You are on page 1/ 2

DWG PART

QTY DESCRIPTION MATERIAL


REF NUMBER
SHELL
Filament Wound Epoxy/Glass
1 1 200068 SHELL composites - Head locking grooves
integrally wound in place.
2 A/R 96327 3" Feed Port SA-995 CD3MWCuN (UNS J93380)
3 A/R 96119 3" Port Seal Sq. Seal - EPDM
4 1 97988 1" FNPT Drain Port Engineering Thermoplastic-Noryl
5 1 97989 1" Drain Port Seal Sq. Seal - EPDM
HEAD COMPONENTS ITEM QUANTITY PART NO. DESCRIPTION
1 6'' Long RRS-01027 Tubing Blue
6 1 17174 1/4" FNPT Air Vent Port Engineering Thermoplastic-PVC Male Connector,Pipe 1/4''
1 RRS-010013
7 2 45286 1/4" Air Vent Port Seal O - Ring - EPDM 2 Tube 1/4''
3 2 RRS-01047 Compression nut 1/4''
8 1 98731 Elliptical Head Engineering Thermoplastic-Noryl
4 1 RRS-01039 Ball Valve 1/4''
9 1 17176 Bearing Plate Product end SB-221 A96061-T6 5 1 17194 Blind Plug 1/4"
10 1 117006 Sealing Plate Product end Engineering Thermoplastic-Noryl "L" "S" Approx Weight ** Approx Weight With
Element
IN(MM) IN(MM) LB(KG) Filter LB(KG)
11 1 17187 3" Product Port Engineering Thermoplastic-PVC
76.37 42X1
12 1 17127 3" Port Retainer Ring SA-479 316 60 60(27) 63(29)
(1940) (1067)
13 2 96000 Head Seal O - Ring - EPDM
14 1 17128 Product Port Seal O - Ring - EPDM
15 1 17286 Blind Plug Kit Engineering Thermoplastic
HEAD INTERLOCK
16 2 47336 Quick Release Spiral Ring SA-479 316

VESSEL SUPPORT
17 2 52169 Saddle Engineering Thermoplastic
18 2 45042 Strap Assy. 304 Stainless Steel-PVC Cushion.
5/16-18 UNC X 2.5" Long, 18-8
19 4 46265 Strap screw.
Stainless Steel.
RATING: PRECAUTIONS: ORDERING:
Using the chart below, please check the features you require.
DESIGN PRESSURE…………………..……....150 PSIG DO…read, understand and follow all instructions;
(1.0 MPa) failure to take every precaution will void warranty VESSEL LENGTH CODE
MAX. OPERATING TEMP………..….......…….....113°F and may result in vessel failure
(45°C) MODEL: AquaLine 80AQ15 Non Coded -60
DO…mount the shell on horizontal/vertical members at
MIN. OPERATING TEMP………..….....….…….....20°F
span “S” using compliant vessel supports
(-7°C)
furnished; for mounting vessels vertically provide CERTIFICATION REQUIRED
FACTORY TEST PRESSURE….… ……..….. 225 PSIG
proper bottom support; tighten hold down straps
(1.55 MPa)
just snug.  CE Marked Standard.
QUALIFICATION PRESSURE…………… … 900 PSI
(6.2 MPa) DO…align and center side ports with the manifold
INTENDED USE: header. Correct, causes of misalignment in a row of
FEED PORT CONFIGURATION
vessels connected to the same header
Please fill out quantity for each configuration
The AquaLine 80AQ15 Non Coded Fiberglass Pressure DO…use flexible type IPS grooved-end pipe couplings,
Vessel is designed for continuous, long term use as or equal, at side ports; allow full, 0.125 inch gap  1 A 4 G (Standard)
housing for AquaLine range of micro filtration elements. between port and piping, and position piping to
maximize flexibility of connection.  1 A 2G (Optional)
The Shell of AquaLine 80AQ15 Non Coded vessel is
designed in accordance with the engineering standards of DO…provide flexibility in, and support for piping  1A2G4G (Optional)
the Boiler and Pressure Vessel Code of the American manifolds so that vessel can grow in length under
Society of Mechanical Engineers (ASME) as per Section pressure without undue restraint; provide additional
X Edition 2019 and all metallic parts are designed as per flexible joints in large pipes leading to manifold
Section VIII Division I Edition 2019. header. DRAIN PORT
The AquaLine 80AQ15 Non Coded vessel must be DO… Lubricate seals sparingly, using nonpetroleum  1” FNPT CONNECTION - Noryl (Standard)
installed, operated and maintained in accordance with the Based lubricants, i.e. Parker Super O-lube®,
listed precautions and good industrial practice to assure Glycerin or suitable silicone based lubricants.  1” FNPT CONNECTION – CD3MWCuN (P/N 17180) (Optional)
safe operation over a long service life. Note: P/N 45340 – 1” Drain Port Seal has to be used with port P/N 17180
DO…provide overpressure protection for vessel set at
The high performance Filament wound FRP shell must be not more than 105% of design pressure FEED PORT (OPTIONAL)
allowed to expand under pressure; undue restraint at
support points or piping connections can cause leaks to DO…inspect end closures regularly; replace  3” IPS GROOVED CONNECTION – CD3MWCuN (P/N 98804)
develop in the shell. This side-ported vessel requires components that have deteriorated and correct Note: For vessel center to feed port height (6.38 ± .03) as per 80CF15 Non-Coded
special precautions in mounting and connection to piping causes of corrosion
so that the vessel will not be subjected to excessive stress
due to bending moments acting at the side openings in the DO NOT…work on any component until first verifying SAMPLE VALVE KIT – 17467 (OPTIONAL)
fiberglass shell. The end closure, incorporating close that pressure is relieved from vessel
fitting, interlocking metal components, must be kept dry  Yes
and free of corrosion; deterioration can lead to DO NOT…make rigid piping connections to ports or
catastrophic mechanical failure of the head. clamp vessel in any way that resists growth of
ITEM QUANTITY PART NO. DESCRIPTION
fiberglass shell under pressure;
Pentair will assist the purchaser in determining the 1 1 96524 BALL VALVE 1/2"
suitability of this standard vessel for their specific DO NOT…pressurize vessel until double-checking to 2 1 96526 ADP 1/2" MNPT X 1" MNPT
operating conditions. The final determination however, verify that the Spiral Ring is in place and fully 3 1 17468 SAMPLE PLUG KIT
including evaluation of the standard material of seated.
construction for compatibility with the specific corrosive
environment, shall be the responsibility of the purchaser. DO NOT…operate vessel at pressure and temperature
Alternate materials with enhanced corrosion resistance are in excess of its rating.
available on special order.
DO NOT…tolerate leaks or allow end closures to be
Specifications are subject to change without notice. routinely wetted in any way

DO NOT…operate outside the pH range of 3-11.

For complete information on proper use of the vessel

Please refer to the 80AQ15 User Guide No 98760.

DWG. NO. 200268 Rev- D © Pentair. PAGE 2 OF 2.