0% found this document useful (0 votes)
46 views

Pump Sizing Calculation

The document provides details on sizing a feed pump for a given flowrate, density, viscosity, and vapor pressure. It includes calculations for differential pressure, head, power requirements, and available net positive suction head. Pipe dimensions, fittings, velocities, and pump curve data are also listed to determine the required pump specifications.

Uploaded by

Hatif Alam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
46 views

Pump Sizing Calculation

The document provides details on sizing a feed pump for a given flowrate, density, viscosity, and vapor pressure. It includes calculations for differential pressure, head, power requirements, and available net positive suction head. Pipe dimensions, fittings, velocities, and pump curve data are also listed to determine the required pump specifications.

Uploaded by

Hatif Alam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 4

PUMP SIZING CALCULATION

CheGuide.com Tag No. P-101


Chemical Engineer's Guide Description Feed Pump
Date 06-May-2017
User Input By CheGuide

Pipe Diameter - ID2


Flowrate 100.0 US gpm Pipe Length - L2 P2
Density 62.40 lb/ft3
P1
Viscosity 1.00 cP h2
Vapor Pressure 15.0 psia h1

Differential DP 49.01 psi


Pipe Diameter - ID1
Differential Head 113.2 ft Pipe Length - L1
Hydraulic power 2.86 bhp
NPSH available 12.9 ft

Suction Condition Discharge Condition


Pressure P1 25.0 psia Pressure P2 50.0 psia
Static Head h1 5.0 ft Static Head h2 25.0 ft
Equipment DP 5.0 psi Equipment DP 5.0 psi
Misc DP 0.0 psi Misc DP 0.0 psi

Piping Piping
Length L1 120.0 ft Length L2 300.0 ft
Pipe Diameter 3 inch Pipe Diameter 3 inch
Sch/ Thick 40 Sch/ Thick 40
Pipe ID ID1 3.068 inch Pipe ID ID2 3.068 inch

Roughness 0.0018 inch Roughness 0.0018 inch

Fittings No. K DP Fittings No. K DP


Elbows, 90LR 1 0.27 0.03 Elbows, 90LR 1 0.27 0.03
Elbows, 45LR 1 0.20 0.03 Elbows, 45LR 1 0.20 0.03
Tees, Thru 1 0.66 0.08 Tees, Thru 1 0.66 0.08
Tees, Branch 1 1.07 0.14 Tees, Branch 1 1.07 0.14
Ball Valves 0.20 Ball Valves 0.20
Butterfly Valves 0.34 Butterfly Valves 0.34
Gate Valves 1 0.14 0.02 Gate Valves 1 0.14 0.02
Globe Valves 5.32 Globe Valves 5.32
Check Valves 2.00 Check Valves 1 2.00 0.25
Plug Valves 0.34 Plug Valves 0.34
Pipe Entrance 1 0.50 0.06 Pipe Exit 1 1.00 0.13
0.36 0.68
Velocity 4.34 ft/s Velocity 4.34 ft/s
Reynold's No. 103036 Reynold's No. 103036
Pipe DP 1.03 psi/100ft Pipe DP 1.03 psi/100ft
Suction Pressure 20.57 psia Discharge Pressure 69.58 psia
PUMP SIZING CALCULATION
CheGuide.com Tag No. P-101
Chemical Engineer's Guide Description Feed Pump
Date 06-May-2017
User Input By CheGuide

Pump Manufacturer's Curve Maximum Flow 180 US gpm


Flow value till which System and Head Curve
Flow Head Efficiency are calculated
gpm ft %
0.0 150.0 20.0 Operating Conditions
20.0 147.0 28.0 Flowrate 108.8 US gpm
50.0 140.0 37.0 Head 115.3 ft
80.0 129.0 43.0 Efficiency 45.54 %
100.0 120.0 45.0 Hydraulic Power 3.17 bhp
150.0 90.0 44.0 Rated Power 6.96 bhp
180.0 67.0 40.0
200.0 50.0 35.0

Pump Head System Curve Efficiency %

160 50

45
140
40
120
35
100
30
Efficiency (%)
Head (ft)

80 25

20
60
15
40
10
20
5

0 0
0.0 20.0 40.0 60.0 80.0 100.0 120.0 140.0 160.0 180.0 200.0
Flow (US gpm)
PUMP SIZING CALCULATION
CheGuide.com Tag No. P-101
Chemical Engineer's Guide Description Feed Pump
Date 06-May-2017
User Input By CheGuide

Pipe Diameter - ID2


Flowrate 7.9 m³/h Pipe Length - L2 P2
Density 803 kg/m³
P1
Viscosity 0.12 cP h2
Vapor Pressure 0.0 bar abs h1

Differential DP 4.41 bar


Pipe Diameter - ID1
Differential Head 55.9 m Pipe Length - L1
Hydraulic power 0.97 kw
NPSH available 12.23 m

Suction Condition Discharge Condition


Pressure P1 1.2 bar abs Pressure P2 5.0 bar abs
Static Head h1 1.5 m Static Head h2 3.0 m
Equipment DP 0.34 bar Equipment DP 0.00 bar
Misc DP 0.00 bar Misc DP 0.00 bar

Piping Piping
Length L1 36.6 m Length L2 609.6 m
Pipe Diameter 3 inch Pipe Diameter 3 inch
Sch/ Thick 40 Sch/ Thick 40
Pipe ID ID1 77.93 mm Pipe ID ID2 77.93 mm

Roughness 0.04572 mm Roughness 0.04572 mm

Fittings No. K DP Fittings No. K DP


Elbows, 90LR 1 0.27 0.000 Elbows, 90LR 1 0.27 0.000
Elbows, 45LR 1 0.20 0.000 Elbows, 45LR 1 0.20 0.000
Tees, Thru 1 0.66 0.001 Tees, Thru 1 0.66 0.001
Tees, Branch 1 1.06 0.001 Tees, Branch 1 1.06 0.001
Ball Valves 0.20 Ball Valves 0.20
Butterfly Valves 0.33 Butterfly Valves 0.33
Gate Valves 1 0.13 0.000 Gate Valves 1 0.13 0.000
Globe Valves 5.31 Globe Valves 5.31
Check Valves 1 1.99 0.002 Check Valves 1.99
Plug Valves 0.34 Plug Valves 0.34
Pipe Entrance 1 0.50 0.000 Pipe Exit 1 1.00 0.001
0.004 0.003
Velocity 0.46 m/s Velocity 0.46 m/s
Reynold's No. 246702 Reynold's No. 246702
Pipe DP 0.021 bar/100m Pipe DP 0.021 bar/100m
Suction Pressure 0.96 bar Discharge Pressure 5.37 bar
PUMP SIZING CALCULATION
CheGuide.com Tag No. P-101
Chemical Engineer's Guide Description Feed Pump
Date 06-May-2017
User Input By CheGuide

Pump Manufacturer's Curve Maximum Flow 41 m³/h


Flow value till which System and Head Curve
Flow Head Efficiency are calculated
m³/h m %
0.0 45.7 20.0 Operating Conditions
4.5 44.8 28.0 Flowrate 0.0 m³/h
11.4 42.7 37.0 Head 54.1 m
18.2 39.3 43.0 Efficiency 20.14 %
22.7 36.6 45.0 Hydraulic Power 0.00 kW
34.1 27.4 44.0 Rated Power 0.00 kW
40.9 20.4 40.0
45.4 15.2 35.0

Pump Head System Curve Efficiency %

120 50

45
100
40

35
80
30
Efficiency (%)
Head (m)

60 25

20
40
15

10
20
5

0 0
0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0
Flow (m3/h)