Struc
Struc
1. Structural drawings are to be read in conjunction with other related drawings including existing drawings, 1. a) All concrete shall conform to the requirements of CAN/CSA. A23.1. Cement shall be Type GU 1. Reinforcing shall be new billet steel conforming to the following standards: 1. All structural steel work shall conform to CAN/CSA S16. 1. Masonry is designed in accordance with CAN/CSA S304.1.
for dimensions, elevations, roof and floor slopes and presence of openings, inserts, and existing Portland Cement unless noted otherwise. Normal weight concrete for various purposes shall be
underground services and mechanical/electrical elements. Do not scale off of the drawings or as follows: a) 10M and larger CSA G30.18 400 MPa 2. All structural steel material shall conform to CSA G40.20/G40.21 with the following grades: 2. Masonry construction shall conform to CAN3-A371. Refer to Field Review and Testing section for
electronic/computer files, written dimensions always take precedent. Hard copy drawings are the official b) Weldable reinforcement CSA G30.18 400W MPa (welding to CSA W186) testing requirements.
documents for the project and always take precedent over electronic/computer files. c) Welded wire mesh CSA G30.5 a) Rolled and HSS shapes 350W (G40.21)
MIN. 28 DAY MAX. MAX. SIZE EXPOSURE d) Epoxy coated reinforcement ASTM A775 b) Plates and bars 300W 3. Concrete masonry units shall conform to CSA A165. Compressive strength for concrete masonry shall
2. Prior to commencement of work, the Contractor shall compare all related drawings; confirm all dimensions STRENGTH SLUMP AGGREGATE CLASSIFICATION c) Bolts ASTM A325 be 20 MPa (3000 psi) at 28 days with f'm = 12 MPa (1750 psi). Masonry Contractor shall provide to the
and field measure/confirm all existing conditions. Report any discrepancies to the Architect and Engineer ELEMENTS MPa(psi) mm.(inch) mm.(inch) Note: 1) Weldable reinforcement (including deformed bar anchors) must be clearly identified on each d) Anchor bolts and miscellaneous hardware ASTM A307 Engineer written confirmation of unit strengths prior to installation.
of Record ("Engineer" henceforth). piece. e) Reinforcing bars welded to structural steel 400W (to CSA G30.18)
Foundations and Footings 25 (3600) 75 (3") 20 (3/4") - 2) Reinforcement in concrete shear walls and frame members with force modification factors Rd greater f) A53 pipe 240W 4. Use only Type 'S' mortar to CSA A179. No calcium chloride in any form is permitted in the grout
3. If discrepancies relating to structural work are found in the various documents, the more stringent than 2.0 shall be weldable grade in conformance with CSA Standard G30.18. g) Stainless steel 304 or mortar mixes.
provisions shall apply, unless approved by the Engineer. Specifications shall control over these Walls 30 (4350) 75 (3") 20 (3/4") F2
drawings and General Notes only where the specifications provide for more stringent requirements. 2. Reinforcement shall have concrete protection as follows, unless noted otherwise: 3. All welding shall conform to CSA W59 and to be performed by welders under CSA W47.1, 5. Masonry Contractor must discuss all masonry construction with the Engineer prior to commencing work.
Columns 30 (4350) 75 (3") 20 (3/4") F2
Contractor, suppliers and subtrades are to ensure that they are working with the 'Issued for fabricators to CWB approval. Welds shall be E-70xx. Nelson stud welding shall meet specifications
Construction' drawings. Suspended slabs and beams 30 (4350) 75 (3") 20 (3/4") - Fire Resistance Rating of the manufacturer and shall be tested by a qualified testing agency. Refer to "Field Review and 6. Masonry reinforcing shall conform to the following standard:
0-2 hrs. 3 hrs. Testing" for all weld testing requirements.
4. Bracing of the structure and all components during construction, including any underpinning, shall a) Cold-drawn steel wire - G30.3
remain the sole responsibility of the Contractor. Arch. concrete (see Arch.) a) All surfaces placed in contact with ground 75mm (3") 75mm (3") 4. Control heat/pace of weld when welding steel adjacent to other materials (wood, concrete, etc.) to b) Welded steel wire fabric - G30.5
b) Formed surfaces exposed to ground or weather 50mm (2") 50mm (2") prevent cracking, spalling or burning of adjacent material. c) Deformed steel wire - G30.14
5. These drawings show requirements for completed structure only. The design and inspection of Exterior 30 (4350) 75 (3") 20 (3/4") F2 c) Walls 32mm (1 1/4") 32mm (1 1/4") d) Steel bar reinforcing - CSA-G30.18
falsework, shoring and reshoring is the responsibility of the Contractor and shall conform to WCB d) Column ties - interior 40mm (1 1/2") 50mm (2") 5. Unless otherwise noted, apply one shop coat of primer to all steel work, to CISC/CPMA 1-73A
Interior 30 (4350) 75 (3") 20 (3/4") -
standards. e) Column ties - exterior 50mm (2") 50mm (2") Primer for exterior exposure shall be zinc-chromate Type 1, conforming to CGSB1-GP-40d. 7. Lap splices to be as follows, unless otherwise noted.
f) Slabs 25mm (1") 40mm (1 1/2")
6. All shop drawing reviews by the Engineer constitute review for general concepts only; the detailed Slabs on grade g) Slab bands and Beams 40mm (1 1/2") 50mm (2") 6. All steel work exposed to weather shall be hot dipped galvanized unless noted otherwise on the Wire reinforcing 200mm (8")
design remains the responsibility of Contractor/Fabricator. All components shall be assembled and h) Parking slab - top 40mm (1 1/2") 40mm (1 1/2") Structural or Architectural drawings. Hot dip galvanize all steel connectors (including fasteners) of 10M 450mm (18")
Exterior 32 (4650) 75 (3") 20 (3/4") C2 - bottom 25mm (1") 40mm (1 1/2") wood members where exposure to rain during or after construction may cause rusting/staining of 15M 650mm (26")
erected in accordance with final reviewed shop and erection drawings. No fabrication/erection shall
proceed until review has been completed by the Engineer. i) Slab on grade (from top of slab) 40mm (1 1/2") ---- wood exposed to view, unless noted otherwise. 20M 900mm (36")
Interior 32 (4650) 75 (3") 20 (3/4") -
j) Other, unless otherwise noted 40mm (1 1/2") 40mm (1 1/2") 25M 1300mm (51")
7. Design Loads: Topping concrete 32 (4650) 100 (4") 10 (3/8") - 7. Where required, all hot dip galvanizing shall conform to CAN/CSA G164.
3. All reinforcing bars and stud rails shall be accurately placed, chaired and tied securely to prevent 8. Unless otherwise noted, provide 1-15M vertical full height at:
Masonry Grout 20 (3000) 200 (8") 10 (3/8") - displacement and to maintain the specified cover. Install column reinforcement accurately with templates. 8. Apply 2 coats of Galvcon paint protection to hot dipped galvanized surfaces damaged by a) Ends of walls
a) Specified uniform loads Live Load Superimposed Provide CSA standard hooked dowels from bottom of footing to match and lap with verticals. Install masonry transportation, erection or site welding. b) Corners and intersections
(u.n.o. on plan) Dead loads dowels accurately to align with center of walls. Chairs shall be protected against rusting where required for c) Each side of doors, other openings and control joints
appearance. Do not wet dowel reinforcement unless approved by the Engineer. 9. Unless noted otherwise, design structural steel connections for minimum half the shear or d) 800mm (32") o.c. for structural masonry wall,
Roof Snow load based on: Ss= 3.2 kPa 0.45 kPa b) Slumps listed are before the addition of super plasticizers. Tolerance in specified slump shall be
compression capacity of the members connected (design by the Fabricator's Engineer). Bolted 1200mm (48") o.c. for non-load bearing masonry partition.
Importance = 1.25 Post-disaster Sr= 0.2 kPa ± 20 mm (3/4"). 4. Site bending of bars is not permitted without prior approval of Engineer. connections shall consist of a minimum 2-19mmØ (3/4"Ø) A325 bolts with 9mm (3/8") connector plate,
unless noted otherwise. 9. Provide hooked dowels from bottom of concrete base to match vertical masonry wall reinforcing. The
c) No calcium chloride is permitted in any form in the concrete mixes. 5. Provide epoxy coated rebars where noted on plan in accordance with CAN/CSA S413 (Parking Structures).
Main Floor (4.8 kPa L.L. includes partitions) 0.4 kPa Contractor and Masonry Contractor shall ensure that dowels are centered accurately with cells over.
Chair bars with plastic chairs and tie with plastic coated wire. 10. Submit 4 sets of shop drawings for the above to the Engineer for review prior to fabrication. Shop
d) Submit mix designs to the Engineer and testing agency for review and approval prior to placement.
Lower floor 4.8 kPa 0.4 kPa drawings shall show all details, and indicate all applicable design loads and material specifications and 10. All bars must be continuous, properly lapped at splices. At corners and intersections, horizontal
Mix design submittals shall identify the elements for which they are intended. 6. Minimum reinforcement shall be as follows unless otherwise noted: shall include an erection layout for all members. When member design forces are shown on plan or reinforcement shall be bent and lapped.
Mechanical Room 4.8 kPa 0.4 kPa e) Fly ash replacement (where noted) is the mass of fly ash as a percentage of the total mass of details, shop drawings shall be submitted and sealed by a Professional Engineer registered in the province
a) Wall reinforcement:
cementing material. of B.C. Do not proceed with fabrication until shop drawings have been approved by the Engineer. They 11. Unless noted otherwise, horizontal reinforcement in regular block masonry shall consist of:
Stairs, Corridors and Storage 4.8 kPa 0.4 kPa
150mm (6") wall - 10M @ 300 (12") VERT., 10M @ 300 (12") HOR., CENTERED shall be designed by Specialty Structural Engineers, registered in the province of British Columbia and
2. Perform all works in accordance with CAN/CSA A23.1, including the following: RETAINED BY THE CONTRACTOR, who will seal all related shop drawings, review the components and a) 9 ga. ladder type joint reinforcement at 400mm (16") on center, lap 200mm (8").
Superimposed dead loads are non-structural dead loads including architectural topping, partitions (for 200mm (8") wall - 15M @ 450 (18") VERT., 15M @ 450 (18") HOR., CENTERED b)
their attachments in the field and provide all required sealed letters (Schedule S-B & S-C) to the Engineer. 2-15M above and below openings less than 2400mm (8'-0") wide; extend bars 600mm (24") past edges
LL<4.8 kPa) roofing material, pavers, ceiling finishes and mechanical/electrical conduits/fixtures. a) Construction Tolerances 250mm (10") wall - 10M @ 400 (16") VERT., EACH FACE STAGGERED of openings. (See also requirements for lintels).
b) Fabrication and placement of reinforcing 10M @ 400 (16") HOR., EACH FACE STAGGERED c) 1-15M continuous in each of two grouted bond beams at 2400mm (8'-0") on center and at top of wall.
c) Placement of concrete, including proper vibration and curing. 11. The Professional Engineer sealing the Fabricators shop drawing is also responsible for all field review
b) Seismic and Wind 300mm (12") wall - 10M @ 300 (12") VERT., EACH FACE STAGGERED of their work and shall provide a letter to the Engineer confirming that the work has been completed in 12. Where H block masonry is specified on the drawings or specifications, horizontal reinforcing shall consist
3. Take all precautions to ensure exposed concrete achieves finish desired by the Architect, including 10M @ 300 (12") HOR., EACH FACE STAGGERED accordance with the final reviewed steel shop drawings and all structural requirements. of the following (unless noted otherwise):
Seismic load based on: Seismic Data Importance = 1.5 Post-disaster
proper forming, mix design, site care and adequate vibration. Protect against damage during stripping 2-15M verts full height at ends of all walls unless noted otherwise
Sa (0.2) Sa (0.5) Sa (1.0) Sa (2.0) PGA 12. All fabrication and welding exposed to view to be appearance quality to the Architect's satisfaction. a) 9 ga. ladder type joint reinforcement at 400mm (16") on center, lap 200mm (8").
and entire construction period.
b) 1-15M continuous at 1200mm (4'-0") on center and at top of wall.
0.301 0.194 0.108 0.063 0.145 b) Slab reinforcing (or temperature reinforcing) 13. See Architectural drawings for miscellaneous steel components. Any steel components not shown on the
Site Class D 4. See Architectural drawings for slab elevations, drainage, slopes and locations of reglets, reveals and chamfers. c) 2-15M above and below openings as in regular block masonry.
Fa = 1.28 Fv = 1.39 100mm (4") 10M @ 500 (20") o.c. EACH WAY Structural drawings are considered to be Secondary components (see notes on Secondary components and
Rd = 1.5 Ro = 1.3 Unless noted otherwise, exposed corners of slabs, beams, slab bands, columns and walls shall be 125mm (5") 10M @ 400 (16") o.c. EACH WAY their attachments). Assume 6mm (1/4") thickness, u.n.o. 13. Cells to be grouted shall be kept clear of mortar and conduits or other materials unless approved by the Engineer.
150mm (6") or less 10M @ 300 (12") o.c. EACH WAY
beveled 20mm x 20mm (3/4"x3/4"). 14. Provide cap plates at open ends of HSS tubes (seal weld all around). Provide drain hole at base of
Wind load based on q 1/50 = 0.44 kPa 175mm (7") 15M @ 500 (20") o.c. EACH WAY 14. Fill cells containing reinforcement and inserts with concrete as per the "Concrete Notes" section.
190mm to 215mm (7 1/2" to 8 1/2") 15M @ 450 (18") o.c. EACH WAY HSS tubes.
Importance = 1.25 Post-disaster 5. Blockouts, nailers, conduits, ducts, pipes, sleeves and other openings are subject to approval by the Engineer. Vibrate concrete completely in filled cells.
225mm to 250mm (9" to 10") 15M @ 400 (16") o.c. EACH WAY
15. Unless noted otherwise, welds shall be 6mm fillet welds.
a) Openings and conduits are not permitted in wall zones, within 990 mm (39") of wall ends and 275mm to 300mm (11" to 12") 15M @ 350 (14") o.c. EACH WAY 15. Unless approved by the Engineer, fill cells in 1200mm (4'-0") high lifts or, if clean-outs are provided, in
8. These drawings show structural work required to meet provisions of Part 4 (and Part 9 where intersections and columns. Concrete topping (ie: over steel deck) 152x152 MW 9.1 x MW 9.1 welded wire mesh 16. Welding of reinforcing to embedded plates is permitted only with weldable deformed bar anchors with 2400mm (8'-0") high lifts.
applicable) of the NBCC 2010. the following fillet weld sizes:
c) Footing reinforcement:
b) Where permitted, space openings 2 diameters, or minimum 150 mm (6") apart. 16. Provide lintels over all openings or recesses, including those for mechanical or electrical service equipment.
9. Design of Secondary component items including their attachment to the structure is the responsibility 2-15M continuous plus hooked dowels of same size and spacing as wall vertical reinforcing. 10M (3/8")Ø 6mm (1/4")
Unless noted otherwise, lintels less than 1200mm (4'-0") span shall be 200mm (8") deep, and lintels over
of others. 15M (5/8")Ø 10mm (3/8")
c) Single openings larger than 300 mm (12") or a group of openings occupying together more than 300x300 mm d) Other locations not identified above: 15M @ 400 (16") 1200mm (4'-0") span and less than 2400mm (8'-0") span shall be 400mm (16") deep. See notes 11 and 12
20M (3/4")Ø 12mm (1/2")
10. All codes and documents referred to in these General Notes are to be the current adopted edition. (1.0 sq. ft.) in any 1 sq. meter (10 sq. ft.) area shall not be permitted without the approval of the Engineer. above for reinforcing requirements.
7. All bars shall be continuous, properly lapped at splices. At corners and intersections; horizontal 17. Grout fill all voids on underside of all base plates and bearing plates in contact with concrete or masonry
11. Supply of Record Drawings is outside the scope of services. reinforcement shall be bent and lapped. with a plastic consistency non-shrink grout with a minimum 7 day strength of 45 MPa (6500 psi). Follow 17. Unless noted otherwise, where control joints are noted, terminate 50% of all horizontal reinforcement (wires and bars)
6. Expansion and/or construction sequence joints shall be installed in concrete structures greater than on each side of the joint. Unless noted otherwise, provide vertical wall control joints at maximum 15m (50'-0") o.c.
manufacturer's specifications and instructions for mixing and placement.
45m (150 ft.) in length, details and locations shall be discussed with and approved by the Engineer in 8. Unless noted otherwise, lap lengths, including dowels, for 400 MPa (58 ksi) reinforcement shall be and 7.5m (24'-6") from corners. Locations shall be approved by the Engineer and Architect.
FIELD REVIEW AND TESTING writing prior to construction. as follows: 18. If the structural steel member size specified on the structural drawings is not available then the
Epoxy coated bars 18. In non-load bearing partitions, provide 50mm (2") min. clearance to all concrete columns and 25mm (1")
Contractor shall notify the Engineer immediately and allow for the next available size up.
1. The Contractor is solely responsible to give the Engineer reasonable advance notice of when structural 7. Stripping of forms for structural elements is not allowed until concrete strength has reached 50% of the 28 day 10M - 400mm (16") 10M - 500mm (20") clearance to slab over. Fill gap with compressible fire rated material where required. Provide dowels in
work is ready for reviews by the Engineer (min. 24 hours prior to pour or concealment). Contractor is compressive strength for columns and walls, 70% of the 28 day compressive strength for slabs and beams and 75% of 15M - 600mm (24") 15M - 750mm (30") concrete base at bottom of wall and lateral restraint at top of wall as per structural detail.
the compressive strength for slab and beams in parking structures (use % of 56 day compressive strength if fly ash 19. All embed plates with headed stud anchors to be fillet welded, unless approved by the Engineer (ie: fusion
responsible for reviewing their own work and the work of their subtrades prior to review by the Engineer. 20M - 750mm (30") 20M - 980mm (39")
content in concrete mix exceeds 25% replacement). Strength of concrete shall be determined from field-cured cylinders. machine welds not permitted). Fillet weld sizes to be similar to note 16 u.n.o. 19. Unless noted otherwise, expansion anchors are not allowed in masonry. All drilled in anchors shall be the
25M - 1170mm (46") 25M - 1530mm (60")
2. All structural work requires written review by the Engineer, including: See note 6 of 'Suspended Concrete Slabs/Slab Bands and Beams' for additional requirements. 30M - 1400mm (55") 30M - 1840mm (72") epoxy type. Use Hilti Hit HY150 MAX in solid or grouted masonry and Hilti Hit HY20 (complete with sleeve)
20. Contractor is responsible for the cost of any member upsizing due to availability of sizes/grades specified. in hollow masonry.
a) Concrete Reinforcement 8. All hot and cold weather concrete work shall be carried out in accordance with CAN/CSA A23.1.
b) Masonry Reinforcement (including non-load bearing partitions) 20. Interlock courses at all wall corners and intersections.
c) Structural Steel (including decking) a) When temperature is expected to fall between 3°C and -10°C within 3 days of pouring concrete, a) Lap splices not shown on drawings shall not be allowed unless approved in writing by the Engineer.
STEEL DECKING
d) Wood framing (including sheathing) the Contractor shall carry out one or more of the following procedures: 21. Hot and cold weather construction shall be in accordance with CAN/CSA A371.
9. Unless noted otherwise, openings in walls and slabs shall have 2-15M extra each side extending 600mm 1. Steel roof decking and floor decking shall be as per plan. Roof decking shall conform to CSSBI 10M;
i) Make provisions to heat mix water or aggregate to maintain a minimum concrete (2'-0") past corners, plus 2-15M x 1200mm (4'-0") diagonal each corner. floor decking shall conform to CSSBI 12M. Interior decking shall have a minimum zinc coating of
3. Material testing shall be directed by the Engineer at the expense of the Owner.
temperature of 10°C. ZF75 to CSSBI 101. Exterior decking shall have a minimum zinc coating of Z275 to the same STEEL STUDS
10. Welding of reinforcing to embedded plates is permitted only with weldable deformed bar anchors with standard. Unless noted otherwise on the drawings, provide 76mm deep (3") roof deck type RD306
4. Concrete testing shall be in accordance with CAN/CSA A23.2 and carried out by an independent
ii) Make provisions to heat the form work or soil surface. Concrete shall not be poured against the following fillet weld sizes: and floor deck type HB938 by VicWest or approved equal. Place sheets in minimum 3 span lengths, 1. Light gauge stud assemblies including connections to supporting structural elements shall be designed by
testing agency approved by the Engineer. Unless permitted by the Engineer, a minimum of 3 test
any surface with a temperature less than 3°C (Calcium chloride or other de-icing salts are 10M (3/8")Ø - 6mm (1/4") unless noted otherwise on the drawings. a Professional Engineer retained by the Contractor in accordance with Part 4 of the B.C. Building Code,
cylinders shall be cast for each 50 cu. meter/50 cu. yards or each day's pour, whichever is less.
not permitted). 15M (5/8")Ø - 10mm (3/8") and CAN/CSA-S136.
Test one at 7 days and two at 28 days (with two additional at 56 days when concrete mix exceeds 2. Unless noted otherwise, as a minimum, fasten deck to supports and perimeter elements with Hilti
25% flyash replacement). Submit written reports for review by the Engineer. Test reports shall 20M (3/4")Ø - 12mm (1/2")
iii) Cover concrete with insulation blanket for the first 36 hours after pouring concrete. Do not Direct fasteners (X-EDN19 THQ12, X-ENP-19 L15, X-EDNK22 THQ12 as applicable) @150mm o.c. 2. Steel studs, joists and tracks to be as manufactured by Bailey Metal Products Ltd or equal,
identify the locations where concrete is being tested with gridlines and elevations. longitudinal & @ 610/5 pattern transverse. Screw side lap with Hilti #10 screws (SLC) @ 300mm o.c. 20 Ga. (0.91mm) minimum, unless specified otherwise.
pour when temperature is expected to fall below -10°C within 3 days after pouring. 11. Provide contingency reinforcing additional to all other requirements, with "add" and "delete" unit prices
included in bid. Include reinforcing required for non-structural concrete and masonry shown on the maximum. Refer to manufacturer's installation requirements and recommendations. Use button punch
5. Submit concrete test results max. 24 hours after test.
iv) Make provisions for a heated enclosure to maintain the temperature of all concrete surfaces various drawings. @300 for composite concrete decks. 3. Follow good construction practices for installation, including use of bridging and details as recommended
above 10°C for a minimum of 3 days after the pour. by the manufacturer.
6. The Owner shall appoint an independent CSA certified testing agency to carry out representative 3. Repair damaged deck coating with Galvacon paint.
12. Reinforcing not indicated on the structural drawings needed for mechanical/electrical support (i.e. radiant
testing of bolt torque and welding on structural steel work, including decking. This testing shall take v) Provide alternate mix designs for cold weather. 4. Fasten with #12 sheet metal screws and to concrete with Hilti type DN direct fasteners or equal unless
piping, conduit, etc) is the responsibility of the contractor.
place prior to concealment of all structural steel. 4. Unless noted otherwise, reinforce all roof deck openings greater than 150mm (6") square and less than specified otherwise.
b) When the temperature is expected to rise above 25°C the Contractor shall: 400mm (18") square with L38x38x5 (L1 1/2"x1 1/2"x3/16") extended and puddle welded to minimum
7. All structural steel welds shall be tested by a qualified testing agency to the following criteria (u.n.o.): SUSPENDED CONCRETE SLABS / SLAB BANDS AND BEAMS two flutes on each side of opening. Frame larger openings with L75x75x6 (L3"x3"x1/4") extending to 5. For non-load bearing steel stud assemblies, allow for minimum span/360 deflection of roof or floor structure over.
i) Make provisions to cool concrete to maintain a max. temperature of 30°C. main structural members or as shown on the drawings.
a) Ultra sonic test 100% of all shop and field complete penetration (CP) welds. 1. See also concrete and reinforcing notes. 6. Provide 4 sets of sealed shop drawings and submit for review prior to fabrication. All shop drawings shall
b) Magnetic particle test 15% of all field fillet welds. ii) Make provisions to prevent concrete from drying. 5. Unless noted otherwise, reinforce all floor deck openings greater than 150mm (6") square and less than show all details and indicate all applicable design loads and material specifications.
c) Visual inspection of 100% of all shop and field welds. 2. Embedded conduits and pipes 400mm (18") square with 3-10M, 4-sides of opening, extend bars 200mm (8") min. past edge of opening, plus
9. Take measures to minimize shrinkage cracking including covering and dampening concrete in the curing stage. 1-10M x 600mm (24") at each corner. Frame larger openings with L100x100x6 (L4"x4"x1/4") extending to 7. Following erection, the same Professional Engineer shall inspect installation of all light gauge stud assemblies
8. Additional testing and field review resulting from rejection of more than 5% of work will be at the a) Embedded conduits (ducts and pipes) are subject to approval by the Engineer, submit layout to the main structural members or as shown on drawing.
Contractor's expense. and submit a sealed letter stating that installation of same meets all design requirements.
10. Unless otherwise noted, provide 3.2mm wide x T/4 deep(1/8" x T/4) deep control joints in two directions Engineer for review.
in grade slabs centered on column lines, and maximum at 4500mm (15 ft.) o.c. (T = slab thickness) 6. Unless noted otherwise, provide L100x100x6 (L4"x4"x1/4") frame under all roof top mechanical units.
b) Do not place embedded conduits or pipes within 300mm (12") of columns or walls and do not place 8. Design and detailing of the above items and their attachments are not the responsibility of the Engineer.
FOUNDATIONS embedded ducts within 600mm (24") of columns and walls.
Contractor shall be responsible to coordinate the number and locations of mechanical units with the They shall be designed by Specialty Structural Engineers, registered in the province of British Columbia
11. Unless otherwise noted, where expansion anchors are required, use Hilti KB 3 or approved equal. Mechanical Consultant. and RETAINED BY THE CONTRACTOR, who will seal all related shop drawings, review the components
1. Design of foundation is based on the soils report of Sept 9 2011, by GeoPacific Consultants with an allowable Where chemical anchors are required, use Hilti HIT HY150 MAX epoxy, or approved equal. and their attachments in the field and provide all required sealed letters (Schedule S-B & S-C) to the
c) Maximum conduit size in one layer shall be 1/4 slab thickness and maximum total size of conduits 7. Unless noted otherwise, provide L75x75x6 (L3"x3"x1/4") continuous at perimeter of all steel deck floors
bearing pressure of 75 kPa for spread footings. All footings shall bear on soil capable of this pressure without Engineer.
crossing shall be 1/3 slab thickness. and roofs.
failure or undue settlement. If native soil or fill are found during construction to have a lower allowable bearing
pressure, notify the Engineer, and provide revised foundation to the Engineer's specifications. PRECAST CONCRETE
d) Separate parallel conduits minimum 3 times the larger diameter, center to center, with a minimum 8. Shop drawings for decking (4 sets) shall be submitted for review prior to fabrication and are to be
1. Refer also to Concrete and Reinforcing notes. clear distances of 50mm (2"). sealed by a Professional Engineer registered in B.C. Shop drawings shall show all details and indicate
SECONDARY COMPONENTS AND THEIR ATTACHMENTS
2. Follow all recommendations given in soils report for preloading, backfill, drainage, sub-base preparation
and other requirements. all applicable design loads and material specifications. Design of deck to be verified by Fabricator's 1. Secondary components include but are not limited to the following:
2. Precast Manufacturer shall be responsible for the design, detail and delivery of all precast units to site. e) Maximum in slab ducts shall be 50mm in a 175mm (2" in 7") slab, clear distance between ducts shall engineer for loads and spans shown on the drawings. Provide temporary shoring to composite decking
be minimum 600mm (24") and minimum distance to walls and columns shall be 900mm (36"). (Refer to all contract documents for secondary components)
3. Contractor is solely responsible to ensure that Geotechnical Engineer reviews and confirms allowable as necessary. Any deck capacities and detailing discrepancies identified by the Fabricator's Engineer
3. Precast/prestressed concrete work shall be in accordance with CSA A23.3 and A23.4.
bearing pressure and approves subgrade installation prior to pouring concrete for footings foundations. should be discussed with the Engineer prior to shop drawing final submittal. a) Architectural components such as guard and hand rails, flag posts, canopies, ceilings, etc.
f) Position conduit between top and bottom reinforcement with no more than two layers of conduits
4. Precast Manufacturer shall be submit 4 sets of shop drawings of all precast units to the Engineer for review crossing. Add reinforcing, relocate conduits or thickening slab at points of congestion as directed b) Site work elements exterior to the base building such as landscaping components, lamp standards,
4. The Owner shall retain an approved testing agency to carry out density testing of subgrade and base material. 9. See reinforcing notes for minimum reinforcing requirements for composite concrete topping over steel deck. pools, signs, and civil work.
prior to fabrication. Shop drawings shall show all details, including design loads, material specifications, by the Engineer at the Contractor's expense.
Testing of subgrade material is to be carried out immediately prior to installation of slab on grade components embedded mechanical items, etc. Shop drawings to be sealed by a Professional Engineer registered in the c) Cladding, window mullions, glazing and store fronts.
and during lifts as specified by the Geotechnical Engineer. Care must be taken not to disturb subgrade after 10. Design, fabricate and install steel deck to CSA s136 and Canadian Sheet Steel Building Institute standards u.n.o.
province of British Columbia. g) In beams, maximum conduits size parallel to the span must not exceed 2% of the cross section d) Skylights and glass canopies.
approval and prior to pouring concrete. area of the member. e) Attachments and bracing for electrical and mechanical components.
11. Design and detailing of the above items and their attachments are not the responsibility of the Engineer. f) Glass block including attachments.
5. Precast Manufacturer shall be also responsible for the design of all lifting and bracing hardware and shall
5. Contractor shall be responsible for all temporary drainage during excavation. They shall be designed by Specialty Structural Engineers, registered in the province of British Columbia g) Elevators, hoist beams and rail support members.
provide lifting inserts and any additional steel required for handling and lifting the units into place. h) Do not tie conduits / pipes along length of parallel reinforcing. Space minimum 25mm (1") from bars.
and RETAINED BY THE CONTRACTOR, who will seal all related shop drawings, review the components h) Architectural precast and precast cladding.
6. Do not backfill retaining walls until full concrete strength is reached unless otherwise approved by the 6. Precast Manufacturer shall be a member in good standing with the Canadian Precast/Prestressed Concrete and their attachments in the field and provide all required sealed letters (Schedule S-B & S-C) to the j) Window washing equipment and attachments.
Engineer. Consult the Engineer prior to pour to confirm if floor/roof restraint required prior to backfilling. Institute (CPCI). 3. Sleeves and openings. Engineer. k) Interior and exterior light gauge steel stud walls.
l) Roofing material.
7. All footings shall be centered on columns and walls unless noted otherwise. 7. Storage of precast units on site shall be such to prevent staining, contamination by earth and penetration of water. a) Single openings/sleeves in slabs larger than 300mm (12") or a group of openings/sleeves total in area m) Architectural brick veneer.
greater than 0.1 sq. meter in any 1 sq. meter (1 sq. ft. in 10 sq. ft.) is not permitted unless shown on n) Parking slab membrane.
8. Concrete placed under water shall conform to CAN/CSA-A23.1. 8. The Contractor is responsible for providing all necessary bracing as required for construction loads, structural drawings. p) Fall restraint anchors (and any additional required framing not shown on plan).
stability and for resistance to wind and seismic forces. q) Snow guards / fence.
9. Provide 50mm (2") thick concrete ground seal under footings/grade beam if required by site conditions. b) Do not place openings/sleeves through slab within 600mm (24") of columns, ends and intersections r) Library stacks.
and/or by Geotechnical Engineer. 9. The Contractor shall provide a suitable top finish to accept direct application of finish flooring/roofing per of wall.
2. Design and detailing of the above items and their attachments are not the responsibility of the Engineer.
architects requirements.
c)
ABBREVIATIONS They shall be designed by Specialty Structural Engineers, registered in the province of British Columbia
10. For all elevations and drainage slopes, see Architectural Drawings and requirements identified in the Spacing between openings/sleeves through slab shall be not less than 2 times the larger opening
geotechnical report. 10. Where structural concrete topping is to be applied, top surface of precast unit shall be raked (roughened) for size with minimum 100mm (4") clear distance. A.BOLTS - ANCHOR BOLTS LLH - LONG LEG HORIZONTAL and RETAINED BY THE CONTRACTOR, who will seal all related shop drawings, review the components
bonding of topping, u.n.o. and their attachments in the field and provide all required sealed letters (Schedule S-B & S-C) to the
ADDL - ADDITIONAL LLV - LONG LEG VERTICAL
11. Unless noted otherwise, design and supervision of excavation, shoring and underpinning of adjacent d) Openings/sleeves through beams in any directions are not permitted without the written approval
ALT - ALTERNATE L.L. - LIVE LOAD
Engineer. Fast +Epp
structures, where required, shall be carried out by a Professional Geotechnical Engineer retained by 11. Minimum topping thickness (as shown on plan) to be at crown of panel. Contractor to coordinate the panel of the Engineer.
B.L.L. - BOTTOM LOWER LAYER LONGIT. - LONGITUDINAL structural engineers
the Contractor. All costs are to be included in this contract. bearing height to suit required elevations. 3. Secondary components and their attachments shall be designed in accordance with
4. Beams, slab bands and slabs shall be cambered 6.4mm (1/4") for each 3000mm (10'-0") of span B.U.L. - BOTTOM UPPER LAYER LSL - LAMINATED STRAND LUMBER
Part 4 of the B.C. Building Code as in GENERAL section. Suite 201
12. Where footing elevations vary, follow requirements of typical details shown on drawing. Contractor (both top and bottom surface). BCE - BOTTOM CHORD EXTENSION LVL - LAMINATED VENEER LUMBER
1672 West 1st Ave T 604 731 7412
shall establish footing elevations based on all requirements including maximum slopes, and Electrical, BOT - BOTTOM L.V. - LENGTH VARIES 4. Sealed shop drawings of the secondary or non-structural components which may affect the primary Vancouver BC F 604 731 7620
Mechanical and Architectural information. 5. Submit locations of construction pour joints together with pour sequence to the Engineer for review prior B/U - BUILT UP Mf - FACTORED MOMENT structural system shall be submitted to the Engineer only for the review of their effect on the primary Canada V6J 1G1 [email protected]
to framing. Cf - FACTORED COMPRESSION FORCE N. STUDS - NELSON STUDS structural system.
13. Footing elevations, if shown, are for bidding purposes only, are not final, and may vary according to CANTLV - CANTILEVERED OPP - OPPOSITE
site conditions. All footings must be taken to a bearing layer approved by the Geotechnical Engineer. 6. See concrete section of "Concrete Notes" for stripping of forms. Reshoring of suspended slabs must be CLR - CLEAR O.F. - OUTSIDE FACE 5. Sub-contractor of these components is responsible for protection of connections of dissimilar metals
approved by Shoring Engineer prior to stripping. Shores shall remain until specified strength has been reached CONC. - CONCRETE P.C. - PRECAST CONCRETE against galvanic corrosion.
IBI/HB Architects
14. Bearing surfaces must be protected from freezing before and after footings are poured. and minimum 28 days after pour (minimum 56 days if fly ash content exceeds 25%). CONT - CONTINUOUS PSL - PARALLEL STRAND LUMBER 700 - 1285 West Pender Street
C'SINK - COUNTERSINK P/T - POST-TENSION 6. In addition to construction tolerance, secondary components shall be detailed for the following
Vancouver BC V6E 4B1 Canada
7. Minimum reinforcing: C.I.P. - CAST IN PLACE REINF. - REINFORCEMENT building movement and deflection:
C/W - COMPLETE WITH RS - ROUGH SAWN LUMBER tel 604 683 8797
a) See minimum reinforcing in Reinforcing Notes. a) Vertical deflections of beams, slabs and decking: L/180, (25mm min.)
DRAWING LIST b) 1-15M top and bottom continuous at edge of slab.
CJ
D.L.
- CONTROL JOINT
- DEAD LOAD
R/W
S.D.L.
- REINFORCED WITH
- SUPERIMPOSED DEAD LOAD
Differential deflections of edge beams and edges of slabs: L/240, (16mm min.)
fax 604 683 0492
c) 2-15M each side of openings (extending 600mm (2'-0") pass edge of opening).
No. DWG. No. DWG. TITLE plus 1-15M 1200mm (4'-0") diagonal, top and bottom, at each corner. DIAG. - DIAGONAL S.O.G. - SLAB ON GRADE b) Horizontal drift during wind and earthquake between floors:
d) 2-15M 1200mm (4'-0") diagonal top at re-entrant corners. EL - ELEVATION S.S. - STAINLESS STEEL Drift without damage to components: 0.003 x height
1 S1.0 GENERAL NOTES E.F. - EACH FACE STAG - STAGGERED Drift without collapse to components: 0.010 x height for post-disaster buildings
8. Unless noted otherwise: E.S. - EACH SIDE STD - STANDARD
E.W. - EACH WAY STIFF - STIFFENER c) Movement at expansion joints (u.n.o.):
2 S2.0 LOWER FLOOR/FOUNDATION PLAN
Perpendicular: ± 50mm (2") min.
a) Reinforcement shown on plan thus: EXIST. - EXISTING STIRR - STIRRUP
Top Reinforcement FDN - FOUNDATION Tf - FACTORED TENSILE FORCE Parallel: ± 50mm (2") min.
3 S2.1 MAIN FLOOR PLAN Bottom reinforcement FTG - FOOTING TJI - TRUSS JOIST Vertical: ± 25mm (1") min.
b) Reinforcement notation callup: GA. - GAUGE T.L.L. - TOP LOWER LAYER
4 S2.2 ROOF PLAN 12-20M4900 - means twelve 20M bars, 4900mm (16'-0") long. GALV - GALVANIZED TRANSV. - TRANSVERSE
2-C15M1800 - means two 15M bars, 1800mm (6'-0") long with 90° CSA standard hook. GL - GLULAM T.U.L. - TOP UPPER LAYER
5 S3.0 TYPICAL SECTIONS AND DETAILS (length includes standard hook) H1E - HOOK ONE END T&B - TOP AND BOTTOM
2-C15M @300 H2E - means two 15M bars spaced at 300mm (12") with H2E - HOOK TWO ENDS TYP - TYPICAL
90° CSA standard hook at two ends. HD - HOLD DOWN U.D.L. - UNIFORMLY DISTRIBUTED LOAD
6 S3.1 TYPICAL SECTIONS AND DETAILS
H.D. GALV. - HOT DIPPED GALVANIZED U.N.O. - UNLESS NOTED OTHERWISE
4-15M @300 H2E 450 - means four 15M bars spaced at 300mm (12") with
HDR - HEADER U/S - UNDER SIDE
7 S4.0 WALL ELEVATIONS 450mm (18") long 90° hook at two ends.
HORIZ - HORIZONTAL Vf - FACTORED SHEAR FORCE
c) Center slab and beam top reinforcement over supports. Hooks shown are CSA standard hooks. I.F. - INSIDE FACE VERT - VERTICAL
8 S4.1 WALL ELEVATIONS
9. See minimum reinforcing notes for slab temperature steel. Place temperature steel immediately above
and transverse to slab bottom steel, u.n.o.
9 S5.0 SECTIONS AND DETAILS
10. Shear studs indicated on plan to be Decon Studrails (or approved equivalent by the Engineer in
10 S5.1 SECTIONS AND DETAILS accordance with ASTM-A108 & A1044 [Fy= 350 MPa (51 ksi), Fu= 450 MPa (65 ksi)]. Studs to be
welded in accordance to AWS D1.1 & CSA W59. Refer to "Field Review and Testing" section for
11 S5.2 SECTIONS AND DETAILS testing requirements.
LEGEND
CONCRETE WALL TYPE AS PER
W WALL SCHEDULE AND PLAN
3
S4.1 4 CONCRETE WALL BELOW
1
S4.1
2 S5.0 NON-LOAD BEARING CMU WALL
S5.0
LOAD BEARING CMU WALL
C4
Z2
Z2
Z2
Z2
Z2
Z2
Z2
Z1
Z1
Z1
W3 W3 W3 W3 W3 W3
C INDICATES BEAM, HEADER OR HIP
STEP FTG UP
BP C1
SCHEDULE
1
Z1
W4
R/W 10M @500 EACH WAY DWG. S5.1
AT MID DEPTH ON STEEL BRACE FRAME TYPE
BF
6 MIL POLY MOISTURE BARRIER ON SEE DWGS S4.0 & S4.1 FOR DETAILS
COMPACTED GRANULAR SUB BASE
W1
Z
RECOMMENDATIONS
SCHEDULE
W1
F2 F2
WATER TANK SLAB AND WALLS:
PROVIDE CONCRETE WATERPROOFING ADMIXTURE
(KRYSTOL INTERNAL MEMBRANE,XYPEX ADMIX C-500
10350
F2 OR APPROVED EQUAL) AT LOCATIONS INDICATED.
INSTALL PRODUCT AS PER MANUFACTURERS
Z1
INSTRUCTIONS AND SPECIFICATIONS. PROVIDE
W4
COMPLETE WATERSTOP SYSTEM AT ALL JOINTS IN
ACCORDANCE WITH MANUFACTURER'S WARRANTY
REQUIREMENTS
300
W2 W2
COLUMN SCHEDULE
MARK SIZE
Z1
C1 HSS 102x102x9.5
W4
C2 HSS 152x152x8.0
F3
W2
W2
W2
WATER TANK WATER TANK C3 W310x97
F2
C4 HSS 203x102x9.5
Z1
Z1
Z1
W1 W1 W2 W2
1000
B
6-20M VERTS
S5.0
Z2
10M TIES @150
STEP FTG UP
UP 4-15M VERTS
Z1
STEP FTG UP
10M TIES @150
W7
2
S4.0
W7
F1 CONCRETE WALL SCHEDULE
FOR STAIR REINF SEE SECT 4/S3.1
F1 MARK THICKNESS (MIN.) REINFORCEMENT
15M @300 VERTS I.F.,
W1 200
15M @450 HORIZ. I.F.
15M @150 EACH WAY,
W2 250
W1
W1 EACH FACE
15M @400 VERTS E.F.,
W3 250
10M @450 HORIZ. E.F.
15M @300 VERTS CENTERED
W4 200
15M @450 HORIZ. CENTERED
300 DP. FTG R/W 15M @400 TRANSV. TOP & BOT. W6 200 CMU WALL REINF AS PER GENERAL NOTES
& 8-15M LONGIT. BOT.
15M @450 EACH WAY,
W7 200
CENTERED
REINF AS PER GENERAL NOTES,
FOR WALL AND FTG CONTINUATION FOR WALL AND FTG CONTINUATION W8 150 CMU WALL
ALL CELLS FULLY GROUTED
SEE DWG S2.1 SEE DWG S2.1
Z1
12450
FOOTING SCHEDULE
W1 MARK SIZE REINFORCEMENT
1000
1650 3300
1A 2 2A
LEGEND
CONCRETE WALL TYPE AS PER
W WALL SCHEDULE AND PLAN
C1
BP 1
BP 1
C
C
1
1
W9
C INDICATES BEAM, HEADER OR HIP
BM1 BM2
BP 1
BM1
x INDICATES POINT LOAD ON
C
3
BEAM FROM FLOOR ABOVE
W9
W8
W8
TYP
10
S5.0 COLUMN TYPE AS PER
BP C1
SCHEDULE
1
B P C1
1
305 DP HOLLOW CORE PANELS 305 DP HOLLOW CORE PANELS BASE PLATE TYPE SEE
DWG. S5.1
+ 50 MIN CONC TOPPING AT MIDDLE + 100 MIN CONC TOPPING AT
BF STEEL BRACE FRAME TYPE
OF PANEL R/W 10M @450 E.W. MIDDLE OF PANEL R/W 10M
SEE DWGS S4.0 & S4.1 FOR DETAILS
@300 E.W. SLOPE TOPPING TO
ACHIEVE FLOOR DRAINAGE
5 ZONE REINF TYPE SEE
Z
SCHEDULE
S5.0
W8 TYP
10350
BP 2
C
3
W8 TYP
W9
BF3
BP C1
1
W8
W8
W8
11
15M3000 @300 15M3000 @300
S5.0 COLUMN SCHEDULE
TYP
MARK SIZE
B P C1
BP C1
C1 HSS 102x102x9.5
3
1
W9 B C2 HSS 152x152x8.0
BP 2
C
3
BF5
3
12
C
9 9 6 C3 W310x97
SIM. S5.0
S5.0 S5.0 S5.0
2 C4 HSS 203x102x9.5
S4.0
200 CONC. SLAB ON GRADE 200 CONC. SLAB ON GRADE
R/W 10M @500 EACH WAY R/W 10M @500 EACH WAY
AT MID DEPTH ON AT MID DEPTH ON
6 MIL POLY MOISTURE BARRIER ON 6 MIL POLY MOISTURE BARRIER ON CONCRETE WALL SCHEDULE
COMPACTED GRANULAR SUB BASE COMPACTED GRANULAR SUB BASE
15M @450 B.U.L.
W7
15M @300 VERTS I.F.,
W1 200
15M @450 HORIZ. I.F.
15M @150 EACH WAY,
250
BF2
W2
EACH FACE
15M @400 VERTS E.F.,
W3 250
10M @450 HORIZ. E.F.
20M @300 B.L.L. 15M @300 VERTS CENTERED
W4 200
15M @450 HORIZ. CENTERED
BP 1
C
1
W6
F4
4 15M @450 EACH WAY,
600
600
W7 200
CENTERED
S5.0
F1 TYP U.N.O. REINF AS PER GENERAL NOTES,
W8 150 CMU WALL
ALL CELLS FULLY GROUTED
DOWN
12450
BP 2
C
3
FOOTING SCHEDULE
BP C1
1
W6
W7
C 2
W6
BP
1
W6 F5 1750x1750x300 THICK. 6-15M EACH WAY BOT.
300 WIDE SLAB THICKENING 4
UNDER ALL NON-LOADBEARING IBI/HB Architects
CMU WALLS AS PER TYP DETAILS S5.0 F4 700 - 1285 West Pender Street
6-15M LONGIT. BOT.
F6 3000x1500x300 THICK. Vancouver BC V6E 4B1 Canada
BP C1
BP 1
BP 1
BF1
C
F4
1
BP C1
3
W7
A
3
S5.0
F4
F5
1
F6
S4.0
1650 3300
1A 2 2A
LEGEND
CONCRETE WALL TYPE AS PER
W WALL SCHEDULE AND PLAN
2000 2000 2000 1750
L76x76x6.4 TYP AT 3 CONCRETE WALL BELOW
PERIMETER OF ROOF EDGE OF ROOF
S4.1 HSS 89x89x4.8 CROSS BRACE
3 5 4 5 NON-LOAD BEARING CMU WALL
S5.1 S5.1 S4.1 S5.2
LOAD BEARING CMU WALL
76mm DP x 1.22
76mm DP x 1.22 STEEL DECK SPAN DIRECTION OF HOLLOW
STEEL DECK TYP CORE PANELS, SEE PLAN FOR SIZE
BF4 TYP
2000
L76x76x6.4 DIAG. BRACE
W410x60
S5.1 COLUMN TYPE AS PER
BP C1
5 SCHEDULE
1
S5.2 BASE PLATE TYPE SEE
DWG. S5.1
2000
BF
SEE DWGS S4.0 & S4.1 FOR DETAILS
3.45 kPa
W460x97 W460x97 W250x45 W250x45
ZONE REINF TYPE SEE
Z
SCHEDULE
6
S5.2
3.45 kPa
HSS 102x102x13*
3 EQUAL SPACES
W460x97 CANTILV.
STEEL CANOPY
BELOW, SEE DWG
76mm DP x 1.22 STEEL DECK TYP
S5.3 FOR DETAILS
W410x74
2000
10350
125 SLAB
1000
W460x97 W460x97 W250x45 W250x45
6400
3.45 kPa
SNOW LOAD
HSS 89x89x4.8 CROSS BRACE
5500
1000
SNOW LOAD
10M @300 H2E T.L.L.
BF3
W410x60
HSS 102x102x6.4 10M @300 B.U.L.
HANGER W250x45
1000
SNOW LOAD
HSS FRAMES, TYP.
HSS 102x102x13*
2730
S5.1
6000
4
L. .
O x6
C 02
1000
B 1
8.25 kPa
U 2x
7.56 kPa
1000
ST 10
0 mm
5.5 kPa
0 mm
S
HS
W460x97 HSS 102x102x13* W460x97 (HIGH) W460x97 (UNDER LOW BEAM)
W460x97 (HIGH)
250
B
4.75 kPa
HS ST
S UB
SNOW LOAD
100
10 C
BF5
2x O
2 4
10 L.
1750
2x
S4.0 S5.2
6.
W250x28 CANTILV. AT
4
HIGH ROOF
W310x39
W150x37 TYP AT
HSS 102x102x13*
LOW MECH
HSS 89x89x4.8 CROSS BRACE
3.45 kPa
PLATFORM
EDGE OF ROOF EDGE OF ROOF
EXTENT OF LOW
MECH PLATFORM
W410x85 (LOW)
W100x19 (HIGH)
W410x85 W460x97 W250x28 CANTILV.
BF2
1700 TYP 38mm DP x 1.22 STEEL 1 2
NON-LOADBEARING CMU DECK AT LOW MECH
S5.2 S5.2
W460x89
WALLS FROM BELOW PLATFORM WITH
64mm CONCRETE
W460x74
TOPPING WITH
4 EQUAL SPACES
W410x85 (LOW)
W100x19 (HIGH)
W410x85 W460x97 W250x28 CANTILV.
12450
F
S5.1 SLOPE ROOF DOWN
W460x89 (UNDER)
2
S5.1
IBI/HB Architects
W460x74
W460x89
700 - 1285 West Pender Street
Vancouver BC V6E 4B1 Canada
HSS 102x102x13*
A
W100x19 (HIGH)
1650 3300
1A 2 2A
ROOF PLAN
1:50
CONC. UPSTAND WHERE REQUIRED
C/W 2-15M @ TOP CONT. AND
DOWELS TO MATCH WALL VERTS.
STEP
MAX.
1050 MAX.
600
`D'
`D'
BEND REINF. WITH HICKEY
R.
75
BAR AS PER CSA STANDARDS
CL
CSA STANDARD CSA STANDARD CSA STANDARD
20x20 NOTCH FILLED BACKFILL WITH FREE DRAINING
HOOK HOOK HOOK
`D'
WITH CAULKING OR MATERIAL AS SPECIFIED IN
APPROVED BEARING
DAMPROOF TO ARCH'S SPEC. SOILS REPORT
1 MAX.
DISCONTINUE EVERY 200 WIDE EXT. WATERSTOP
2 SECOND HORIZ. BAR
AT 'V' JOINT LOCATIONS
`D' = FOOTING DEPTH OUTSIDE FACE OF WALL
SEE PLANS
TENSION SPLICE
TENSION SPLICE
FOR SLAB REINF. & DEPTH
TYP.
900
EXTEND HOOK TO
SEE PLAN BACK FACE OF WALL
TYPE 1 TYP.
EXTEND HOOK TO
BACK FACE OF WALL
TYP.
FOR WALL REINFORCING
SEE GENERAL NOTES
TENSION
LAP
NOTES:
2-15M EA. SIDE
1) HORIZ. DOWELS TO MATCH SIZE
STEP
MAX.
600
'D'
- 1:20
`D'
CL
TENSION SPLICE
TENSION LAP
TENSION SPLICE
TYPE 2 STANDARD HOOK
EXTEND TO BACK FACE
OF WALL TYP 200 WIDE WATERSTOP OUTSIDE FACE OF WALL
1 TYPICAL STEPPED STRIP FOOTING HORIZ. CORNER REINF.
TENSION SPLICE
SEE GEN. NOTES
- 1:50 AT BACK FACE OF WALL FOR WALL REINF. AND
SIZE & SPACING TO THICKNESS SEE SCHEDULE
MATCH WALL HORIZ. REINF. AND GENERAL NOTES
AT ANCHOR END
TO MATCH WALL VERT REINF.
+ 1-15M HOR. TOP & BTM
SINGLE CURTAIN DOUBLE CURTAIN
BASE PLATE FOR 38x89 KEY CONTINUE ALL BARS ACROSS JOINT
HSS COLUMNS: OR PROVIDE FULL TENSION SPLICES
HSS 203x203, HSS 178x178 = 330x330x25
BASE PLATE HSS 152x152, HSS 127x127 = 280x280x19
HSS 102x102, HSS 76x76 = 230x230x16
MIN. 100 COVER AROUND BOLTS TYP. C/W DOUBLE NUT AT WITH COMPRESSIBLE FIRE RATED MATERIAL
BASE PLATE WHERE REQUIRED.
90
ANCHOR END
RETAINING WALL
SEE PLAN & SECTIONS BASE PLATE FOR
FOR REINF. 25
HSS COLUMNS:
CLR.
CLR.
75
TYP.
HSS 152x152, HSS 127x127 = 280x280x19
32
HSS 102x102, HSS 76x76 = 230x230x16 DOWELS FROM SUSPENDED SLAB
50
TO MATCH MASONRY WALL VERTS
CLR.
600 MIN.
2 TYP. HSS COLUMN AT FOOTING 38x89 CONT. KEY BASE PLATE AS ABOVE
MIN.
75
COVER AROUND BASE PLATE BOND BEAM
100
90
DRAIN TILE SEE PLUMBING C/W 2-15M CONT.
KEY FROM 38x65 FOR SLAB
TYP.
AND ARCH DWGS.
250
UP TO 190 DP. 2ND COURSE FROM TOP
KEY FROM 38x89 FOR SLAB
FROM 200 TO 240 DP.
3000 MAX.
KEY FOR SLAB 250 AND OVER
USE 1/3 THE SLAB DEPTH BOTTOM REINF. CONT. FOR CONC. PEDESTAL
COMPACTED FILL TO SEE PLAN 200 OR 250 CONCRETE MASONRY WALL
THROUGH JOINT
NOTES: THE GEOTECHNICAL REINFORCED AS PER GENERAL NOTES
ENGINEER'S APPROVAL SEE ARCHITECTURAL DWGS FOR LOCATIONS
1) THIS DRAWING TO BE READ IN CONJUNCTION WITH GEOTECHNICAL
ENGINEER'S AND MECHANICAL ENGINEER'S DRAWINGS.
CLR
75
structural engineers
ALL SLABBAND REINF. CONT. KEY FROM SLAB (BEYOND) Suite 201
CONT. THROUGH JOINT STOP AT SLABBAND 1672 West 1st Ave T 604 731 7412
MIN.
-
200
1:20
SLABBAND
1
EQ. EQ.
2
SLAB
IBI/HB Architects
& REINF SEE FOOTING SCHEDULE
700 - 1285 West Pender Street
Vancouver BC V6E 4B1 Canada
(T = SLAB DEPTH)
TYPICAL NON-LOAD BEARING
10
( CONCRETE
OR STEEL ) 12
-
5 EQ. SPACES 38 MASONRY WALL SECTION
1:20
BEAM
DEPTH
SLAB
25
BEARING =144kPa
FREE DRAINING BACKFILL
3. GEOTECH ENGINEER TO
INSPECT BACKFILL AND
CONFIRM ASSUMED
BEARING AND LOADING
BAR (2)
4. fc'=25MPa @28 DAYS
MIN.
90
fy=400MPa
(DO NOT BACKFILL UNTIL
"B"
CLR.
MIN.
50
BAR (3)
200
"T"
CLR.
DRAIN TILE
75
APPROVED BEARING
BY GEOTECH. ENGINEERS
SEE ARCH DWGS
"L" FOR STAIR DIMENSIONS
CL 0
CONT.KEY
R
5
0
15
1 TYP. RETAINING WALL SECTION COMPACTED FILL
T.O.GRADE
- 1:20
PROTECTION
MIN. FROST
2-15M CONT. BOT
600
4 TYP. STAIRS ON GRADE
0.2 T
LAP
- 1:20
T
T/2
SECOND POUR
1:3 SLOPE
CONSTRUCTION JOINT
CONTROL JOINT
NOTES :
1. CONSTRUCTION JOINTS TO BE INSERTED WHERE CONSTRUCTION
OPERATIONS ARE SUSPENDED FOR 30 MINUTES OR MORE.
2. CONTROL JOINTS TO BE SAW-CUT WITHIN 4 TO 12 HOURS AFTER
CONCRETE HARDENS.
IBI/HB Architects
700 - 1285 West Pender Street
Vancouver BC V6E 4B1 Canada
3
S5.2
W460
W410
W410
8
4.
HS
HSS 102x102x6.4 WINDOW HEADER HSS 102x102x6.4 WINDOW HEADER
2x
S
CONC. COLUMN AS
10
10
2x
PER PLAN
2x
10
10
S
BF 1
2x
HS
4.
8
HSS 102x102 COLUMNS
AS PER PLANS TYP
1 1A 2 2A 3
1650 11850 13500 3300
2 SIM.
S5.2
4
S5.2
F
S5.1 W460 W460
W310 COLUMN AS
PER PLANS
S5.0
IBI/HB Architects
700 - 1285 West Pender Street
Vancouver BC V6E 4B1 Canada
10Mx900 U-BARS @300 10Mx900 U-BARS @300 10Mx900 U-BARS @300 10Mx900 U-BARS @300
C B A
10350 12450
B
S5.1
A
S5.1
W460 W460
W410 W410
HSS 102x102 COLUMN HSS 152x152 COLUMN HSS 152x152 COLUMN HSS 102x102 COLUMN
AS PER PLANS AS PER PLANS AS PER PLANS AS PER PLANS
HS
.8 S
HS x4 89
.8 S x 89 x8
x4 89 89 9x
x 89 x8 S 4.
E 89 9x HS 8 E Fast +Epp
S 4. BF 2 SIM.
S5.1 HS 8 S5.1
BF 3 T.O. MAIN FLOOR
structural engineers
IBI/HB Architects
700 - 1285 West Pender Street
Vancouver BC V6E 4B1 Canada
AS PER ARCH
CONC. S.O.G. SEE PLANS FOR CONC. S.O.G. SEE PLANS FOR CONC. S.O.G. SEE PLANS FOR CONC. S.O.G. SEE PLANS FOR
SIZE & REINF SIZE & REINF SIZE & REINF 300 SIZE & REINF
300 B
200
10M TIES @300
8-15M VERTS
100 100
BACKFILL BOTH SIDES OF BACKFILL BOTH SIDES OF BACKFILL BOTH SIDES OF BACKFILL BOTH SIDES OF 200
WALL EQUALLY WALL EQUALLY WALL EQUALLY WALL EQUALLY
B DETAIL
S2.0 1:20
600
600
DOWELS TO MATCH WALL REINF DOWELS TO MATCH WALL REINF DOWELS TO MATCH WALL REINF. DOWELS TO MATCH WALL REINF.
ALT. HOOK ALT. HOOK ALT HOOK ALT HOOK
600
38x89 CONT KEYWAY 38x89 CONT KEYWAY 38x89 CONT KEYWAY 38x89 CONT KEYWAY
3 C C C B
75
CMU WALL AS PER PLAN DOWELS TO MATCH CMU CMU WALL AS PER PLAN DOWELS TO MATCH CMU WALL
WALL VERT REINF VERT REINF
HSS 102x102 COL AS
HOOK DOWELS INTO CONC. HOOK DOWELS INTO CONC. HOOK DOWELS INTO CONC. PER PLANS
TOPPING. SIZE & SPACING TO TOPPING. SIZE & SPACING TO TOPPING. SIZE & SPACING TO
MATCH CONC WALL VERT REINF MATCH CONC WALL VERT REINF MATCH CONC WALL VERT REINF
600
CONC. TOPPING 900 CONC. TOPPING 900 CONC. TOPPING CONC. TOPPING CONC. TOPPING 1-15M ANCHOR BAR
150
AS PER PLAN AS PER PLAN AS PER PLAN AS PER PLAN AS PER PLAN 600
3-20M CONT
950 MIN.
950 MIN.
1 CONC. S.O.G. REINF
1000
CORE PLUG BY PRECAST AS PER PLAN
2-C15M AS SHOWN AT
CORE PLUG BY PRECAST SUPPLIER CORE PLUG BY PRECAST
EACH NOTCH C/W 15M
PROVIDE TEMP. LATERAL SUPPLIER PROVIDE TEMP. LATERAL FOR REMAINDER OF DETAIL SUPPLIER PROVIDE TEMP. LATERAL
HOR. CONT. AT EACH C10M1200 GROUTED INTO
END OF HOOK RESTRAINT TO TOP OF C10M1200 GROUTED INTO RESTRAINT TO TOP OF SEE SECTION 7/- C10M1200 GROUTED INTO RESTRAINT TO TOP OF
EACH HOLLOWCORE PANEL
WALL UNTIL THE S.O.G. EACH HOLLOWCORE PANEL WALL UNTIL THE S.O.G. EACH HOLLOWCORE PANEL WALL UNTIL THE S.O.G.
JOINT
900
400 LG. NOTCH @1000 IN JOINT 1-15M CONT EACH FACE JOINT 50
TOPPING IS CAST TOPPING IS CAST 100 MIN. HOLLOWCORE BEARING TOPPING IS CAST
HOLLOWCORE AND 1200 FROM 100 MIN. HOLLOWCORE BEARING 100 MIN. HOLLOWCORE BEARING
EACH END TO ALLOW FOR ON CMU WALL (BEARING PANEL
ON CMU WALL (BEARING PANEL BY PRECAST SUPPLIER) ON CMU WALL (BEARING PANEL
REBAR PLACEMENT AND CONC. BY PRECAST SUPPLIER) 3-25M CONT TOP & BOT FOR BEAM REINF SEE BY PRECAST SUPPLIER)
FILL OF END CORE. 250 C/W 10M TIES @300 250 SECTION 7/-
3 Fast +Epp
structural engineers
Suite 201
6 122
150 CMU WALL AS PER PLAN IBI/HB Architects
13Ø (A325) THREADED ROD 250x250x10 BEARING PLATE 700 - 1285 West Pender Street
AND NUT @1200 EACH WAY Vancouver BC V6E 4B1 Canada
BEND WALL VERT REINF INTO SET IN GROUTED JOINT CONC. TOPPING AS PER PLAN
40 40
TOPPING WITH HICKEY BAR BETWEEN HOLLOWCORE PANELS tel 604 683 8797
CONC. TOPPING &
HOLLOWCORE PANELS AND fax 604 683 0492
REINF AS PER PLAN
CONC. TOPPING AS PER PLAN
55
600
122
450 100
100
HSS COL AS
B PER PLAN
40 40
153
200
19mm BASE PLATE ON 25mm
55
6
NON SHRINK GROUT C/W 2-19Ø
350x350x19 BASE PLATE ON ANCHOR BOLTS
25mm NON SHRINK GROUT C/W
BREAK FACE OF CMU WALL 45 45 4-25Ø x400 LONG THREADED
AND GROUT INFILL AFTER RODS WITH DOUBLE NUT &
HOLLOWCORE
PROJECT
13
150
400 LG. NOTCH @1000 IN 15M DOWELS TO MATCH WALL 100 200 100
HOLLOWCORE AS PER PLAN
HOLLOWCORE AND 1200 FROM VERTS. EPOXY 90mm INTO (FULLY GROUT ALL END CELLS
EACH END TO ALLOW FOR CONC. TOPPING AS SHOWN) TYP. S4.0 1:10
REBAR PLACEMENT AND CONC.
FILL OF END CORE. CABLE TRAY ATTACHMENT BY
200 CONC. WALL
OTHERS (C/W FULL STRENGTH HOLLOWCORE PANELS TO BE PLACED
REINF AS PER PLAN COUPLER ATTACHMENT TO TIGHT TOGETHER.
THREADED ROD DRILL HOLE MIN. AS REQUIRED AFTER
PLACEMENT TO ALLOW FOR THREADED
ROD PROJECTION
7.0 KN (UNFACTORED)
MAX. LOAD
40
5
5 100 100
80
6
80
80
WP
80
80
80
80
150
40
38
2 ERECTION BOLTS
15
0 65 65
100
150
T.O. STEEL DECK 8 W460 AS PER
60 WT100x15.5 W410 AS PER
40 65 100 PLANS 6
12
8 PLANS 100x6mm FULL HEIGHT PLATE C/W
3-19Ø A325 BOLTS EACH SIDE
6
HSS 102x102 AS
5
W460 AS PER PLAN
40 40
17
PER PLANS
40
80
80
80
80
80
DETAIL
80
40
40
15 1:10
0
15
0 S4.0
W250 AS PER
PLANS
150
150
25
10mm KNIFE PLATE C/W 8
4-19Ø A325 THRU BOLTS 8 HSS CROSS BRACE
5
W460 AS PER
17
AS PER ELEVATIONS
PLANS
17
COLUMN C/W 4-19Ø A325 FOR REMAINDER OF
5
KNIFE PLATE DETAIL
BOLTS
SEE DETAIL A/- BEAM AND DECKING
AS PER PLANS
FOR REMAINDER OF HSS 152x152 AS 100
19mm KNIFE PLATE
KNIFE PLATE DETAIL PER PLANS
SEE DETAIL A/- 65
HSS CROSS BRACE
AS PER ELEVATIONS HSS CROSS BRACE
AS PER ELEVATIONS
40
A DETAIL B DETAIL C DETAIL
80
S4.1 1:10 S4.1 1:10 S4.0 1:10
80
40
106 244
262 75 75 10mm PLATE C/W 3-19Ø A325 BOLTS
EACH SIDE
40 40 8
8 HSS COL AS HSS 102x102 AS
8 PER PLAN PER PLANS
40 40
100
HSS 152x152 AS
75
75
50 50
PER PLANS
HSS COL AS
HSS COL AS
75
75
100
PER PLAN CONNECTION PLATE FOR
PER PLAN
X BRACE SEE DETAIL
2-19Ø A325 THREADED RODS 2-19Ø A325 THREADED RODS 40 135 135
6-15Mx400 LONG WELDABLE
5
38 EMBED 300 C/W DOUBLE NUT & EMBED 300 C/W DOUBLE NUT & REBAR DOWELS
75x75 WASHER PLATE IN CONC. 75x75 WASHER PLATE IN CONC.
HSS CROSS BRACE
T.O. CONC. WALL AS PER ELEVATIONS
T.O. TOPPING
12
19mm KNIFE PLATE BASE PLATE TYPE 1 BASE PLATE TYPE 2 BASE PLATE TYPE 3
200
6
BASE PLATE TYPE 3
1 1A
1700 MAX. 1490
S4.1 1:10
GL 8
Suite 201
1672 West 1st Ave T 604 731 7412
Vancouver BC F 604 731 7620
Canada V6J 1G1 [email protected]
IBI/HB Architects
76 WIDEx6mm STIFF PLATE 700 - 1285 West Pender Street
6 ROOF BEAM AS PER PLAN EACH SIDE W100x19 CONT Vancouver BC V6E 4B1 Canada
DIAG. BRACE AS
50 50
PER PLAN
6
6 40 40 450
75
262x150x16 PLATE C/W 6mm PLATE
150x10 THICK CONNECTION PLATE 4-19Ø A325 BOLTS 277
C/W 19Ø A325 BOLT IN 50 LONG 6
VERT SLOTTED HOLE IN PLATE
6
6
HSS HEADER FOR GLAZING
AS PER PLAN
6
6
AS PER PLAN
100 STEEL DECK AS PER PLAN 110x6mm FULL HEIGHT
STIFF. PLATE
6mm BENT PLATE CONT BENT PLATE AS PER
BETWEEN W250 BEAMS 100 SECTION 2/-
℄ W250 BEAM
150
150
5 50-150 65
5 50-150
4A
40
CUT W250 TO 150 DEEP AND WELD -
BOTTOM FLANGE TO WEB. FLANGE
40 40
6 SEE ARCH DWGS
80
160
PROFILE TO MATCH W250 TOP TYP
80
80
6
80
FLANGE
2-19Ø A325 BOLTS.PROVIDE
80
SHAPED SHIM PLATES AT BOLT
40 40
80
LOCATIONS
W250 AS PER 160x100x10MM CONNECTION PLATE
80
50
65 PLANS C/W 2-19Ø THREADED STUDS
80
80
10
PLANS
75
6
40
50
W250 AS PER
100 WIDE x10mm FULL PLANS
HEIGHT STIFF PLATE TYP 35 65
35 65
110x10mm PLATE W460 AS PER
W460 AS PER W460 AS PER PLANS
PLANS PLANS W310 COLUMN AS
100 76x6mm STIFF PLATE PER PLANS
EACH SIDE 10mm PLATE C/W 5-19Ø
19Ø A325 THRU BOLTS THRU BOLTS
TYP
℄ W310 COLUMN
SEE ARCH
65 35
FRAMES
∠102x102x9.5 C/W 2-13Øx76 LG N. STUDS
HSS 127x76x9.5 TYP 6 2-19Ø A325 BOLTS
6
76 76
150
35 65
100
HSS 102x102x6.4 C/W 10mm CAP 25 6
PLATE WITH 2-19Ø A307 THREADED
RODS CP WELDED TO PLATE
2A
W460 AS PER
∠127x127x9.5x200 LG W460 AS PER PLAN
6mm PLATE PLANS 6
C/W 3-15M 600 AND W250 AS PER
3-16Øx125 lg N. STUDS PLANS
125 SLAB AS PER PLAN
Fast +Epp
structural engineers
Suite 201
1672 West 1st Ave T 604 731 7412
Vancouver BC F 604 731 7620
Canada V6J 1G1 [email protected]
IBI/HB Architects
700 - 1285 West Pender Street
Vancouver BC V6E 4B1 Canada
TYP
1
-
1:50
PLACE 1-20M VERT IN EACH WALL REINF AS PER PLAN WALL REINF AS PER PLAN
CELL WITH EMBED PLATE & IN AND SCHEDULE AND SCHEDULE
EACH ADJACENT CELL
CMU WALL AS PER PLAN 25 TYP CONC. WALL AS PER PLAN CONC. WALL AS PER PLAN
10mm PLATE SLOPED AS HSS AS PER PLAN 3B HSS 102x102 AS
PER ARCH REMAINDER OF DETAIL AS
- PER PLAN
15M2000 PLACED TIGHT TO HSS T.O. STEEL VARIES
HEAD OF N. STUD 15M2000 PLACED TIGHT TO PER SECTION 1/- 15M2000 PLACED TIGHT TO SEE ARCH DWGS
HEAD OF N. STUD HEAD OF N. STUD
25
6
25 TYP
255x235x16 EMBED PLATE C/W 255x235x16 EMBED PLATE C/W EMBED PLATE AS PER
235
4-19Øx125 LG N. STUDS & 4-19Ø A307 4-19Øx150 LG N. STUDS & 4-19Ø SECTION 2/-
THREADED RODS CP WELDED TO PLATE 16mm THICK PLATE BOLTED TO A307 THREADED RODS CP
EMBED PLATE BEHIND WELDED TO PLATE
10mm THICK PLATE
25 TYP
25 TYP
25 TYP
END PLATE WELDED TO HSS AND END PLATE WELDED TO HSS AND END PLATE WELDED TO HSS AND
BOLTED TO EMBED PLATE SEAL BOLTED TO EMBED PLATE BOLTED TO EMBED PLATE
WELD
SEAL WELD HSS AS PER PLAN
PLACE 6mm HIGH DENSITY TEFLON 6 50-200 G PLACE 6mm HIGH DENSITY TEFLON PLACE 6mm HIGH DENSITY TEFLON
PAD BETWEEN STEEL PLATES PAD BETWEEN STEEL PLATES PAD BETWEEN STEEL PLATES
NO FUSION NO FUSION
WELDS ALLOWED
1A WELDS ALLOWED
1A 3A
10 - 10 - -
255
50 50
6
50 MAX.
235
Suite 201
25
HSS 102x102 CONT. TO 1672 West 1st Ave T 604 731 7412
6 Vancouver BC F 604 731 7620
PLATE BEYOND
Canada V6J 1G1 [email protected]
IBI/HB Architects