0% found this document useful (0 votes)
66 views8 pages

Intelineo 6000 1.3.0 New Features List

The document summarizes the new features and changes in software version 1.3.0 of the InteliNeo 6000 controller. Key updates include the addition of a "write on change" option for Modbus registers, block reading of Modbus registers, and controls for voltage and frequency protections. Bug fixes addressed issues with redundant CAN modules and shutdown protections. The release also included documentation and firmware files to support the new version.

Uploaded by

mher.bakalian
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
66 views8 pages

Intelineo 6000 1.3.0 New Features List

The document summarizes the new features and changes in software version 1.3.0 of the InteliNeo 6000 controller. Key updates include the addition of a "write on change" option for Modbus registers, block reading of Modbus registers, and controls for voltage and frequency protections. Bug fixes addressed issues with redundant CAN modules and shutdown protections. The release also included documentation and firmware files to support the new version.

Uploaded by

mher.bakalian
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

InteliNeo

6000
Controller for parallel hybrid
microgrid applications

SW version 1.3.0
1 General information 2
2 Changes in the version 1.3.0 3
3 Changes in the version 1.2.0 4
4 Changes in the version 1.1.1.1 6
5 Available related information 7
6 Notes 8

Copyright © 2023 ComAp a.s.


Written by ComAp
Prague, Czech Republic
ComAp a.s., U Uranie 1612/14a,
170 00 Prague 7, Czech Republic
Tel: +420 246 012 111
E-mail: [email protected], www.comap-
control.com New Features List
1 General information
1.1 Version information
This FW version is compatible with:
InteliConfig version 2.38.0.38 and newer
InteliSCADA version 2.5.0.10 and newer
InteliVision 5.2 FW 1.6.1.1 and newer

1.2 Clarification of Notation


Note: This type of paragraph calls the reader’s attention to a notice or related theme.

IMPORTANT: This type of paragraph highlights a procedure, adjustment etc., which can cause a
damage or improper function of the equipment if not performed correctly and may not be clear at
first sight.

WARNING: This type of paragraph highlights a procedure, adjustment etc., which can cause a
damage or improper function of the equipment if not performed correctly and may not be clear at
first sight.

Example: This type of paragraph contains information that is used to illustrate how a specific function
works.

InteliNeo 6000 1.3.0 New Features List 2


2 Changes in the version 1.3.0
2.1 New features
Option "Write On Change" has been implemented in functionality Modbus Master. See the "Refresh Type"
parameter in datapoint configuration in InteliConfig.
The Function Modbus Registers Block Reading has been implemented. User is allowed to create the
datapoints and assign them a register group. The Group of registers is then read at once using the one
modbus poll request. See configuration of a modbus user device in InteliConfig.
Option to select if the Voltage protection are evaluated upon the Ph-Ph Voltage or Ph-N Voltage. See the
setpoint Basic Settings/ Voltage Settings/ Evaluated Voltage Protections.
Vector Shift and ROCOF protection settings available in MINT application. See the Setpoints in the group
Lost Of Mains Protections.
Sunrise/Sunset function has been implemented. See the Setpoints in the group Scheduler/
Sunrise/Sunset Function.
The function Hot Swap Redundancy supports two independent redundant sets of CAN peripheral
modules.

2.2 Bug Fixes


The User protection configured as a Shutdown type and with fast reaction was not evaluated as fast. The
bug has been fixed.

InteliNeo 6000 1.3.0 New Features List 3


3 Changes in the version 1.2.0
IMPORTANT: The Hot Swap functionality is temporarily not recommended for use in
InteliNeo6000. This issue is present only in this version.

3.1 New features


In on-grid operation (with InteliMains), when only BESS and PV is connected to the mains (no genset).
InteliNeo now accepts the Low Target SOC and High Target SOC limits and discharging / charging is
stopped regardless the InteliMains request.
Disabling of protections BESS >V, BESS >>V, BESS <V, BESS >f, BESS <f leads to blocking of the BCB
Close Command. Now this situation is signalized by alarm LAI BCB Closing Is Blocked.
Operation without the PVCB is now supported in InteliNeo. Use the settings Setpoint: Process
Control/Breaker Control/PVCB Control Mode = Not Installed.
The Follow Mode in PVCB Control was added. This option allows opening of the PVCB unexpectedly e.g.
In case of lost of mains. In this mode the alarm PVCB Fail is suppressed. Set the Setpoint: Process
Control/Breaker Control/PVCB Control Mode = Follow.
Some selected parameters in the controller can be newly renamed in the InteliConfig even in default
language e.g. User Buttons, Remote Control Registers, Timers, pulse counters, etc.
The solution of the wind up effect of curtailment function was integrated. In case of need of the curtailment
the limitation always starts on the actual level of the PV output.
The PV control (Curtailment Output) can be programmed to have ramp up/down time in seconds. The
maximal rate of the output change is limited by the ramp. See the setpoints Curtailment/PV/WT Ramp Up
and PV/WT Ramp Down.
New option "Soft Bus Energize" was added in DC Precharge sequence. Activation of the LBI Soft Bus
Energize during the start sequence of the BESS allows starting with closed BCB and soft energizing of the
bus.
The new function of PV Curtailment Counter was integrated. The controller counts the energy lost during
the curtailment, reports the value of lost PV output and calculates the total loss of energy from the
theoretical output calculated at the site of generation. The function requires use of a irradiation sensor
located at the PV array.
For BESS operated in the U-f Control mode, the controller supports additional analog output for BESS
PCS voltage and frequency regulation. See analog values for Frequency/Load Control for BESS
Frequency Required, BESS Frequency Offset, BESS P Required %. See analog values Voltage/PF
Control for BESS Voltage Required, BESS Voltage Offset, BESS Q Required %.

3.2 Bug Fixes


Some limits of the modbus client functionality was fixed, e.g. Limit of 128 polls in the configuration of the
modbus client functionality.
Soft unload process of the BESS in on-grid application was fixed. Originally the BESS stays fully loaded
until the soft unload ramp elapsed.
In on-grid application, where curtailment function only started limiting the PV output if the BESS reached
the request from the InteliMains. Scenario of PV > BESS Nominal Power led to the situation that PV was
not curtailed to fulfill the request of zero Export. The bug was fixed.

InteliNeo 6000 1.3.0 New Features List 4


The SD Protection configured as a "Fast Protection" did not trip the BCB in the short (20ms) application
loop. The Problem was fixed.
Number of minor bugs were fixed.

InteliNeo 6000 1.3.0 New Features List 5


4 Changes in the version 1.1.1.1
SW version 1.1.1.1 is UL witness tested for Multiple Generator Paralleling Control Equipment

InteliNeo 6000 1.3.0 New Features List 6


5 Available related information
Documents (*.pdf) Description
InteliNeo 6000 1.3.0 Global The manual provides general information how to install and operate
Guide InteliNeo 6000 controller.
InteliNeo 6000 Datasheet Basic technical information about the InteliNeo 6000 controller.

Table 1.1 Available documentation

5.1 Available files


Firmware (*.exe)
For InteliNeo 6000
InteliNeo6000-Product-Suite-1.3.0.exe

Table 1.2 Available firmware

Archives (*.aig4)
For InteliNeo 6000
InteliNeo6000-HC-1.3.0.aig4
InteliNeo6000-HC-ExtendedFeatures-1.3.0.aig4

Table 1.3 Available archives

InteliNeo 6000 1.3.0 New Features List 7


6 Notes
6.1 Document history
Revision number Related sw. version Date Author
4 1.3.0 12.12.2023 ComAp
3 1.3.0 16.11.2023 ComAp
2 1.2.0 18.10.2023 ComAp
1 1.2.0 17.10.2023 ComAp