This document provides the guaranteed technical particulars for a turbine equipment consisting of two horizontal 2 jet Pelton turbines each with a design output of 7,500 kW and an operating net head of 435 meters. Key specifications of the turbine include a design discharge of 2.01 cubic meters per second, maximum discharge of 2.32 cubic meters per second, minimum discharge of 1.01 cubic meters per second, and an efficiency of 90.04% at design output. The turbine is to be directly mounted to the generator shaft and will have 20 runner buckets made of stainless steel with a pitch circle diameter of 1400 mm.

Uploaded by

parthdhar10
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
21 views

Turbine Efficiency Data Annexure - 3

This document provides the guaranteed technical particulars for a turbine equipment consisting of two horizontal 2 jet Pelton turbines each with a design output of 7,500 kW and an operating net head of 435 meters. Key specifications of the turbine include a design discharge of 2.01 cubic meters per second, maximum discharge of 2.32 cubic meters per second, minimum discharge of 1.01 cubic meters per second, and an efficiency of 90.04% at design output. The turbine is to be directly mounted to the generator shaft and will have 20 runner buckets made of stainless steel with a pitch circle diameter of 1400 mm.

Uploaded by

parthdhar10
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

BOVING FOURESS LIMITED Page no.

1 of 10
OM POWER HEP (2 x 7500 kW) + 15% COL
H2JP
Guaranteed technical particulars

SCHEDULE -1

GUARANTEED & TECHNICAL


PARTICULARLARS FOR TURBINE
EQUIPMENT

1 / 10
BOVING FOURESS LIMITED Page no. 2 of 10
OM POWER HEP (2 x 7500 kW) + 15% COL
H2JP
Guaranteed technical particulars

GUARANTEED & TECHNICAL PARTICULARS FOR TG EQUIPMENT

S. Item Description Unit Specification


No.

TURBINE & AUXILIARIES

1. Name of Manufacturer & place of Boving Fouress Limited


manufacturing and country Bangalore, India.
2. a) Type of turbine : Horizontal 2 Jet Pelton
b) Model of Turbine : PR8E 350.02 25/5
c) Design net head of turbine m : 435
d) Design discharge of turbine at Rated M3/s : 2.01
net head of 435 m.
e) Maximum allowable discharge of M3/s : 2.32
turbine at Rated net head of 435 m.
f) Minimum allowable discharge of M3/s : 1.01
turbine at Rated net head of 435 m.
g) Design discharge of turbine at M3/s : 1.98
Maximum net head of 440 m.
h) Maximum allowable discharge of M3/s : 2.28
turbine at Maximum net head of 440
m.
j) Minimum allowable discharge of M3/s : 1.00
turbine at maximum net head of 440
m.
k) Minimum head where turbine can be m :
operated.
l) Maximum head where the turbine can m :
be operated.
m) Operating net head range m : 435
n) Center line of runner EL : Please refer S.A. drawing enclosed
(m)
3. a) Design output of turbine at Design net kW : 7732
head and Design discharge
b) Maximum output of turbine at Design kW : 8891.75
head and maximum discharge that
machine can pass through.
c) Minimum output of turbine at min. kW : 3865.98
head and minimum discharge where
turbine can operate continuous.
d) Output of turbine at operating net kW : 7731.96
head & Design Discharge
4. Efficiency:
Guaranteed efficiency at Design net
head for the following percentages
of Design outputs.
a) 115% % ; 90.00
b) 100% % : 90.04
c) 75% % : 89.50
d) 50% % : 89.70

2 / 10
BOVING FOURESS LIMITED Page no. 3 of 10
OM POWER HEP (2 x 7500 kW) + 15% COL
H2JP
Guaranteed technical particulars

5. Discharge : M3/s
Turbine discharge at Design net head
for the following percentages of
outputs:
a) 115% % : 2.32
b) 100% % : 2.01
c) 75% % : 1.50
d) 50% % : 1.00
6. Characteristic and performance Yes : Yes
curves for turbine enclosed. No
7. Speed:
a) Specific speed in MKS units : 19.8 Per Jet
b) Design speed of turbine RPM 600
c) Designed maximum runaway speed : 1085
in rpm on cam / off cam at Design RPM
head and maximum head (rpm) and
max. discharge.
d) Maximum speed rise when Design % : 55
load throw off.
e) Maximum pressure rise at Design % : 20
load throw off (%).
f) Duration up to which the machine can Min. : 15
withstand designed maximum
runaway speed without aux. systems
in operation
g) Discharge during runaway condition M3/s : 2.32
h) Calculated Lowest critical speed of : 1300 rpm
shaft system.
i) Direction of rotation when viewed : Anticlockwise
from driving end.
j) Total weight of rotating parts of Ton : 2.75 (Approx)
Turbine s
8. Regulation
a) Momentary rise in speed on suddenly 55%
reducing load to zero from full Design
load as percentage of Design speed.
b) Time of Deflector closing for Secs : 1.5
regulation in item 7 above
c) Time of Nozzle opening for full Secs : 2
opening
d) Time of Nozzle closing for regulation Secs : 2
in item 7 above
e) Time of Deflector opening for full Secs : 10
opening
f) Minimum oil Pressure required for bar : 70
opening and closing of deflector and
Nozzle.
g) Flywheel effect of generating unit for : 20 T-m²
the regulation stated above
9. Factor of safety
a) Guaranteed Minimum factor of safety : 1.5
under worst conditions based on yield
point of the material.
b) Name and location of the part having : Runner
the factor of safety in (a) above

3 / 10
BOVING FOURESS LIMITED Page no. 4 of 10
OM POWER HEP (2 x 7500 kW) + 15% COL
H2JP
Guaranteed technical particulars

10. a) Please state whether proposed : Based on model test report


turbine is based on existing model
test report OR based on CFD
solutions. Please enclose details
for scrutiny.
b) Prototype Hill chart or performance Yes : Yes
characteristics of turbine for / No
various heads enclosed

11. Runner :

a) Material composition of Runner : Stainless Steel (13/4 Cr-Ni)


b) Applicable standards for material : ASTM A 743 CA6NM
c) No. of runner buckets : 20
d) Runner pitch circle diameter mm : 1400
e) Weight of finished runner Kg : 2550 (Approx)
f) Sources of runner casting : Reputed foundries
n) Hydraulic load of each bucket KN : 169
i) Method of connection of runner with Flanged coupling
Generator shaft extension.
j) Estimated Needle opening and Sec. : 20
closing time
k) Method of sealing needle and : Chevron Seal
servomotor
l) Minimum oil pressure required for : 70 bar
operation of needle
o) Diameter of needle servomotor mm : 160
p) Stroke Length mm : 125
q) Type of deflector control : Hyd. Servomotor
r) Material of servomotor body and : As per manufacturer standard
piston
s) Torque of servomotor (Needle) Kg-m : 1760
t) Control Oil pressure bar : 70-100
u) Location of Prop. distributing valve : On hydraulic power pack
v) Bore/ Stroke of servomotor mm : 160 / 125
w) Is servomotor capable of operation in Yes/ : Yes
manual mode of control. No
x) Make & Type of needle position : Reputed make / LVTD
transmitter
y) Output signal of transmitter mA : 20mA
z) Aux. supply voltage of transmitter V : 24 V

12. Shaft: Not Applicable (since runner is


directly mounted on generator shaft)
a) Material and composition : -
b) Construction (forged or tubular) : -
c) Applicable standards for:
i) material : -
ii) forging :
d) Type of connection between turbine -
shaft and generator shaft
f) Hardware for connecting turbine shaft : -
to runner.
g) Turbine manufacturer shall take Yes : Yes
responsibility for interface engg No

4 / 10
BOVING FOURESS LIMITED Page no. 5 of 10
OM POWER HEP (2 x 7500 kW) + 15% COL
H2JP
Guaranteed technical particulars

between turbine & generator


13. Turbine guide bearing Not Applicable ( since runner is
directly mounted on generator shaft
& covered in generator)
a) location : -
b) Type of material : -
c) Applicable standards of materials : -
d) Bearing designed to operate at hour : -
maximum load for (hours) s
e) Maximum runway speed in RPM the RPM :
bearing can withstand for min. 10
minutes.
f) Maximum duration of the above : D.C. motor will be supplied to supply
runaway speed the bearing can oil.
withstand without external oil supply
g) Whether bearing can withstand : With cooling water On.
runaway with lubricating cooling
water on ore without cooling water on
14
Shaft gland
a) Type : Stuffing box
b) Lubrication arrangement : Water
c) Cooling arrangement: :
i) Medium of Lubrication Water
ii) Quantity LPM -
iii) Pressure Kg/Sq.-cm NA
iv) Flow monitoring device NA
v) Pressure monitoring device NA

15. Setting
a) Elevation of center line of runner EL : Refer S.A. drawing enclosed
b) Critical sigma : NA
c) Recommended plant sigma : NA

16. Brakes : Covered in generator

a) Location and no. of brakes : -


b) Type of brake and liner : -
c) Speed at which brakes are to be rpm : -
applied
d) Means of operation : -
e) Time taken for machine to come to Sec -
standstill from the instant of s.
application of brakes
f) Are limit switches provided at the Yes/ -
brake? No
17. Oil pump and OPU Tank and oil
pressure accumulator:
a) Number of OPU for each turbine : One
Material and Thickness of oil tank mm Mild Steel-As per manufacturer
sheet standard
b) No. off oil pumps for each OPU : Two
c) Type of oil pump : AC driven pump
d) Impeller material of pump : As per manufacturer standard.

5 / 10
BOVING FOURESS LIMITED Page no. 6 of 10
OM POWER HEP (2 x 7500 kW) + 15% COL
H2JP
Guaranteed technical particulars

e) Body material of pump : - Do -


f) Pump to be run continuously or : Intermittent
intermittently
g) No. and type and size of each -
accumulators
h) No. and size of nitrogen accumulators 4 x 55 Ltrs
i) Motor rating kW : Will furnished during detail
engineering.
j) Dimensions of OPU tank (LxBxH) cm : - Do -
l) Oil pressure
 Design pressure 70 bar
 Min pressure 40 bar
 Test pressure 110 bar
m) Grade of oil : ISO VG 68
n) Effective volume of sump tank : Will be furnished during detail
engineering.
o) Total volume of oil required for initial : - Do -
filling
p) Size and type of directional control : - Do -
valves for Deflector, Nozzle and
Brake jet in any.
q) Number of Deflector Open / Close :
operations possible, when pump is
stopped.
 Open operations -
 Close operations One
r) Number of Needle open/close :
operations possible, when pump is
stopped
 Open operations One
 Close operations One
s) Are Internal / external pipings, fittings, : Yes
clamps, connectors, embedded parts,
first fill of oil including spare,
circulating oil (oil Cooling) pump is
included in scope

18. Cooling Water System:


a) Source of cooling water : Penstock Tapping
b) No. of pumps for each unit : Not Applicable
c) Rating of each pump HP : - Do -
d) Material of pump impeller : - Do -
e) Material of pump body : - Do -
f) Rating of each motor kW : - Do -
g) Material and size of strainer element : Stainless steel / 100 micron
h) Pressure switch range : 2 – 40 bar
i) Flow switch range : Will furnished later

19. Digital Governor PLC based electronic type


a) Make and type of digital governor Allen Bradely/Schneider/Reputed
b) No of Processors one
c) Functional distribution of processors
d) No. of bits in processing word 8 bits

6 / 10
BOVING FOURESS LIMITED Page no. 7 of 10
OM POWER HEP (2 x 7500 kW) + 15% COL
H2JP
Guaranteed technical particulars

e) Speed in MHz
f) Internal Memory
 RAM 16 KB
 ROM
g) External Memory 2 MB Flash card
 RAM (Type & size)
 ROM (Type & size)
h) Whether watchdog feature for Yes
software, hardware is provided?
i) Real time and calendar clock
available?
j) Number of I/o modules Input 96 DI, and Output 32 DO
k) Input multiplication relays-type & Auxiliaries relays
quantity
l) Digital input excitation voltage &
current
m) Out put relays-type & quantity Auxiliaries relays
o) Type of signals for analog input (RTD, 4 to 20 Milli Amps
T/C, 4-20ma etc.)
p) Network communication modules : Ethernet TCPIP protocol
 Nos.
 Type
 Protocol
q) Electromagnetic interference Yes/ Yes
compatibility & Standard No
r) Total no. of type of modules
 Power supply modules : One
 Control processor : One
 DC-DC converter : One
 Digital Input / Output Modules : 5+2
 Analog Input / Output modules : 1+1
 Speed sensing modules : Nil

20. After detail design


Proportional valves with
connectors
a) Make and Type :
b) Guide vane
 Size :
 Flow rating LPM :
 Operational signal mA/V :
:
c) Runner Blade
 Size :
 Flow rating LPM :
 Operational signal mA/V :

21.
Speed Sensors with connectors
a) Type and Make : Proximity switch, P & F Equipment
b) No. of channels : one
c) Output signal type : Pulse load

7 / 10
BOVING FOURESS LIMITED Page no. 8 of 10
OM POWER HEP (2 x 7500 kW) + 15% COL
H2JP
Guaranteed technical particulars

d) No of speed switches : one


e) Frequency operational range KHz : 3 Khz

8 / 10
BOVING FOURESS LIMITED Page no. 9 of 10
OM POWER HEP (2 x 7500 kW) + 15% COL
H2JP
Guaranteed technical particulars

22.
Speed Monitor
a) Type & Make : P & F Equipment
b) Type of sensor : Proximity switch
c) Frequency operational range kHz : 3 K hz
d) Aux. voltage V : 24 V
e) No. of speed contacts : two

23. P& F Equipment


Speed Sensing Device
a) Type & Make :
b) Thickness of plate :
c) No of holes/ Teeth :
d) Type of mounting :
e) Type of bracket from speed sensing :

24.
Surge Shaft Water Level Sensor
a) Type & Make : Ultra sonic , P& F Reputed
b) Measuring Range Mtrs : 0-6 M
c) No. of sensors provided : one
d) Type of output signal : 4-20 Milli Amps
e) Universal amplifier Yes/ : -
No
f) Aux. voltage V : 24 V
g) Type of bracket from speed sensing L- Clamp
25.
Governor Performance Data

a) Speed dead band Hz :


b) Range of speed measurement % :
c) Resolution of speed measurement % :
d) Governor dead time Sec. :
e) Permanent speed droop % : 0 to 10%
f) Speed changer adjustment % :
g) Software Modes of operation Yes/
Provided by governor No
 Speed control :
 Manual :
 Surge shaft Water Level control :
 KW Control
 Optimum Control :
 Any other feature :
h) Opening gate limiter adjustment :
i) Opening gate limiter time setting :
j) Temporary speed droop : 0 to 100%
k) Sensitivity of governor % : 1%
l) Range of adjustment of opening and % : 1 to 99 sec
closing time
m) Whether capable of automatic load Yes/ :
and frequency control No
n) Min. time for full load acceptance Sec :

9 / 10
BOVING FOURESS LIMITED Page no. 10 of
10
OM POWER HEP (2 x 7500 kW) + 15% COL
H2JP
Guaranteed technical particulars

o) Whether control unit can Yes/ :


communicate with plant supervisory No
system
p) Is software available for Yes/ :
programming, trouble shooting No
q) Is supervisory system provided Yes/
No
r) Is GSM alarm messaging system Yes/
provided No
s) Is remote operation provided Yes/
No
26.
Weights and Measures

a) Heaviest package for shipment


 Name : Generator Rotor
 Weight Kg : 34 Tons
 Dimension LxBxH mtrs : After detail design

b) Heaviest assembly to be lifted by


powerhouse crane
 Name : Generator
Kg
 Weight : 40 Tons
mtrs
 Dimension LxBxH : After detailed design

c) Recommended capacity of Ton : 45/10T


powerhouse crane s

10 / 10