G65 Flanged (HORNOS)

This document provides technical specifications for a Rotary Gas Meter model G65 in hard metric sizing with a 50mm (2 inch) flange connection. Key specifications include a maximum operating pressure of 12 bar, a flow capacity of 100 cubic meters per hour, and a rangeability of 1:160. Dimensions for the meter body and connections are also provided along with flow capacity and accuracy data at different pressures. The meter uses a rotary displacement design with an instrument drive rate of 0.1 cubic meters per revolution.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
58 views2 pages

G65 Flanged (HORNOS)

This document provides technical specifications for a Rotary Gas Meter model G65 in hard metric sizing with a 50mm (2 inch) flange connection. Key specifications include a maximum operating pressure of 12 bar, a flow capacity of 100 cubic meters per hour, and a rangeability of 1:160. Dimensions for the meter body and connections are also provided along with flow capacity and accuracy data at different pressures. The meter uses a rotary displacement design with an instrument drive rate of 0.1 cubic meters per revolution.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Rotary Gas Meters

Note: AMI/AMR adaptors available upon request.


DN/ ANSI
METER WEIGHT
SIZE
PN 16 125 FF A B C D1 D2 D3 D4 D5 D6 E1 E2 (kg)
FLANGE FLANGE

171 Ø 152 142 379 416 437 461 444 445 102 102
G65 50 mm 2” 12.2-13.8
mm mm mm mm mm mm mm mm mm mm mm

G65 - HARD METRIC


HARD METRIC G65 50 mm (2”) FLANGE CONNECTION
TECHNICAL SPECIFICATION
Connection (Flange) DN/PN16 50 mm
ANSI 125FF 2”
MAOP (bar) 12
Flow Capacity (m3/h) 100
Rangeability* (up to 1:160 @ atmospheric condition,
1:160
according to EN12480 & OIML R137/1 requirement)
Start Rate (m3/h) .113
Stop Rate (m3/h) .093
Differential @ 100% Flow (mbar) 2.14
Instrument Drive Rate (m3/rev) .1
LF Pulser (Optional) (m3/pulse) .1
*Note: It should be noted, that moving parts in the meters with a greater rangeability ratio are made to high class accuracy and tight tolerances.
Improper installation, stresses on piping system due to temperature changes, settling and gas conditions can create a risk of meter rejection.

CORRECTED FLOW CAPACITY AND TYPICAL ACCURACY GUIDE

G65 METER
(SM3/H)
Gauge G65
Pressure
Qmax =
Bar
0.012 100 m3/hr

0.05 104.9
0.1 109.9
0.5 149.3
1.0 198.7
1.5 248.0
2.0 297.4
2.5 346.7
3.0 396.1
5.0 593.5
7.5 840.2
10.0 1086.9
11.0 1185.6
12.0 1284.3

GAS METERS AND ELECTRONIC INSTRUMENTS The values quoted are typical of normal production.They do not constitute a specification. Romet
Limited reserves the right to change any information in this literature without notice. All of the
Phone 905-624-1591 USA 1-800-387-3201 information and data in this literature has been carefully compiled and thoroughly checked.
However, Romet Limited will not assume responsibility for any possible omissions or errors.
www.rometlimited.com • email: [email protected] ROMET and ROMET & DESIGN are registered trademarks of Romet Limited. Romet Limited’s
gas metering technology is protected under U.S.Patent No.4,910,519 and 6,453,721 and
Canadian Patent No.1,293,568.