0% found this document useful (0 votes)
40 views

Ahmer PDF

Typhoon Solar Energy has proposed a 6.5KW hybrid solar system for Mr. Ahmer located in Okara, Pakistan. The system would include 11 Longi solar panels producing a total of 6.5KW, a Crown 5.6KW hybrid inverter, standard aluminum structure, wiring, and installation within 1 week of payment. The total cost of the system is 1,227,490 PKR with a payback period of approximately 3.3 years based on estimated annual electricity savings of 374,400 PKR. The proposal includes warranty and payment terms.

Uploaded by

iamhassaanexpert
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
40 views

Ahmer PDF

Typhoon Solar Energy has proposed a 6.5KW hybrid solar system for Mr. Ahmer located in Okara, Pakistan. The system would include 11 Longi solar panels producing a total of 6.5KW, a Crown 5.6KW hybrid inverter, standard aluminum structure, wiring, and installation within 1 week of payment. The total cost of the system is 1,227,490 PKR with a payback period of approximately 3.3 years based on estimated annual electricity savings of 374,400 PKR. The proposal includes warranty and payment terms.

Uploaded by

iamhassaanexpert
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

TYPHOON SOLAR ENERGY

(PVT) LTD

Financial Proposal for: 6.5KW Hybrid-Solar System


Client Name: Mr. Ahmer
Location: Okara,
To,
Mr. Ahmer,
Dear Sir,
"Typhoon Solar Energy"is oneof the experienced companies in design, Energy
Solution and cost saving solar projects.

Our mission is to provide high quality and reliable products to customers. We use our air
technical expertise to help our customers, it is our competitive advantage. Our practice
approach to technical issues enables our customers to understand and implement cost-
effective solution is design.

We "Typhoon Solar Energy " do the design as the turnkey project which would be hassle
free to the clients. We understand that you are looking for trustworthy vendor for design and
energy solution for your existing energy shortage.

Another important strength of our company is time management. We render our maximum
efforts to fulfill customer requirements in achieving best Quality, timely delivery with
competitive cost.

We welcome your interest and participation to be a part of our company through which both
of our organization would grow.

Sales Department
Typhoon Solar Energy
Tel: 0303-8798131
[email protected]
Summary of Proposal
Total proposed PV Capacity meets 6.5kw system.
 LONGI HIMO6 Solar Panel 585W Equivalent
 Crown 5.6kw Hybrid - Inverter
 Standard Structure (designed as per Longitude and Latitude Angle) will be Used.
 Special emphasize on reducing the ohmic laws.
 Installation Time: 1 Week after payment.
 Minimum required un-shaded area is 1200feet square
Work Description: INSTALLATION OF 6.5KW Hybrid - SOLAR SYSTEM

Sr. ITEM DETAILS UNIT QTY QTY UNIT PRICE TOTAL


No

1 Solar Panels LONGI HIMO6 Solar Panel 585W Each


11 31590 347490

2 Inverter Crown 5.6kw Hybrid Inverter Each 1


210000 210000
3 Structure Standard Structure Aluminum Each 1
55000 55000

4 Flexible DC Wire 4mm PVC,PVC tin coated copper Per. Job


DC Cable for DC Circuit 1 60000 60000
Commissioning Fast, new age cables
5 AC Wire 6mm single-core, (AI/XLPE/PVC) As per site
Aluminum Conductor requisite 1 40000
Newage, Fast, Millinum Cables 40000

6 LV Panels Ac Breakers, Surge protection 1


devices and Energy analyzer. Each 40000 40000

Miscellaneous Cable Tray , Rawl Bolts, Cable Ties,


7 Flexible Pipe Per. Job As Per
1 30000
Thimbles , Wire Tapes Requirement

Earthing & Boring Conventional Earthing, Earthing


Copper Bus bars, Copper Wire 10mm,
8 Lightening Arrestor, Earthing Wire Per. Job As Per
1 80000
10mm for frames shorting, 10mm for Working
DC Earthing Bore
Civil Work Civil Pads 7*16 feet Per. Job 1 As Per
9 15000
Working
Installation Labor, Electrical Work, Mechanical 1 As Per
10 Work Transportation Per. Job 20000
Working
Net Meter Green Meter (1-Month)
11 0 1 110000 110000
12 Backup Battery: Osaka
Power: 160Ah 0 4 55000 220000
18 % GST ON ALL Items Except( Item @ Serial No.1 Solar Panels) 0 0
TOTAL 0 1227490

Warranty
After sale Services Free of cost 1 Years
Inverter Warranty 5 Years
Solar Panels Warranty 30 Years
Terms and Conditions

 Quotation is valid for 3 Days.


 Quotation must be revised after validity period.
 Quoted Price are based on USD
 All the warranties are offered by the respective manufacturers. The manufacturers terms and
conditions will be applied for any warranty claims
 Payment is nonrefundable.
 The Company will not responsible for any type of guarantee in case of installation from
unauthorized Person
 80% advance payment.
 10%payment when material will be provided on site.
 10%payment after completion.
 12 Years replacement warrantyof Solar Panels and 25 Years designed warranty.
 10 Year warranty of Inverter.
 Delivery time 12-14 days after all technical and commercial issues have been resolved.
 In case of non-availability or solar panel size/brand , alternate Tier1 Solar Panels will be used
Payback Period
 Average daily unit generated by 1KW: 4 UNITS
 Average daily unit generated by 6.5kw: 26 UNITS
 Average monthly unit generated by 6.5kw: 780 UNITS
 Averageannually unitgenerated by 6.5kw: 9360 UNITS
 Considering Average unit rate: PKR40/KWH
 Annual Saving in electricity bill: 374400/-
 Payback period comes at approximately: 3.3Years
 Increase in electricity tariff will resultineven lower payback period.
 Above all calculation is based on average values. This payback
period will Decrease in real time
(V2)

LR5-72HTH
565~585M
Suitable for Distribution Market

Simple design embodies modern style

Better energy generation performance

High-quality module guarantees long-term reliability

15-year W rranty for


15 Materials and Processing

25-year Warranty for Extra


25 Linear Power Output

Complete System and


Product Certifications

IEC 61215, IEC 61730, UL 61730


ISO9001:2015: ISO Quality Management System
ISO14001: 2015: ISO Environment Management System
ISO45001: 2018: Occupational Health and Safety
IEC62941: Guideline for module design qualification and type approval
LR5-72HTH 565~585M
22.6% 0~3% <1.5% 0.40%
MAX MODULE POWER FIRST YEAR YEAR 2-25
EFFICIENCY TOLERANCE POWER DEGRADATION POWER DEGRADATION

Additional Value

25-Year Power Warranty

100
98.5%
88.90%

88.9%

Units: mm
2278
1400
790
40

25 D C
1 5 10 15 20
Mechanical Parameters
Cell Orientation 144 (6×24)

B
B
Junction Box IP68
Output Cable 4mm2, +400, -200mm/±1400mm

1093
1134
length can be customized

Glass Single glass, 3.2mm coated tempered glass


Frame Anodized aluminum alloy frame
Weight 27.2kg

A A
Dimension 2278×1134×30mm

30

30
9 7
Tolerance:

14

10
Packaging 36pcs per pallet / 180pcs per 20’GP / 720pcs per 40’HC Length: ±2mm
Width: ±2mm 4.5 C 3.5 D A-A
30 15
B-B

Electrical Characteristics STC : AM1.5 1000W/m2 25℃ NOCT : AM1.5 800W/m2 20℃ 1m/s Test uncertainty for Pmax: ±3%

Module Type LR5-72HTH-565M LR5-72HTH-570M LR5-72HTH-575M LR5-72HTH-580M LR5-72HTH-585M


Testing Condition STC NOCT STC NOCT STC NOCT STC NOCT STC NOCT
Maximum Power (Pmax/W) 565 422 570 426 575 430 580 433 585 437
Open Circuit Voltage (Voc/V) 51.76 48.60 51.91 48.74 52.06 48.88 52.21 49.02 52.36 49.16
Short Circuit Current (Isc/A) 14.01 11.31 14.07 11.36 14.14 11.42 14.20 11.47 14.27 11.52
Voltage at Maximum Power (Vmp/V) 43.61 39.79 43.76 39.93 43.91 40.07 44.06 40.20 44.21 40.34
Current at Maximum Power (Imp/A) 12.96 10.61 13.03 10.68 13.10 10.73 13.17 10.78 13.24 10.84
Module Efficiency(%) 21.9 22.1 22.3 22.5 22.6

Operating Parameters Mechanical Loading


Operational Temperature -40℃ ~ +85℃ Front Side Maximum Static Loading 5400Pa
Power Output Tolerance 0 ~ 3% Rear Side Maximum Static Loading 2400Pa

Voc and Isc Tolerance ±3% Hailstone Test 25mm Hailstone at the speed of 23m/s

Maximum System Voltage DC1500V (IEC/UL)


Maximum Series Fuse Rating 25A
Nominal Operating Cell Temperature 45±2℃
Temperature Ratings (STC)
Protection Class Class II Temperature Coefficient of Isc +0.050%/℃
Temperature Coefficient of Voc -0.230%/℃
Fire Rating UL type 1 or 2
IEC Class C Temperature Coefficient of Pmax -0.290%/℃

Specifications included in this datasheet


No.8369 Shangyuan Road, Xi'an Economic And are subject to change without notice.
Technological Development Zone, Xi'an, Shaanxi, China. LONGi reserves the right of final
interpretation(
. 20230926V19)DG
Web: www.longi.com