0% found this document useful (0 votes)
36 views

Typical Ductile Moment Frame Beam Detail: S4 A Proposed One-Storey Residential Building

The document shows a diagram of a concrete beam with columns and reinforcement bars. It displays the different sections of the beam and placement of reinforcement bars including top bars, web bars, and vertical column bars. Notations are provided for lap splice lengths and concrete cover.

Uploaded by

Jezreel Flotilde
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
36 views

Typical Ductile Moment Frame Beam Detail: S4 A Proposed One-Storey Residential Building

The document shows a diagram of a concrete beam with columns and reinforcement bars. It displays the different sections of the beam and placement of reinforcement bars including top bars, web bars, and vertical column bars. Notations are provided for lap splice lengths and concrete cover.

Uploaded by

Jezreel Flotilde
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

COLUMN COLUMN COLUMN

LC L1 L2
°
135
3/4 LC OR L1 / 4 L1 / 4 OR 3/4 LC L1 / 4 OR L2 / 4 L2 / 4 OR L1 / 4 SPLICE ZONE FOR L2 / 4

6d
b
(GREATER GOVERNS) (GREATER GOVERNS) (GREATER GOVERNS) GIRDER TOP BARS
SPLICE LENGTH
SEE TABLE CONCRETE BEAM
SPLICE LENGTH db
TOP BARS

40mm COVER
EQ. EQ. TOP BARS SEE TABLE

(TYPICAL)
COLUMN VERTICAL BARS AT SUPPORT CONTINUOUS
(SEE COLUMN SCHEDULE) TOP BARS AT EQ. EQ. WEB BARS
TOP BARS ADDITIONAL ROW OF TOP NOTES:
COLUMN TIES/HOOPS CANTILEVER'S TOP BARS TOP BARS
AT MIDSPAN BARS (AS REQUIRED)
(SEE SCHEDULE) DISCONTINUOUS AT SUPPORT AT MIDSPAN
END 1. SEE TABLE OF LAP SPLICE & ANCHORAGE
FINISH FLOOR LINE

EQUAL EQUAL EQUAL


LENGTHS SHOWN ON SHEET

(SEE SCHEDULE)
40MM CLEAR TO

BEAM HEIGHT
2. LAP SPLICE SHALL BE LOCATED ONLY
EMBEDMENT DEPTH

STIRRUPS (TYPICAL)
WITHIN THE LAP SPLICE ZONE

VARIES

40mm COVER
FILL FILL

(TYPICAL)
BOTTOM BARS 2d EQ. EQ. BOTTOM BARS EQ. EQ.
AT SUPPORT AT MIDSPAN BEAM HOOPS / STIRRUPS
2d 2d
L1 / 6 4. CLOSED HOOPS / STIRRUPS WITH 135° BEND
0.075

BOTTOM BARS SHALL BE SPACED @ 100MM O.C. MAXIMUM AT


AT CANTILEVER'S A DISTANCE 2D FROM THE FACE OF THE SUPPORT.
50mm MAX. ADDITIONAL ROW OF BOTTOM
t DISCONTINUOUS FIRST STIRRUP SHALL BE 50MM FROM THE FACE
AT SUPPORT BARS (AS REQUIRED)
END L1 / 6 OF THE SUPPORT
50MM THK LEAN CONCRETE WEB BARS
BOTTOM BARS
(TYPICAL)
SECTION HOOP REINFORCEMENT HOOP REINFORCEMENT HOOP REINFORCEMENT
SEE SCHEDULE SEE SCHEDULE SEE SCHEDULE
X-DIRECTION Y-DIRECTION DISCONTINUOUS END NOTES:
DISCONTINUOUS CONTINUOUS END CONTINUOUS END SLAB REINFORCEMENT NOT SHOWN FOR CLARITY
BARS BARS FREE END
SECTION
NOTES:
1. AT INTERIOR SUPPORT (CONTINUOUS END) PROVIDE LARGER SIZE AND
ELEVATION
b NUMBER OF TOP AND BOTTOM BARS FROM ADJACENT SPAN.
2. NO SPLICE SHALL BE ALLOWED 2d FROM THE FACE OF THE SUPPORT TYPICAL DUCTILE MOMENT FRAME BEAM DETAIL
B

FOR SIZE, AND SPACING OF NOTES:


STIRRUPS, SEE REINFORCED 1. L1, L2 = LENGTH OF CLEAR SPANS 1, 2 (FACE OF SUPPORT TO FACE OF SUPPORT)
CONCRETE BEAM SCHEDULE 2. L = THE GREATER LENGTH OF L1 OR L2
L INTERIOR SUPPORT INTERIOR SUPPORT INTERIOR SUPPORT 3. AT INTERIOR SUPPORT (CONTINUOUS END) PROVIDE LARGER SIZE AND NUMBER OF

STIRRUP (TYPICAL)
TOP BARS FROM ADJACENT SPANS.

40mm CLEAR TO
BOTTOM BARS LAYOUT PLAN 4. EXTERIOR AND INTERIOR SUPPORT REINFORCEMENT NOT SHOWN FOR CLARITY
L1 / 4 TOP BAR L/4 L/4 TOP BAR L/4 L/4
SPLICE ZONE (TYP.) SPLICE ZONE (TYP.) CONCRETE BEAM
TYPICAL FOOTING DETAILS TOP BARS

STANDARD 90
TOP BARS TOP BARS EXTRA TOP BARS CONT. TOP BARS ADDITIONAL ROW OF TOP
DEGREE HOOK
(TYPICAL) BARS (AS REQUIRED)

EQUAL EQUAL EQUAL


L1 / 6 L1 / 6 L2 / 6 L2 / 6

STIRRUP (TYPICAL)
EXTRA EXTRA

DEPTH
40mm CLEAR TO
BOTTOM BOTTOM
Y-DIRECTION Y-DIRECTION BARS BOTTOM BAR BARS BOTTOM BAR
BARS BARS SPLICE ZONE (TYP.) SPLICE ZONE (TYP.) BEAM STIRRUPS
CONTINUOUS CONTINUOUS
SIDE BARS (TYP.) SEE
BOTTOM BARS BOTTOM BARS
SCHEDULE FOR SIDE
FOOTING TIE BEAM 40MM CLEAR MIN.
AND NUMBER ADDITIONAL ROW OF BOTTOM
(SEE SCHEDULE) 75MM CLEAR MAX.
CONCRETE CONCRETE BARS (AS REQUIRED)
COLUMN COLUMN WEB BARS
WIDTH
B1

B2

OR BEAM OR BEAM (TYPICAL)


BOTTOM BARS (SEE SCHEDULE)
(TYPICAL) (TYPICAL)
L1 L2 L1 OR L2
X-DIRECTION (CLEAR SPAN) (CLEAR SPAN) (CLEAR SPAN) NOTE: SLAB REINFORCEMENT NOT SHOWN FOR CLARITY
BARS X-DIRECTION
BARS EXTERIOR SUPPORT INTERIOR SUPPORT INTERIOR SUPPORT
(DISCONTINUOUS END) (CONTINUOUS END) (CONTINUOUS END)
SECTION
L1 L2 ELEVATION
PLAN
FOOTING 1 FOOTING 2
TYPICAL GRAVITY REINFORCED CONCRETE BEAM DETAIL
VERTICAL COLUMN BARS
(SEE SCHEDULE) COLUMN TIES/HOOPS
(SEE SCHEDULE)
MAIN TOP BARS b
TIE BEAM 30 BAR Ø (min) 30 BAR Ø (min)
(SEE SCHEDULE) TOP BARS
FINISH FLOOR LINE
MAIN REINFORCEMENTS

DEPRESSION
VARIES

D=FOR BEAM
t=FOR SLAB
EMBEDMENT DEPTH

VERIFY
h

A 25
BOTTOM BARS
SECTION A - A
t/2

t
t/2

FOOTING SLOPE 1:2 V:H


t1 (mm)

t2 (mm)

30 BAR Ø (min)
BARS
MAIN BOTTOM BARS A Ø10 x 1.0m LONG @ 300 O.C.
(PLACED AT MID-DEPTH OF SLAB
50MM THK LEAN CONCRETE 50MM THK LEAN CONCRETE IF THE LOCATION OF THE CONST. D=FOR BEAM
75

75

JOINT IS NOT WITHIN THE MIDDLE 2t=FOR SLAB


L1 L2 THIRD.

SECTION
TYPICAL TIE BEAM TO FOOTING DETAILS SUSPENDED SLAB CONSTRUCTION BEAM/SLAB CHANGE SOFFIT
DETAIL

CIVIL ENGINEER PROJECT TITLE: APPROVED BY: SHEET NO.:

ARIEL JOSEPH L. PLOMEDA


A PROPOSED ONE-STOREY RESIDENTIAL BUILDING &
PRC #: DATE: JOY L. PLOMEDA S4
TIN:
LOCATION: DAMO-ONG, JANIUAY, ILOILO CITY OWNER
PTR #: PLACE:

You might also like