The document contains 7 multiple choice questions about radiation therapy calculations including: 1) calculating the tissue maximum ratio (TMR) for a 100cm SAD PA field to deliver 100cGy at 8cm depth 2) calculating the TMR for a left axilla point at 8.4cm depth from a 23.5x23.5cm PA field 3) determining which calculation point would receive the most dose from combined AP and PA fields with no additional blocking

Uploaded by

api-691667702
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
40 views

Mantle Lab Questions

The document contains 7 multiple choice questions about radiation therapy calculations including: 1) calculating the tissue maximum ratio (TMR) for a 100cm SAD PA field to deliver 100cGy at 8cm depth 2) calculating the TMR for a left axilla point at 8.4cm depth from a 23.5x23.5cm PA field 3) determining which calculation point would receive the most dose from combined AP and PA fields with no additional blocking

Uploaded by

api-691667702
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Mantle Lab Questions

1. When calculating the MU of the PA field required to deliver 100 cGy, what would be the
TMR be? Given, the treatment parameters are 100 cm SAD, 23.5x23.5 cm2 , and a depth of 8 cm.
Please utilize the handout's attached data tables to answer this question. Round to the third
decimal place.

A. 0.855
B. 0.869
C. 0.864
D. 0.850

2. When trying to determine the dose to the Left Axilla calculation point, what would the TMR
be for the PA field calculation? Given, the treatment parameters are 100 cm SAD, 23.5x23.5
cm2, and a depth of 8.4 cm. Please utilize the handout's attached data tables to answer this
question. Round to the third decimal place.

A. 0.844
B. 0.888
C. 0.861
D. 0.854

3. Which calculation point do you expect to be receive the most dose from both the AP and PA
fields combined? Assume no additional blocking is added throughout the treatment.

A. Rt Supraclav
B. Left Neck
C. Mid-Mediastinum
D. Isocenter
4. What would be the distance from CAX to the Rt Supraclav calculation point? Round the
final answer to the first decimal place.

A. 11.3 cm
B. 12.2 cm
C. 10.2 cm
D. 7.8 cm

5. What would the off-axis ratio (OAR) be for the Rt Supraclav point when using a 6MV
photon beam? Round to the third decimal point.

A. 1.033
B. 1.024
C. 1.038
D. 1.016

6. What would be the dose to the Rt Supraclav point using a 6MV photon beam?

A. 246 cGy
B. 239 cGy
C. 218 cGy
D. 225 cGy

7. Calculate the dose from the 6MV AP beam to a right lung calculation point which is placed 9
cm lateral to the CAX. The depth and SSD are 6 cm and 94 cm SSD. The block is 5 half value
layers thick. Round the the nearest cGy.

A. 4.0 cGy
B. 109 cGy
C. 25.0 cGy
D. 112 cGy