Fuente Poder Adelsystem Flex9024a
Fuente Poder Adelsystem Flex9024a
Input Data
Nominal Input Voltage (2 x Vac) 115 – 230 Vac Norms and certifications
Manual select Input from 115 to 230 The CE mark in According to EMC 2004/108/EC and Low
Input Voltage range (Vac) 90 – 135 (115) voltage directive 2006/95/EC.
180 – 264 (230) Electrical Safety
Inrush Current (Vn and In Load) I2t 11 A 5 msec. In compliance to UL508.
Frequency 47 – 63 Hz 6% According to IEC/EN 60950 (VDE 0805) e EN 50178 (VDE
Input Current (115 – 230 Vac) 1.8 – 0.9 A 0160) for assembling device. The unit must be installed
Internal Fuse T4A according to IEC/EN 60950.Input / Output separation: SELV
External Fuse (recommended) 10 A (curve B) EN60950-1 and PELV EN 60204-1. Double or reinforced
Output Data insulation.
Output Voltage (Vn) Factory Setting 3% 24 Vdc EMC Immunity
Adjustment range (Vadj) 22 – 27 Vdc EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5,
Start up with Strong Load (capacitive load) 50.000F EN 61000-4-6, EN61000-6-2
Turn-On delay after applying mains voltage 1 sec. (max) EMC Emission:
Continuous Current at 24 V < 40°C (In) 5 A (permanent) EN61000-6-4, EN61000-3-2
Continuous Current at 24 V < 50°C (In) 4.5 A (permanent) Standards Conformity
Continuous Current at 24 V < 60°C (In) 4 A (permanent) EN 60204-1 Safety of Electrical Equipment Machines
Power Boost Current at 24 Vdc 60°C(In) In (60°C) x 1.5 3 min.
Current max. Overload 4Vdc (permanent) Imax=In60°Cx(1.8 - 2.2)
Current Short Circuit Icc
Max 2 sec.: Hiccup mode In (60°C) x 3
Permanent : Continuous Mode
Hold-up Time ( min. Vac) 24Vdc 5A Typ. 20 msec
Residual Ripple 80 mVpp
Efficiency 91 %
Over temperature Protection Yes. Shut-down output
and automatic restart.
Short-circuit protection 1° Hiccup Mode
2° Fold Back
3° Restart After Main
Dissipation power load max (W) 11
Over Load protection Yes
Over Voltage Output protection Yes (typ. 35 Vdc)
Parallel connection Yes
Power Good Contact rating (EN60947.4.1):
Max. DC1: 30 Vdc 1 A; AC1: 60 Vac 1A Resistive load
Min.1mA at 5 Vdc Min permissive load
Climatic Data
Ambient Temperature operation -25 up to +70 °C
(>60°derating 2.5% °C)
Ambient Temperature Storage -40 up to +85 °C
Humidity at 25 °C, no condensation 95 % to 25 °C
General Data
Isolation Voltage (In / Out) 3000 Vac
Isolation Voltage (In / PE) 1605 Vac
Isolation Voltage (Out / PE) 500 Vac
Protection Class (EN/IEC 60529) IP 20
Reliability: MTBF IEC 61709 > 500.000 h
Pollution Degree Environment 2
Connection Terminal Blocks Screw Type 2,5 mm
Protection class I with PE connected
Dimension (w-h-d) 55x110x105 mm
Weight 0.50 kg approx.