Manual
Manual
K 1050 P
www.kraenzle.com
Technical data
Dear customer:
We would like to congratulate you on the purchase of your new high pressure
cleaner and thank you for your confidence in our products!
Your choice has fallen on an absolute quality product!
Kränzle high pressure cleaners are characterized by their convenient and
compact design as well as their high suitability for everyday use.
Highest precision and dimensional accuracy in addition to a technology
package consisting of a multitude of details mark the difference when it comes
to performance, safety and durability.
In order to facilitate handling of the K 1050 P the following pages are intended
to further explain its use.
2
Contents
Contents ................................................................................. 3
Warranty ................................................................................26
Notes ..................................................................................... 27
3
Description of high pressure cleaner
Design
The K 1050 P high pressure cleaner is a portable machine with an advanced
arrangement system. Please see construction scheme for more details.
9 5 Pump outleet
8 On/Off switch
9 Cable reel
12 11 Gun holder
12 HP hose
4
Description of high pressure cleaner
Hochdruckreiniger
K 1050 P
4. Operating manual
Vor Inbetriebnahme Sicherheitshinweise
lesen und beachten!
Für späteren Gebrauch oder Nachbesitzer
Optional:
Art.No.: 42.403-03
Dirtkiller lance with stainless steel
pipe and plug-in nipple
5
Explanatory symbols
Warning!
Failure to observe this note may result in serious injuries!
6
General rules
Range of application
Use machines for cleaning tasks with high pressure water jet and detergents or with
high pressure water jet without detergents only.
The high pressure cleaner is designed for use in private environment only.
Inspections
The machine must be inspected according to the “Guidelines for Liquid Spray
Devices” at least once every 12 months by a qualified person, to ensure that
continued safe operation is guaranteed. The results of the inspection are to be
recorded in writing. This may be done in any form.
Accident prevention
The machine is designed for accidents to be impossible if used correctly. The
operator is to be notified of the risk of injury from hot machine parts and the
high pressure water jet. The “Guidelines for Liquid Spray Devices” must be
complied with.
Oil leakage
If oil leaks contact your nearest after-sales service (dealer) at once.
Failure to observe this instruction may cause damage to the environment
and/or transmission gearbox.
7
Safety precautions
Persons operating the machine should wear the necessary protective clothing,
i.e. waterproof clothing, rubber boots, safety goggles, headwear etc. It is prohibited
to use the machine in close vicinity to people lacking suitable protective clothing!
Never spray liquids containing solvents like varnish solvents, petrol, oil or
similar liquid!
Due to the high pressure jet, damage may occur on the objects to be cleaned,
e.g. car tires; therefore, a minimum distance of 30 cm is to be kept.
Prior to putting the high pressure cleaners into operation, check its components
(HP hose, power supply cables, safety trigger gun) for any damage. Replace defect
or damaged components!
The high pressure cleaner is to be properly used. The user is required to adhere
to local requirements and to watch out for any persons in the danger zone!
8
Safety notes - This is prohibited!
9
Safety notes - This is prohibited!
10
Functional details
A minimum water quantity of 7.5 l/min is needed for the high pressure cleaner
to operate.
If the metered quantity of water is too small, you have to use a different
water connection, guaranteeing the necessary output.
Lack of water leads to an accelerated wear of the joints (guarantee void).
Never let the pump run dry for more than 20 seconds.
Water supply
Please pay attention to the regulations of your waterworks company!
In accordance with DIN EN 61770, the machine may not be directly
connected to the public drinking water supply lines. A brief connection
however is permissible according to DVGW (German Association
for Gas and Water Affairs) if a non-return valve with tube ventilator
(Kränzle order no. 41.016 4) is built into the water supply. Once the
water has passed through the non-return valve it is no longer
considered as drinking water. Also indirect connection to the
public drinking water supply lines is permissible by way of free
emission in accordance with EN 61 770; e.g. by using a reservoir
with a float valve. Direct connection to a non-drinking water
supply line is permissible.
11
Functional details
Check the line fusing and have the voltage and the available current
intensity checked by an expert in case of uncertainty.
Electrical connection
The machine is supplied with a 5 meter electrical power cable with plug. The mains
plug must be fitted to a standard grounded socket with a 30 mA residual current
operated device. The socket must be protected with a 16 A fuse on the mains side.
When using an extension cable, this must have an earthed lead which is properly
connected to the socket. The conductors in the extension cable must have a
minimum cross section of 1.5 mm². Plug connections must be of a spray-proof design,
and may not be located on a wet floor. When using a cable drum, always keep the
cable wound as far as possible.
12
Functional details
The trigger gun with safety catch is a safety device. Repairs should
only be performed by qualified persons. Should replacement parts be
required, use only components authorized by the manufacturer.
Prior to putting the machine into operation make sure that all safety
instructions be observed.
13
Functional details
If replacement parts are required, only such parts that are authorized
by the manufacturer may be used. The warranty is automatically void if
spare parts of third-party providers are used! The high pressure hose and
spray device must be connected in a pressure-tight manner
(without leakage).
The high pressure hose may not be driven over, pulled excessively, or twisted.
The hose may under no circumstances be pulled over sharp edges. Defective
high pressure hoses must not be repaired (acc. to DIN 20022) but have to
be replaced by new hoses approved by the manufacturer.
14
Putting into operation
Do not place high pressure cleaner on rough surface because unit tends to
vibrate during operation.
When carrying the high pressure cleaner, make sure to bear in mind the
weight of the machine, see technical data.
Neither set up or operate the K 1050 P in rooms where there is a risk of fire
or explosion nor put it into puddles. Do not use the machine under water.
If, none the less, the machine is operated in a hazardous area,
the applicable safety regulations are to be observed.
15
Putting into operation
16
Putting into operation
17
Putting into operation
9. Connect to circuit.
K 1050 P
230 V ~, 9.6 A, 50 Hz
The socket must be protected with a
16A fuse on the mains side.
18
To shut down the pump
19
Small repairs - do it yourself!
Problem:
No water from nozzle although motor is running.
Cause:
Most likely the nozzle is blocked.
No or very little water from the lance.
Proceeding:
Switch off the cleaner. Pull plug from
the socket. Operate trigger gun with
safety catch several times to decrease the
pressure.
20
Small repairs - do it yourself!
Problem:
Irregular jet from nozzle.
Cause:
Most likely the valves are soiled or sticky.
The water from the lance comes in
squirts. The HP hose vibrates.
Proceeding:
Unscrew all 6 valves, one after the other
(hexagonal brass screws, 3 in a row,
vertically and horizontally)
21
Small repairs - do it yourself!
Problem:
After closing of the trigger gun with safety catch the machine keeps switching
on and off.
Proceeding:
Check connections from the HP cleaner to
the high pressure hose and from the hose
to the trigger gun and also the connecti-
on between lance and trigger gun for
tightness.
22
Small repairs - do it yourself!
Problem:
After closing of the trigger gun with safety catch the machine keeps switching
on and off.
Proceeding:
Switch off the HP cleaner and pull plug from
socket. Stop water supply. Unscrew pump
outlet.
23
EC declaration of conformity
technical specifications available from: Fa. Josef Kränzle GmbH & Co. KG
Manfred Bauer
Rudolf-Diesel-Str. 20, 89257 Illertissen
24
Wiring diagram
Capacitor 35 µF
P
Clamp
P2
N
Hi Ha P1
L1
Motor over
temperature-switch
PE
25
Warranty
Warranty
With regard to legal warranty claims, the limitation periods of the respective
countries shall apply.
In the event of any warranty claims, please have your accessories and purchase
voucher ready before contacting your local dealer or the nearest authorized
customer service point, which you can also find in the internet under
www.kraenzle.com .
The high pressure cleaner is designed for private purposes only; no warranty
shall be provided in case of industrial use.
Pressure gauge, nozzle, valves, sleeves, high pressure hose and spray equipment
are wear parts and are not covered by the Warranty obligation.
26
Notes
27
Spare parts list complete assembly
40
41
30
42
10
11 3
14
13
28
K 1050 P
29
Spare parts list motor
14
27 41
25
19
26
18
22
21
12
15 15
13
28
29
30
11
24
6 7
9 4
8
10
5
17
1
30
K 1050 P
31
Spare parts list transmission
9
14
6 7
5
4
3 8
13
10
32
K 1050 P
Oil change
If oil needs to be changed during repair, the unit is to turned into horizontal
position with its head upside down prior to unscrewing the drain plug over a
container. The oil is to be captured in a container and subsequently properly
disposed of. Then screw oil plug back on again over a container. Use small
funnel when refilling with fresh oil.
Fresh oil: 0.1 l - Kränzle Gear Oil (40.092 2) or W 15/40.
33
Spare parts list pressure switch
13
15
12
11
14
50
51
34 35
34
K 1050 P
35
Spare parts list valve housing
19
19.1
7
5 6 10
9
61 8
10
60
3
4
2
40
18
36
K 1050 P
37
Spare parts list gun with lance
2
6
10
38
Spare parts list
Dirtkiller with lance (optional)
1
11 20
39
Technische Änderungen und Irrtümer vorbehalten.
Ingrid Kränzle GmbH
Made