EMC Test Report - Sample

This report summarizes emission and immunity testing conducted on various Vecow industrial computer models to verify compliance with EN 50155 and EN 50121-3-2 standards. Emission tests included conducted emissions and radiated emissions from enclosure ports. Immunity tests included electrostatic discharge, radiated electromagnetic fields, electrical fast transients, and surge immunity. The report provides test configuration details and results for each test.

Uploaded by

abhishek_modem
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
380 views56 pages

EMC Test Report - Sample

This report summarizes emission and immunity testing conducted on various Vecow industrial computer models to verify compliance with EN 50155 and EN 50121-3-2 standards. Emission tests included conducted emissions and radiated emissions from enclosure ports. Immunity tests included electrostatic discharge, radiated electromagnetic fields, electrical fast transients, and surge immunity. The report provides test configuration details and results for each test.

Uploaded by

abhishek_modem
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 56

CE EMC TEST REPORT

(EN 50155 & EN 50121-3-2)

REPORT NO.: CE141111C02-1


TEST MODEL: SPC-2845
SERIES MODEL: Vecow SPC Series, SPC-2145, SPC-2845-W4,
SPC-2845X, SPC-2845R, SPC-2845D,
SPC-XXXXXXXXXX ("X" can be 0-9, A-Z or blank for
marketing purpose)
RECEIVED: Nov. 11, 2014
TESTED: Nov. 20, 2014 ~ Jan. 07, 2015
ISSUED: Jan. 09, 2015

APPLICANT: Vecow Co., Ltd.


ADDRESS: 12F., No. 111, Zhongcheng Rd., Tucheng Dist., New
Taipei City 23674 Taiwan (R. O. C.)

ISSUED BY: Bureau Veritas Consumer Products Services (H.K.)


Ltd., Taoyuan Branch
LAB ADDRESS: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New
Taipei City, Taiwan, R.O.C.
TEST LOCATION: No. 19, Hwa Ya 2nd Rd, Wen Hwa Tsuen, Kwei Shan
Hsiang, Taoyuan Hsien 333, Taiwan, R.O.C.

This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark,
is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The
results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or
any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof
based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or
omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to
raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the
tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into
account to declare the compliance or non-compliance to the specification.
The report must not be used by the client to claim product certification, approval, or endorsement by any government agencies.

Report No.: CE141111C02-1 1 of 56 Report Format Version 5.0.4


Table of Contents
RELEASE CONTROL RECORD .............................................................................................. 4
1 CERTIFICATION .......................................................................................................... 5
2 SUMMARY OF TEST RESULTS .................................................................................. 6
2.1 MEASUREMENT UNCERTAINTY ............................................................................... 6
3 GENERAL INFORMATION ........................................................................................... 7
3.1 GENERAL DESCRIPTION OF EUT ............................................................................. 7
3.2 DESCRIPTION OF TEST MODES ............................................................................... 8
3.3 GENERAL DESCRIPTION OF THE APPLIED STANDARD ........................................ 8
3.4 DESCRIPTION OF SUPPORT UNITS ......................................................................... 9
3.5 CONFIGURATION OF SYSTEM UNDER TEST ........................................................ 11
4 EMISSION TEST ........................................................................................................ 16
4.1 CONDUCTED EMISSION MEASUREMENT ............................................................. 16
4.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT........................................... 16
4.1.2 TEST INSTRUMENTS ............................................................................................... 17
4.1.3 TEST PROCEDURE .................................................................................................. 17
4.1.4 DEVIATION FROM TEST STANDARD ...................................................................... 17
4.1.5 TEST SETUP ............................................................................................................. 18
4.1.6 EUT OPERATING CONDITIONS ............................................................................... 18
4.1.7 TEST RESULTS ......................................................................................................... 19
4.2 RADIATED EMISSION MEASUREMENT FOR ENCLOSURE PORT ....................... 21
4.2.1 LIMITS OF ENCLOSURE PORT ................................................................................ 21
4.2.2 TEST INSTRUMENTS ............................................................................................... 22
4.2.3 TEST PROCEDURE .................................................................................................. 23
4.2.4 DEVIATION FROM TEST STANDARD ...................................................................... 23
4.2.5 TEST SETUP ............................................................................................................. 24
4.2.6 EUT OPERATING CONDITIONS ............................................................................... 24
4.2.7 TEST RESULTS ......................................................................................................... 25
5 IMMUNITY TEST ........................................................................................................ 27
5.1 GENERAL DESCRIPTION ......................................................................................... 27
5.2 GENERAL PERFORMANCE CRITERIA DESCRIPTION .......................................... 28
5.3 EUT OPERATING CONDITION ................................................................................. 28
5.4 ELECTROSTATIC DISCHARGE IMMUNITY TEST (ESD) ........................................ 29
5.4.1 TEST SPECIFICATION .............................................................................................. 29
5.4.2 TEST INSTRUMENTS ............................................................................................... 29
5.4.3 TEST PROCEDURE .................................................................................................. 30
5.4.4 DEVIATION FROM TEST STANDARD ...................................................................... 31
5.4.5 TEST SETUP ............................................................................................................. 31
5.4.6 TEST RESULTS ......................................................................................................... 32
5.5 RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMNITY TEST
(RS) ............................................................................................................................ 36

Report No.: CE141111C02-1 2 of 56 Report Format Version 5.0.4


5.5.1 TEST SPECIFICATION .............................................................................................. 36
5.5.2 TEST INSTRUMENTS ............................................................................................... 36
5.5.3 TEST PROCEDURE .................................................................................................. 37
5.5.4 DEVIATION FROM TEST STANDARD ...................................................................... 37
5.5.5 TEST SETUP ............................................................................................................. 37
5.5.6 TEST RESULTS ......................................................................................................... 38
5.6 ELECTRICAL FAST TRANSIENT (EFT) .................................................................... 39
5.6.1 TEST SPECIFICATION .............................................................................................. 39
5.6.2 TEST INSTRUMENT .................................................................................................. 39
5.6.3 TEST PROCEDURE .................................................................................................. 39
5.6.4 DEVIATION FROM TEST STANDARD ...................................................................... 40
5.6.5 TEST SETUP ............................................................................................................. 40
5.6.6 TEST RESULTS ......................................................................................................... 41
5.7 SURGE IMMUNITY .................................................................................................... 42
5.7.1 TEST SPECIFICATION .............................................................................................. 42
5.7.2 TEST INSTRUMENT .................................................................................................. 42
5.7.3 TEST PROCEDURE .................................................................................................. 43
5.7.4 DEVIATION FROM TEST STANDARD ...................................................................... 43
5.7.5 TEST SETUP ............................................................................................................. 44
5.7.6 TEST RESULTS ......................................................................................................... 44
5.8 CONDUCTED RADIO FREQUENCY DISTURBANCES (CS) ................................... 45
5.8.1 TEST SPECIFICATION .............................................................................................. 45
5.8.2 TEST INSTRUMENT .................................................................................................. 46
5.8.3 TEST PROCEDURE .................................................................................................. 47
5.8.4 DEVIATION FROM TEST STANDARD ...................................................................... 47
5.8.5 TEST SETUP ............................................................................................................. 48
5.8.6 TEST RESULTS ......................................................................................................... 49
6 PHOTOGRAPHS OF THE TEST CONFIGURATION................................................. 50
7 INFORMATION ON THE TESTING LABORATORIES ............................................... 56

Report No.: CE141111C02-1 3 of 56 Report Format Version 5.0.4


RELEASE CONTROL RECORD

ISSUE NO. REASON FOR CHANGE DATE ISSUED


CE141111C02-1 Original release. Jan. 09, 2015

Report No.: CE141111C02-1 4 of 56 Report Format Version 5.0.4


1 CERTIFICATION

PRODUCT: Ultra-Compact Embedded System


BRAND: Vecow
TEST MODEL: SPC-2845
SERIES MODEL: Vecow SPC Series, SPC-2145, SPC-2845-W4, SPC-2845X,
SPC-2845R, SPC-2845D, SPC-XXXXXXXXXX ("X" can be 0-9,
A-Z or blank for marketing purpose)
APPLICANT: Vecow Co., Ltd.
TESTED: Nov. 20, 2014 ~ Jan. 07, 2015
TEST SAMPLE: ENGINEERING SAMPLE
STANDARD: EN 50155:2007 +AC:2010 +AC:2012, Clause 12.2.7 & 12.2.8
EN 50121-3-2:2006 +AC:2008
EN 55011:2009 +A1:2010
EN 61000-4-2:2009
EN 61000-4-3:2006 +A1:2008 +A2:2010
EN 61000-4-4:2012
EN 61000-4-5:2006
EN 61000-4-6:2014

The above equipment (model: SPC-2845) has been tested by Bureau Veritas
Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found
compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true
and accurate accounts of the measurements of the sample’s EMC characteristics
under the conditions specified in this report.

PREPARED BY : , DATE : Jan. 09, 2015


Suntee Liu / Specialist

APPROVED BY : , DATE : Jan. 09, 2015


Ken Liu / Senior Manager

Report No.: CE141111C02-1 5 of 56 Report Format Version 5.0.4


2 SUMMARY OF TEST RESULTS
The EUT has been tested according to the following specifications.
EMISSIONS
Standard Test Type Result Remarks
Meet the requirement of limit.
Auxiliary a.c. or d.c. power port PASS Minimum passing margin is
EN 55011:2009 -47.05dB at 0.15000MHz.
+A1:2010 Meet the requirement of limit.
Enclosure port PASS Minimum passing margin is
-5.07dB at 770.00MHz.

IMMUNITY
Standard Test Type Result Remarks
Electrostatic discharge Meets the requirements of
EN 61000-4-2:2009 PASS
immunity test Performance Criterion B
Radiated, radio-frequency,
EN 61000-4-3:2006 Meets the requirements of
electromagnetic field immunity PASS
+A1:2008 +A2:2010 Performance Criterion A
test
Meets the requirements of
Electrical fast transient / burst
EN 61000-4-4:2012 PASS Performance Criterion A
immunity test
(Judged by manufacturer)
Meets the requirements of
EN 61000-4-5:2006 Surge immunity test PASS
Performance Criterion A
Immunity to conducted
Meets the requirements of
EN 61000-4-6:2014 disturbances, induced by PASS
Performance Criterion A
radio-frequency fields

2.1 MEASUREMENT UNCERTAINTY

Where relevant, the following measurement uncertainty levels have been estimated
for tests performed on the EUT as specified in CISPR 16-4-2:

This uncertainty represents an expanded uncertainty expressed at approximately the


95% confidence level using a coverage factor of k=2.

Measurement Frequency Uncertainty


Conducted emission 150kHz ~ 30MHz 2.44dB
Radiated emission 30MHz ~ 1GHz 4.70dB

The listed uncertainties are the worst case uncertainty for the entire range of
measurement. Please note that the uncertainty values are provided for informational
purposes only and are not used in determining the PASS/FAIL results.

Report No.: CE141111C02-1 6 of 56 Report Format Version 5.0.4


3 GENERAL INFORMATION

3.1 GENERAL DESCRIPTION OF EUT

PRODUCT Ultra-Compact Embedded System


TEST MODEL SPC-2845
Vecow SPC Series, SPC-2145, SPC-2845-W4,
SPC-2845X, SPC-2845R, SPC-2845D,
SERIES MODEL
SPC-XXXXXXXXXX ("X" can be 0-9, A-Z or blank for
marketing purpose)
OPERATING SOFTWARE Win 7
POWER SUPPLY 12Vdc (adapter)
DATA CABLE NA
ACCESSORY DEVICE Adapter

NOTE:
1. The EUT uses following adapter.
Brand Seasonic
Model SSA-0601D-12
Input Power 100-240Vac, 2A, 50/60Hz
Output Power +12Vdc, 5A, 60W Max
Power Line 1m DC cable with 1 core attached on adapter
2. All models are electrically identical, different model names are for marketing purpose. Model
SPC-2845 is the representative for final test.
Brand Model
Vecow SPC Series
SPC-2845
SPC-2145
SPC-2845-W4
Vecow
SPC-2845X
SPC-2845R
SPC-2845D
SPC-XXXXXXXXXX (“X” can be 0-9, A-Z or blank for marketing purpose)
3. The above EUT information is declared by manufacturer and for more detailed feature description,
please refer to the manufacturer's specifications or user's manual.

Report No.: CE141111C02-1 7 of 56 Report Format Version 5.0.4


3.2 DESCRIPTION OF TEST MODES

Test modes are presented in the report as below.


Mode Test Condition
Conducted emission test
- DVI 1920*1200@60Hz, LAN 1 1Gbps, LAN 2 1Gbps
Radiated emission test
- DVI 1920*1200@60Hz, LAN 1 1Gbps, LAN 2 1Gbps
Immunity tests
- DVI 1920*1200@60Hz, LAN 1 1Gbps, LAN 2 1Gbps

3.3 GENERAL DESCRIPTION OF THE APPLIED STANDARD

The EUT is a kind of railway application equipments, and according to the


specification of the EUT declared by manufacturer, it must comply with the
requirements of the following standards:

EN 50155:2007 +AC:2010 +AC:2012, Clause 12.2.7 & 12.2.8


EN 50121-3-2:2006 +AC:2008
EN 55011:2009 +A1:2010
EN 61000-4-2:2009
EN 61000-4-3:2006 +A1:2008 +A2:2010
EN 61000-4-4:2012
EN 61000-4-5:2006
EN 61000-4-6:2014

Note: The above EN basic standards are applied with latest version if manufacturer
has no special requirement.

All tests have been performed and recorded as per the above standards.

Report No.: CE141111C02-1 8 of 56 Report Format Version 5.0.4


3.4 DESCRIPTION OF SUPPORT UNITS

The EUT has been tested as an independent unit together with other necessary
accessories or support units. The following support units or accessories were used
to form a representative test configuration during the tests.

Emission tests:
ID Product Brand Model No. Serial No. FCC ID Remarks
CN082WXD-72872-
A. 24" LCD MONITOR DELL U2410 FCC DoC Approved -
0CR-06DL
CN-05V23T-71581-1
B. Keyboard DELL KB4021 FCC DoC Approved -
AK-01Q2-A01
CN-011D3V-71581-
C. MOUSE DELL MS111-P FCC DoC Approved -
1CJ-0195
D. EARPHONE PHILIPS HL145 NA NA -
E. PRINTER EPSON T22 MEEZ070220 FCC DoC Approved -
WDBACY5000AB
F. External Hard Disk WD WX51C12T6215 NA -
L-01
G. MODEM ACEEX 1414V/3 0401008278 IFAXDM1414 -
H. MODEM ACEEX 1414V/3 0401008252 IFAXDM1414 -
I. MODEM ACEEX 1414V/3 0401008241 IFAXDM1414 -
J. MODEM ACEEX 1414V/3 0401008279 IFAXDM1414 -
K. Notebook DELL Latitude E6420 HPFC5Q1 FCC DoC Approved -
W4TYK9CQCJ3K3K
L. Notebook DELL PP02X QDS-BRCM1005-D -
CBRXTRFWYRB
Note:
1. All power cords of the above support units are non-shielded (1.8m).
2. Items K~L acted as communication partners to transfer data.

Shielding
ID Descriptions Qty. Length (m) Cores (Qty.) Remarks
(Yes/No)
1. DVI 1 1.8 Y 2 Provided by manufacturer
2. USB 1 1.8 Y 0 -
3. USB 1 1.8 Y 0 -
4. Earphone 1 1.2 N 0 -
5. USB 1 1.8 Y 0 -
6. USB 1 0.5 Y 0 -
7. RS-232 3 1.2 Y 0 -
8. RS-232 1 1.5 Y 0 -
9. RJ45, Cat5e 2 10 N 0 Only for Radiated emission test
10. RS-232 1 2 Y 0 -
11. RJ45, Cat5e 2 10 Y 0 Only for Conducted emission test
Note: The core(s) is(are) originally attached to the cable(s).

Report No.: CE141111C02-1 9 of 56 Report Format Version 5.0.4


Immunity tests:
ID Product Brand Model No. Serial No. FCC ID Remarks
CN-0YY528-46633-
A. 24" LCD Monitor DELL 2407WFPb FCC DoC Approved -
76I-1E7S
CN-05V23T-71581-1
B. Keyboard DELL KB4021 FCC DoC Approved -
AK-01KZ-A01
CN-011D3V-71581-
C. MOUSE DELL MS111-P FCC DoC Approved -
1CJ-093U
D. Earphone PHILIPS SHM2100U 03 NA -
E. Hard Disk ADATA HV620 1E3620122277 NA -
F. Hard Disk ADATA HV620 1E3620122297 NA -
G. MODEM ACEEX 1414V/3 0401008252 IFAXDM1414 -
H. MODEM ACEEX 1414V/3 0401008253 IFAXDM1414 -
I. MODEM ACEEX 1414V/3 0401008270 IFAXDM1414 -
J. MODEM ACEEX 1414V/3 0401008268 IFAXDM1414 -
K. Notebook Dell E5420 55CD5S1 FCC DoC Approved -
L. Notebook Dell E5420 55CF4S1 FCC DoC Approved -
Note:
1. All power cords of the above support units are non-shielded (1.8m).
2. Items K~L acted as communication partners to transfer data.

Shielding
ID Descriptions Qty. Length (m) Cores (Qty.) Remarks
(Yes/No)
1. DVI 1 1.8 Y 2 Provided by manufacturer
2. USB 1 1.8 Y 0 -
3. USB 1 1.8 Y 0 -
4. Earphone 1 1.9 N 0 -
5. USB 1 0.3 Y 0 -
6. USB 1 0.3 Y 0 -
7. RS-232 4 1.6 Y 0 -
8. RJ45, Cat5e 2 10 N 0 Only for ESD, Surge tests
9. RJ45, Cat5e 2 10 Y 0 Only for RS, EFT, CS tests
10. Ground 1 1.8 Y 0 Only for RS, EFT tests
Note: The core(s) is(are) originally attached to the cable(s).

Report No.: CE141111C02-1 10 of 56 Report Format Version 5.0.4


3.5 CONFIGURATION OF SYSTEM UNDER TEST

Conducted emission test:

(10)
(1) Console
Monitor (A) DVI
(5)
(2)
USB Printer (E)
Keyboard (B) USB
(6)
(3) USB HDD (F)
Mouse (C) USB
EUT
(7)
(4) RS-232 x3 Modem (G),(H),(I)
Earphone (D) Earphone
(8)
RS-232 Modem (J)

Adapter (EUT) AC

LAN x2

(11)

Remote site

Notebook (K),(L)

Report No.: CE141111C02-1 11 of 56 Report Format Version 5.0.4


Radiated emission test:

(10)
(1) Console
Monitor (A) DVI
(5)
(2)
USB Printer (E)
Keyboard (B) USB
(6)
(3) USB HDD (F)
Mouse (C) USB
EUT
(7)
(4) RS-232 x3 Modem (G),(H),(I)
Earphone (D) Earphone
(8)
RS-232 Modem (J)

Adapter (EUT) AC

LAN x2

(9)

Remote site

Notebook (K),(L)

Report No.: CE141111C02-1 12 of 56 Report Format Version 5.0.4


ESD, Surge tests:

(1)
Monitor (A) DVI
(5)
(2)
USB HDD (E)
Keyboard (B) USB
(6)
(3) USB HDD (F)
Mouse (C) USB
EUT
(7)
(4) RS-232 x4 Modem (G),(H),(I),(J)
Earphone (D) Earphone

Adapter (EUT) AC

LAN x2

(8)

Remote site

Notebook (K),(L)

Report No.: CE141111C02-1 13 of 56 Report Format Version 5.0.4


RS, EFT tests:

(10)
(1)
Monitor (A) DVI
(5)
(2)
USB HDD (E)
Keyboard (B) USB
(6)
(3) USB HDD (F)
Mouse (C) USB
EUT
(7)
(4) RS-232 x4 Modem (G),(H),(I),(J)
Earphone (D) Earphone

Adapter (EUT) AC

LAN x2

(9)

Remote site

Notebook (K),(L)

Report No.: CE141111C02-1 14 of 56 Report Format Version 5.0.4


CS test:

(1)
Monitor (A) DVI
(5)
(2)
USB HDD (E)
Keyboard (B) USB
(6)
(3) USB HDD (F)
Mouse (C) USB
EUT
(7)
(4) RS-232 x4 Modem (G),(H),(I),(J)
Earphone (D) Earphone

Adapter (EUT) AC

LAN x2

(9)

Remote site

Notebook (K),(L)

Report No.: CE141111C02-1 15 of 56 Report Format Version 5.0.4


4 EMISSION TEST

4.1 CONDUCTED EMISSION MEASUREMENT

4.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT

TEST STANDARD: EN50121-3-2

Frequency (MHz) Quasi-peak Remarks

0.009-0.15 No Limit See note 1 & 2


0.15-0.5 99 See note 3, 4 & 5
0.5-30 93 See note 3, 4 & 5

NOTE:
1. At present there are no limits for conducted emissions from 9 kHz to 150 kHz. Limiting conducted
emissions from an apparatus will prevent excessive radiated emissions. Experience in this
technique and the relationship between conducted and radiated emissions is necessary in order to
progress this standard in the future.
2. 230 V AC power outlet ports for public use shall offer a power quality, which is sufficient for the use
of intended equipment like PC and mobile telephone chargers. The harmonic distortion in
differential and common mode shall be limited by a sine-filter to < 5 %. The burst and surge
emissions of the outlet have to be limited to the levels of residential equipment according to EN
61000-6-1. AM radio receivers are not intended to be supplied by these power outlets.
3. Wherever applicable the method defined by EN 55011 is to be used. At present the existing
method of measuring conducted emissions (EN 55011) has limitations in terms of voltage and
current rating of coupling networks. In addition the method of measuring voltage has safety
implications for testing high power systems. Limiting conducted emissions from apparatus
connected to external cable systems will prevent excessive radiated emissions.
4. This requirement refers to the industrial limit values but considering they have been defined to
protect radio and TV sets and as the objective is not the same here, the applicable limit for railway
applications have been relaxed by 20 dB to be more representative of potential problems.
5. This requirement is not applicable to power ports which are connected to other dedicated,
compatible ports.

Report No.: CE141111C02-1 16 of 56 Report Format Version 5.0.4


4.1.2 TEST INSTRUMENTS

Description &
Model No. Serial No. Cal. Date Cal. Due
Manufacturer
Test Receiver
ESCS30 100288 Apr. 24, 2014 Apr. 23, 2015
ROHDE & SCHWARZ
RF signal cable
5D-FB Cable-HYCO2-01 Dec. 27, 2013 Dec. 26, 2014
Woken
LISN
ROHDE & SCHWARZ ESH2-Z5 100100 Dec. 23, 2013 Dec. 22, 2014
(EUT)
LISN
ROHDE & SCHWARZ ESH3-Z5 100312 Jul. 10, 2014 Jul. 09, 2015
(Peripheral)
Software BV ADT_Cond_
NA NA NA
ADT V7.3.7.3

Notes: 1. The calibration interval of the above test instruments is 12 months and the calibrations are
traceable to NML/ROC and NIST/USA.
2. The test was performed in HwaYa Shielded Room 2.
3. The VCCI Site Registration No. is C-2047.

4.1.3 TEST PROCEDURE

a. The EUT was placed 0.4 meters from the conducting wall of the shielded room
with EUT being connected to the power mains through a line impedance
stabilization network (LISN). Other support units were connected to the power
mains through another LISN. The two LISNs provide 50 Ohm/ 50uH of coupling
impedance for the measuring instrument.
b. Both lines of the power mains connected to the EUT were checked for maximum
conducted interference.
c. The frequency range from 150 kHz to 30 MHz was searched. Emission levels
under Limit - 20dB was not recorded.

4.1.4 DEVIATION FROM TEST STANDARD

No deviation.

Report No.: CE141111C02-1 17 of 56 Report Format Version 5.0.4


4.1.5 TEST SETUP

V e r t ic a l G r o u n d
R e f e r e n c e P la n e T e s t R e c e iv e r

EUT
40cm

80cm
L IS N

H o r i z o n ta l G r o u n d
R e f e r e n c e P la n e

N o t e : 1 .S u p p o r t u n its w e r e c o n n e c t e d t o s e c o n d L IS N .
2 .B o t h o f L I S N s ( A M N ) a r e 8 0 c m f r o m E U T a n d a t l e a s t 8 0 c m
f r o m o t h e r u n i ts a n d o t h e r m e ta l p l a n e s

For the actual test configuration, please refer to the related item – Photographs of
the Test Configuration.

4.1.6 EUT OPERATING CONDITIONS

a. EUT sent “H” patterns to monitor and monitor displayed them.


b. EUT sent “H” patterns to printer and printer printed them.
c. EUT sent “H” patterns to modems.
d. EUT performed R/W function with HDD.
e. EUT sent audio signal to earphone.
f. EUT linked with notebooks through LAN.

Report No.: CE141111C02-1 18 of 56 Report Format Version 5.0.4


4.1.7 TEST RESULTS

Detector Function Quasi-Peak (QP) /


Frequency Range 150kHz ~ 30MHz
& Bandwidth Average (AV), 9kHz
Environmental
Input Power 230Vac,50Hz 23℃, 64%RH
Conditions
Tested by Scott Yang Test Date 2014/11/21

Phase Of Power : Line (L)


Frequency Correction Reading Value Emission Level Limit Margin
No Factor (dBuV) (dBuV) (dBuV) (dB)
(MHz) (dB) Q.P. Q.P. Q.P. Q.P.
1 0.15000 0.26 51.69 51.95 99.00 -47.05
2 0.23203 0.28 41.44 41.72 99.00 -57.28
3 0.45859 0.30 31.22 31.52 99.00 -67.48
4 1.73047 0.35 24.10 24.45 93.00 -68.55
5 4.51953 0.44 27.71 28.15 93.00 -64.85
6 22.74609 0.56 37.15 37.71 93.00 -55.29
Remarks:
1. Q.P. and AV. are abbreviations of quasi-peak and average individually.
2. The emission levels of other frequencies were very low against the limit.
3. Margin value = Emission level – Limit value
4. Correction factor = Insertion loss + Cable loss
5. Emission Level = Correction Factor + Reading Value

Report No.: CE141111C02-1 19 of 56 Report Format Version 5.0.4


Detector Function Quasi-Peak (QP) /
Frequency Range 150kHz ~ 30MHz
& Bandwidth Average (AV), 9kHz
Environmental
Input Power 230Vac,50Hz 23℃, 64%RH
Conditions
Tested by Scott Yang Test Date 2014/11/21

Phase Of Power : Neutral (N)


Frequency Correction Reading Value Emission Level Limit Margin
No Factor (dBuV) (dBuV) (dBuV) (dB)
(MHz) (dB) Q.P. Q.P. Q.P. Q.P.
1 0.15391 0.27 51.24 51.51 99.00 -47.49
2 0.20469 0.28 44.24 44.52 99.00 -54.48
3 0.47813 0.31 29.45 29.76 99.00 -69.24
4 1.38672 0.35 24.68 25.03 93.00 -67.97
5 4.70313 0.45 31.57 32.02 93.00 -60.98
6 22.33203 0.61 35.93 36.54 93.00 -56.46
Remarks:
1. Q.P. and AV. are abbreviations of quasi-peak and average individually.
2. The emission levels of other frequencies were very low against the limit.
3. Margin value = Emission level – Limit value
4. Correction factor = Insertion loss + Cable loss
5. Emission Level = Correction Factor + Reading Value

Report No.: CE141111C02-1 20 of 56 Report Format Version 5.0.4


4.2 RADIATED EMISSION MEASUREMENT FOR ENCLOSURE PORT

4.2.1 LIMITS OF ENCLOSURE PORT

TEST STANDARD: EN 50121-3-2

Basic
Port Test Specification Standard Remarks
Test set-up
30 MHz ~ 230 MHz 40 dBμV/m quasi-peak Note 1 & 2
Enclosure EN 55011
230 MHz ~ 1 GHz 47 dBμV/m quasi-peak Note 1 & 2

NOTE: 1. Measurement distance is 10 m. A measurement distance of 3 m may be used with the limit
increased by 10 dB.
2. Traction converters and auxiliary converters over 50 kVA need not be tested individually
but when the vehicle is tested as a whole in accordance with EN 50121-3-1.

Report No.: CE141111C02-1 21 of 56 Report Format Version 5.0.4


4.2.2 TEST INSTRUMENTS

Description &
Model No. Serial No. Cal. Date Cal. Due
Manufacturer
Test Receiver
ROHDE & SCHWARZ ESR-7 101240 Sep. 29, 2014 Sep. 28, 2015
(V)
Test Receiver
ROHDE & SCHWARZ ESR-7 101264 Nov. 29, 2013 Nov. 28, 2014
(H)
BILOG Antenna
VULB9168 9168-148 Feb. 25, 2014 Feb. 24, 2015
SCHWARZBECK (V)
BILOG Antenna
VULB9168 9168-149 Feb. 25, 2014 Feb. 24, 2015
SCHWARZBECK (H)
Preamplifier
8447D 2944A10636 Oct. 18, 2014 Oct. 17, 2015
Agilent (V)
Preamplifier
8447D 2944A10637 Oct. 18, 2014 Oct. 17, 2015
Agilent (H)
Preamplifier
8449B 3008A01959 Oct. 18, 2014 Oct. 17, 2015
Agilent
RF signal cable
8D-FB Cable-CH(H)-01 Oct. 25, 2014 Oct. 24, 2015
Woken (V)
RF signal cable
8D-FB Cable-CH(V)-01 Oct. 25, 2014 Oct. 24, 2015
Woken (H)
Software BV ADT_Radiated_
NA NA NA
BV ADT V 8.7.07
Antenna Tower (V) MFA-440 9707 NA NA
Antenna Tower (H) MFA-440 970705 NA NA
Turn Table DS430 50303 NA NA
Controller (V) MF7802 074 NA NA
Controller (H) MF7802 08093 NA NA

Notes: 1. The calibration interval of the above test instruments is 12 months and the
calibrations are traceable to NML/ROC and NIST/USA.
2. The test was performed in HwaYa Chamber 1.
3. The FCC Site Registration No. is 477732.
4. The IC Site Registration No. is IC 7450F-1.
5. The VCCI Site Registration No. is R-1893.

Report No.: CE141111C02-1 22 of 56 Report Format Version 5.0.4


4.2.3 TEST PROCEDURE

a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at
a 10 meter semi-anechoic chamber room. The table was rotated 360 degrees to
determine the position of the highest radiation.
b. The EUT was set 10 meters away from the interference-receiving antenna, which
was mounted on the top of a variable-height antenna tower.
c. The height of antenna is varied from 1 meter to 4 meters above the ground to
determine the maximum value of the field strength. Both horizontal and vertical
polarizations of the antenna are set to make the measurement.
d. For each suspected emission, the EUT was arranged to its worst case and then
the antenna was tuned to heights from 1 meter to 4 meters and the rotatable table
was turned from 0 degrees to 360 degrees to find the maximum reading.
e. The test-receiver system was set to quasi-peak detect function and specified
bandwidth with maximum hold mode when the test frequency is below 1GHz.
NOTE: The resolution bandwidth of test receiver/spectrum analyzer is 120kHz for Quasi-Peak (QP)
detection at frequency below 1GHz.

4.2.4 DEVIATION FROM TEST STANDARD

No deviation.

Report No.: CE141111C02-1 23 of 56 Report Format Version 5.0.4


4.2.5 TEST SETUP

For the actual test configuration, please refer to the related item – Photographs of
the Test Configuration.

4.2.6 EUT OPERATING CONDITIONS

Same as 4.1.6.

Report No.: CE141111C02-1 24 of 56 Report Format Version 5.0.4


4.2.7 TEST RESULTS

Detector Function &


Frequency Range 30MHz ~ 1GHz Quasi-Peak (QP), 120kHz
Bandwidth
Environmental
Input Power 230Vac, 50Hz 23℃, 64%RH
Conditions
Tested by Scott Yang Test Date 2014/11/20

Antenna Polarity & Test Distance : Horizontal at 10 m


Emission Antenna Table Raw Correction
Frequency Limit Margin
No Level Height Angle Value Factor
(MHz) (dBuV/m) (dB)
(dBuV/m) (m) (Degree) (dBuV) (dB/m)
1 112.84 26.49 QP 40.00 -13.51 4.00 H 132 43.54 -17.05
2 160.91 27.49 QP 40.00 -12.51 3.50 H 35 41.23 -13.74
3 214.41 29.53 QP 40.00 -10.47 4.00 H 332 45.58 -16.05
4 248.26 30.49 QP 47.00 -16.51 3.00 H 134 44.47 -13.98
5 410.36 32.23 QP 47.00 -14.77 2.50 H 322 41.23 -9.00
6 770.00 38.46 QP 47.00 -8.54 4.00 H 270 40.08 -1.62
Remarks:
1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
2. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB)
– Pre-Amplifier Factor (dB)
3. The other emission levels were very low against the limit.
4. Margin value = Emission level – Limit value

Report No.: CE141111C02-1 25 of 56 Report Format Version 5.0.4


Detector Function &
Frequency Range 30MHz ~ 1GHz Quasi-Peak (QP), 120kHz
Bandwidth
Environmental
Input Power 230Vac, 50Hz 23℃, 64%RH
Conditions
Tested by Scott Yang Test Date 2014/11/20

Antenna Polarity & Test Distance : Vertical at 10 m


Emission Antenna Table Raw Correction
Frequency Limit Margin
No Level Height Angle Value Factor
(MHz) (dBuV/m) (dB)
(dBuV/m) (m) (Degree) (dBuV) (dB/m)
1 38.44 31.79 QP 40.00 -8.21 1.50 V 60 46.60 -14.81
2 67.69 31.55 QP 40.00 -8.45 2.00 V 72 47.16 -15.61
3 149.46 30.52 QP 40.00 -9.48 1.00 V 296 44.00 -13.48
4 198.74 30.41 QP 40.00 -9.59 1.00 V 261 46.29 -15.88
5 369.08 32.51 QP 47.00 -14.49 1.00 V 119 41.80 -9.29
6 770.00 41.93 QP 47.00 -5.07 2.50 V 307 42.91 -0.98
Remarks:
1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
2. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB)
– Pre-Amplifier Factor (dB)
3. The other emission levels were very low against the limit.
4. Margin value = Emission level – Limit value

Report No.: CE141111C02-1 26 of 56 Report Format Version 5.0.4


5 IMMUNITY TEST

5.1 GENERAL DESCRIPTION

Product standard EN 50121-3-2


EN 61000-4-2 Electrostatic Discharge – ESD:
8 kV air discharge,
6 kV contact discharge,
Performance Criterion B
EN 61000-4-3 Radio-Frequency Electromagnetic Field Susceptibility
Test – RS:
80-1000 MHz, 20 V/m, 80% AM (1 kHz),1
800-1000 MHz, 20 V/m, 80% AM (1 kHz),
1400-2100 MHz, 10 V/m, 80% AM (1 kHz),
Basic standard, 2100-2500 MHz, 5 V/m, 80% AM (1 kHz),
Specification Performance Criterion A
requirement and EN 61000-4-4 Electrical Fast Transient/Burst - EFT,
Performance criteria Power line: 2kV, Signal line: 2kV,
Performance Criterion A
EN 61000-4-5 Surge Immunity Test:
1.2/50 us Open Circuit Voltage,
Power Line: line to line 1 kV,
line to ground 2 kV
Performance Criterion B
EN 61000-4-6 Conducted Radio Frequency Disturbances Test – CS:
0.15 ~ 80 MHz, 10Vrms, 80% AM, 1kHz,
Performance Criterion A
NOTE 1: This limit applies to equipment mounted in the passenger compartments, drivers cab or
external to the rolling stock (roof, underframe). For equipment mounted in all other areas
a severity level of 10 V/m may be used.

Report No.: CE141111C02-1 27 of 56 Report Format Version 5.0.4


5.2 GENERAL PERFORMANCE CRITERIA DESCRIPTION

According to EN 50121-1 standard, the following describes the general performance


criteria:

A functional description and a definition of performance criteria, during or as a


consequence of the EMC testing, shall be provided by the manufacturer and noted
in the test report, based on the following criteria:
The apparatus shall continue to operate as intended during and after the
test. No degradation of performance or loss of function is allowed below a
performance level specified by the manufacturer, when the apparatus is
used as intended. The performance level may be replaced by a
CRITERION A permissible loss of performance. If the minimum performance level or the
permissible performance loss is not specified by the manufacturer, either
of these may be derived from the product description and documentation,
and from what the user may reasonably expect from the apparatus if used
as intended.
The apparatus shall continue to operate as intended after the test. No
degradation of performance or loss of function is allowed below a
performance level specified by the manufacturer, when the apparatus is
used as intended. The performance level may be replaced by a
permissible loss of performance. During the test, degradation of
CRITERION B performance is however allowed. No change of actual operating state or
stored data is allowed. If the minimum performance level or the
permissible performance loss is not specified by the manufacturer, either
of these may be derived from the product description and documentation,
and from what the user may reasonably expect from the apparatus if used
as intended.
Temporary loss of function is allowed, provided the function is
CRITERION C
self-recoverable or can be restored by the operation of the controls.

5.3 EUT OPERATING CONDITION

a. EUT sent “H” patterns to monitor and monitor displayed them.


b. EUT sent “H” patterns to modems.
c. EUT performed R/W function with HDDs.
d. EUT sent audio signal to earphone.
e. EUT linked with notebooks through LAN.

Report No.: CE141111C02-1 28 of 56 Report Format Version 5.0.4


5.4 ELECTROSTATIC DISCHARGE IMMUNITY TEST (ESD)

5.4.1 TEST SPECIFICATION

Basic Standard: EN 61000-4-2


Discharge Impedance: 330 ohm / 150 pF
Discharge Voltage: Air Discharge: 2, 4, 8 kV (Direct)
Contact Discharge: 2, 4, 6 kV (Direct/Indirect)
Polarity: Positive & Negative
Number of Discharge: Minimum 20 times at each test point
Discharge Mode: Single Discharge
Discharge Period: 1 second minimum

5.4.2 TEST INSTRUMENTS

Description & Manufacturer Model No. Serial No. Cal. Date Cal. Due
Electronic Discharge
Simulator MZ-151EC 0310225 Jun. 09, 2014 Jun. 08, 2015
(KeyTek)

Notes: 1. The test was performed in Hwa Ya ESD Room 4.


2. The calibration interval of the above test instruments is 12 months and the calibrations are
traceable to NML/ROC and NIST/USA.

Report No.: CE141111C02-1 29 of 56 Report Format Version 5.0.4


5.4.3 TEST PROCEDURE

The discharges shall be applied in two ways:


a. Contact discharges to the conductive surfaces and coupling planes:
The EUT shall be exposed to at least 200 discharges, 100 each at negative and
positive polarity, at a minimum of four test points. One of the test points shall be
subjected to at least 50 indirect discharges to the center of the front edge of the
horizontal coupling plane. The remaining three test points shall each receive at
least 50 direct contact discharges. If no direct contact test points are available,
then at least 200 indirect discharges shall be applied in the indirect mode. Test
shall be performed at a maximum repetition rate of one discharge per second.
b. Air discharges at slots and apertures and insulating surfaces:
On those parts of the EUT where it is not possible to perform contact discharge
testing, the equipment should be investigated to identify user accessible points
where breakdown may occur. Such points are tested using the air discharge
method. This investigation should be restricted to those area normally handled by
the user. A minimum of 10 single air discharges shall be applied to the selected
test point for each such area.
The basic test procedure was in accordance with EN 61000-4-2:
a. Electrostatic discharges were applied only to those points and surfaces of the
EUT that are accessible to users during normal operation.
b. The test was performed with at least ten single discharges on the pre-selected
points in the most sensitive polarity.
c. The time interval between two successive single discharges was at least 1
second.
d. The ESD generator was held perpendicularly to the surface to which the
discharge was applied and the return cable was at least 0.2 meters from the EUT.
e. Contact discharges were applied to the non-insulating coating, with the pointed tip
of the generator penetrating the coating and contacting the conducting substrate.
f. Air discharges were applied with the round discharge tip of the discharge
electrode approaching the EUT as fast as possible (without causing mechanical
damage) to touch the EUT. After each discharge, the ESD generator was
removed from the EUT and re-triggered for a new single discharge. The test was
repeated until all discharges were complete.
g. At least ten single discharges (in the most sensitive polarity) were applied to the
Horizontal Coupling Plane at points on each side of the EUT. The ESD generator
was positioned horizontally at a distance of 0.1 meters from the EUT with the
discharge electrode touching the HCP.
h. At least ten single discharges (in the most sensitive polarity) were applied to the
center of one vertical edge of the Vertical Coupling Plane in sufficiently different
positions that the four faces of the EUT were completely illuminated. The VCP
(dimensions 0.5m x 0.5m) was placed vertically to and 0.1 meters from the EUT.

Report No.: CE141111C02-1 30 of 56 Report Format Version 5.0.4


5.4.4 DEVIATION FROM TEST STANDARD

No deviation.

5.4.5 TEST SETUP

For the actual test configuration, please refer to the related item – Photographs of
the Test Configuration.

NOTE:
TABLE-TOP EQUIPMENT
The configuration consisted of a wooden table 0.8 meters high standing on the Ground Reference
Plane. The GRP consisted of a sheet of aluminum at least 0.25mm thick, and 2.5 meters square
connected to the protective grounding system. A Horizontal Coupling Plane (1.6m x 0.8m) was placed
on the table and attached to the GRP by means of a cable with 940k total impedance. The
equipment under test, was installed in a representative system as described in section 7 of EN
61000-4-2, and its cables were placed on the HCP and isolated by an insulating support of 0.5mm
thickness. A distance of 1-meter minimum was provided between the EUT and the walls of the
laboratory and any other metallic structure.

Report No.: CE141111C02-1 31 of 56 Report Format Version 5.0.4


5.4.6 TEST RESULTS

Input Power 230 Vac, 50 Hz Test Date 2014/11/27


22 °C, 53% RH
Environmental Conditions Tested by Leo Chan
988 mbar

Test Results of Direct Application


Discharge Polarity Contact Performance
Test Point Air Discharge
Level (kV) (+/-) Discharge Criterion
2, 4 +/- 1-7 Note 1 NA A
6 +/- 1-7 Note 2 NA B
2 +/- 8 Note 1 NA A
4, 6 +/- 8 Note 3 NA B
2, 4, 8 +/- 9 NA Note 1 A
2, 4 +/- 10-11 NA Note 1 A
8 +/- 10-11 NA Note 2 B
2, 4 +/- 12 NA Note 1 A
8 +/- 12 NA Note 3 B
Description of test points of direct application: Please refer to following page for representative mark
only.

Test Results of Indirect Application


Discharge Polarity Horizontal Vertical Coupling Performance
Test Point
Level (kV) (+/-) Coupling Plane Plane Criterion
2, 4, 6 +/- Four Sides Note 1 Note 1 A
Description of test points of indirect application:

1. Front side 2. Rear side 3. Right side 4. Left side

Note: 1. The EUT function was correct during the test.


2. The EUT USB HDD R/W function held during the test, but could self-recover after the test.
3. The LAN PING had request time out message during the test, but could self-recover after the
test.

Report No.: CE141111C02-1 32 of 56 Report Format Version 5.0.4


Description of Test Points

10

Report No.: CE141111C02-1 33 of 56 Report Format Version 5.0.4


6

11

12

Report No.: CE141111C02-1 34 of 56 Report Format Version 5.0.4


7

Report No.: CE141111C02-1 35 of 56 Report Format Version 5.0.4


5.5 RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMNITY
TEST (RS)

5.5.1 TEST SPECIFICATION

Basic Standard: EN 61000-4-3


Frequency Range: 80 MHz ~ 1000 MHz, 800 MHz ~ 1000 MHz,
1400 MHz ~ 2100 MHz, 2100 MHz ~ 2500 MHz
Field Strength: 20 V/m, 20 V/m, 10 V/m, 5 V/m
Modulation: 1 kHz Sine Wave, 80%, AM Modulation
Frequency Step: 1 % of preceding frequency value
Polarity of Antenna: Horizontal and Vertical
Antenna Height: 1.55 m
Dwell Time: 3 seconds

5.5.2 TEST INSTRUMENTS

Description & Manufacturer Model No. Serial No. Cal. Date Cal. Due
BLMA
BONN Power Amp 118694 NA NA
1060-100/50D
BBA Power Amp B250C125 101011 NA NA
Power Sensor NRP-Z91 101572 Jan. 22, 2014 Jan. 21, 2015
Power Sensor NRP-Z91 101573 Jan. 22, 2014 Jan. 21, 2015
Signal Generator SMB100A 105801 Jan. 16, 2014 Jan. 15, 2015
EMC32 Version
R&S Software NA NA NA
8.52.0
Stacked Log-Per Antenna STLP9149 9149-141 NA NA
High GAIN LOG-Periodic
HL046E 100114 NA NA
Antenna

Notes: 1. The test was performed in Hwa Ya RS Room 2.


2. The calibration interval of the above test instruments is 12 months and the calibrations are
traceable to NML/ROC and NIST/USA.
3. The transmit antenna was located at a distance of 3 meters from the EUT.

Report No.: CE141111C02-1 36 of 56 Report Format Version 5.0.4


5.5.3 TEST PROCEDURE

The test procedure was in accordance with EN 61000-4-3.


a. The testing was performed in a modified semi-anechoic chamber.
b. The frequency range is swept 80 MHz ~ 1000 MHz, 800 MHz ~ 1000 MHz, 1400
MHz ~ 2100 MHz, 2100 MHz ~ 2500 MHz, with the signal 80% amplitude
modulated with a 1 kHz sinewave.
c. The dwell time at each frequency shall not be less than the time necessary for the
EUT to be exercised and to respond, but shall in no case be less than 0.5s.
d. The field strength level was 20V/m, 20V/m, 10V/m, 5V/m.
e. The test was performed with the EUT exposed to both vertically and horizontally
polarized fields on each of the four sides.

5.5.4 DEVIATION FROM TEST STANDARD

No deviation.

5.5.5 TEST SETUP

EUT

RF Amplifier
RF Generator
Monitoring
and
system
control system

For the actual test configuration, please refer to the related item – Photographs of
the Test Configuration.

NOTE:
TABLETOP EQUIPMENT
The EUT installed in a representative system as described in section 7 of EN 61000-4-3 was placed
on a non-conductive table 0.8 meters in height. The system under test was connected to the power
and signal wire according to relevant installation instructions.

Report No.: CE141111C02-1 37 of 56 Report Format Version 5.0.4


5.5.6 TEST RESULTS

Input Power 230 Vac, 50 Hz Test Date 2015/1/7


Environmental
25 °C, 55% RH Tested by Vincent Yang
Conditions

Frequency Applied Field Test Performance


Polarity Azimuth(°) Observation
(MHz) Strength (V/m) Distance (m) Criterion
80-1000 V&H 0, 90, 180, 270 20 1.75 Note 1 A
800-1000 V&H 0, 90, 180, 270 20 1.75 Note 1 A
1400-2100 V&H 0, 90, 180, 270 10 3 Note 1 A
2100-2500 V&H 0, 90, 180, 270 5 3 Note 1 A

*The EUT was tested with ground cable.

Note: 1. The EUT function was correct during the test.

Report No.: CE141111C02-1 38 of 56 Report Format Version 5.0.4


5.6 ELECTRICAL FAST TRANSIENT (EFT)

5.6.1 TEST SPECIFICATION

Basic Standard: EN 61000-4-4


Test Voltage: Power Line: 2 kV
Signal line: 2 kV
Polarity: Positive & Negative
Impulse Frequency: 5 kHz
Impulse Waveshape: 5/50 ns
Burst Duration: 15 ms
Burst Period: 300 ms
Test Duration: 1 min.

5.6.2 TEST INSTRUMENT

Description & Manufacturer Model No. Serial No. Cal. Date Cal. Due
EMC-Partner EFT
TRA2000EFT-C1 623 May 16, 2014 May 15, 2015
Generator
EMC-Partner
CN-EFT1000 364 May 16, 2014 May 15, 2015
Capacitive Coupling clamp
EFT Adapter WONPRO WA EF1Ada-001 NA NA
Software EMC-Partner GENECS NA NA NA

Notes: 1. The test was performed in Hwa Ya EFT Room 1.


2. The calibration interval of the above test instruments is 12 months and the calibrations are
traceable to NML/ROC and NIST/USA.

5.6.3 TEST PROCEDURE

a. Both positive and negative polarity discharges were applied.


b. The distance between any coupling devices and (0.5 − 0/+0.1) m for table-top
equipment testing, and (1.0 ± 0.1) m for floor standing equipment
c. The duration time of each test sequential was 1 minute.
d. The transient/burst waveform was in accordance with EN 61000-4-4, 5/50ns.

Report No.: CE141111C02-1 39 of 56 Report Format Version 5.0.4


5.6.4 DEVIATION FROM TEST STANDARD

No deviation.

5.6.5 TEST SETUP

NOTE:
(A) location for supply line coupling
(B) location for signal lines coupling

For the actual test configuration, please refer to the related item – Photographs of
the Test Configuration.

Report No.: CE141111C02-1 40 of 56 Report Format Version 5.0.4


5.6.6 TEST RESULTS

Input Power 230 Vac, 50 Hz Test Date 2014/12/21


Environmental Conditions 23 °C, 56% RH Tested by Andy Chang

Power port
Voltage (kV) Test Point Polarity (+/-) Observation Performance Criterion
2 L1 +/- Note 1
2 L2 +/- Note 1
2 L1-L2 +/- Note 1 A
2 PE +/- Note 1 (Judged by
2 L1-PE +/- Note 1 manufacturer)
2 L2-PE +/- Note 1
2 L1-L2-PE +/- Note 1

Signal port
Voltage (kV) Test Point Polarity (+/-) Observation Performance Criterion
2 LAN 1 +/- Note 1 A
(Judged by
2 LAN 2 +/- Note 1
manufacturer)

*The EUT was tested with ground cable.

Note: 1. The earphone had beep during the test, but could self-recover after the test.

Report No.: CE141111C02-1 41 of 56 Report Format Version 5.0.4


5.7 SURGE IMMUNITY

5.7.1 TEST SPECIFICATION

Basic Standard: EN 61000-4-5


Wave-Shape: Combination Wave
1.2/50 µs Open Circuit Voltage
8/20 µs Short Circuit Current
1.2/50 µs Wave for signal lines
8/20 µs Short Circuit Current
Test Voltage: Power Line: 0.5, 1, 2 kV
Signal Line: NA
Polarity: Positive/Negative
Phase Angle: 0 /90/180/270
Pulse Repetition Rate: 1 time / 60 sec.
Number of Tests: 5 positive and 5 negative at selected points

5.7.2 TEST INSTRUMENT

Description & Manufacturer Model No. Serial No. Cal. Date Cal. Due
Modular Impulse Generator
MIG0603IN3 352 Sep. 02, 2014 Sep. 01, 2015
EMC-Partner
Universal Surge Coupling
De-Coupling Network CDN UTP8 011 Sep. 02, 2014 Sep. 01, 2015
EMC-Partner
Surge Adapter WONPRO WA SU1 Ada-001 NA NA
Coupling and Decoupling
Network CDN2000 06 32 093 NA NA
EMC PARTNER

Notes: 1. The test was performed in Hwa Ya Surge Room 2.


2. The calibration interval of the above test instruments is 12 months and the calibrations are
traceable to NML/ROC and NIST/USA.

Report No.: CE141111C02-1 42 of 56 Report Format Version 5.0.4


5.7.3 TEST PROCEDURE

a. For EUT power supply:


The surge is to be applied to the EUT power supply terminals via the capacitive
coupling network. Decoupling networks are required in order to avoid possible
adverse effects on equipment not under test that may be powered by the same
lines, and to provide sufficient decoupling impedance to the surge wave. The
power cord between the EUT and the coupling/decoupling networks shall be 2
meters in length (or shorter).
For double-insulated products without PE or external earth connections, the test
shall be done in a similar way as for grounded products but without adding any
additional external grounded connections. If there are no other possible
connections to earth, line-to-ground tests may be omitted.
b. For test applied to unshielded unsymmetrically operated interconnection lines of
EUT:
The surge is applied to the lines via the capacitive coupling. The coupling /
decoupling networks shall not influence the specified functional conditions of the
EUT. The interconnection line between the EUT and the coupling/decoupling
networks shall be 2 meters in length (or shorter).
c. For test applied to unshielded symmetrically operated interconnection /
telecommunication lines of EUT:
The surge is applied to the lines via gas arrestors coupling. Test levels below the
ignition point of the coupling arrestor cannot be specified. The interconnection line
between the EUT and the coupling/decoupling networks shall be 2 meters in
length (or shorter).

5.7.4 DEVIATION FROM TEST STANDARD

No deviation.

Report No.: CE141111C02-1 43 of 56 Report Format Version 5.0.4


5.7.5 TEST SETUP

For the actual test configuration, please refer to the related item – Photographs of
the Test Configuration.

5.7.6 TEST RESULTS

Input Power 230 Vac, 50 Hz Test Date 2014/11/29


Environmental Conditions 23 °C, 53% RH Tested by Davis Chen

Power port
Voltage (kV) Test Point Polarity (+/-) Observation Performance Criterion
0.5, 1 L1-L2 +/- Note 1 A
0.5, 1, 2 L1-PE +/- Note 1 A
0.5, 1, 2 L2-PE +/- Note 1 A

Note: 1. The EUT function was correct during the test.

Report No.: CE141111C02-1 44 of 56 Report Format Version 5.0.4


5.8 CONDUCTED RADIO FREQUENCY DISTURBANCES (CS)

5.8.1 TEST SPECIFICATION

Basic Standard: EN 61000-4-6


Frequency Range: 0.15 MHz ~ 80 MHz
Voltage Level: 10 Vrms
Modulation: 1kHz Sine Wave, 80%, AM Modulation
Frequency Step: 1 % of preceding frequency value
Dwell Time: 3 seconds

Report No.: CE141111C02-1 45 of 56 Report Format Version 5.0.4


5.8.2 TEST INSTRUMENT

Description & Manufacturer Model No. Serial No. Cal. Date Cal. Due
FCC POWER LINE COUPLING
FCC-801-M1-25A 03030 May 22, 2014 May 21, 2015
DECOUPLING NETWORK
FCC POWER LINE COUPLING
FCC-801-M2-25A 03049 Nov. 07, 2014 Nov. 06, 2015
DECOUPLING NETWORK
FCC POWER LINE COUPLING
FCC-801-M2-25A 03050 Nov. 07, 2014 Nov. 06, 2015
DECOUPLING NETWORK
FCC POWER LINE COUPLING
FCC-801-M3-25A 03056 Nov. 07, 2014 Nov. 06, 2015
DECOUPLING NETWORK
FCC POWER LINE COUPLING
FCC-801-M3-25A 03057 Nov. 07, 2014 Nov. 06, 2015
DECOUPLING NETWORK
FCC SIGNAL LINE POWER
LINE
FCC-801-T2 03030 Nov. 07, 2014 Nov. 06, 2015
COUPLING DECOUPLING
NETWORK
FCC SIGNAL LINE POWER
LINE
FCC-801-T4 03031 Nov. 07, 2014 Nov. 06, 2015
COUPLING DECOUPLING
NETWORK
FCC SIGNAL LINE POWER
LINE
FCC-801-T8 03032 Nov. 07, 2014 Nov. 06, 2015
COUPLING DECOUPLING
NETWORK
EMI Injection Clamp F203I-23MM 434 Nov. 07, 2014 Nov. 06, 2015
Amplifier Research
75A250AM2 307804 NA NA
Power Amplifier
BOONTON 4232ARF
4232A-01-02 104302 Nov. 14, 2014 Nov. 13, 2015
POWER METER
R&S Signal Generator SML01 102148 Nov. 14, 2014 Nov. 13, 2015
Software ADT_CS_V37 NA NA NA
POWER SENSOR 51011-EMC 30028 Nov. 14, 2014 Nov. 13, 2015
POWER SENSOR 51011-EMC 33029 Nov. 14, 2014 Nov. 13, 2015

Notes: 1. The test was performed in Hwa Ya CS Room 1.


2. The calibration interval of the above test instruments is 12 months and the calibrations are
traceable to NML/ROC and NIST/USA.

Report No.: CE141111C02-1 46 of 56 Report Format Version 5.0.4


5.8.3 TEST PROCEDURE

a. The EUT shall be tested within its intended operating and climatic conditions.
b. An artificial hand was placed on the hand-held accessory and connected to the
ground reference plane.
c. One of the CDNs not used for injection was terminated with 50Ω, providing only
one return path. All other CDNs were coupled as decoupling networks.
d. The frequency range is swept from 150 kHz to 80 MHz, using the signal level
established during the setting process and with a disturbance signal of 80 %
amplitude. The signal is modulated with a 1 kHz sine wave, pausing to adjust the
RF signal level or the switch coupling devices as necessary. Where the frequency
is swept incrementally, the step size shall not exceed 1% of the preceding
frequency value.
e. The dwell time of the amplitude modulated carrier at each frequency shall not be
less than the time necessary for the EUT to be exercised and to respond, but
shall in no case be less than 0.5 s. The sensitive frequencies (e.g. clock
frequencies) shall be analyzed separately.
f. Attempts should be made to fully exercise the EUT during testing, and to fully
interrogate all exercise modes selected for susceptibility.

5.8.4 DEVIATION FROM TEST STANDARD

No deviation.

Report No.: CE141111C02-1 47 of 56 Report Format Version 5.0.4


5.8.5 TEST SETUP

Note: 1.The EUT clearance from any metallic obstacles shall be at least 0.5 m.
2. Interconnecting cables (≦1 m) belonging to the EUT shall remain on the insulating
support.

For the actual test configuration, please refer to the related item – Photographs of
the Test Configuration.

NOTE:
The equipment to be tested is placed on an insulating support of 0.1 meters height above a ground
reference plane. All relevant cables shall be provided with the appropriate coupling and decoupling
devices at a distance between 0.1 meters and 0.3 meters from the projected geometry of the EUT on
the ground reference plane.

Report No.: CE141111C02-1 48 of 56 Report Format Version 5.0.4


5.8.6 TEST RESULTS

Input Power 230 Vac, 50 Hz Test Date 2014/12/1


Environmental Conditions 23 °C, 58% RH Tested by Davis Chen

Frequency Level Injection Return Performance


Tested Line Observation
(MHz) (Vrms) Method Path Criterion
0.15 – 80 10 Power CDN-M3 EM-Clamp Note 1 A
0.15 – 80 10 LAN 1 EM-Clamp CDN-M3 Note 1 A
0.15 – 80 10 LAN 2 EM-Clamp CDN-M3 Note 1 A

Note: 1. The EUT function was correct during the test.

Report No.: CE141111C02-1 49 of 56 Report Format Version 5.0.4


6 PHOTOGRAPHS OF THE TEST CONFIGURATION
Conducted Emissions Test

Report No.: CE141111C02-1 50 of 56 Report Format Version 5.0.4


Radiated Emissions Test

Report No.: CE141111C02-1 51 of 56 Report Format Version 5.0.4


ESD Test

RS Test

Report No.: CE141111C02-1 52 of 56 Report Format Version 5.0.4


EFT Test - Mains ports

EFT Test - Signal ports

Report No.: CE141111C02-1 53 of 56 Report Format Version 5.0.4


Surge Test - Mains ports

CS Test - Mains ports

Report No.: CE141111C02-1 54 of 56 Report Format Version 5.0.4


CS Test - Signal ports

Report No.: CE141111C02-1 55 of 56 Report Format Version 5.0.4


7 INFORMATION ON THE TESTING LABORATORIES
We, Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, were
founded in 1988 to provide our best service in EMC, Radio, Telecom and Safety
consultation. Our laboratories are accredited and approved according to ISO/IEC
17025.

If you have any comments, please feel free to contact us at the following:

Linko EMC/RF Lab Hsin Chu EMC/RF/Telecom Lab


Tel: 886-2-26052180 Tel: 886-3-5935343
Fax: 886-2-26051924 Fax: 886-3-5935342

Hwa Ya EMC/RF/Safety Lab


Tel: 886-3-3183232
Fax: 886-3-3270892

Email: [email protected]
Web Site: www.bureauveritas-adt.com

The address and road map of all our labs can be found in our web site also.

--- END ---

Report No.: CE141111C02-1 56 of 56 Report Format Version 5.0.4