Orifice
Tapping of differential pressure is done by this vener contractor tap
Orifice. Since Orifice plate can be installed directly to flange of pipe,
flow measurement by this Orifice plate can be performed more
economically than by orifice plates with rings, and it is generally
suited for large diameter pipes. As for large diameter pipes of
500mm or greater, these Orifice plates are used to measure the
average value of pressure by making some differential pressure
tapping holes around the pipe and connecting thereto a loop form
pressure equalizing pipe.
The bore and bevel is the standard of limiting the plate edge thickness.
Thebevel is machined on a 45 angle to the desired edge thickness.
Unlessotherwise specified, plates will be bevelled to 1/50 of the line
I.D. or 1/8of the Orifice bore, minimum governing.
ORIFICE PLATE & FLANGE
4S ------------------------------------ 304SS
4L ------------------------------------ 304L SS
6S ------------------------------------ 316SS
6L ------------------------------------ 316L SS
Material : Plate/Flange
11 ------------------------------------ A182 F11
OP ------------------------------------ Option
4 ----------------- SW 3/4
N ------- None
Meter Run
Y ------- Include
Option
RING TYPE ORIFICE
DESCRIPTIONS
Orifice Ring Assemblies are used for flow measurement of smaller or medium sized pipes at lower pressures
Each assembly consists of one orifice plate and two orifice rings, Differential pressures are taken out in a corner
tap system.
Orifice Blocks, which are of a unit-construction type and provide higher pressure ratings than the Orifice Ring
Assemblied, also are abvailable. Differential pressures are taken out in a corner tap system.
SPECIFICATIONS
ORIFICE BORE TYPE : MATERIALS
- Concentric Square Edged Orifices - Ring and Pressure Tap Nipple : C.S, 304SS, 316SS
- Quadrant Edged Orifices. - Plate : 304SS, 316SS, 316L, Monel, other
- Minimum quadrant edged orifice diameter 4.5mm -Tab Handle : 304SS, 316SS
- Minimum quadrant edged radius 0.5mm
TAP CONNECTION
FLOW CALCULATION STANDARDS : - PT 1/2 or 1/2 NPT male,
- ISO5167, JIS Z 8762, ASME, KS A 0612 - Socket weld, butt weld or flange.(Flange rating to be
the same as the of the process pipeline)
FLANGE RATING
- JIS5, 10, 20, 30kg/cm2 ANSI 150#, 300# GASKET:
Material : Asbestos, Non-Asbestos, Teflon
Thickness :1.5mm,2.0mm,3.0mm
RING TYPE ORIFICE
MODELS SUFFIX CODES DESCRIPTION
Ring Type
Orifice DHOF-RING ----------------------------------------------------------- Coner Taps Plate & Ring
4S ------------------------------------ 304SS
4L ------------------------------------ 304L SS
6S ------------------------------------ 316SS
6L ------------------------------------ 316L SS
Material : Plate/Flange
11 ------------------------------------ A182 F11
OP ------------------------------------ Option
4 ----------------- SW 3/4
0 ----------------- Option
O ------- Option
Option
HIGH PRESSURE ORIFICE
DESCRIPTION
These flanges include both the welding neck type used
with orifice plates or orifice plates with rings.
They are available in the following types
Model DHOF-RTJ
Used with Model DHOF-RTJ orifice with holding ring
for flange taps. Available only in welding neck type.
Flange faces are ring-joint types
SPECIFICATIONS
- Welding neck. Type DHOF-RTJF - Two per flange. Provided in Model DHOF-RTJF
are only available with welding neck style. the flange tap location specified in ISO5167O
Nominal
Pipe ------------------------------------------------ Pipe size in inch or mm
Size
4S ------------------------------------ 304SS
4L ------------------------------------ 304L SS
6S ------------------------------------ 316SS
6L ------------------------------------ 316L SS
Material
11 ------------------------------------ A182 F11
OP ------------------------------------ Option
4 ------------------ SW 3/4
Option
HIGH ACCURACY ORIFICE
DESCRIPTION
These flanges & meter run tube, flow straightener Include high accuracy Orifice Assembly
They are available in the following types
Model : DHOF-H
Used with Model DHOF-H orifice plate with weld neck flange, meter run tube, flow straightener, etc
L (17Di)
(12Di) (5Di)
(10Di)
SPECIFICATIONS
Meter run tube type
DHOF-H are only Assembly
DESCRIPTIONS
The restriction orifices are used for reducing fluid pressure and are designed somewhat different the orifice
plates that are used for meassuring flow rates.
There are some types of restriction orifices, including a single plate with a single hole, a single perforated
plate(having diffused holes), and a set of welded multi orifices (a multistage orifice) which are used for
high-pressure high-temperature fluids.
The bore edge of the restriction orifices can be surface-hardened with stellite welding or by nitrification.
SPECIFICATIONS
MOUNTING
- Flange, Union, Butt Weld etc
FLANGE RATING
- ANSI 150, 300, 600, 900, 1500, 2500LB RTJ
Oval Type or Octagonal Type
MATERIAL
- Carbon Steel
- 304SS, 304L SS, 316SS, 316L SS
- Ni, Cr, Mo Alloy Steel(A182 F11 to 91)
- Monel, Hastelloy, Inconel etc
RESTRICTION ORIFICE
MODELS SUFFIX CODES DESCRIPTION
4S ------------------------------------ 304SS
4L ------------------------------------ 304L SS
6S ------------------------------------ 316SS
6L ------------------------------------ 316L SS
HC ------------------------------------ Hastelloy-C276
OP ------------------------------------ Option
Option
INTEGRAL ORIFICE
DESCRIPTION
Integral Orifice is a stand-alone, orifice-based flow meter that incorporates all the following
features:
- Integral 3-valve manifold
- Integral connections between the carrier tappings and manifold
- DP transmitter, factory-mounted onto the manifold and pre-configured for the application
- Fully leak-tested and configured
DISTINCTIVE
Easy to specify
- Single ordering code covers complete flowmeter
- Only two orifice ratios simple specification process
INTEGRAL ORIFICE
Model : DHIO-FM
SPECIFICATIONS
Nominal
Pipe size in inch or mm
Pipe Size
CS Carbon Steel
4S 304SS
Material
4L 304L SS
Plate or Block /
Meter Run 6S 316SS
6L 316L SS
OP Option
000 Option
V Volumetric
Indicator
M Mass
A 4~20mA
OutPut
V 1~5V
Option
VENTURI TUBE �-1
MODEL : DHOV
DESCRIPTION
The Venturi tube is streamlined at both entrance
and exit. Standard designs are equipped with
piezo meter rings (i.e., multiple tap holes around
the periphery of inlet and throat, surrounded by an
annular ring). For measurement of slurries and
similar nonhomogenous liquids, the piezo meter
rings are usually eliminated to permit efficient
purging of the pressure tap holes. The Venturi tube
is considered the best type of head meter primary
device for measuring liquids containing large
concentrations of solids.
as a standard measurement for acceptance tests on pumping and similar equipment, the individually calibrated
Venturi tube has certain advantages. Like a calibrated orifice meter run, the calibration includes the effect o tap
characteristics.
The standard deviation of the test data, on classical type Venturi tubes with piezo meter rings at inlet and throat
connections, is between 0.3 and 0.4% The coefficients of properly constructed and installed Venturi tubes of this
type should agree with the data.
within ±0.75% on any pipe Reynolds number down to 200,000 on 95% of the installations.
SPECIFICATIONS
VENTURI TUBE TYPE
- Fabricated flange type : FIG 1
- Fabricated weld-on type : FIG 2
- Machined flange type : FIG 3
- Rectangular type : FIG 4
FLANGE RATING
- ANSI 150, 300, 600, 900, 1500LB
MATERIAL
- Carbon Steel
- 304SS, 304L SS, 316SS, 316L SS
- Ni, Cr, Mo Alloy Steel(A182 F11 to 91)
PRESSURE LOSS% DEVELOPED DIFFERENTIAL
1
ANNULAR
VENTURI METER
ANNULAR VENTURI METER 2
1.0 / General
1.1 Introduction
The Annular venturi meter is a patented technology that accurately measures flow over a wide range of Reynolds
numbers, under all kinds of conditions and for a variety of fluids, It operates on the same physical principle as other
differential pressure-type flowmeters, using the theorem of conservation of energy in fluid flow through a pipe. The
Annular venturi meter remarkable performance characteristics, however, are the result of Its unique design, It
features a centrally-located cone inside the tube. The cone interacts with the fluid flow, reshaping the fluid’s velocity
profile and creating a region of lower pressure immediately downstream of itself. The pressure difference, exhibited
between the static line pressure and the low pressure created downstream of the cone, can be measured via two
pressure sensing taps, One tap is placed slightly upstream of the cone, the other is located in the downstream face of
the cone itself. The pressure difference can then be incorporated into a derivation of the Bernoulli equation to
determine the fluid flow rate. The cone’s central position in the line optimizes the velocity profile of the flow at the point
of measurement, assuring highly accurate, reliable flow measurement regardless of the condition of the flow upstream
of the meter.
This says that for a constant flow, the pressure in a pipe is inversely
pressure decreases as the velocity increases. For instance, as the High and Low Ports
Figure 1
fluid approaches the Annular venturi meter, it will have a pressureof
P1, As the fluid velocity increases at the constricted area of the Annular venturi meter, the pressure drops to P2, as
shown in figure 1. Both P1 and P2 are measured at the Annular venturi meter’s taps using a variety of differential
pressure transducers. The Dp created by Annular venturi meter will increase and decrease exponentially with the flow
velocity. As the constriction takes up more of the pipe cross-sectional area, more differential pressure will be created
at the same flowrates. The beta ratio equals the flow area at the largest cross section of the cone (converted to an
The Annular venturi meter is similar to other differential pressure (Dp) meters in the equations of flow that it uses.
Annular venturi meter geometry, however, is quite different from traditional Dp meters, The Annular venturi meter
This forces the flow in the center of the pipe to flow around the cone. This geometry presents many advantages over
the traditional concentric Dp meter. The actual shape of the cone has been continuously evaluated and tested for over
ANNULAR VENTURI METER 3
that line would be different. The velocity would be zero at the wall
of the pipe, maximum at the center of the pipe. and zero again at
Velocity Profile
the opposite wall. This is due to friction at the pipe walls that slows Figure 2
the pipe, it interacts directly with the “high velocity core” of the flow. The cone forces the high velocity core to mix with
the lower velocity flows closer to the pipe walls. Other Dp meters have centrally located openings and do not interact
This is an important advantage to the Annular venturi meter at lower flowrates. As the flowrate decreases, the
Annular venturi meter continues to interact with the highest velocity in the pipe. Other Dp meters may lose their useful
Dp signal at flows where the Annular venturi meter can still produce one.
The pipe flow profile in actual installations is rarely ideal. There are many insallations where a flowmeter exists in flow
that is not well developed. Practically any changes to the piping, such as elbows, valves, reductions, expansions,
pumps, and tees can disturb well-developed flow. Trying to measure disturbed flow can create a substantial problem
for other flowmeter technologies. The Annular venturi meter overcomes this by reshaping the velocity profile upstream
the cone, the flow profile “flattens” toward the shape of a well-developed profile.
The Annular venturi meter can flatten the flow profile under even conditions, such as single elbows or double elbows
out-of-plane positioned closely upstream of the meter. This means that as different flow profiles approach the cone,
there will always be a predictable flow profile at the cone. This ensures accurate measurements even in non-ideal
conditions.
ANNULAR VENTURI METER 4
2.0 / Features
2.1 High Accuracy
The Annular venturi meter primary element can be accurate to ±0.5% of reading. The level of accuracy is dependent
to a degree on application parameters and secondary instrumentation.
2.2 Repeatabity
The Annular venturi meter primary element exhibits excellent repeatability of +0.1% or better
2.3 Turndown
The turndown of the Annular venturi meter can reach far beyond traditional Dp meters. A typical turndown for a
Annular venturi meter is 10 to 1. Greater turndowns are attainable. Flows with Reynolds numbers as low as 8000 will
produce a linear signal. Lower Reynolds numer ranges are measurable and are repeatable by a curve fit to the
measured Dp.
Single Elbow and Annular Venturi Meter Double Elbow and Annular Venturi Meter
Figure 4 Figure 5
could disturb the Dp readings from the meter. The Annular venturi meter
forms very short vortices as the flow passes the cone.
These short vortices create a low amplitude, high frequency signal. This Singlnal Stability
translates into a signal with high stability from the Annular venturi meter. Figure 2
2.8 Sizing
The unique geometry of the Annular venturi meter allows for a wide range of beta ratios.
Standard beta ratios range from 0.45, 0.55, 0.65, 0.75, and 0.85.
2.10 Mixing
The short vortices described above mix the fluid thoroughly just downstream of the cone. The Annular venturi meter is
currently in many applications as a static mixer where instant and complete mixing are necessary.
(MODEL : DHAV-CC01)
FLANGE VERSION ▶
* FLUID NAME
PRESSURE (kpa)
(MODEL : DHAV-CC02)
A B D H C REMARKS
TOP PLATE sch. CON SIZE LINE SIZE 150# 300# ANSI RF
NPT
SIZE(mm) (mm) (mm) (mm) (mm) FLANGE
150 40 ~140 150~350 125 150 1/2
200 40 ~190 200~500 125 150 1/2
250 40 ~241 250~600 125 150 1/2
300 40 ~292 300~750 125 150 1/2
350 40 ~324 350~750 125 150 1/2
400 40 ~375 400~900 125 150 1/2
450 std ~425 450~1000 175 200 1/2
500 std ~476 500~1200 175 200 1/2
600 std ~578 600~1400 175 200 1/2
750 std ~730 750~1700 175 200 1/2
900 std ~883 900~2250 175 200 1/2
ANNULAR VENTURI METER 8
Ex : DHAV-CC01-100AYCM
WELDED TYPE
(Model : DHAV-CC02)
Ex : DHAV-CC02-0600AXDM
4-1
WEDGE METER
1. THE CHARACTERISTIC
DHWM-T
2. THEORY
3. CAPACITY
WEDGE METER
4. DIEMENSION
WN-RF TYPE
MODEL : DHOV-N
DESCRIPTION
The profile of the Venturi nozzle is axisymmetric. It
consists of a convergent section, with a rounded
profile, a cylindrical throat and a divergent. The
upstream face is identical with that of an ISA 1932
nozzle. The Throat consists of a part E of length
0.3d witch is the same as for the ISA 1932 nozzle
and a part E' of a length 0.4d to 0.45d
SPECIFICATIONS
VENTURI TUBE TYPE
- Threaded type : FIG 5
- Butt weld type : FIG 6
- Flanged type : FIG 7 Threaded
FIG 5
FLOW CALCULATION STANDARDS
- ISO5167, JIS Z 8762, ASME, KS A 0612
FLANGE RATING
Butt Weld
- ANSI 150, 300, 600, 900, 1500LB
FIG 6
NOMINAL PIPE SIZES AVAILABLE
- 0.5 to 120B(15A to 3000A)
MATERIAL
- Carbon Steel Flanged
- 304SS, 304L SS, 316SS, 316L SS
- Ni, Cr, Mo Alloy Steel(A182 F11 to 91)
FIG 7
�-2
1 2 3 4 5 6 7 8 9 10 11 12
0.20 10 (6) 14 (7) 34 (17) 5 16 (8) 18 (9) 12 (6) 4 (2)
0.25 10 (6) 14 (7) 34 (17) 5 16 (8) 18 (9) 12 (6) 4 (2)
0.30 10 (6) 16 (8) 34 (17) 5 16 (8) 18 (9) 12 (6) 5 (2,5)
0.35 12 (6) 16 (8) 36 (18) 5 16 (8) 18 (9) 12 (6) 5 (2,5)
0.40 14 (7) 18 (9) 36 (18) 5 16 (8) 20 (10) 12 (6) 6 (3)
0.45 14 (7) 18 (9) 38 (17) 5 17 (9) 20 (10) 12 (6) 6 (3)
0.50 14 (7) 20 (10) 40 (20) 6 (5) 18 (9) 22 (11) 12 (6) 30 (15) 5 (3) 20 (10) 6 (3)
0.55 16 (8) 22 (11) 44 (22) 8 (5) 20 (10) 24 (12) 14 (7) 6 (3)
0.60 18 (9) 26 (13) 48 (24) 9 (5) 22 (11) 26 (13) 14 (7) 7 (3,5)
0.65 22 (11) 32 (16) 54 (27) 11 (6) 25 (13) 28 (14) 16 (8) 7 (3,5)
0.70 28 (14) 36 (18) 62 (31) 14 (7) 30 (15) 32 (16) 20 (10) 7 (3,5)
0.75 36 (18) 42 (21) 70 (35) 22 (11) 38 (19) 36 (18) 24 (12) 8 (4)
0.80 46 (23) 50 (25) 80 (40) 30 (15) 54 (27) 44 (22) 30 (15) 8 (4)
*) The installation of thermometer pockets or wells will not alter the required minimum upstream straight lengths for the other fittings.
NOTES
1. The minimum straight lengths required are the lengths between various fittings located upstream or downstream of the primary device and the primary device itself.
All straight lengths shall be measured from the upstream face of the primary device.
2. Values without parentheses are "zero additional uncertainty" values (see 7.2.3).
3. Values I parentheses are "0.5% additional uncertainty" values (see 7.2.4).
VENTURI NOZZLE �-3
MODEL : DHOV-N
Nominal
Pipe ��� ------------------------------------------------ Pipe size in inch or mm
Size
4S ------------------------------------ 304SS
4L ------------------------------------ 304L SS
6S ------------------------------------ 316SS
6L ------------------------------------ 316L SS
Material
11 ------------------------------------ A182 F11
OP ------------------------------------ Option
3 ------------------ SW 1/2
4 ------------------ SW 3/4
Option /���
FLOW NOZZLE �-1
MODEL : DHON
DESCRIPTION
The Flow nozzles, more costly than other orifice due to
their structure, are suited for determining the flow rates
of fiuids flowing at high temperature and high pressure.
Under the same measuring conditions, a flow nozzle has
a higher mechanical strengh. can permit the flow of more
than 60 percent greater volume of a fluid, and can
measure the flow rates of fluids containing solid particles
less disturbed, than an orifice having the same bore.
Thus, they are suited, in addition, for highspeed flowing
fluids. We can supply not single flow nozzles, but also
flow nozzles having welded short pipes on both their
upstream and downstream sides.
SPECIFICATIONS
MOUNTING TYPE : ISO 5167 Long Radius MATERIAL
- Weld in type : FIG 1 - Carbon Steel
- Holding Ring type : FIG 2 - 304SS, 304L SS, 316SS, 316L SS
- Flange type : FIG 3 - Ni, Cr, Mo Alloy Steel(A182 F11 to 91)
MODEL : DHON
The flow nozzles are more expensive than orifice due to their structure, however, they are suitable for determining
the flow rates of fluids at high temperature and high pressure.
The flow nozzles can measure the flow rates of fluids containing a little amount of solid particles with les
inconvenience than orifices. under the same measuring conditions, the flow nozzle permits the flow rate of 60%
more than that of the same sized orifice, and also, it is suitable fo high velocity fluid because of a high mechanical
strength.
We can supply not only single flow nozzles, but also flow nozzle assembles having welded short pipes on both
upstream and down stream sides.
GENERAL MATERIAL
- Maximum Pressure : 30 kg/cm2G - Flow Conditioner : Aluminum, Carbon Steel 304(L)SS,
- Fluid : Gas 316(L)SS, etc
- Flow Rate : Range Table of Line size - Body : Carbon Steel, 304(L)SS, 316(L)SS
- Range Table of Line size (Air 760mmHgA, 20°C) Alloy Steel, etc.
Length(mm) - Sensor : 304(L)SS, 316(L)SS, Inconel,
Line Size Flow Range
Type
(Nm3/h)
A B Etoile Honey Comb Hastelloy, Alloy Steel, etc.
40 1 1/2 18~90 254 200
50 2 35~175 305 200
65 2 1/2 60~300 305 200
80 3 80~400 356 250
100 4 160~800 406 250
MOUNTING TYPE
125 5 250~1250 406 250
150 6 350~1700 559 250 - Body : Duct Flange, ASME(ANSI) Flange, etc.
200 8 600~2800 660 350
250 10 900~5000 711 350 - Sensor : Welded, Screw, Flange, etc
300 12 1600~7800 762 350
350 14 2000~9500 762 350
400 16 3000~14500 762 450
450 18 4000~19000 762 450 TRANSMITTER
500 20 5000~24000 914 450
550 22 5000~24000 914 450
600 24 6000~30000 1,220 600
- Connections : 2 Screw terminal block
650 26 7000~36000 1,220 600 - Output Signal : 4~20mADC(Limited at 30mADC)
700 28 8000~42000 1,220 600
750 30 9000~48000 1,220 600 - Loop Resistance : 0~1100Ω
800 32 10000~54000 1,220 600
850 34 11000~60000 1,520 600
900 36 12000~69000 1,520 600
950 38 13000~76000 1,520 600
1000 40 15000~85000 1,820 800
PERFORMANCE at 23�
C
1050 42 16000~94000 1,820 800
1100 44 18000~103000 1,820 800 - Zero Output : 4mA(Adjustable)
1200 48 21000~120000 1,820 800
1300 52 24000~145000 2,110 800
- Full Span Output : 20mA(Adjustable)
1400 56 29000~170000 2,110 1,000 - Operating Temperature : 0~400°C
1500 60 32000~190000 2,110 1,000
1600 64 37000~220000 2,530 1,000 100°C~over : (Fabricate Type)
1700~6000A *According to operation condition
※ SFM305Type Can use from above 600A
■ INSTALLATION INSTRUCTIONS
- Quantity : One - Quantity : Two
STEADY FLOW METER
Model : SFM300 Series
■ ASSEMBLY DRAWING
STEADY FLOW METER
■ ASSEMBLY DRAWING
■ ASSEMBLY DRAWING
PARSHALL FLUME
FLOW METER
Model : DHPF
www.dhinst.co.kr
PARSHALL FLUME FLOW METER �-2
Model : DHPF
1. 개 요
2. 종 류
3. 기 능
4. 특 징
PARSHALL FLUME FLOW METER �-3
Model : DHPF
5. 사 양
PARSHALL FLUME FLOW METER �-4
Model : DHPF
5. 사 양
Model : DHPF
8. 현장 설치 예
Model : DHPF
1I ------------------------------------------------ 1 Inch
2I ------------------------------------------------ 2 Inch
3I ------------------------------------------------ 3 Inch
6I ------------------------------------------------ 6 Inch
9I ------------------------------------------------ 9 Inch
1F ------------------------------------------------ 1 Feet
Nominal
Parshall Flume 1.5F ---------------------------------------------- 1.5 Feet
Size
3F ------------------------------------------------ 3 Feet
4F ------------------------------------------------ 4 Feet
5F ------------------------------------------------ 5 Feet
6F ------------------------------------------------ 6 Feet
7F ------------------------------------------------ 7 Feet
8F ------------------------------------------------ 8 Feet
CS -------------------------------- Carbon Steel
4S -------------------------------- 304SS
Parshall Flume Material 6S -------------------------------- 316SS
6L -------------------------------- 316L SS
FR -------------------------------- FRP
CS ----------------------- Carbon Steel
4S ----------------------- 304SS
� HOW TO ORDER
MODEL SUFFIX CODES DESCRIPTION
4B ------------------------------------------------------------------- 4
3B ------------------------------------------------------------------- 3
DHCP
2-1/2B -------------------------------------------------------------- 2.5
2B ------------------------------------------------------------------- 2
10 ------------------------------------------------ 01
20 ------------------------------------------------ 02
Pipe sch 40 ------------------------------------------------ 04
80 ------------------------------------------------ 08
160 ------------------------------------------------ 16
STPG ----------------------------- SG
STPT ------------------------------ ST
Material
304(L)SS ------------------------- 4(L)S
316(L)SS ------------------------- 6(L)S
PT1/2 -------------------- P1
PT3/4 -------------------- P3
Connection
NPT1/2 ------------------ N1
NPT3/4 ------------------ N3
S.W1/2 ------------------ S1
S.W3/4 ------------------ S3
Plug ------------ P
Plug & Vent Plug
Vent Plug ----- V
Option /���