0% found this document useful (0 votes)
51 views1 page

A-301 Sections

This document provides instructions for interpreting architectural drawings. It states that all dimensions are in meters unless noted otherwise and must be verified on site. Drawings should not be scaled and written dimensions take precedence unless noted. Each drawing must be read together with all other relevant architectural, structural, mechanical and electrical drawings as well as general standard details, and any discrepancies brought to the engineer prior to work.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
51 views1 page

A-301 Sections

This document provides instructions for interpreting architectural drawings. It states that all dimensions are in meters unless noted otherwise and must be verified on site. Drawings should not be scaled and written dimensions take precedence unless noted. Each drawing must be read together with all other relevant architectural, structural, mechanical and electrical drawings as well as general standard details, and any discrepancies brought to the engineer prior to work.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

1.

ALL DIMENSIONS ARE IN METERS AND LEVELS IN METERS UNLESS NOTED


OTHERWISE. ALL DIMENSIONS TO BE VERIFIED ON SITE & APPROVED BY THE
ENGINEER.

2. DO NOT SCALE THE DRAWINGS. FOLLOW WRITTEN DIMENSIONS UNLESS


OTHERWISE NOTED.

3. EACH DRAWING SHALL BE READ IN CONJUNCTION WITH ALL OTHER


RELEVANT ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL
DRAWINGS & THE GENERAL STANDARD DETAILS. IN CASE OF ANY
DISCREPANCIES, BRING IT TO THE KNOWLEDGE OF ENGINEER & SAME TO BE
RESOLVED PRIOR TO EXECUTE OF WORK.
SETBACK SETBACK

PARAPET LVL.
+9.85 SSL

1.80

1.80
1.80

1.20

1.20
ROOF FLOOR LVL. ROOF ROOF
+8.05 SSL +8.05 SSL +8.05 SSL

0.15

0.15
0.60

0.60

0.30
0.32
F. C . F. C . F. C . F. C .

1.25

3.80

3.80
3.60

2.61

2.65
2.75

2.75
1.50
STORE PANTRY LOBBY LOBBY PANTRY STORE

1.10

1.10
9.85

FIRST FLOOR LVL. PLOT LIMIT PLOT LIMIT


+4.45 FFL +4.45 FFL +4.45 FFL +4.45 FFL +4.45 FFL

0.30 0.65

0.30 0.65
0.15

0.15
0.60
F. C . F. C .
4.00

2.96

3.00
2.40

2.40
GROUND FLOOR LVL. DINNING LIVING LIVING DINNING
+0.45 LVL PROPOSED CONCRETE
PAVING REFER SPECS.
PROPOSED CONCRETE
PAVING REFER SPECS.
+0.30 FFL +0.30 FFL
0.45

+0.00 LVL
0.30

0.30
SECTION - X,X
1
SCALE 1: 100 AS REVISED

1 03.08.2020 FINAL DESIGN SUBMISSION GS


SETBACK

Rev No. DATE DESCRIPTIONS BY


SETBACK
PARAPET LVL. CLIENT :
+9.85 SSL +9.85 LVL

+9.25 LVL ALI F R A ALRASHED


1.00
1.80

1.80

1.20
ROOF FLOOR LVL. ROOF
+8.05 SSL +8.05 SSL CONSULTANT :
1.65

PLOT LIMIT

0.80
0.15

GOLDEN SQUARE ENGINEERING

0.60
0.30

F. C .
+7.35 LVL CONSULTANTS
P.O. BOX : 126049, DUBAI, UAE
1.55

Phone : 04 3859882 Fax: 04 3859885


3.60

3.60

E_mail : [email protected]
BALCONY
2.20

4.75
PROJECT DESCRIPTION:
1.10

1.10
LOBBY 1.20
1.10
9.85

FIRST FLOOR LVL. PLOT LIMIT MASTER BEDROOM


+4.45 FFL +4.45 FFL +4.65 FFL G+1

0.65
+3.90 FFL ATTACHED 2 VILLAS
1.10

0.60

F. C . DUBAI - SAIH SHUAIB1


PLOT NO. 5138059
4.00

4.00

1.50
BUILDING TYPE :

3.45
G+1 VILLA
3.05
3.00

3.00

3.90
2.70
2.60
2.10

SHEET TITLE :

2.40

2.40
1.20
GROUND FLOOR LVL. PROPOSED CONCRETE LIVING ENTRY HALL
+0.45 LVL PAVING REFER SPECS. +0.45 LVL +0.45 FFL
+0.30 FFL
SECTIONS X-X , Y-Y
0.45

+0.00 LVL
0.30
0.30

0.25
DESIGNED : DRAWN :
ARCH. MOHANNAD ARCH. HALIM
CHECKED : DATE :

2 SECTION - Y,Y ARCH. TARIQ DECEMBER 2017


SCALE 1: 100 SCALE : SHEET SIZE PROJECT NO.:
1:100 A2 G1713
DRAWING NO. REVISION:
A-301 1
PURPOSE OF ISSUE :
FINAL DESIGN SUBMISSION

You might also like