0% found this document useful (0 votes)
10 views

ABB Parameter

The document outlines the settings for various protection functions for three separate drives (SS7, SS8, SS60). These functions include parameters for operations, protections like stall, unbalance, earth fault, undervoltage/underfrequency, and start limits. The settings include whether the function is enabled, trip/alarm levels, delays, and reset modes.

Uploaded by

hafizhery.meb
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
10 views

ABB Parameter

The document outlines the settings for various protection functions for three separate drives (SS7, SS8, SS60). These functions include parameters for operations, protections like stall, unbalance, earth fault, undervoltage/underfrequency, and start limits. The settings include whether the function is enabled, trip/alarm levels, delays, and reset modes.

Uploaded by

hafizhery.meb
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

24VDC 240AC 240AC

Level 1 Level 2 Level 3 Level 4 Level 5 SS24 SS7 SS8 SS60 SS01
Operation Trip Reset
Alarm Acknowledge
Start1
Start2
Stop
Parameter Protection TOL Function ON ON ON
Disble During Start OFF OFF OFF
Reset mode9 L&R L&R L&R
Thermal mode9 STD STD STD
TOL bypass OFF OFF OFF
T6 15S 15S 15S
Cool coe 4 4 4
Te - - -
Ia/In - - -
Alarm level 90% 90% 90%
Trip level 100% 100% 100%
Reset level 40% 40% 40%
Ambient temperature9 40 deg 40 deg 40 deg
Stall Function ON ON ON
Reset mode L&R L&R L&R
Trip level 200% 200% 200%
Trip delay 1.0S 1.0S 1.0S
Phase failure Function OFF OFF OFF
Reset mode - - -
Alarm level - - -
Trip level - - -
Trip delay - - -
Unbalance Function ON ON ON
Reset mode L&R L&R L&R
Alarm level 85% 85% 85%
Trip level 70% 70% 70%
Trip delay 10S 10S 10S

Underload Function OFF OFF OFF


Reset mode - - -
Alarm level - - -
Trip level - - -
Trip delay - - -
Long stop Function - - -
Reset mode - - -
Alarm level - - -
Trip level - - -
Trip delay - - -
Earth fault Function ON ON ON
Enabled duration stop OFF OFF OFF
Reset mode L&R L&R L&R
Alarm level 0.1A 0.1A 0.5A
Trip level 0.1A 2.1A 1.0A
Trip delay O.2S O.1S O.2S
PTC Function OFF OFF OFF
Reset mode - - -
Trip level - - -
Trip delay - - -
Reset level - - -
SC Alarm level - - -
UV&AR Function ON ON ON
Reset Mode AUTO AUTO AUTO
Autorestart Function OFF OFF OFF
Mode - - -
MAT - - -
MPDT - - -
Delay - - -
Alarm level 80% 80% 80%
Trip level 75% 75% 75%
Trip delay 5.0S 5.0S 5.0S
Reset level 50% 50% 50%
Start limit Function OFF OFF OFF
Mode - - -
Interval - - -
Start number - - -
Long start Function OFF OFF OFF
Reset mode - - -
Rotor level - - -
Rotor delay - - -
Phase Sequence Function OFF OFF OFF
Reset Mode
Motor Control Starter type
Start time
Start time (N2)
Change over
Ramp up
Ramp down
Earth fault primary
Communication failure delay
Fail safe
Feedback
Feedback timeout
Soft test switch
External CT used
External CT1 primary
External CT2 primary
Parameter Control Motor Control External CT secondary
Control authority Profibus option Auto mode active
Soft local/ remote Soft local/ remote L hardwiring
R fieldbus

MD control MD control MD operator panel


MD in local
MD in remote
MD in auto Mode
MD in auto Mode
Grouping Function
Direction
Group number
Start delay
Start delay
Communication MODBUSRTU Address
Parity
Redundancy
Baud rate
PROFIBUSDPV Address
Mode
Block DP
Motor info Motor type
Voltage
Frequency
Rated power
In
In (N2)
DI Type
Function
DI0 ~DI12 (24VDC) or
Contact type
DI0-DI8 (110V or 240VAC)
Delay
Operation
DO DO Function
Delay
Principle
DO Function
Delay
Principle
Maintenance Running hour Function
Alarm level
Start number Function
Alarm Level