Solenoide Apagado Motor Diagrama Electrico rp2309b

The document describes Murphy Push/Pull DC solenoids that provide single unit versatility for engine applications like shutdown. It offers two models in two voltages that provide different stroke lengths and holding forces. An optional time delay solenoid drive can be used to reduce coil burnout by limiting energization time. Dimensions, typical wiring diagrams, installation and operation instructions are provided.

Uploaded by

wladyco2018
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
174 views4 pages

Solenoide Apagado Motor Diagrama Electrico rp2309b

The document describes Murphy Push/Pull DC solenoids that provide single unit versatility for engine applications like shutdown. It offers two models in two voltages that provide different stroke lengths and holding forces. An optional time delay solenoid drive can be used to reduce coil burnout by limiting energization time. Dimensions, typical wiring diagrams, installation and operation instructions are provided.

Uploaded by

wladyco2018
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

sect.

40 00092 / 00-02-0107
rev. 2016/07/05

Pull/Push DC Solenoids for Diesel Engines


RP Series
The Murphy Push/Pull DC Solenoids provide single
unit versatility for engine applications, such as
shutdown. One solenoid offers pull/push operation.
The RP Series has no internal switches, reduces coil
burnout and reduces adjustments while boosting
reliability. The solenoid offers high force in its small size.
It can be used with most engines’ start systems.
A choice of two models and two voltages is available. RP2309B & RP2310B
All models come complete with return spring and
rubber seal boot.
An SD85 Solenoid Drive Time Delay is also available to
greatly reduce possibility of coil burnout and to facilitate
low current-piloted operation.

Basic Models
RP2307B & RP2308B
Models RP2307B and RP2308B give a full 1 in. (25
mm) stroke at 11 pounds (49 N) and hold up to 27
pounds (120 N) at full voltage, continuous duty. They SD85 Solenoid Drive Time Delay
will operate at any stroke less than maximum; see chart
below. The SD85 is used when the solenoid is duty cycled
Models RP2309B and RP2310B can pull 17 pounds for short time periods such as two-position throttle
(75 N) with a 1-1/2 in. (38 mm) stroke. They hold up to operation. It also provides enhanced operational
35 pounds (155 N) at full voltage, continuous duty. See control for normal on-off applications. Using the SD85
chart below for holding force at any stroke less than ensures the energize coil is only powered for one to
maximum. two seconds with each operation. If the plunger does
not seat in that time, it is highly unlikely it will seat. The
SD85 activates both coils of the solenoid for a short
time then de-energizes the Energize coil. The Hold-in
coil is energized as long as the signal to the SD85 is
active. This ensures long life of the RP solenoid.
Input voltage: 8 to 30 VDC. See chart below for current
ratings.

Watts Power/Cold Force in Pounds at 100% Voltage/Inches Stroke

Force* in Pounds [Kilograms] at 100% Voltage†


Solenoid Max Power in Watts Stroke in Inches (Millimeters)
Model Stroke Hold Energize Hold
Number In. (mm) Coil Coil Continuous 1/8 (3) 1/4 (6) 1/2 (13) 3/4 (19) 1 (25) 1-1/4 (32) 1-1/2 (38)
25 [11.34] 22 [9.98] 21 [9.53] 17 [7.71] 14 [6.35] 10 [4.54] _____ _____
RP2307B 1 (25) 18 624
<13> [5.90] <12> [5.44] <11> [4.99] <10> [4.54] <8> [3.63] <6> [2.72] _____ _____
27 [12.25] 25 [11.34] 23 [10.43] 19 [8.62] 15 [6.80] 11 [4.99] _____ _____
RP2308B 1 (25) 12 696
<15> [6.80] <14> [6.35] <13> [5.90] <12> [5.44] <9> [4.08] <7> [3.18] _____ _____
32 [14.52] 30 [13.61] 27 [12.25] 22 [9.98] 18 [8.16] 13 [5.90] 8 [3.63] 6 [2.72]
RP2309B 1-1/2 (38) 18 1029
<19> [8.62] <18> [8.16] <16> [7.26] <14> [6.35] <11> [4.99] <9> [4.08] <6> [2.72] <4> [1.81]
35 [15.88] 34 [15.42] 31 [14.06] 26 [11.79] 22 [9.98] 17 [7.71] 12 [5.44] 7 [3.18]
RP2310B 1-1/2 (38) 12 960
<20> [9.07] <19> [8.62] <17> [7.71] <15> [6.80] <12> [5.44] <9> [4.08] <7> [3.18] <4> [1.81]

* Forces shown are without return spring. Forces shown < > are with return spring. Forces shown in [ ] are in kilograms.
† To determine the operating current, divide the power (watts) indicated in the above table by the applied voltage. Solenoids will operate at any stroke less
than maximum.
In order to consistently bring you the highest quality, full-featured products, we reserve the right to change our specifications and designs at any time. MURPHY products and the Murphy
logo are registered and/or common law trademarks of Enovation Controls, LLC. This document, including textual matter and illustrations, is copyright protected by Enovation Controls, LLC,
with all rights reserved. (c) 2015 Enovation Controls, LLC. A copy of the warranty may be viewed or printed by going to http://fwmurphy.com/warranty.
Dimensions

RP2307B & RP2308B

RP2309B & RP2310B

NOTES: SD85
1. Typical operating temperature for single 15 second operation
of the energize coil is less than:
140° F (60° C) ± 10° F (6° C) for 1 in. (25 mm) Stroke Sole-
noids (70° F/21° C rise above ambient)
120° F (49° C) ± 10° F (6° C) 1-1/2 in. (38 mm) Stroke Sole-
noids (50° F/10° C rise above ambient)
See CAUTION statement in Operations section on pre-
vious page and note maximum housing temperature is
185° F (85° C).
2. The energize coil should not be activated for more than 15
seconds. Longer energize coil activation times will damage the
solenoid.
3. Allow minimum 15 minutes for cooling between activations
of energize coil to avoid damaging the solenoid. (Depends on
length of time energize coil is energized.) Contact Enovation
Controls for high cycle rate applications.
4. The energize coil must fully seat the plunger to allow the hold-
coil to function properly.
Typical Wiring Diagrams

NOTE: In either application if the starter hangs on starters


CAUTION: On certain starter solenoids/
with integral solenoids, the energize coil remains energized.
contactor relays, current can feed back
through the energize terminal from the
hold coil and provide a parallel path to
ground through the device connected to
the energize terminal.

Typical time-delayed
shutdown using a 518PH
magnetic switch
(SD85 is optional)

Typical time-delayed
shutdown using a 760A
magnetic switch
(SD85 is optional)

Mechanical Installation Operation


1. Bolt the solenoid securely to the mounting bracket. The solenoid coil is connected to the existing engine
2. Connect linkage and check for binding. Plunger starter system or an equivalent circuit. A SD85 is
should move freely throughout the complete stroke recommended. At starting, both the Energize and Hold-
and be allowed to bottom at the internal stop of the in coils are energized. In the run mode, the Hold-in coil
solenoid. is continuously energized while the Energize coil has to
DO NOT MOUNT WITH BOOT DOWN. DO NOT be disconnected, reducing the heating effect and power
APPLY ANY GREASE OR LUBRICATION TO PARTS. consumption and avoiding damage to the device.
IMPORTANT: If the plunger does not seat, it will NOTE: Coils that burn out due to improper electrical
release prematurely when shifted to the holding mode hookup, misadjustment or improper operation are not
of operation. Re-adjust linkage to lengthen the plunger covered by Murphy factory warranty.
stroke. Adjust the yoke in increments of 1/2 turn until
plunger will remain in hold position. CAUTION: The solenoid housing is hot to the
touch. A temperature rise to 185° F (85° C) is
Electrical Installation permissible.
1. Refer to the diagrams above for typical electric NOTE: A cool down period of 15 minutes minimum
wiring. should be allowed between energized pull in cycles.
2. Use minimum 10 AWG [65/0.3 mm (4.5 mm)] wire
* Always provide proper circuit protection
size, as noted in the wiring diagrams. A smaller wire will
with fuses or circuit breakers.
reduce the current available and thus the pulling force.
Wire length must be kept to a minimum.
How to Order

Part Number Model and Description Notes


RP2307B — 12VDC, 1 in. (25 mm) stroke, 10 lbf
40700092
(44 N) pull, 25 lbf (111 N) hold
RP2308B — 24VDC, 1 in. (25 mm) stroke, 11 lbf
40700093
(49 N) pull, 27 lbf (120 N) hold
DC Solenoids
RP2309B — 12VDC, 1-1/2 in. (38 mm) stroke, 13 lbf
40700094
(58 N) pull, 32 lbf (151 N) hold
RP2310B — 24VDC, 1-1/2 in. (38 mm) stroke, 17 lbf
40700095
(75 N) pull, 35 lbf (155 N) hold
40700067 SD85 Solenoid Drive Time Delay

65010108 Clevis yoke assembly

65010110 Clevis yoke chain assembly

40050315 Threaded rod (1-1/2 in.)

00002457 RPS in-line ball joint

00002458 RPS 90° ball joint

Shipping Weights:
RP2307B: 24oz. (0.7 kg) Clevis yoke: 1 oz. (.03 kg)
RP2308B: 24 oz. (0.7 kg) Clevis yoke chain assembly: 2 oz. (.04kg)
RP2309B: 48 oz. (1.4 kg) Threaded rob (1-1/2 in.): .05 oz. (.001 kg)
RP2310B: 48 oz. (1.4 kg) RPS in-line ball joint: .05 oz. (.001 kg)
SD85: 6.4 oz. (0.2 kg) RPS 90° ball joint: 1 oz. (.03 kg)