fan failure, the functioning fan will increase to max speed to help compensate for the
lost fan. Plus, when multiple Liebert CRV units are Teamworked together, the other units will also
assist the impaired unit
• The unit will automatically ramp to max fan speed when the room is overheated.
Example: Heat soaked, post-power failure condition. Extra airflow provides extra capacity to return to the room
set point FASTER.
FIELD ADJUSTABLE MODULAR BAFFLES
Getting the air where it needs to be – close to the IT Available for the
equipment Entire Range
Air discharge
to the left
Air discharge to
Readjust baffles as cooling needs the right
and room layout changes
Air discharge to
both sides
VERTIVTM ICOMTM CONTROL
• 6 Control Modes
• Up to 10 rack-installed temperature sensors per unit
• Graphical User Interface for local control and integration to Network Management System
• Teamworking – Unit to unit communication for highest availability and performance
optimization
SENSORS
*Additional Notes 18
SIX CONTROL MODES
Six control modes to independently match the server heat load and airflow as
server operations change
Cooling Capacity
(via Digital Scroll Compressor or CW Valve)
Sensors Supply Air Remote Rack Return Air
Airflow (via Factory
Supply Air Setting
Variable Speed
Default with
EC Plug Fans) Remote Rack rack sensors
= Available
= Recommended With and Without Containment
Preliminary planning document, subject to consultation, negotiation or other local legal requirements 19
EASY INSTALLATION - TOP AND BOTTOM CONNECTIONS
FOR ALL MEDIA
Piping
Piping
CONDENSATE MANAGEMENT AND
DUAL POWER SUPPLY
ATS location in
⚫ Condensate pump available for all models 600 mm models
⚫ All service and Maintenance can be done through the front or the back side of the unit
⚫ No Side access required
Combination with
• Open or closed architecture
Smart Aisle
• Heat densities up to 10 kW / Rack
in Open Architecture
LIEBERT® CRV - SUMMARY