0% found this document useful (0 votes)
85 views5 pages

Ficha Tecnica Fibra Ducto SM 12-24F LSZH Antirroedor Maintronics GG

This document summarizes the specifications for Maintronics' duct cable for optical fiber. It includes 3 key points: 1. The cable has excellent optical and physical performance to meet customer needs. It uses a germanium-doped silica core and pure silica cladding fiber that meets ITU-T G652D standards. 2. The cable construction includes a FRP central member, loose buffer tubes stranded around it, and double layers of glass yarn for rat protection. An LSZH sheath provides fire retardant and water/moisture resistance. 3. The cable meets IEC standards and has a minimum 30-year lifetime. It withstands tensile loads up

Uploaded by

luis carreño
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
85 views5 pages

Ficha Tecnica Fibra Ducto SM 12-24F LSZH Antirroedor Maintronics GG

This document summarizes the specifications for Maintronics' duct cable for optical fiber. It includes 3 key points: 1. The cable has excellent optical and physical performance to meet customer needs. It uses a germanium-doped silica core and pure silica cladding fiber that meets ITU-T G652D standards. 2. The cable construction includes a FRP central member, loose buffer tubes stranded around it, and double layers of glass yarn for rat protection. An LSZH sheath provides fire retardant and water/moisture resistance. 3. The cable meets IEC standards and has a minimum 30-year lifetime. It withstands tensile loads up

Uploaded by

luis carreño
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

Maintronics - Duct Cable

1. General LSZH - Rat proof


This specification covers the design requirements and performance standard for the supply of optical fibre
cable in the industry. It also includes Maintronics premium designed cable with optical,
mechanical and geometrical characteristics.
Cable type Application
GYFTY68-12/24B1.3 Duct installation LSZH and rat proof protection
1.1 Cable Description
Maintronics cable has excellent optical transmission and physical performance, to meet customer requirements.

1.2 Quality
Maintronics ensures a stable quality control system for our cable products through several programs
including ISO 9001, ISO 14001 and OHS.

1.3 Reliability
Initial and periodic qualification tests for raw material and cable product are performed to assure the
cable’s performance and durability in the field environment.

1.4 Reference
ITU-T G.652 Characteristics of a single-mode optical fibre
IEC 60794-1-1 Optical fibre cables-part 1-1: Generic specification-General
Optical fibre cables-part 1-2: Generic specification-Basic optical cable test
IEC 60794-1-2
procedure
IEC 60794-3 Optical fibre cables-part 3: Sectional specification-Outdoor cables
Optical fibre cables-part 3-10: Outdoor cables-Family specification for duct and
IEC 60794-3-10
direct buried optical communication cables
Optical fibre cables-Part 3-11: Outdoor cables-Detailed specification for duct and
IEC 60794-3-11
directly buried single-mode optical fibre telecommunication cables

1.5 Life Time


Optical fibre cables supplied in compliance with this specifications is capable to withstand the typical
service condition for a period of 30 years without detriment to the operation characteristics of the cable.
Optical properties of the SM fibre are achieved through a germanium doped silica based core with a pure
silica cladding which meets ITU-T G652D, UV curable acrylate protective coating is applied over the
glass cladding to provide the necessary maximum fibre lifetime.
Geometrical, optical, and mechanical characteristics of fibre in cable as the following table:

Parameters Specification
MFD(1310nm) 9.2+/-0.4um
MFD(1550nm) 10.4+/-0.5um
Cladding diameter 125m1.0m
Fiber diameter 245+/-7um, with UV coating, and colored to : 250+/-15um
Core/cladding concentricity error ≤ 0.6um
Coating/cladding concentricity error ≤ 12.0um
Cladding non circularity ≤ 1.0%
Cut off wavelength λcc ≤1260nm
1310nm: 0.36dB/km max after cabling
Attenuation coefficient
1550nm: 0.22dB/km max after cabling
Bending-loss performance of optical fiber
≤0.05dB (100 turns around a mandrel of 50mm diameter)
@1310nm&1550nm
Polarization mode dispersion link value 0.1ps/km
Zero-dispersion wavelength 1312+/-12nm
Zero-dispersion slope ≤0.091ps/nm2.km

3. Optic Cable

3.1 General Design


FRP is applied as central strength member.
Loose tubes and fillers are SZ stranded around the central strength member. Rat-proof optical
fiber cable with double layers of glass yarn 600T with thickness of 0.3mm
Dry water blocking material and jelly is used in and over the cable core to prevent it from
water ingress. LSZH sheath is applied as outer sheath.

3.2 Construction

3.2.1 Cross Section of Cable


Type: GYFTY68-24B1.3-DUCT CABLE
Structure:

Details
FRP Diameter 1.8 mm
Losse tube Outer/Inner Dia. 1.6/1.0 mm
Optical fiber No. 24
Filler No. 2
Jelly
Filling compound
Water blocking tape Thickness 0.25 mm
MDPE inner sheath Thickness 0.8 mm
Layer1:Glass yarn(600T) Thickness 0.3 mm
Layer2:Glass yarn(600T) Thickness 0.3 mm
LSZH outer sheath Thickness 1.5 mm
Ripcord No. 2

Fiber: 24 x G.652D

Tube/Fibers 4/6
Color of Optical fiber Green,Yellow,White,Blue,Red,Violet
Color of buffer tube Green,Yellow,Natural,Natural

Overall diameter 11.3±0.1 mm


Weight 133 kg/km

Tech. Data Standard: IEC 60794


Features: Water blocking, Moistureproof, Crashing resistant, Tesile resistant
Allowalbe tensile strength 2500 N
short term 2200 N/10cm
Allowable crush strength
long term 1000 N/10cm
Minimum Bending Radius (Dynamic) 20 D
Minimum Bending Radius (Static) 10 D
Life Expectancy ≥30 Years
Temperature operating temperature range -20℃ ~ +70℃
Note: All dimension and datas are nominal value.
Rat-proof optical fiber cable with double layers of glass yarn 600T with thickness of 0.3mm
Fire retardant with outer sheath of LSZH and Water and moisture resistance with Cable Jelly, Filling compound and
Water blocking tape.

2019/12/3 Layer1:600T/15 Layer2:600T/16 BJJ


3.2.3 Main Mechanical and Environmental Performance of Cable

Fiber counts Tensile performance(N) Crush(N/100mm)


Short term Short term
1 / 24 2200 1000

Allowable Tensile Stregth 2500 N. Operation temperature: -40℃~+70℃

3.2.4 Color Code of the Fibre and Loose Tube and Filler

Each fibre and tubes can be identifiable throughout the length of the cable in accordance with the
following color sequence.
The color of the fillers will be natural.
1 2 3 4 5 6
Blue Orange Green Brown Grey White
color code
7 8 9 10 11 12
Red Black Yellow Violet Pink Aqua

3.3 Mechanical, Electrical and Environmental Test Characteristics


The mechanical and environmental performance of the cable are in accordance with the following table.
Unless otherwise specified, all attenuation measurements required in this section shall be performed at
1550nm.
Item Test Method Requirements
IEC 60794-1-2-E1
Load: According to 3.2.3 Additional attenuation after test: ≤0.1dB
Tension
Sample length: Not less than 50m. No damage to outer jacket and inner elements
Duration time: 1min.
IEC 60794-1-2-E3
Additional attenuation after test: ≤0.1dB
Crush Load: According to 3.2.3
No damage to outer jacket and inner elements
Duration of load: 1min
IEC 60794-1-2-E4
Radius: 300 mm
Additional attenuation: ≤0.1dB
Impact Impact energy: 10J
No damage to outer jacket and inner elements
Impact number: 1 times
Impact points: 3
IEC 60794-1-2-E11A
Mandrel radius: 12.5Dmm Additional attenuation: ≤0.1dB
Bend
Turns:10 No damage to outer jacket and inner elements
Cycles:5

IEC 60794-1-2-E6
Repeated Bending radius: 20Dmm Additional attenuation: ≤0.1dB
bending Cycles: 30 No damage to outer jacket and inner elements
Load: 150N

Torsion IEC 60794-1-2-E7 Additional attenuation: ≤0.1dB


Cycles:10 No damage to outer jacket and inner elements
Length under test: 1m
Turns: 90°
Load:150N
IEC 60794-1-2-F1
Sample length: at least 1000m
Temperature range:
Temperature The change in attenuation coefficient shall be
-40℃→+70℃
cycling less than 0.1 dB/km
Cycles:2
Temperature cycling test dwell
time: 12 hours
IEC 60794-1-2-F5B
Water Time : 24 hours
No water leakage.
Penetration Sample length : 3m
Water height : 1m
Other
According to IEC 60794 ,
parameters

4. Packaging and Drum


4.1 Cable Sheath Marking

Unless otherwise specified, the cable sheath marking shall be as follows:


Color: white
Contents: Maintronic, the year of manufacture, the type of cable, cable number, length
marking Interval: 1±0.2% m
Outer sheath marking legend can be changed according to user’s requests.
4.2 Reel Length
Standard reel length:14 km/reel, other length is also available.
4.3 Cable Drum
The cables are packed in steel drums.

You might also like