0% found this document useful (0 votes)
809 views8 pages

Frimec Packaged Units Catalogue-2022

This document provides specifications for FRIMEC air-cooled rooftop packaged air conditioner models PRC-C200 through PRC-C900MEA. The models vary in cooling capacity from 24 kW to 100 kW and use R407C refrigerant. Key specifications include dimensions, weights, component details like compressors and fans, cooling and power capacities, sound levels, and protection devices. Performance is rated based on outdoor air temperatures of 35°C and 46°C dry bulb.

Uploaded by

walid.saab2
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
809 views8 pages

Frimec Packaged Units Catalogue-2022

This document provides specifications for FRIMEC air-cooled rooftop packaged air conditioner models PRC-C200 through PRC-C900MEA. The models vary in cooling capacity from 24 kW to 100 kW and use R407C refrigerant. Key specifications include dimensions, weights, component details like compressors and fans, cooling and power capacities, sound levels, and protection devices. Performance is rated based on outdoor air temperatures of 35°C and 46°C dry bulb.

Uploaded by

walid.saab2
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

AIR COOLED ROOFTOP PACKAGED AIR CONDITIONERS

Models: PRC-C200,250,300,400MEA
PRC-C500,600,900MEA

Direct Expansion Products


Air-Cooled
MODEL-DESIGNATION BREAKDOWN

P R C C 2 0 0 M E A 1
Series symbol
Service Reference
Self-contained type
(rooftop type) Design sequence
Compressor
Series symbol horse power Series symbol
200= 8Hp E=3-phase
250=10Hp 380V,400V,415V,50Hz,4 wires
300=12Hp
Refrigerant Design sequence
C : R407C 400=15Hp
500=20Hp
600=24Hp
900=32Hp

-1-
FRIMEC
International
SPECIFICATIONS
Model name
Power supply PRC-C200~C900MEA : 3N~ 400-415V 50Hz
kW 24.0 32.0 35.0 48.0 64.0 70.0 100.0
Outdoor
35˚CDB Btu/h 81,900 109,200 119,500 163,800 218,400 238,900 341,200
Total
cooling kcal/h 20,700 27,600 30,100 41,300 55,100 60,200 86,000
capacity *1 kW 21.9 30.8 33.0 43.7 61.5 66.0 94.0
Outdoor
46˚CDB Btu/h 74,800 105,100 112,600 149,200 209,900 225,200 320,800
kcal/h 18,900 26,500 28,400 37,600 52,900 56,800 80,900
Sensible kW 19.2 25.6 28.0 38.4 51.2 56.0 80.0
Outdoor
cooling Btu/h 65,600 87,400 95,600 131,100 174,700 191,100 273,000
35˚CDB
capacity *1 kcal/h 16,600 22,100 24,100 33,100 44,100 48, 200 68 ,800
Total power input *2 kW 8.1 10.5 12.5 15.6 20.8 25.5 39.8
Power factor % 84 86 86 86 83 83 83
Capacity step % 0-100 0 - 5 0- 1 00 0 - 6 6 -1 0 0
Refrigerant R407C
Refrigerant charge kg 4. 0 5.9 5.7 2 x4 . 5 2 x 5 .9 2 x5 . 7 3 x6 . 3
Refrigerant control Capillary tube
External finish Acrylic resin coating
Color MUNSELL 5Y8/1
Height mm 1 ,00 0 1 ,2 00 1 ,65 0
Dimension Width mm 1 ,30 0 1 ,9 90 2 ,10 0
Depth mm 1 ,53 0 1 ,6 70 2,10 0
Net weight kg 3 60 390 395 6 55 75 5 76 5 1, 10 0
Compressor Hermetic line start (Scroll Compressor)
No. x Motor output kW 1x 5 . 5 1x7.5 1x8.0 2x 5 . 5 2 x7 . 5 2 x 8 .0 3 x 8 .0
Evaporator Cross fin coil
Evaporator fan Centrifugal - direct-drive
Evaporator fan motor Three - phase squirrel cage induction motor( - connection)
No. x Motor output kW 1x0.7 1x1.25 1x1.25 1x1.7 1x2.5 1x2.5 1x4.5
CMM 80 100 100 160 200 200 285
Evaporator fan airflow CFM 2,826 3,532 3,532 5,651 7,064 7,064 10,066
L/S 1,333 1,667 1,667 2,667 3,333 3,333 4,750
mmAq 10 20 25
Pa 100 200 250
Condenser Cross fin coil
Condenser fan Propeller - direct drive
Condenser fan motor Three phase cage induction motor
CMM 160 180 320 360 480
CFM 5,651 6,354 11,302 12,708 16,954
L/S 2,667 3,000 5,333 6,000 8,000
Drain connection mm 25.4
Sound pressure level dB(A) 66 69 70 73 76
High pressure switch, Fuse
Protection devices Low pressure switch (only for PRC-C900MEA)
Over current relay (compressor)
Internal thermostat (compressor,Outdoor&Indoor fan motor)

Note 1.Cooling capacity is based on the following conditions.


Indoor;27 CDB,19 CWB
2.Total power input based on 400V-3Ph-50Hz at nominal condition.
3.Refrigerant charge volumes are factory charged.
4.Capacity is gross capacity which do not include a deduction for evaporator fan motor heat.
5.The measurning point of the Sound pressure level is 1m from the unit surface.
6.The range of working voltage is within 10% voltage of power supply.
7.Specification subject to change without notice.